Loading...
10-723-041PLUMBING SPECIFICATIONS: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 2007 AND ALL CODES ADOPTED BY IT. 2. PRIOR TO ORDERING , CON TRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AN D EQUIPMENT TO ENGINEER OF RECORD FOR APPROVAL. 3. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK IS FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP, AND FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE REPAIR AND REP L LACE AL WORK WHICH BECOMES DEFECTIVE AT NO EXPENSE TO THE OWNER 4. MATERIALS SHALL BE AS FOLLOWS: A. DOMESTIC WATER PIPING — TYPE 'L' COPPER WITH LEAD FREE SOLDER B. SANITARY WASTE PIPING — SERVICE WEIGHT NO —HUB CAST IRON. C. CONDENSATE DRAINAGE PIPING — TYPE 'L' COPPER IN 1" ARMAFLEX D. VALVES — BRONZE NOBCO OR EQUAL AND RATED AT 125 PSI 5. ALL PLUMBING FIXTURES SHALL BE WATER SAVER PER CODE. FPC TABLE 604.4. TYPE, COLOR AND TRIM TO BE SELECTED BY OWNER. 6. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS. 7. COMPLETE SYSTEM: FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN— SERVICE TEST AFTER COMPLETION OF INSTALLATION. 8. FURNISH REQUIRED FLASHING TO ROOFING CONTRACTOR FOR PIPES PENETRATING THE ROOF 9. ASSE 1010 CERTIFIED WATER HAMMER ARRESTORS SHALL BE ONLY APPROVED MEANS OF CONTROLLING WATER HAMMER. FIXTURE SCHEDULE MARK DESCRIPTION COLD HOT DRAIN WC1 SLOAN MODEL WETS 2020.1001 -1.28 (1.28 GPF) 1" cT- 3" Cam-- COMPLETE HET (HIGH EFFICIENCY TOILET) SYSTEM WITH o- PIPE TURNS UP -ilF- UNION EXPOSED MANUAL ROYAL CLOSET FLUSHOMETER AND VITREOUS HOSE BIBB A' WATER HAMMER ARRESTOR CHINA ADA COMPLAIANT WATER CLOSET. WALL CLEAN OUT �M WATER METER FLOOR MOUNTED WITH RIM AT 17" AFF. FLOOR CLEAN OUT ----- - - - - -- COLD WATER PIPING - --- OPEN FRONT SEAT WITHOUT COVER. SANITARY WASTE PIPING -- - - WC2 SLOAN MODEL WETS 2000.1001 -1.28 (1.28 GPF) 1" —•— 3" - - -- COMPLETE HET (HIGH EFFICIENCY TOILET) SYSTEM WITH EXPOSED MANUAL ROYAL CLOSET FLUSHOMETER AND VITREOUS CHINA WATER CLOSET. FLOOR MOUNTED WITH RIM AT 15" AFF. OPEN FRONT SEAT WITHOUT COVER. UR1 SLOAN MODEL WEUS 1000.1001 -0.13 (0.13 GPF) 3/4 n 2" COMPLETE HEU (HIGH EFFICIENCY URINAL) SYSTEM WITH EXPOSED MANUAL ROYAL URINAL FLUSHOMETER AND VITREOUS CHINA URINAL. WALL MOUNTED WITH RIM AT 17" AFF (FOR ADA). UR2 SLOAN MODEL WEUS 1000.1001 -0.13 (0.13 GPF) 3/4" 2" COMPLETE HEU (HIGH EFFICIENCY URINAL) SYSTEM WITH EXPOSED MANUAL ROYAL URINAL FLUSHOMETER AND VITREOUS CHINA URINAL. WALL MOUNTED WITH RIM AT 24" AFF. LAV EXISTING WALL MOUNTED LAVATORIES TO BE REUSED WITH NEW 1/2" 1/2" 1 1/4" 0.5 GPM FAUCETS. SYMMONS MODEL S- 20- 0 -LP -.5 SINGLE LEVER FAUCET WITH NO LIFT ROD HOLE, LOOP HANDLE WITH METAL FINISH, 0.5 GPM FLOW RESTRICTOR SPRAY AERATOR. PROVIDE TRUE BRO PROTECTIVE SHIELD FOR EXPOSED DRAINAGE, HOT AND COLD WATER PIPING. SYMBOL LEGEND SYMBOL DESCRIPTION D4 GATE VALVE { BALL VALVE P &T RELIEF VALVE cT- GATE VALVE IN RISER Cam-- -- PPE I TURNS DOWN o- PIPE TURNS UP -ilF- UNION + HOSE BIBB A' WATER HAMMER ARRESTOR LETTER DENOTES SIZE. WALL CLEAN OUT �M WATER METER ® FLOOR CLEAN OUT ----- - - - - -- COLD WATER PIPING - --- - - - - -- - -- HOT WATER PIPING SANITARY WASTE PIPING -- - - - - - - - - VENT PIPING CONDENSATE DRAIN PIPE —•— PAN — PAN DRAIN PIPE - - -- P &T -- P &T RELIEF PIPE KEYED NOTES OREPLACE EXISTING FLOOR MOUNTED FLUSH VALVE WATER CLOSET WITH NEW IN SAME LOCATION. RECONNECT TO EXISTING TOILET _ ;W LINE. 3 FAUCET ON OUNTED LAVATORY :ONNECT TO COLD SHUT OFF TANKLESS WATER SIN. 9KW 277/1/60. EXISTING 1ST FL RESTROOMS R '2 1 1AJR ......... ........... . ... ....... ll _�c>� - T_ - 1G11TT7r1.2- r�1I'�L�� r . ;, �T�ZZ�= T. = ,/7,J�.'TI:�7,L�.'TIr.�L"T ✓r , ................. . r- s 4�o �......,, ................,, 1. z :.J s is ......... ................. . r , , f ,t _ ........... ...... ... .. _......... I f _.. .. ... ... ...... ... ;/ i s i i i i - -- --- - - - - -- I I : t ' , r t � r �rrrll i , �tl ............... t 1 i ' i% % } x' / + ,„ J �r o, _ STO RAG.', E 1 ,� i / / ka �__'----- ---_� -: `- J �! 1ST FLOOR PLUMBING PLAN WARNING! MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. SCALE: 1/8" = f -0" THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED REWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE PLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF :NZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE PRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISS HENZ ENGINEERING INC. I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHpRIZATION #3880 TO PROVIDE THE ENGINEERING SERVICE. fa S1 4 -11-1H7 EflGl UR.N, 1HC_ � ��� �,' CO[1SlJLTIf1G Ef1GIfl��ftS D VID A 6 -'H WT, P E 2320 NE 9th Street, Suite 200 „J ?�:' t., Fort Lauderdale, Florida 33304 TEE 0 59492 T 954,523.4933 DOFF OKD RI F954,523.5052 u www, henz,00m 4 9i�E " < "_.,;x� «� "�i "" PROJECT No.: 10012.00 architect NORBERTO ROSENSTEIN ARCHITECT INC. 126 S. FEDERAL HIGHWAY SUITE #r 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIbinfoarosensteinarchRectcom WEBS www.roeensteinarchdect.com STATE REGF_ NO. ARZ0016&74 NATL. RECz. NO. &&3178 COPYRIGHT © 2010 NORMRTO R08ENSTON AR--HITECT, INC. ALL RIGWTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY POW U,aTHO1.1T PEf " IISSION. DESIGNED l „ l DRAWN p5 / % / i i � /,, ,// FWA CHECKED I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. 00 elt ®n + len iz A R Q U I T E C T 0 S A S O C I A D O S RUT :76.575.840 -8 AURELIO GONZALEZ 3330 VITACURA R E V I S 1 0 N S COMM. DATE 2010 -31 8 /5/2010 a► 5701 SUNSET DR. SUITE i�� AUG 05 2010 SOUTH MIAMI FLORIC)A, 35143ter Cowsi lru(,Aion ( 1 ST FLOOR PLUMBING PLAN P -,1 2 %- �♦ AREA ' OF WORK /., \ . \♦ � s. ♦� i / / ka �__'----- ---_� -: `- J �! 1ST FLOOR PLUMBING PLAN WARNING! MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. SCALE: 1/8" = f -0" THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED REWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE PLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF :NZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE PRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISS HENZ ENGINEERING INC. I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHpRIZATION #3880 TO PROVIDE THE ENGINEERING SERVICE. fa S1 4 -11-1H7 EflGl UR.N, 1HC_ � ��� �,' CO[1SlJLTIf1G Ef1GIfl��ftS D VID A 6 -'H WT, P E 2320 NE 9th Street, Suite 200 „J ?�:' t., Fort Lauderdale, Florida 33304 TEE 0 59492 T 954,523.4933 DOFF OKD RI F954,523.5052 u www, henz,00m 4 9i�E " < "_.,;x� «� "�i "" PROJECT No.: 10012.00 architect NORBERTO ROSENSTEIN ARCHITECT INC. 126 S. FEDERAL HIGHWAY SUITE #r 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIbinfoarosensteinarchRectcom WEBS www.roeensteinarchdect.com STATE REGF_ NO. ARZ0016&74 NATL. RECz. NO. &&3178 COPYRIGHT © 2010 NORMRTO R08ENSTON AR--HITECT, INC. ALL RIGWTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY POW U,aTHO1.1T PEf " IISSION. DESIGNED l „ l DRAWN p5 / % / i i � /,, ,// FWA CHECKED I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. 00 elt ®n + len iz A R Q U I T E C T 0 S A S O C I A D O S RUT :76.575.840 -8 AURELIO GONZALEZ 3330 VITACURA R E V I S 1 0 N S COMM. DATE 2010 -31 8 /5/2010 a► 5701 SUNSET DR. SUITE i�� AUG 05 2010 SOUTH MIAMI FLORIC)A, 35143ter Cowsi lru(,Aion ( 1 ST FLOOR PLUMBING PLAN P -,1 2