Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-723-019
aL ROLL MTL ROLL —UP DOOR 11' -6" ALUMINUM METAL DOOR ALUMINUM /GLASS DOOR S.C. WD DOOR METAL DOOR METAL DOOR STOREFRONT METAL DOOR S.C. WD DOOR 6' -0» DOOR 5' -6„ 6' -0" 3' -0" ' -O" 3' -0" 3' -0" 3' -0" 3' -0" 4' -0" 2 9" 2' -9» 3' -0" Ole cp N / O O O j/ j/ C7 O O 00 I 0 0 0 ® 0 0 0 ® o 1 DOOR , EVAT ONS : = l'—Op' METAL FRAME METAL FRAME METAL FRAME METAL FRAME A16IJM4NUM FRAME 3' -4" 5' -10" 6' -4" 4' -4" Size Thick Type N Fin. N N N I I I N I 1 0 101 i ice- i i 11' -6 "x 12' -6" 1,75" O O O O O — — — EXISTING — METAL ROLL —UP DOOR NOTE 1 102 GENERAL NOTES 1. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO ANY CONSTRUCTION AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 2. ALL WOOD IN CONTACT WITH MASONRY TO BE P.T. 3, ALL WINDOWS AND DOORS SHALL HAVE PRIOR PRODUCT APPROVAL AT TIME OF PERMIT APPLICATION AS PER F.B.C. 2004. CONTRACTOR TO PROVIDE SHOP DRAWINGS AT TIME OF PERMIT SUBMITTALS. 4, ALL WORK TO COMPLY WITH ALL LOCAL, STATE, NATIONAL CODES AND REGULATIONS HAVING JURISDICTION OVER THIS PROJECT. 5. THE SUBFLOOR MUST BE FLAT, CLEAN AND DRY. THE UNEVEN NE5 OF THE FLOOR MUST NOT EXCEED 1/4" WITHIN A 10' RAIUS. ALWAYS USE A VAPOR BARRIER ON CONCRETE INSTALLATIONS PER MANUFACTURERS SPECIFICATIONS. 6. ALL PERIMETER WALLS AND FIXTURES MUST HAVE A 3/8" TO 1/2 " EXPANSION SPACE TO ALLOW FOR THE FLOOR TO EXPAND AND CONTRACT . ALL COLUMNS, PERMANENT WING WALLS, AND IN FLOOR ELECTRICAL OUTLETS MUST HAVE AN EXPANSION SPACE OF 3/4 ". TYPICAL DOOR NOTES 1. ALL INTERIOR DOOR WIDTHS TO BE 1 3/8" HOLLOW CORE UNLESS OTHERWISE NOTED. 2, ALL EXTERIOR DOOR WIDTHS TO BE 1 3/4" UNLESS OTHERWISE NOTED. 3. PROVIDE MIN. 3 HINGES PER DOOR W/ SECURITY NON REMOVABLE HINGES FOR EXTERIOR DOORS BY STANLEY OR APPROVED, EQUAL 4. EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. AS PER NFPA 101 5, UNLESS OTHERWISE NOTED ALL DOOR HARDWARE SHALL BE HANDICAPPED ACCESSIBLE. 6, ALL DOORS SHALL COMPLY WITH F.B.C. 2007 AND N.F.P.A. 2000 — 7.2.1 & 12.2 7. ALL DOORS SHALL HAVE LEVER OPERATED MECHANISMS.', 8, DOORS SHALL BE ARRANGED TO BE OPENED READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED. LOCKS IF PROVIDED SHALL NOT REQUIRE THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE INSIDE OF THE BUILDING, PARTITI ❑N NOTES DO NOT ATTACH DIRECTLY TO METAL ROOF DECK, ALL FRAMING TO BE ANCHORED TO TOP CHORD OF THE JOIST AND BRACED TO THE BOTTOM CHORD AT A PANEL POINT AND TO BEAMS, SUPPORT ALL CEILING SUSPENSION SYSTEMS AND ALL BULKHEADS BY COLD FORM METAL FRAMING. CONTRACTOR SHALL SUBMIT COLD FORM METAL SHOP DRAWINGS SHOWING LAYOUT, SPACING, SIZES, THICKNESS AND TYPES OF COLD FORMED METAL FRAMING. 2x4 JAMB METAL STUDS Ld architect G.W.B. BOTH SIDES NORBERTO ROSENSTEIN REFER TO WALL CONST. ARCHITECT INC. LEGEND. METAL FRAME - REFER TO ARq-IMTURE - INTffM DESI(�I - PLANNING DOOR SCHED. 126 S. FEDERAL HIGHWAY 4 I N T MTL DOOR JAM D T L. SUITE # 202 3 " =1' DANIA BEACH, FLORIDA 33004 5/8" G.W.B. ON 1" METAL Z FURRING @ 24" O.C. PH: (954) 922 -6551 CMU WALL FAX: (954) 922 -7388 CONT SEALANT EMAIL :info•rosensteinarchitect.com WEB: www.rosensteinarchitect.com INSTALL FRAME AS PER PRODUCT APPROVAL DATA. STATE REG. NO. AR0016674 4 ' CONTRACTOR TO SUBMIT NATL. REG. NO. 69178 PRODUCT APPROVAL DATA. - ' I BUCK ANCHORAGE IN COPYRIGHT © 2009 NORBERTO ROSENSTEIN ARCHITECT, INC. ACCORDANCE WITH PRODUCT ALL RIGHTS RESERVED. THIS DOCUMENT APPROVAL BUT IN NO CASE OR PARTS THEREOF, MAY NOT BE REPRODUCED n LESS THAN 1/4" DIA. TAP IN ANY FORM WITHOUT PERMISSION. ANCHOR CONS. @ 12" O.C. MIN. EMBED 1 3/4" INTO THE CONCRETE DESIGNED //�� /�� / N. R. / Kr CONT. CAULKING DRAWN S.S. PLASTIC "J" STOP BEADS 5/8" G.W.B. ON 1" METAL Z FURRING @ 24" O.C. CHECKED KI ID DOOR_ FRAMES ELEVATIONS 3 NOTES N T „CMU DOOR JAMB DETAIL 2 SCALE. 1 /4 = 1 —0 N.T.S. SCALE. 3 — 1 0 I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER Hardware Sets MY SUPERVISION, AND TO THE BEST Door No. Room Name Room No. Door Frames Hdwr. Set Remarks Size Thick Type Mat'I. Fin. Type Mat'I. Fin. 101 SHIPPING 107 11' -6 "x 12' -6" 1,75" 7 MTL PAINTED — — — — EXISTING — METAL ROLL —UP DOOR NOTE 1 102 STAIR 110 4' -0 "x 7' -0" 1,75" 5 MTL PAINTED D MTL PAINTED — EXISTING — FR 1-1/2 H NOTE 1 103 STAIR 110 3' -0 "x 7' -0" 1,75" 1 MTL PAINTED A MTL PAINTED — EXISTING — FR 1-1/2 H NOTE 1 104 STORAGE 104 3' -0 "x 7' -0" 1,75" 1 MTL PAINTED A MTL PAINTED 3 NEW — FR 3/4 H — SEE HARDWARE SCHD NOTE 1 105 SALES 107 5' -6 "x 7' -0" 1.75" 8 MTL PAINTED B MTL PAINTED 6 EXISTING — FR 1-1/2 H — SEE HARDWARE SCHD NOTE 1 106 MECHANICAL 107 3' —O "x 7' —O" 1,75" 1 MTL I PAINTED A MTL PAINTED — EXISTING — FR 1-1/2 H NOTE 1 107 STORAGE 107 6' —O "x 7' -0" 1.75" 4 MTL PAINTED C MTL PAINTED 5 EXISTING — FR 1-1/2 H NOTE 1 108 STORAGE 103 3' —O "x 7' -0" 1.75" 3 MTL PAINTED A MTL PAINTED 3 NEW — FR 3/4 H — SEE HARDWARE SCHD NOTE 1 109 MENS RR 106 3' -0 "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 4 EXISTING — SEE HARDWARE SCHD NOTE 1 110 WOMENS RR 105 3' -0 "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 4 EXISTING — SEE HARDWARE SCHD NOTE 1 111 STORAGE 103 3' -0 "x 7' —O" 1 MTL PAINTED A MTL PAINTED 3 NEW — FR 1-1/2 H — SEE HARDWARE SCHD 112 DISPLAY 109 3' —O "x 7' -0" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 113 STOREFRONT 101 6' -0 "x 8' -0" 1.75" 6 ALUM ELREPAIINTED C REPAINTED E ALUM EL 1 EXISTING — SEE HARDWARE SCHD 114 STOREFRONT 101 6' -0% 8' —O" 1.75" 6 ALUM ELREPAIINTED C E ALUM E REPAIINTEDTIC 1 EXISTING — SEE HARDWARE SCHD 201 STAIR 208 3' —O "x 7' -0" 1.75" 1 MTL PAINTED A MTL PAINTED — EXISTING — FR 1-1/2 H NOTE 1 202 STAIR 208 4' —O "x 7' —O" 1.75" 5 MTL PAINTED D MTL PAINTED -- EXISTING — FR 1-1/2 H NOTE 1 203 LOBBY 213 5' -6 "x 7' -0" 1.75" 8 MTL PAINTED B MTL PAINTED 6 EXISTING — FR 1-1/2 H — SEE HARDWARE SCHD NOTE 1 204 LOBBY 213 3' —O "x 7' -0" 1.75" 3 SC WDI PAINTED A MTL PAINTED 3 NEW — SEE HARDWARE SCHD NOTE 1 205 NOT USED — — — — — — — — — — — 206 OFFICE 209 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 7 NEW — SEE HARDWARE SCHD NOTE 1 207 NOT USED — — — — — — — _ — — — 208 CORR 211 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 8 EXISTING NOTE 1 209 DATA 212 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 8 EXISTING NOTE 1 210 ELEC 210 3' —O "x 7' -0" 1.75" 1 MTL PAINTED A MTL PAINTED 3 NEW — FR 3/4 H — SEE HARDWARE SCHD NOTE 1 211 CORR 211 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED — EXISTING NOTE 1 212 LOCKERS 202 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 213 UTILITY 203 3' —O "x 7' -0" 1.75" 9 SC WD PAINTED A MTL PAINTED — EXISTING — LOUVER NOTE 1 214 TECH 215 3' —O "x 7' —O" 1.75" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 215 TECH 216 3' -0 1Ix 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 216 MENS RR 204 3' -0 "x 7' —O" 1.75" 3 SC WD PAINTED A MTL PAINTED — EXISTING NOTE 1 217 WOMENS RR 205 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED — EXISTING NOTE 1 218 VISUALOFFICE 206 3' —O "x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED — EXISTING — REPLACE FRAME NOTE 1 219 DISPLAY 207 3' -0 'x 7' -0" 1.75" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 220 CONFERENCE 214 3' -0 "x 7' —'0" 1.75" 3 SC WD PAINTED A MTL PAINTED 2 NEW — SEE HARDWARE SCHD NOTE 1 221 STOREFRONT 201 6' —O "x 8' —O" 1.75" 6 ALUM ELREPAINTED C E ALUM ELECTROSTATIC 1 EXISTING — SEE HARDWARE SCHD 222 STOREFRONT 201 6' -0 "x 8' -0" 1.75" 6 ALUM ELREPAIINTEDO E ALUM ELECTROSTATIC INE 1 EXISTING — SEE HARDWARE SCHD Casaideas OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. SET #01 r ■ Doors: 1 114, 221, 222 elton + leniz 1 Rim im Cylinder 20 -057 626 SC 1 Jackson CVR Exit Device HH 2086 NIGHT LATCH US28 MISC CROSS BRACING ® PIPE COLUMNS 2" X 3" X 3/16" SUPPORT STEEL 2" X 3" X 3 16 ARQUITCCTOS ASOCIADOS SET #02 — Display /�' r= Doors: 112, 212, 214, 215, 219, 220 1/2 X1 /2X1 /8 ; RUT 76 575 840 8 1 Lockset AL80PD SAT 10 -025 626 SC WELD 3" —,,,_ __,___ 1 Dame Stop 441 US26D RO i AURELIO..GoN sA3 3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST VITACURAe' '* 3 Door Silencers 608 GREY RO 2 X 2 a 2" PIPE''; -- SET #03 COLUMN Doors: 104, 108, 1 1 1, 204, 210 g' 3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 1' -6» RAIN''.y° 1 Lockset AL80PD SAT 10 -025 626 SC CAP 1 Dome Stop 441 US26D RO (TYP.) 1 Door Closer D -3550 STD W PA BRKT SN 689 RY 6 —0 3 Door Silencers 608 GREY RO �/ ROOF 6" S / PACE SUPPORT LEGS e SET #04 — Existing AS REQUIRED LEVEL Doors: 109, 110 BY EQUIPMENT SEE PIPE SUPPORT LEG DETAIL 1 Mortise Dummy Cyllinders CYL 626 MISC SET #05 A.C.C.U. SUPPORT FRAME DETAIL Doors: 107 N. T. S. 1 Cylinder Core 23 -030 626 SC SET #06 Doors: 105, 203 2 Surface Bolt 278D 6" US26D HA TYPICAL SLAB ON GRADE 1 Exit Device 12 8715 E ETL 32D SA CONSTRUCTION: 4" THICK CONCRETE FLOOR W/ 6X6 SET #07 W1.4 X W1.4 W.W.M.MESH Doors: 206 ON 6 MIL VISQUEEN OVER R E V I S 1 0 N S 3 Hinges FBB179 4 1/2 X 4 1/2 US26D ST 95% WELL COMPACTED, 1 Dome Stop 441 US26D RO CLEAN AND TERMITE TREATED COMM. DATE 1 Lockset AL53PD SAT 10 -025 626 SC EXISTING 8 CONCRETE FILL. MINIMUM CONCRETE 3 Door Silencers 608 GREY RO BLOCK WALL STRENGTH SHALL BE: 2010 -31 8 -5 -2010 1/2" EXPANSION JOINT fc =3000 psi. SET #08 MAT. TO FORM EXP. JOINT (VERIFY IN FIELD) Doors. 208, 209 1 Mortise Cylinder 30 -001 1 1/8" 626 SC NEW 4" CSLAB SLOPE FIN. GRADE C4"! Y G � U .I I�li{�i�11f as T.B.D. IN FIELD BUILDING DEPT. Cai STRUCTURAL SECTION IV ,'PPR°VCQ BY: 701 SUNSET DRIVE — EXSTG. FOOTING NOTE 1: — � — ��:� ► -w .A.�.�,���,a< � r� SUITE B —10 DOOR PANEL AND FRAME TO BE PAINTED RED — SW 6868. g NEW SLAB TO WALL DETAIL SCALE: 1/2 "= 1' -0" SOUTH MIAMI mm _:..,,.�.. a.:.. ;... ,. _.r. _ _:1 -. < -. N.r: FLORIDA, 33143 DOOR Y F SCHEDULE } =ar.w,wW ._.�� .�.,._�,.�.: •� ..w..:�r �..�.m��a _9�. ��.,Y�.w�.y���x�.�. 8c DETAILS �+ ,{. tf ,1 v��Ydp�,f iKl1"I j�'si�QI' 4�a'•il <`;i� �'�� (� Ci a1, {jN Y iF�T�tl� �U��Ui ' ��l a� #�1 �" � l RECEIVED l; f AUG 00" 2010 Turner Construction Co. A— 8.1 13 61DOOR SCHEDULE 7 HARDWARE SCHEDULE N.T.S. T.