Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-723-007
I- COMMON PATH - -- °IsPLAY- — — DIST. 99' -5" �- ~^ VISUAL OFF I 206 � I �+ I WO"RV I CO I I I 5 -° f F- - - - - - ----� \ I I 0 �I N MEN �RE57g04 ki 5 -0" TECH I 010 I - - - - \� / I I I / - TECH I s UTILITY Q O., L L / I I SALES I / LOCKERS / 202 / \ FE "R." I — — — - ` r _ I I T \ \ �' / L21 / / I 7\\ ,/ C,ONFE ENCE � All O, < I cb ,I EL V 1 / LOBB ?, OFFICE 209 g 0 / "N's hh i / 1 6 tlDh 0 � N I C? a, N d- 1 0 �GG I I SECOND FLOOR LIFE SAFETY PLAN BASIC CRITERIA CALC. EGRESS CAPACITY A. PRIME CODE OCCUPANCY APEF. OCUFFANT OCCUPANTS 1.FLORIDA BUILDING CODE (FBC) 2007 (S17 -ROSS) LOA[ + "S ") 2.FBC CHAPTER 11 FLORIDA ACCESSIBILITY TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN SEMI - RECESSED CABINET PER NFPA 10. CODE FOR BUILDING CONSTRUCTION 2001 SALES (201) 10,132 1/60 169 3.NFPA 101 LIFE SAFETY CODE 2003 LOCKERS (202) 412 1/50 9 B. TYPE OF CONSTRUCTION UTILITY 203 46 1/300 1 1.INTERIOR RENOVATION EXISTING BUILDING OFFICE 206) 332 1/100 4 2.FBC CONSTRUGTION TYPE TRAINING (208) (NET)378 1/50 8 3. FIRE SPRINKLERED BUILDING OFFICE (2 9) 1,653 1/100 17 ELEC. ROOM (210) 117 1 /300 1 C. OCCUPANCY CATEGORY DATA (212) 103 1/300 1 1.FBC MERCANTILE GROUP M CONFERENCE 214 357 1/100 4 2.FBC STORAGE GROUP S TECHNOLOGY 215 91 1/100 1 3.FBC BUSINESS GROUP B TECHNOLOGY 216 48 1/100 1 TOTAL 216 REQUIRED EGRESS WIDTH PER PERSON LEVEL: SECOND DOORS = 0.2 "x 216 PERSONS = 43.2" STAIRS = 0.3% 216 PERSONS = 64.8" PROVIDED EGRESS WIDTH PER PERSON LEVEL: SECOND DOORS = 192 " /0.2" = 960 PERSONS STAIRS = 117 " /0.3" = 390 PERSONS LIFE SAFETY LEGEND FEE, 1 H FIRE RATED WALL ---------- - - - - -- U FIRE EXTINGUISHER CABINET 2H FIRE RATED WALL - - FK_B_1 FIRE DEPARTMENT KNOX -BOX 0-1 9 EXIT SIGN "EMERGENCY LIGHT ® SMOKE DETECTOR FACIP FIRE ALARM CONTROL PANEL In SPEAKER STROBE NOTE: 1.SEE SHEET A -10 FOR WALL TYPES 2.REFER TO FIRE ALARM & SPRINKLER DRAWINGS FOR DETAILS LIFE SAFETY NOTES la. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN SURFACED- MOUNTED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "S ") 1b. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN SEMI - RECESSED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "SR ") 1c. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN RECESSED CABINET PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "R ") 1d. PORTABLE FIRE EXTINGUISHER MULTIPURPOSE DRY CHEMICAL TYPE, UL RATED, 10 LB NOMINAL CAPACITY IN RECESSED ENAMEL -STEEL CONTAINER PER NFPA 10. COORDINATE LOCATION AND REFER TO SPECIFICATION FOR FINISH AND MATERIALS (TYPE "E ") 2. LOCATE ONE (1) TYPE FIRE EXTINGUISHER IN EACH FIRE HOSE VALVE EXTINGUISHER CABINET ON EACH FLOOR. 3. REFER TO DETAILS FOR RECESSED & SEMI - RECESSED CABINET DETAILS. 4. ONE FIRE EXTINGUISHER IS REQUIRED PER EACH 2500 SF OF FLOOR AREA, BUT NOT LESS THAN ONE TO EACH PATH OF EGRESS OR WITHIN A TRAVEL DISTANCE OF 75 FEET. 5. SUPERVISED AUTOMATIC FIRE SPRINKLER SYSTEM PROVIDED THOUGHT THE BUILDING IN ACCORDANCE WITH NFPA 13 2 I LIF� SAFETY NOTES architect NORBERTO ROSENSTEIN ARCHITECT INC. ARCFIfECNAE - NRRoH DESK! - PLANMlG 126 S. FEDERAL HIGHWAY SUfTE # 202 DANIA BEACH, FLORIDA 33004 PH- (954) 922 -6551 FAX: (954) 922 -7388 EMAIL :info•rosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2009 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. i� %/ DESIGNED / /;; !� ME DRAWN % m D`/ CHECKED% %„ THEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. elton + leniz A R Q U I T E C T 0'19'1 A` -S� O� O� P O S � o- -r;4 �i4b9lp i4 'f"`t RUT :76.575.,440'-,8\\0k AURELIO GON 4,k 138`30, VITAGURA ' ,. "" "� " f�M � � Lidt-• 1 w�f 5 t r R E V I S 1 0 N S COMM. DATE 2010 -31 8 -5 -2010 5701 SUNSET DRIVE SUITE B -10 SOUTH MIAMI FLORIDA, 33143 ) U-000" I.. RE .' I V . A t,3 05- 2010 Tuffto .rrisr A 2.2 °F 13