10-1027-013Eel a 'Ir�la�� \�lT��> ■��] 1. (EXISTING FC1 7200 MICRO) FIRE ALARM CONTROL PANEL IS AN ADDRESSABLE SYSTEM TO BE POWER LIMITED AND HAVE BATTERY BACKUP. 2. BUILDING IS (AN EXISTING 3 STORY STRUCTURE). 3. BUILDING (IS 100 %SPRINKLED). 4. OCCUPANCY (32,000 SQUARE FEET MERCANTILE TENANT SPACE WITH A 2 STORY ELEVATION). THE REMAINING BUILDING IS A 3 STORY STRUCTURE. 5. SYSTEM AND INSTALLATION TO COMPLY WITH LIFE SAFETY NFPA101 2006, NATIONAL FIRE ALARM CODE NFPA 72 2002 EDITION, NEC -NFPA 70 2008 EDITION, AND FLORIDA FIRE PREVENTION CODE -2007 EDITION, NFPA(1) UNIFORM CODE 2006. 6. THE DESIGN INSTALLATION COMPLIES WITH FBC 11- 4.28.3 7. WIRING MINIMUMS; INITIATING CIRCUITS 18/2 FPL INDICATING CIRCUITS 1412 FPL (NAC) 8. CONDUIT IF REQUIRED WILL BE 1/2" MINIMUM 40% FILL MAX. 9. ALL DEVICES ARE TO BE MOUNTED PER NFPA GUIDELINES OR ADA WHERE REQUIRED. 10. SYSTEM COMPONENTS SHALL BE U.L LISTED AND COMPATIBLE. 11. CIRCUITS TO BE CLASS B STYLE Y. 12. AUDIBLE SIGNAL SHALL BE A MINIMUM OF 15 DB ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 DB ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS (WHICHEVER IS GREATER), MEASURED 5 FT AFF IN THE OCCUPIABLE AREA. 13. EACH STROBE SHALL BE ADEQUATE TO PROVIDE REQUIRED COVERAGE. SINGLE SYSTEM IS MONITORED FOR INTEGRITY PER NFPA72. 14. THIS SYSTEM IS MONITORED BY AN EXISTING REMOTE SUPERVISING STATION. 15. INTERCONNECTED FIRE ALARM CONTROL PANEL AND DEVICES SHALL BE ARRANGED TO FUNCTION AS A SINGLE SYSTEM AND MONITORED FOR INTEGRITY PER NFPA72. �,ki"aTl�r1 "i'IT�� Bt�I/.7rrt,.7r�1 INSTALL FIRE ALARM DEVICES AT REFERNCED PROPERTY. FACP AND RPS ARE PROTECTED BY A SMOKE DETECTOR. SCOPE OF WORK IS LIMITED TO WHAT IS PROVIDED ON THE FLOOR PLAN AND RISER ONLY. MANUAL PULL STATIONS- THE ACTIVATION OF A MANUAL PULL STATION SHALL INITIATE AN "ALARM" CONDITION IN THE BUILDING FOR EVACUATION PURPOSES. AT NOT LESS THAN 3-1/2'& NOT MORE THAN 4 -1/2" AFF. AN AUDIBLE ALARM TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANEL AND THE LOCATION OF THE ALARM SHALL BE DISPLAYED, IN ENGLISH, AT THE CONTROL PANEL AND ANY REMOTE ANNUNCIATOR. THE ALARM SHALL ALERT THE BUILDING OCCUPANTS BY WAY OF HORN /STROBES AND /OR STROBE DEVICES. AN ( "ALARM" TO EVACUATE THE ENTIRE BUILDING CAN BE GENERATED FROM THE FIRE ALARM CONTROL PANEL.) THE ALARM CONDITION SHALL BE REPORTED TO THE REMOTE SUPERVISING STATION BY WAY OF DIALER. SMOKE DETECTOR& THE ACTIVATION OF A SMOKE DETECTOR SHALL INITIATE AN "ALARM" CONDITION IN THE BUILDING FOR EVACUATION PURPOSES. AN AUDIBLE ALARM TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANEL AND THE LOCATION OF THE ALARM SHALL BE DISPLAYED, IN ENGLISH, AT THE CONTROL PANEL(S) AND ANY REMOTE ANNUNCIATORS. THE ALARM SHALL ALERT THE BUILDING OCCUPANTS BY WAY OF HORN /STROBES AND /OR STROBE DEVICES. AN ( "ALARM" TO EVACUATE THE ENTIRE BUILDING CAN BE GENERATED FROM THE FIRE ALARM CONTROL PANEL.)THE ALARM CONDITION SHALL BE REPORTED TO THE REMOTE SUPERVISING STATION BY WAY OF DIALER. CEILING MOUNTED SMOKE DETECTOR SHALL NOT BE LOCATED IN A DIRECT AIRFLOW, NOR CLOSER THAN 3' FROM AN AIR SUPPLY DIFFUSER DUCT DETECTORS- ANY AHU ABOVE 2000 CFM AND RETURNS RECIRCULATING OVER 15,000 CFM OR SERVING MORE THAN ONE FLOOR SHALL BE PROVIDED WITH A DUCT DETECTOR. THE ACTIVATION OF A DUCT DETECTOR SHALL INITIATE A "SUPERVISORY" CONDITION AT THE FIRE ALARM CONTROL PANEL. AN ELECTRONIC SIGNAL WILL BE SENT TO THE EXISTING REMOTE SUPERVING STATION BY WAY OF DIALER. AN AUDIBLE SUPERVISORY TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANELS AND THE SUPERVISORY LOCATION SHALL BE DISPLAYED, IN ENGLISH, AT THE CONTROL PANEL(S) AND ANY REMOTE ANNUNCIATORS. SUPERVISORY SIGNAL INITIATING DEVICES. (TAMPERS, PIV AND ETC.) THE ACTIVATION OF A SUPERVISORY SIGNAL INITIATING DEVICE MODULE SHALL INITIATE A "SUPERVISORY TROUBLE" CONDITION AT THE FIRE ALARM CONTROL PANEL. AN AUDIBLE SUPERVISORY TROUBLE TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANEL(S) AND ANY REMOTE ANNUNCIATORS. THE SUPERVISORY CONDITION SHALL BE REPORTED TO THE REMOTE SUPERVISING STATION BY WAY OF DIALER. FLOWS ITCHES: THE ACTIVATION OF A SPRINKLER FLOW SWITCH SHALL INITIATE AN "ALARM " CONDITION IN THE BUILDING FOR EVACUATION PURPOSES. AN AUDIBLE ALARM TONE SHALL SOUND AT THE FIRE ALARM CONTROL PANEL AND THE LOCATION OF THE ALARM SHALL BE DISPLAYED, IN ENGLISH, AT THE CONTROL PANEL(S) AND ANY REMOTE ANNUNCIATORS. THE ALARM SHALL ALERT THE BUILDING OCCUPANTS BY WAY OF HORN /STROBES AND /0R STROBE DEVICES. AN (ALL -CALL" TO EVACUATE THE ENTIRE BUILDING CAN BE GENERATED FROM THE FIRE ALARM CONTROL PANEL.) THE ALARM CONDITION SHALL BE REPORTED TO THE EXISTING REMOTE SUPERVISING STATION BY WAY OF DIALER. LL 1 1. ADDED EXISTING RELAY MODULES FOR EXISTING ELEVATOR RECALL. ,1,2 2. PROVIDED ELEVATOR RECALL DIAGRAM. ,/13 3. PROVIDED ELEVATOR RECALL NOTES. System No.W -L -1001 September 07, 2004 (Formerly System No. 147) F Ratings ' 1, 2, 3 and 4 Hr (See Items 2 and 3) T Ratings - 0, 1, 2, 3, and 4 Hr (See Item 3) L Rating At Ambient - less than i CFM/sq R L Rating At 400 F - less than 1 CFM/sq It System No. C- A3.1001 August 23, 2004 (Formerly System No. 49) F Rating - 3 Hr T Rating - 0 Hr W Rating - Class I (See Item 4) SECTION A -A System No.W -3 -3081 Sepbnber 08, 2004 F Rating - 2 Hr T Rating - 1/2 Hr L Wo Am by -The 1.2.3 W 4 hr nre•ratW gypsm warm WdW wee a m* shah b mnMuctad d the materials "a th4 manner described in thA mdadd U)00 W U400 Srin Wea W Partition Designs In the UL Fire RsWana oboday, ads shall aduds the fobwhrg comtrumah features: A Studs - Will hemh6 may consist d Asher wood stuff (max 2 h Ike rated assemblies) nr and ape" saw. Wood Muds a �Wlaa of rem 2 by 4 M. lumber 1 16 M. OC with ram 2 by 4 s, kb., and pates era apes Ins. Sml studs a be min 3-S/6 m. whin by 1 -3/8 e. deep drannek spec"' max 24 m. OC. B. typolm Bond- • Nan 1/2«5(6 a. UOdt, 4 ft .Ws wale ware or tapered edgw The aypaan -Itca d type, thiduess, number of layers, fastener type and ahM Wamatbn hem be as specelad In the M w"I U300 W 0400 Sonar Design in the UL Fbe Audience Dhdory. Max dlam or so-" 26 u. 2. Through W rretrnd - One martk pot, perdu W tubliq lorNd ether co osotriaty W safnbtwM wMu'r Bra MnaC syarem.The MAX 2 h.gge, coduftW ob to wpand an bothdoa of bemin one as. follow mntype a x 2 M. Moe. me ph e, tubkq a rt b" ay be usd Wm bon sidse et wag esssmby. The falahMng type ads aces � meads �} tWdues a tub" may be used: A. Sad Pipe - Nam 24 a. diem ("an~ Sdedus 10 (W heavier) .bad pipe. 0.1i m pip. - Mom 24 it diM (W MSW) Wyhpe wtot (W heMar) aM bar rob pipa, tam 12 t arm (w amasen a Clan SO (er heavier) ductile hoe possum plan. C. Condut - Nom 6 m. 41an (W sw" Mee mndut «fan 4 a diem I. asarP Masi allpofcal metMC Wto" m Copper To " • Nom 6 m, dam (or Am" Type L I. heavier) cower tu0kq E. Cooper Pape . Nom 6 m. dam (W wrraW) Regular (W heavlan copper PIM F. Thorough Penetrating product* - Flexible Metal Poe; • The tarwmg types er a" Merger meal an pork; may be und: I. Nom 2 e. darn (or wpelan A W Aexbt metal go poring. prshe covering an piping may W may not be removed on boar sNa W MW W wa4 awmbry. OMEGA FUEX PC 2. Nom 1 M, diem (W one" steal flexible metal on piping. Maine musing an piping may W may nor be removed on both Md. of hoof or "rag Assembly. TTEFLEX CORP, A BUNDY CO 3, Nom 1 e. den (W anal«) steal Mxble moral gas piping. Pratte cover; s piping may or may fat be removed ea both shin of Now W wa4 ssaemWy. WARD MW INC 3. Fa,Vod or Cavity MshmP - auk a SeWnt - MM 5/8. 2.1/4,1.7/6 ads 2.1/2 s. thkknass of auek W sulaM for 1, 2. 3 and 4 hr rated assembles, respectively, applied wthm annuls, Meth with both surf-of -1. Mm 114 W. diem bead of auk W sealant appeed to gypsum baWpenedam owerfepe at posit mrxeort loth am both Wes W wed. The hourly F ReWrg of the fn," system is dependent upon fie be^in Meta of the wall a Wy b which it is entitled, As sham In the Mae" ape. TM Murk' T Rating of the Angles, system Is dependent up" the type or Mae, of the pipe W mnduft and the hourly M nth; et the wee assembly s which t.lua4d, n tabulated below: �'�,t��lCtlt•ns�s6� +Wha copper pips Is used. T Rath; is 0 hr. 3M COMPANY - CP 23W8+ ouk W FB -3000 Wr -lsK *Ram; the UL a.rBkwBon Meridq K 1. Floor or Wall Assembly - Min 4-1/2 In. Nadi lightweight or normal might (10D -150 pd) sues. Wag may aim be WnMn,ced or any UL Classified Coftaets BkCks* . Max dam of CIMAW Nxo lh opening Is 22.1/2 kip Sse Crxkrete Hcotlka (CAZT) category, In the Rre Ranprms DiKcory Ax name ot mexActsnrs. dA. Sus Sheen (Options), row Mown) -Rom 12 M. diem (W sm W) Schedule 40 (W heavier) sal pipe sleeve as IMO concrete Rota or well. Slew to be Matt whet or project max 2 M. tom tot astaee or Rom, or ran bah s rfoas of well. 1 Thro gh Psotrent - One mea0c pipe, Conduit or tubing Installed sorer cawMRrialy w OCOU& alty Walsh me flfW5W system. The arrmuler space bat"eri Pipe. mndult W tubing and periphery of opening stag be mm of 0 In. (point contact) to max 1.3(6 m. Poe, Wade or tubing to be fgdry supported on both sties of wan ssnmbly. The following types and area or meaNt "as, arose or loping may be used: A. Stein Pipe -Nom 30 inn Lam (W wnaltar) Sceduae IO (Wheavw) stes ppe. AL. Iron Roe • Nan lL Qum (W .roger) ads W dMle par pipe. & Cadult • Nan 6 m. dam (or eaaer) light sal conduit. C Conduit • Mom 4 m. diem (W "our) sea sew metallic tubing. 3. beEdg MatgnN . Pdyetihnere betker row «nom 1 a>. micoeaa ar u9hWpadksl aramlC (alumina place) Aber blanket, mkwal wool batt or glass Aber emulation material Land As a permanent Aim. Padding mats« a be leaw6 mom top s dace a flw W from both surfaces a Sad concrete or wnaea block wall as required to aaanmodsts the r".Wed Dadrtess W co Ak Al material (gym 4). As an alternate when max pipe else Is 10 In. diem and whin MAX amWar pace is I WW a min 1 In. thickness W 6ghaypsewd Commit Aber Marriott «miners wool bad padding mental may be recent min 1/2 in. from baton srrace of floor or, from eats side or sae Concrete ma. 4. Aff,Vold «Cavity Mat W - Char «Scent - Applied to fill the Annular qua W the mm thianafs storm In the following table: (a) BR - PoryethlMena backer lad. CF . Ceramic Aber Winker. GF . Gina Aber ifrdsbm MW . "Mew -wad WRt. (b) Caulk Installed Rush with top s«taa of floor or both s hats of wsa. (c) Caulk Installed flush with bottom saga W Roar or one area of mad (not -aMrte Work) md. 3M CONPAhN - CP 25WB+ caulk or FS -3000 WT Sealant. (The W Rating apples oMy wheen FS -3000 Wr sealant is used.) - Bearing the UL Classification Mamidg L Wa Assembly - tan 6 in (152 mm) thick rainmrced bgNaalgY «n0omms weWt (100 -SSD pcf W 1600.2400 kg/m3) wnaets wan. Wan may also be atazruaad a any uLaaaeftcl Concrete Becks- . Max diem W opening s 8 kL (203 mm). Sae Cowes elo rs (CAIM category in the Pre Reastance Directory for names of menASkflxrx. 2. able - One able ktitaMO ec aMnaey or coneeMriaay mirin opening. Mmmusr spas betwaen able ads priggery W opt" to be mm 0 m. (0 mm) (par CWxM) to ma 1 kL (0 mm to 25 mm). ab% to be ngldy supported on troth son W the wag. The foewing typos and am W able may be unit: A. Max 200 pair No. 22 AWG (W Manor) Copper conductor with po nirhM Gedr1M (PVC) Insulation and jadkebeq manta. & Max 1/C No. 350 kcmR (W SmageO Copper Conductor able with payetlhMena ()MPE) «PVCpdket. C Max 7/C N0. 12 AWG (W smaller} copper conductor paw and control aura WWI XtPE «WC Insulation with XLPE W PVC jadse. D. Max 3/C No, 3/0 AWG (W .nape} coppar or aluminum conductor SER codes with XLPE W PVC irtaxan and pcX1L E. Max A/C No. 2/0 AWG (a smaller} copper CoMM«, aluminum duo W ate dad TIC 90 able Willmar with" PVC jWUad. F. MDz 110/125 Row optic (F.0.) able with PVC Wou atiah and Jacket. G. Max 3/C with ground No. 8 AWG (or smaller} copper conductor NM able With PVC WWaBon Como jacket, Max RG/U coaxial able with fluorinated attrykfne mWatwp and jacket. I. Max 4 pair No. 24 AWG (or snaMr} Copper CondMW data Cobs with try" jac at and ixadanan. 1. Through Pension" product- - Amy cabin, Armored Cabs+ W Maal C1ed able+ can" Claaafied veer tow Tgro gh Penatratkq Produ t Ctapory. Sa Through P WM" Product (XHLY) Category In tow Fie Resistance Directory for Mmes W manuhdYwR 3. All Vold or Cavity Matedal* - Caulk or Sealant - stmt 5/8 tin. (16 mm) tNdaes of caulk W salads applied within onnAus, Minh with bah efface of ws. own 1/4 In. (5 mm) dam bead of Caulk W sealant applied to able/woll mxerfice at point comet location an both Moo of wall. 3M COMPANY • IC ISNB, CP 2$We+ sulk «FMmOD Wr seaatK -Beano tow cA Classification Marking An System No.W -L -3110 September 07, 2004 F Ratings - i and 2 Hr (See Item 1) T Rating - 0 Hr SECTION A -A System No. C -A3 -3200 SEptember, 2004 F Rating - 2 Hr T Rating - 1/4 Hr SECTION A -A Systed" No.W -L -3061 September 07, 2004 (Formers) System No. 149) F Ratings - 1 and 2 Hr (See Item 1) T Ratings - 3/4, 1, 1 -1/2 and 2 Hr (See Item 2) L Rating At Ambient - 15 CFM/sq R (See Item 3) L Rating At 400 F - less than 1 CFM/Sq R (See Item 3) SECTION A -A L WAR Assembly - The 1 or 2 h fire rated gypsum wanbaM/6aed wan aobmw stlan be CwsmxtM of the matrices and In the mennar paeAed to the IMlvdtel U300 W W00 Serhss Wall and PMNbrt Designs In the U. Fire Resistance DI actor) and Muff xxk de the Ibl oving construction hsbses: A. Studs • Wan framing may con" of Anchor WOW studs W pal channel tudA wood studs a consist of tarn 2 by 4 In. lumber spaced 16 in. OC. Stein ends to be min 3.1/2 kL wide and spaced max 24 kL OC e. Gypwm Boero* - Thickness, type, number M uyen and hMa on; as rafF6ed In the Individual Wan and Partition Design. MAX dam of opening s 4.1/2 m. The M«ly F Noting of tow Arestop "M is equal to vie hasty/ in rating of the wall assembly kn "tact it s Installed. R Cabin -Max 4 In. diem Ught bundle of sown Installed acconot aay «an wore alry m opening. The annular apace between tow budN I Cables and the periphery, W six opm" to be hen, O m (part Contact) to a Maximum 1/2 m, Cables may or may not be rated through Aadbe pal coMult with or without vin11 coating, Cabin to be rigidly supported on both ■des Uwan use". Any combination of the floMm p types end plm of able may be Land: A. Max 150 pair No. 24 AWG (W smaller) Cooper CWdMO with pWyvirm4 chloride (PVC) kauladoh and prAeL B. Max I/C 350 kcmg (or small«) copper conductor able with ovs"n ced polyethylene (XLPE C.C. Max 3/C No. 2/0 AWG (W smaller) alumnae or Cooper conductor able with XtPE mNaUOn and PvcWOOL D. Max 7/C No. 12 AWG (W v &go Copper co ductor able with PVC Insulation end jacket & Max No. 18 AWG RG 61/U coaxial able with PVC Insulation and jacket. F. Max 3/C with grperM No. 12 AW S (or $Manor) RM able with PVC Wo ulatbn and jacket G. Through Penwaurq Rodud* , MAX 3/C No. 2 AWG (w $Manor) akenxwm W steel Cad Armored COW W aluminum W ored dad Metal Cad able* with eoppar arducW7, ALFIXX CORP 3, nn,Void or Cavity MateratO - ado, a Sagoot - MM 5/8 m. thickness W Al material &Wed wetNn annulus, flush with each surface of wag. own 5/8 in. tW6axss of flff material applied Into IMersUtu W cables on both Index of wag. 3M COMPANY • C P 25W5+ Caulk w FS•3000 Wr wads *Bearing the IA. CassM1at om Morning 2. R0or W WIN Assembly - Mm 4-1/2 in. (114 mm) Dad, reinforced Hg tmght «rums( waght (IOD6I50 pd or IWO-2400 kg/m3) concrete. Poor assembly may elm be ConstnuClted of any mm 6 kL (152 non) thick UL Classified hdlk) - 11 process Corwaa (MRS* . Wall may also be constructed of AM U. 08"Ned C«wae 111063- . Max dam a opening 6 M. (152 mmm Sae Cori a BlOdd (CAYT) ads Precast Coweta ilea. (CFTV) Categona In Fire RMMarxs Dkactay for name W Manufacturers. 2. Stec Sinew (Optional} - Nom 6 kL (152 him) dam (W smaller) Wed," 10 (or hewer area Mom cast W ground Into 11- W wan assembly. Sorel screw MY be keNaM Mss, or may pppd rnax 2 kL (51 mm) beyond the floor W me sraCn. 3. Cosa - A99re0+1e cTOn- secbool area of Cables In opening to be max 49 dsrnR W the area made the skew or opening. Ar ular space bebvan acres and pargMry of pang W shave Mat be min W 0In. (point contact) to max 21n, (0 mm to max 51 mm) Cabin to be riplory, supported on Dom era W NOW W WAR assembly. MY Combination W tow fotloaeg types and am W able may be used; A. Max 200 pair No. 22 AWG (« snaller) Copper poMMW with por vmeM c brows (PVC) hralsb,i ad jacketing mstarsi. 8. Max I/C No. 750 ktmll (or =ago Cooper eaducty able with cross -laved pdpathyisre (MPE) jacket. G Max or No. 12 AWG (« s lleO copper arMucor powar and Cor&ig cobs$ wink MM w PVC ksdaten ohm XtPE W PVC AdML D. Mal, 3/C No. 310 AWG (or smallo copper or aluminum conductor SEA coca with PVC kms$aban sup Jacket E. Max 3/C No. 2/0 AWG (W smaller) copper conductor PVCjaWaed akmmnan cad W a" Cad TECX 90 able. F. Max 1101125 now optic (F.0.) able with PVC kMiatlah and jacks. G. Max 31C with grand No. 8 AWG (W romplon copper CoMuaor NM able with PVC Insulation MO }slot N. RG/U 004xis able with fluomsted ethyNM (FE) «PVC mutation std paws. I. Max 4 pair No. 24 AWG (or $matter] copper pondtKtW data able with Nyter jeeke and Nadabon. I. Max three co mil- No. 12 AWG (W sroMr) MK (W copper able with pdyy4ri cderfda m ulatton and jackat maw" - Through Penetrating product* • Any cables, Armored able+ or M" Cad able+ a rrerzly Classified user the Through PerNtrating Product category, See Through Penetration product (lacy) Category In the Flee Assistance Directory Nor Mmes of mamta(4vwr$ 4. nrestop System - The OeAHS of the flrestop syitan shelf be as fog": A. Pe' -king Matsal - Min 3 ln. (76 mm) thickness of min 4 pd (64 kWm3)mkwaf roc edam WoMO n Amoy packed Into opening as a permanent form. petting material to be recessed ham cop surface o now W top edge W sinew W from both surfaces W writ W both erdb of Wave a required to accommodate tow nqulMd thickness W p fill material. In moe Constructed W txxbw -Cor Cowin , padding Cow, padding material to be ct reaed hom top and bottom aorta= Of floor «peeve a Mguy1d to earommodp tow required tlYdaess W Alf material. B. KVold or Cavity Materials- • Caulk «Sala - tun 1/2 M. (13 mm) thicaoss of caulk W bawds applied within the antics, flush with cop sufaca of Aux W top edge W statue or Win norm sataass W.64 W bon ends of sons. In moos Conshicted W hollow -core condKe, min 1/2 In, (13 mm) thicken of onak or Basis m 4ppnW wthin the amMus, flush with top and button wKaM W Roo M WewS. Min 2/4 K (6 mm) diem ben of aunt applied to the penMnM(cona is or penatra t/9"ve Interface at the point ox"d Wow Wt the top solace or floor of both sufaas of wall W haow core porwea. 3M COMPANY - CP 2SWB +, IC i5WB cook W W300D WT 9nsM. * Bearing tow UL CassRlabar Msidrg + BAIRIN the to Usurp Mark I. WON AsnmW • The I W 2 h fire -rated gypsum wa0bea Wand will assembly au/ be Constructed W the Materials and In the manner dewiWd in the ideWdual U300 W UAW Sams wag «pstldat Designs In the UL Fire Resign Directory and self mWkde de foRavirq aMmudkn features: A. SBada - Wall hanerg may consist of either wood soda or psi Wnnal sBW, Wood studs to Consist W n0M, 2 by 4 mL lumber paced 16 m. OC with non 2 by 4 m. lumber aril plain and dos braces. Stec orris to be min 3.5/8 In. wide by 1.3/8 kL dap denials spaced MAX 24 m OC. & sypseae Ressd* - Nom 1/2 W 5/8 m. thick, 4 R wide with squaw or topped edges. The gypsum walRaaro type, thleaMss, number W layers AM wrest orientation Ass be s pedned m the mdvidual Will or paKmoh Design. Diem o Cira/ar though operwnp a be 3/8 mL a 5/8 eL tugs dun aMdo dim W able «ape bundle, C Faaasteet - When wood std taming N employed gypsum wallbard layers attached m each with camel posted nabs as specified In me individual Wad W Prirtwn Defen. When aes darns gds Karr inq Is employed, gypsum wallboard ateacled to Muds with Type S sin- Wgnrg, w6•rppNfp bkgre -head steel scram as peified In the iMNktal Wag W Perttkxs Despot. The hourly F frtMg elf own f4estop as too r pads a tlin koarM! Nn rafRg ear hits WaR aumnwy in wrnt ]t it in raspe& 2. Cables inupeemin o In 1�t Max Ma 3314 bundle Installed be gidy supported both ta of wag assembly. The folldving types and elm of cables may be used: A. Max ISO pat No. 24 AWG appal CondMor telephone able with polyvinyl daande (pVC hmdabah And jacket MWAI . When ms 25 pair telephone able s used,. T Rating is 2 br.Whof 50 to 150 pas tamp"" Lathe is wad in 1 hr pine mad seek T Ratrg r 2/4 hr.W Wes b a 350 Fos aewihotta cOft r weed In 2 her the read WaR, T Reteig is I hr. A. Max No. 10 AWG Multiple Copper Conduct« Type Mint (Rams') nownstallk sheathed able wIth, PVC Insulation wow poke matriaw Wine Type FM cable r rand, resoc T R>k� r Sal /2 hr. C Multiple fiber optical COMMUNCIUM able jeduad With PVC and hew; a MAX outside diem of 5/8 In. Nmtwt fiber optic able Is used, new T Us" Is 1 hr. D. Max 12 AWG mutt poMMW (max seven conductors) pow /kbbed able with Wm -bktd poiyedrylae (XIPE) Insulation Coe XtPE or PVC pdka maeratA When ruff connecter power /control amn Is uad, eat T Rating r 2 hr. E. Max four Conductor with ground No. 2 AWG (W smaMr} ahrrxnM SER tebes with pdyvk o Ch onde mammon and puke materials. 3. PnVoM or Cavity Mat rttr- - Caulk Bard ce Fumy • Caulk or putty AN material mdtasd to completely 80 anwhar pace between able and gyporn waiboard on both Odes or well ere with a min 114 In. diem bead Of aulk or putty applied to pe"Wer at able($) at is agrees from each We W tie we". 314 COMPANY - MP+ Sdx putty, CP 25M+ Caulk F8 -3000 Wr ssWU or Cable Wrap putty (Note: L Ramps apply only when CP 25Wa+ anak W M3000 WF sealant Is used.) - Bearing the UL Classification Mark 'INiIAh1i -DAD E C0 Ut-� 7 Y F i R E D E PART M E NT 5e U G. n -?,M =T F I RE AUVR M 1-11 FIRE SUPPRESSION WATER MAIN r-XT.--, e A 1,115111 '1 i MW it l MML NFPA 72; 70; 101 N *° * ohm