Loading...
09-914-00104 0 EXISTING (1) HR FIRE RATED PARTITION. /; WAX B -1 WAX Te n FF_ gROOM #5. ROOM #4. PB1 b 8' - 6' -1„ 2' -O„ 13' -5" 8-0 ° E TOP OF SOFFIT RECEPTION in TOP OF o CIS \ ELEV. 8" A.F.F. I DESK. COUNTER WAITING AREA. �°, LO EXISTING (AG ` 3 LOW PARTITION. 2 LOW PAR ITION. 2 k 9z 4i ) RESTR1 ` ht: 34 ht: 34 �s56 .... - - - - - -- D G T P 2 787.34 SQ FT. / A1 EF .� ..................°.................. ..........................>oN o CORRIDOR. 'Z 1 EXIST. ' ef TRAVEL Al E1 ENTRY. v DISTANCE E2 o� O :.. rITI .... ....... / / 54 -0 �. F -1 -1 " / / ELECT. Q' B -1 F -1 4 -8 PANEL. 0 00 1 B -1 if VESTIBULE' ❑ - WAX ° 2 WAX WAX I E3 • ROOM #3. ROOM #2. X. ROOM #1. DISPLAY. EXIST 0 F -1 2 „„ 2 0 L J B -1 32 X75 / / �� N 6' -5" 4' -0" 8' -0" 8' -0" 8' -0" 5' -3 °/ 0 ' °" "rT "' .STUDS 24" C/C PSUM WALLBOARD wQ CI_ �o Iw oa Z w M�TALSTUDS 4 ' WOOD @ 16" C/C 'SUM WALLBOARD EXISTING SUSP. ACOUSTICAL CLG. FTOP OF SOFFIT ELEV. 8" A.F.F. WAX WAX ROOM #5. ROOM #4. LOW PARTITION. . LOW PARTITION. ht:34" 00 ht:34" :.....:...:............ ° ................. .. o . . . . .. ...... . N . ... .... . . PROVIDE DOUBLE STUDS AT OPENING (TYP) 0 RECEPTION 00 DESK. T" t0 EXIST. FIRE EXT. 4 PROPOSED FLOOR PLAN SCOPE OF WORK. EXISTING RETAIL SPACE TO BE USED AS WAX SALON. MAXIMUM OCCUPANCY LOAD: 787.34 SQ. FT. /100 = 8. ALTERATION - LEVEL 2 (AS PER F.B.C. EXISTING BLDG). EXISTING (1) HR FIRE RATED PARTITION. MAXIMUM OF 1/2" DIFFERENCE IN LEVEL BETWEEN OPPOSITE SIDES OF ALL EXIT DOORS IN ACCORDANCE WITH NFPA 101 5- 2.1.3.3 PROJECT SUMARY. OCCUPANCY AREA. OCCUPANCY MEANS OF CLASSIFICATION. L • LOAD. EGRESS. BUSSINESS- 787.34 SQ FT. 1/100 SQ FT. NET REQ'D 1 DOORS GROUP "B ". B -1 787.34/100 =8 PROV 1 DOORS WAX SALON. EMERGENCY LIGHT FIXTURE(TYP.) TWOOD T. PARKING REQUIREMENTS. COMMERCIAL SPACES. RETAIL & OFFICE =1 SPACE FOR EVERY 300 SQ FT (787.34) = 3 SPACES. REGULAR PARKING PROVIDES = 3 SPACES. GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND ANGLES AND ALL OTHER EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK. CONTRACTOR TO ALSO VERIFY AND APPROVE ALL INFORMATION ON DRAWINGS. ACCEPTANCE OF THESE PLANS CONSTITUTES APPROVAL. PLEASE NOTIFY ENGINEER BY CERTIFIED MAIL OF ANY CONFLICTS OR DISCREPANCIES, IF ANY. 2. THE CONTRACTOR SHALL OBTAIN FROM ALL SUBCONTRACTORS THE FINAL APPROVED SITE AND LOCATION OF ALL OPENINGS TO BE PROVIDED FOR RESPECTIVE TRADES. HE SHALL BE RESPONSIBLE FOR LOCATION AND DETAILS. 3. OWNER AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING, BY CERTIFIED MAIL UPON COMMENCEMENT OF PROJECT. 4. THE OWNER SHALL BE SOLELY RESPONSIBLE FOR INVESTIGATION IN REFERENCE TO WHETHER STRUCTURE CAN BE BUILT ON SITE. PAYMENT OF THESE DRAWINGS CONSTITUTES ACCEPTANCE & AGREEMENT WITH THE FOLLOWING STATEMENT: NO PARTY SHALL INITIATE DELAY CLAIMS AGAINST EMILIO CASTRO & /OR E.C. ASSOCIATES, INC. LIABILITIES SHALL BE LIMITED TO FEES PAID TO THE DESIGN PROFESSIONAL. FIRE PROTECTION NOTES PROVIDE ( ONE ) CERTIFIED 2A -108C FIRE EXTINGUISHER FOR EACH GROSS BUILDING AREA OF 3000 SQ.FT. AND WITH A MAXIMUM TRAVEL DISTANCE TO REACH OF 75 FEET MOUNTING HEIGHT TO TOP OF EXTINGUISHER SHALL NOT EXCEED 48" AFF ALL INTERIOR FINISH MATERIALS TO BE INSTALLED SHALL HAVE A MINIMUM CLASS "C" FLAME SPREAD RATING EXISTING BUILDING HAS AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH FFPC & NFPA. DOORS NOTE: EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE CLOSET FLOOR LEGEND F -1 FLOOR: WALLS NEW LAMINATE FLOOR OVER L • EXISTING CERAMIC TILE. MARK (AS SELECTED BY TENANT) EF FLOOR: LIGHTING FIXTURE SCHEDULE EXISTING FINISH TO REMAIN B -1 BASE: FINISH BASE EMERGENCY LIGHT FIXTURE(TYP.) TWOOD T. ( OSMSELECTEDOBYFTEONOANT) NO ELECTRICAL, MECHANICAL AND PLUMBING WORK UNDER THIS PERMIT. LEGEND & SYMBOLS ® INDICATES EXISTING 8" C.B.S. WALL WALLS INDICATES EXISTING FIRE /SMOKE BARRIER PARTITION L • INDICATES EXISTING PARTITION MARK INDICATES NEW 3 5/8 ", 25 GA. MTL. STUDS FRAMING O ® 16" C/C WITH 1/2" DRYWALL FINISH EACH SIDE. LIGHTING FIXTURE SCHEDULE SYMBOL MATERIAL DESCRIPTION FINISH Q REMARKS EMERGENCY LIGHT FIXTURE(TYP.) H. T. W /BATTERY BACK -UP FRAME DOOR CONNECT AHEAD OF SW. E1 FRONT ENTRANCE. EXIT LIGHT FIXTURE(TYP.) 6' -0" 7' -0" W /BATTERY BACK -UP AL /GLASS AL. CONNECT AHEAD OF SW. FINISH SCHEDULE ROOM NAME FLOOR BASE WALLS CEILING L • REMARKS MARK LOCATION O DOOR OPENING SIZE MATERIAL 9 5 8 10 FINISH Q REMARKS W. H. T. DOOR FRAME DOOR FRAME E1 FRONT ENTRANCE. 3 4 7 6' -0" 7' -0" 1 3/4" AL /GLASS AL. GLASS. PAINT EXISTING DOOR. E2 3 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH %; PAINT EXIST CMU W/ EXIST D/W FURR 3 EXISTING DOOR. E3 VESTBULE. W 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH WOOD PAINT cm PAINT EXISTING DOOR. 1 WAX ROOMS 1, 2 & 3. 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH WOOD Vali 'O .1 PAINT NEW DOORS. NOTE: ALL DOORS W LEVER TYPE HANDLES. a C' Q� a E Z W �.., � WINDOW SCHEDULE Z � x v > � z NO. �o� o`,Z,1`O SHE C0w .2OZ MATERIAL REMARKS 10 Ui U '"J i--i LO W .�K. by: J.V. E EXIST. EXIST. - AL /GLASS. EXISTING STOREFRONT. DOOR SCHEDULE 11- 18 -09. ALL SPACES. • • • • 11' -6" EXISTING CEILING HEIGHT. RESTROOM. • • • • • 8' -0" 1 EXISTING CEILING HEIGHT. FIRESTOPPING - NON -RATED PARTITION DETAIL 1 (D- DOOR SCHEDULE 7 5 2. 3/4" STUCCO FINISH Civil * 41592 MARK LOCATION O DOOR OPENING SIZE MATERIAL 9 5 8 10 FINISH Q REMARKS W. H. T. DOOR FRAME DOOR FRAME E1 FRONT ENTRANCE. 3 4 7 6' -0" 7' -0" 1 3/4" AL /GLASS AL. GLASS. PAINT EXISTING DOOR. E2 BATHROOM. 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH WOOD PAINT EXIST CMU W/ EXIST D/W FURR PAINT EXISTING DOOR. E3 VESTBULE. W 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH WOOD PAINT cm PAINT EXISTING DOOR. 1 WAX ROOMS 1, 2 & 3. 3' -0" 6' -8" 1 3/4" WOOD S.C. FLUSH WOOD PAINT 'O .1 PAINT NEW DOORS. NOTE: ALL DOORS W LEVER TYPE HANDLES. a C' Q� a E Z W �.., � WINDOW SCHEDULE Z � x v > � z NO. �o� o`,Z,1`O SHE C0w .2OZ MATERIAL REMARKS 10 Ui U '"J i--i LO W .�K. by: J.V. E EXIST. EXIST. - AL /GLASS. EXISTING STOREFRONT. DOOR SCHEDULE 11- 18 -09. FIRESTOPPING - NON -RATED PARTITION DETAIL 1 (D- 6. 7 5 2. 3/4" STUCCO FINISH Civil * 41592 RATED GYP. BD. EXIST CONCRETE EXTERIOR WALL O NEW D/W PARTITION O 7 BATT INSULATION R -11. 9 5 8 10 6 (2)LAYERS 6 6 -1 Engineers (2)LAYERS 6 O 8 6 EXIST TOILET PARTITION 3 O XIST D/W (1 HR) IRE RATED U.L.425 O 1 11. 2 "X6" WOOD CAP 3 4 7 1 3 4 7 Fax: 305-480-7886 E-mail EDCAM014811000MCASi'.NET 00 N 00 �-+ Q # EXIST CMU W/ EXIST D/W FURR O NEW CMU W/ NEW D/W FURR 6 O , l e g e n d 1. 8" CONCRETE WALL 6. 1- 5/8" TYPE "X" FIRE 2. 3/4" STUCCO FINISH Civil * 41592 RATED GYP. BD. 3. 1" x 2" TRESSURE TREATED FURRING 7• 1/2" GYPSUM BOARD. STRIPS @ 16" c/c 8. BATT INSULATION R -11. 4. FOIL INSULATION R -4.1 Engineers 5. 1 -5/8" x 3 -5/8" (25 ga.) g 1 /2" GYPSUM GREEBOARD. METAL STUDS @ 16 c/c 10. CERAMIC TILE. 11. 2 "X6" WOOD CAP EXIST. ROOF. l• , mm,ni CEILING EL, +11' -6" PARTITION ASSEMBLY LEGEND I Q) INTERIOR PARTITION 3/4" 1 _ EmiIiU- Castro Engineer Civil * 41592 Of E.C. & ASSOCIATES Consulting to to �., . Engineers EB 06576 14811 S.W. 9th Lane Miami, Florida 33194 Phone: 305-480-7884 Fax: 305-480-7886 E-mail EDCAM014811000MCASi'.NET 00 N 00 �-+ Q # N # W F cm z F cm �z� W z� w N Z w� W Q�w 'O .1 � � BO �w O a C' Q� a E Z W �.., � �.. Z � x v > � z �x �o� o`,Z,1`O C0w .2OZ o� ti0 0_ ►� 10 Ui U '"J i--i LO U) Design by: J.V. No. Revision /Issue Plot Date: 1Q DOOR SCHEDULE 11- 18 -09. Engineer: Of J • to to �., . EMILIO CASTRO SEAL In this Page: SITE & FLOOR PLAN. PROPERTY ADDRESS. LEGAL DESRIPTION. SCOPE OF WORK. ZONING INFO. Scale: Details scale: AS NOTED I AS NOTED Job #: AC 09 -17 -2009 1 Sheet No. Date: A -1 Check by: 09 -17 -2009. E.C.