09-914-00104
0
EXISTING (1) HR FIRE RATED PARTITION. /;
WAX B -1 WAX Te
n FF_ gROOM #5. ROOM #4. PB1 b
8' - 6' -1„ 2' -O„ 13' -5" 8-0
° E
TOP OF SOFFIT RECEPTION in TOP OF o CIS
\ ELEV. 8" A.F.F. I DESK. COUNTER WAITING AREA. �°,
LO
EXISTING (AG
` 3 LOW PARTITION. 2 LOW PAR ITION. 2 k 9z 4i
)
RESTR1 ` ht: 34 ht: 34
�s56 .... - - - - - --
D G T P 2 787.34 SQ FT. /
A1
EF .� ..................°.................. ..........................>oN o
CORRIDOR. 'Z 1 EXIST. ' ef
TRAVEL Al E1 ENTRY. v
DISTANCE E2 o� O :.. rITI .... ....... / / 54 -0 �. F -1 -1 " / / ELECT. Q' B -1 F -1 4 -8
PANEL. 0 00 1 B -1
if
VESTIBULE' ❑
- WAX ° 2 WAX WAX
I E3 • ROOM #3. ROOM #2. X. ROOM #1. DISPLAY.
EXIST 0 F -1 2 „„ 2 0
L J B -1 32 X75 / / �� N
6' -5" 4' -0" 8' -0" 8' -0" 8' -0" 5' -3 °/
0
' °" "rT "' .STUDS 24" C/C
PSUM WALLBOARD
wQ
CI_
�o
Iw
oa
Z w
M�TALSTUDS
4 ' WOOD @ 16" C/C
'SUM WALLBOARD
EXISTING SUSP.
ACOUSTICAL CLG.
FTOP OF SOFFIT
ELEV. 8" A.F.F.
WAX WAX
ROOM #5. ROOM #4.
LOW PARTITION. . LOW PARTITION.
ht:34" 00 ht:34"
:.....:...:............ ° ................. .. o
. .
. . .. ...... . N .
...
.... . .
PROVIDE DOUBLE
STUDS AT OPENING (TYP)
0
RECEPTION
00 DESK.
T"
t0
EXIST.
FIRE EXT.
4
PROPOSED FLOOR PLAN
SCOPE OF WORK.
EXISTING RETAIL SPACE TO BE USED AS WAX SALON.
MAXIMUM OCCUPANCY LOAD: 787.34 SQ. FT. /100 = 8.
ALTERATION - LEVEL 2 (AS PER F.B.C. EXISTING BLDG).
EXISTING (1) HR FIRE RATED PARTITION.
MAXIMUM OF 1/2" DIFFERENCE IN LEVEL BETWEEN
OPPOSITE SIDES OF ALL EXIT DOORS IN ACCORDANCE
WITH NFPA 101 5- 2.1.3.3
PROJECT SUMARY.
OCCUPANCY
AREA.
OCCUPANCY
MEANS OF
CLASSIFICATION.
L •
LOAD.
EGRESS.
BUSSINESS-
787.34 SQ FT.
1/100 SQ FT. NET
REQ'D 1 DOORS
GROUP "B ".
B -1
787.34/100 =8
PROV 1 DOORS
WAX SALON.
EMERGENCY LIGHT FIXTURE(TYP.)
TWOOD
T.
PARKING REQUIREMENTS.
COMMERCIAL SPACES.
RETAIL & OFFICE =1 SPACE FOR EVERY 300 SQ FT (787.34) = 3 SPACES.
REGULAR PARKING PROVIDES = 3 SPACES.
GENERAL NOTES:
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND ANGLES
AND ALL OTHER EXISTING CONDITIONS PRIOR TO COMMENCING ANY WORK.
CONTRACTOR TO ALSO VERIFY AND APPROVE ALL INFORMATION ON DRAWINGS.
ACCEPTANCE OF THESE PLANS CONSTITUTES APPROVAL. PLEASE NOTIFY ENGINEER
BY CERTIFIED MAIL OF ANY CONFLICTS OR DISCREPANCIES, IF ANY.
2. THE CONTRACTOR SHALL OBTAIN FROM ALL SUBCONTRACTORS THE
FINAL APPROVED SITE AND LOCATION OF ALL OPENINGS TO BE
PROVIDED FOR RESPECTIVE TRADES. HE SHALL BE RESPONSIBLE FOR
LOCATION AND DETAILS.
3. OWNER AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRITING, BY
CERTIFIED MAIL UPON COMMENCEMENT OF PROJECT.
4. THE OWNER SHALL BE SOLELY RESPONSIBLE FOR INVESTIGATION IN
REFERENCE TO WHETHER STRUCTURE CAN BE BUILT ON SITE.
PAYMENT OF THESE DRAWINGS CONSTITUTES ACCEPTANCE & AGREEMENT
WITH THE FOLLOWING STATEMENT: NO PARTY SHALL INITIATE DELAY CLAIMS
AGAINST EMILIO CASTRO & /OR E.C. ASSOCIATES, INC. LIABILITIES SHALL BE
LIMITED TO FEES PAID TO THE DESIGN PROFESSIONAL.
FIRE PROTECTION NOTES
PROVIDE ( ONE ) CERTIFIED 2A -108C FIRE EXTINGUISHER FOR
EACH GROSS BUILDING AREA OF 3000 SQ.FT. AND WITH A
MAXIMUM TRAVEL DISTANCE TO REACH OF 75 FEET
MOUNTING HEIGHT TO TOP OF EXTINGUISHER SHALL
NOT EXCEED 48" AFF
ALL INTERIOR FINISH MATERIALS TO BE INSTALLED SHALL HAVE
A MINIMUM CLASS "C" FLAME SPREAD RATING
EXISTING BUILDING HAS AN APPROVED AUTOMATIC FIRE
SPRINKLER SYSTEM IN ACCORDANCE WITH FFPC & NFPA.
DOORS NOTE:
EVERY CLOSET DOOR LATCH SHALL BE SUCH
THAT CHILDREN CAN OPEN THE DOOR FROM
INSIDE CLOSET
FLOOR
LEGEND
F -1
FLOOR:
WALLS
NEW LAMINATE FLOOR OVER
L •
EXISTING CERAMIC TILE.
MARK
(AS SELECTED BY TENANT)
EF
FLOOR:
LIGHTING FIXTURE SCHEDULE
EXISTING FINISH TO REMAIN
B -1
BASE:
FINISH
BASE
EMERGENCY LIGHT FIXTURE(TYP.)
TWOOD
T.
( OSMSELECTEDOBYFTEONOANT)
NO ELECTRICAL, MECHANICAL AND
PLUMBING WORK UNDER THIS PERMIT.
LEGEND &
SYMBOLS
®
INDICATES EXISTING 8" C.B.S. WALL
WALLS
INDICATES EXISTING FIRE /SMOKE BARRIER PARTITION
L •
INDICATES EXISTING PARTITION
MARK
INDICATES NEW 3 5/8 ", 25 GA. MTL. STUDS FRAMING
O
® 16" C/C WITH 1/2" DRYWALL FINISH EACH SIDE.
LIGHTING FIXTURE SCHEDULE
SYMBOL
MATERIAL
DESCRIPTION
FINISH
Q REMARKS
EMERGENCY LIGHT FIXTURE(TYP.)
H.
T.
W /BATTERY BACK -UP
FRAME
DOOR
CONNECT AHEAD OF SW.
E1
FRONT ENTRANCE.
EXIT LIGHT FIXTURE(TYP.)
6' -0"
7' -0"
W /BATTERY BACK -UP
AL /GLASS
AL.
CONNECT AHEAD OF SW.
FINISH SCHEDULE
ROOM NAME
FLOOR
BASE
WALLS
CEILING
L •
REMARKS
MARK
LOCATION
O
DOOR
OPENING
SIZE
MATERIAL
9
5
8
10
FINISH
Q REMARKS
W.
H.
T.
DOOR
FRAME
DOOR
FRAME
E1
FRONT ENTRANCE.
3
4
7
6' -0"
7' -0"
1 3/4"
AL /GLASS
AL.
GLASS.
PAINT
EXISTING DOOR.
E2
3
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
%;
PAINT
EXIST CMU W/
EXIST D/W FURR
3
EXISTING DOOR.
E3
VESTBULE.
W
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
WOOD
PAINT
cm
PAINT
EXISTING DOOR.
1
WAX ROOMS 1, 2 & 3.
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
WOOD
Vali
'O
.1
PAINT
NEW DOORS.
NOTE: ALL DOORS W LEVER TYPE HANDLES.
a
C'
Q�
a
E
Z
W �..,
�
WINDOW SCHEDULE
Z
� x
v > �
z
NO.
�o�
o`,Z,1`O
SHE
C0w
.2OZ
MATERIAL
REMARKS
10 Ui
U '"J i--i
LO
W
.�K.
by: J.V.
E
EXIST.
EXIST.
-
AL /GLASS.
EXISTING STOREFRONT.
DOOR SCHEDULE
11- 18 -09.
ALL SPACES.
•
•
•
•
11' -6"
EXISTING CEILING HEIGHT.
RESTROOM.
•
•
•
•
•
8' -0" 1
EXISTING CEILING HEIGHT.
FIRESTOPPING - NON -RATED PARTITION DETAIL
1
(D-
DOOR SCHEDULE
7
5
2. 3/4" STUCCO FINISH
Civil * 41592
MARK
LOCATION
O
DOOR
OPENING
SIZE
MATERIAL
9
5
8
10
FINISH
Q REMARKS
W.
H.
T.
DOOR
FRAME
DOOR
FRAME
E1
FRONT ENTRANCE.
3
4
7
6' -0"
7' -0"
1 3/4"
AL /GLASS
AL.
GLASS.
PAINT
EXISTING DOOR.
E2
BATHROOM.
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
WOOD
PAINT
EXIST CMU W/
EXIST D/W FURR
PAINT
EXISTING DOOR.
E3
VESTBULE.
W
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
WOOD
PAINT
cm
PAINT
EXISTING DOOR.
1
WAX ROOMS 1, 2 & 3.
3' -0"
6' -8"
1 3/4"
WOOD S.C. FLUSH
WOOD
PAINT
'O
.1
PAINT
NEW DOORS.
NOTE: ALL DOORS W LEVER TYPE HANDLES.
a
C'
Q�
a
E
Z
W �..,
�
WINDOW SCHEDULE
Z
� x
v > �
z
NO.
�o�
o`,Z,1`O
SHE
C0w
.2OZ
MATERIAL
REMARKS
10 Ui
U '"J i--i
LO
W
.�K.
by: J.V.
E
EXIST.
EXIST.
-
AL /GLASS.
EXISTING STOREFRONT.
DOOR SCHEDULE
11- 18 -09.
FIRESTOPPING - NON -RATED PARTITION DETAIL
1
(D-
6.
7
5
2. 3/4" STUCCO FINISH
Civil * 41592
RATED GYP. BD.
EXIST CONCRETE
EXTERIOR WALL
O
NEW
D/W PARTITION
O
7
BATT INSULATION R -11.
9
5
8
10
6
(2)LAYERS
6
6 -1
Engineers
(2)LAYERS
6
O
8
6
EXIST TOILET
PARTITION
3
O
XIST D/W (1 HR)
IRE RATED U.L.425
O
1
11.
2 "X6" WOOD CAP
3
4
7
1
3
4
7
Fax: 305-480-7886
E-mail EDCAM014811000MCASi'.NET
00
N
00
�-+
Q
#
EXIST CMU W/
EXIST D/W FURR
O
NEW CMU W/
NEW D/W FURR
6
O
,
l e g e n d
1. 8" CONCRETE WALL
6.
1- 5/8" TYPE "X" FIRE
2. 3/4" STUCCO FINISH
Civil * 41592
RATED GYP. BD.
3. 1" x 2" TRESSURE TREATED
FURRING 7•
1/2" GYPSUM BOARD.
STRIPS @ 16" c/c
8.
BATT INSULATION R -11.
4. FOIL INSULATION R -4.1
Engineers
5. 1 -5/8" x 3 -5/8" (25 ga.)
g
1 /2" GYPSUM GREEBOARD.
METAL STUDS @ 16 c/c
10.
CERAMIC TILE.
11.
2 "X6" WOOD CAP
EXIST. ROOF.
l• , mm,ni
CEILING
EL, +11' -6"
PARTITION ASSEMBLY LEGEND I Q) INTERIOR PARTITION 3/4"
1 _
EmiIiU- Castro
Engineer
Civil * 41592
Of
E.C.
& ASSOCIATES
Consulting
to to
�., .
Engineers
EB 06576
14811 S.W. 9th Lane
Miami, Florida 33194
Phone: 305-480-7884
Fax: 305-480-7886
E-mail EDCAM014811000MCASi'.NET
00
N
00
�-+
Q
#
N
#
W
F cm
z
F
cm
�z�
W
z�
w
N
Z
w�
W
Q�w
'O
.1
� �
BO
�w
O
a
C'
Q�
a
E
Z
W �..,
�
�..
Z
� x
v > �
z
�x
�o�
o`,Z,1`O
C0w
.2OZ
o�
ti0
0_ ►�
10 Ui
U '"J i--i
LO
U)
Design
by: J.V.
No.
Revision /Issue
Plot
Date:
1Q
DOOR SCHEDULE
11- 18 -09.
Engineer:
Of
J
•
to to
�., .
EMILIO CASTRO
SEAL
In this Page:
SITE & FLOOR PLAN.
PROPERTY ADDRESS.
LEGAL DESRIPTION.
SCOPE OF WORK.
ZONING INFO.
Scale: Details scale:
AS NOTED I AS NOTED
Job #: AC 09 -17 -2009 1 Sheet No.
Date: A -1
Check by: 09 -17 -2009.
E.C.