13-1306-007EXISTING ROOF OVERHANG NEW 2X10 WOOD RAFTERS 0 24" O.0 (TYP.) NEW 3X10" P.T. WOOD LEDGER,­." EDGER _____ BEAM FASTENED TO EXISTING CONCRETE TIE BEAM WITH 5/8 "0 ANCHOR BOLTS HILTI KWIK 8OLT -3 BY HILTI, SPACED AT 12' -' - "- ON CENTERS (TYP.) ------ - - - - -- - - - -- I I I ------------- ► - - - -- NEW 2X10 WOOD RAFTERS 0 24" O.0 (TYP.) NEW 3X10" P.T. WOOD LEDGER BEAM FASTENED TO EXISTING CONCRETE TIE BEAM WITH 5/$'0 ANCHOR BOLTS HILTI KWIK BOLT -3 BY HILTI, SPACED AT 12" ON CENTERS (TYP.) EXISTING CONCRETE TIE BEAM EXISTING CMU WALL i `--2X8 WD BLOCKING AT MID SPAN (TYP.) I 1 I I I I I .---------- - -j- -- - - - - -- - I - - I I . . 1/2' 0 N ROOF PLAN SCALE 1/4 " =1' -0" C -1 (TYP-) I I. I I I I I • C -1 I, I I I I: i. I' I -C -1 (TYP.) II I -C -1 (TYP') 1 S -4 (3)2X12" WOOD BEAM WITH 1/2" 0 A307 GALVANIZED THRU BOLTS WITH NUT AND WASHERS 0 24" O.0 MAX, EQ DISTRIBUTED, STAGGERED. EXISTING ROOF STRUCTURE TO REMAIN UNDISTURBED. (TYP) C -1 (TYP.) DETAIL, -1 EXIST. POOL EXISTING ROOF OVERHANG LUS28 BY SIMPSON (TYP.) W/ (6)10d NAILS TO LEDGER BEAM AND (4)10d NAILS TO RAFTER (TYP.) FLORIDA APPROVAL FL10655. ALLOW. UPLIFT CAPACITY =1,165 LBS ALLOW. GRAVITY LOAD CAPACITY =1,480 LBS CALCULATED UPLIFT LOAD =555 LBS CALCULATED GRAVITY LOAD =570 LBS - NVRT -20 BY NU -VUE (TYP.) W/ (7)16D NAILS TO WD. BEAM AND (7)16D NAILS NOTE: WITH 3000 PSI FINE MASONRY GROUT: SEE 'PLYWOOD SHEATHING NOTES" FOR BLOCKS IN CONNECTION AND AT LEAST ONE NAILING REQUIREMENTS. ALL ROOF WOOD BEAM (3)2X12" WITH " 3" SHEATHING NAILS SHALL BE HAND- DRIVEN. 1/2" 0 A307 GALVANIZED PLYWOOD PANEL (NORMALLY 4'X8') LAY IN NAILING AT INTERMEDIATE SUPPORTS A STAGGERED JOINT PATTERN CONT. OVER ( "FIELD NAILING ") - SEE "PLYWOOD 2 OR MORE SPANS ON NEW 1X6T &G WOOD SHEATHING NOTES" BOARDS. - CONFORMING WITH ASTM A193 - = GRADE B7. N = NOA No. 09- 0224.06,; EMBEDDED INTO SOLID 066b) M _;- BLOCK CELL. STRUCTURAL 3/4' 0 A307 SSU�T iO?; , GALVANIZED THRU BOLTS WITH NUT AND WASHERS. ?'''•= ; EY. 1/4w STEEL BENT PLATE LEAYF- GAPS 1/$' SECTION C -C Al .' • , NAILING AT BOUNDARY ' • EDGES- SEE 'PL ' • SHEATHING NOTES" , SUPPORT FRAMING FISHEATHING DETAIL (TYP.) /4 " =1' -Q" NEW 5/8" PLYWOOD SHEATHING ON 1 T&G 1 X6 WOOD BOARDS. SEE SHEATHING DETAIL AND NOTES NEW 2X10' RAFTERS `0 24" O.0 (TYP.) Nil- r -- 11Ln VAiv r,,, TTVVU LWULn FASTENED TO EXISTING CONCRETE TIE BEAM WITH 5/8" 0 ANCHOR BOLTS HILTI KWIK BOLT -3 BY HILTI, SPACED AT 12' ON CENTERS (TYP.) SECTION 13-13 TO RAFTER (TYP.) FLORIDA APPROVAL FL 599,6. ALLOW. UPLIFT CAPACITY =1,132 LBS CALCULATED UPLIFT LOAD =987 LBS NEW 5/8" PLYWOOD SHEATHING ON T&G 1X6 1 WOOD BOARDS. SEE SHEATHING DETAIL AND NEW WOOD BEAM CONSISTING OF NOTES A , (3)2X12' WITH 1/2" 0 A307 GALVANIZED THRU BOLTS WITH NUT AND WASHERS 0 24' O.0 STAGGERED. I � i I 1X2" P.T. WOOD 2X8 WD BLOCKING AT NEW 2X10" RAFTERS 2X12" WOOD FASCIA MID SPAN (TYP.) 0 24' O.0 (TYP.) - 3/4" 0 A307 GALV NIZED THRU BOLTS. I A , O.H. SEE ARCH. 1/4' STEEL BENT PLATE I E70XX S E C T ION 1 3/16" STEEL COLUMN. SEE COLUMN I 1 =1 -0 S -2 SCHEDULE I I NEW WOOD BEAM CONSISTING OF (3)2X12" WITH 1/2" 0 , c A307 GALVANIZED THRU BOLTS 4' STEEL WITH NUT AND WASHERS 0 1/4" 24' OX STAGGERED, PLATE I 1/4" STEEL F;r BENT PLATE I 3/4' 0 A307 GALVANIZED THRU BOLTS. Q CMU WALL PLYWOOD ROOF SOT}tlNG NOTES: 1. ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE AMERICAN PLYWOOD ASSOCIATION (APA) SPECIFICATIONS. 2, ALL ROOF PANEL SHEATHING SHALL BE 5/8 "(NOM.) TYPE COX EXP. APA RATED SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED BY USE OF BLOCKING BETWEEN FRAMING. UNLESS OTHERWISE NOTED CONNECT ROOF SHEATHING WITH LU ' RING -SH�K NAILS AT 4" 0/C AT SUPPORTED PANEL EDGES AND 6. O/C AT INTERMEDIATE SUPPORTS. 3. INSTALL ALL PLYWOOD SHEATHING WITH THE STRENGTH AXIS OF THE PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR MORE SPAN$. STAGGER PANEL END JOINTS. ALLOW 118" SPACING AT PANEL ENDS AND EDGE$ UNLESS OTHERWISE RECOMMENDED BY THE SHEATHING MANUFACTURER. ' 4. ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE USE OF STAPLES AND PNEUMATIC NAIL ' GUNS ARE PROHIBITED FROM USE. ' ROOF WOOD BOARDS: 1. ROOF WOOD BOARDS TO BE TONG AND GROOVE 1 "X6 "X8' -0 ", BOARD GRADE, LAID IN A STAGGERED JOINT PATTERN AND CONTINUOUS OVER 3 OR MORE SPANS. 2. BOARD ROOF SHEATHING SHALL HAVE A NET THICKNESS OF NOT LESS THAN 3/4 " (1" NOMINAL); AND SHALL BE NAILED SO THAT IT STAYS IN PLACE TO RECEIVE PLYWOOD SHEATHING NAILING THROUGH IT INTO FRAMING BELOW EPDXY ANCHOR HIT-HY150 WITH THREADED ROD HAS BY HILTI, CONFORMING WITH ASTM A193 GRADE B7. NOA No. 09- 0224.061 5" 1/4" STEEL BENT PLATE , C E70XX EMBEDDED INTO SOLID GROUTED TYP. BLOCK CELL 3/16' WOOD BEAM WOOD BEAM STEEL CONNECTION TO WALL CONNECTOR DETAIL DETAIL -1: WOOD BEAM CONNECTION TO WALL SCALE 10= V -0" NEW 5/8" PLYWOOD SHEATHING ON T &G 1X6 WOOD BOARDS. SEE SHEATHING DETAIL AND NOTES NEW ) X10' RAFTERS 0 24" O.0 TYP. 1 II 4" L 4" 3/4" 0 A307 GALVANIZED THRU BOLTS. E70XX TYR 3/t6" SECTI N A -A NVRT -20 BY NU -WE (TYP.) W/ (7)16d NAILS TO WD. BEAM AND (7)16d NAILS TO RAFTER (TYP.) FLORIDA APPROVAL FL 599.6. ALLOW. UPLIFT CAPACITY =1,132 LBS CALCULATED UPLIFT LOAD =905 LBS L-NEW WOOD BEAM CONSISTING OF (3)2X12" WITH 1/2" 0 A307 GALVANIZED THRU BOLTS WITH NUT AND WASHERS 0 24" O.0 STAGGERED. NOTES: 1.- IF BLOCK WALL IS HOLLOW AT PLACE OF CONNECTION, CAREFULLY REMOVE BLOCK FACE ABOVE CONNECTION LOCATION, AND FILL CELL SOLID WITH 3000 PSI MASONRY FINE GROUT. 2,- AFTER GROUT HAS REACHED FULL STRENGTH, INSTALL EPDXY ANCHORS SO THAT: _ONLY ONE ANCHOR IS INSTALLED PER BLOCK, - CENTER ANCHOR HORIZONTALLY IN BLOCK - SEPARATION OF ANCHOR FROM VERTICAL JOINT TO BE MORE THAN 4' EXISTING CMU WALL TO BE FILLED SOLID WITH 3000 PSI FINE MASONRY GROUT: BLOCKS IN CONNECTION AND AT LEAST ONE ABOVE AND ONE BELLOW - WOOD BEAM (3)2X12" WITH " 3" 1/2" 0 A307 GALVANIZED THRU BOLTS WITH NUT AND d, - WASHERS 0 24" O.0 STAGGERED. EPDXY ANCHOR HIT -HY150 WITH THREADED ROD HAS BY HILTI, - CONFORMING WITH ASTM A193 - = GRADE B7. N = NOA No. 09- 0224.06,; EMBEDDED INTO SOLID 066b) M _;- BLOCK CELL. STRUCTURAL 3/4' 0 A307 SSU�T iO?; , GALVANIZED THRU BOLTS WITH NUT AND WASHERS. ?'''•= ; EY. 1/4w STEEL BENT PLATE ; - T" "D SECTION C -C Al MW QM2j MMA PER &%U -10 BASIC WIND SPEED V= 175 MPH (FOR ULTIMATE ANALYSIS) WIND EXPOSURE = C BUILDING CATEGORY: II ENCLOSURE CLASSIFICATION = BLDG ENCLOSED r� Kd= 0.85 qh= -33.94 PSF (FOR ASD ANALYSIS) TELEPHONE (305) 285-67231 FAX (305) 285-6722 535 SW 8 ST. SUITE 100 MIAMI, FL. 33130 DESIGN I CONSTRUCTION ADMINISTRATION I BUILDING INSPECTIONS I CAD PRODUCTION CDNSULTANT/ W ESS APPRgWALS/Wf&0N1S DATE 1� BUILDING DEPARTMENT REVIEW 12 -30 -13 cn w W � U o Z w J u EL LLJ LL j n >..r C) W z �x oN OC Q SO a D � v 0 CL S✓FJIL: * N*= IZ- 13-41a ti STATE OF CAPU D12SGN INC. 8040 SW 37 TERRACE MIAMI FL 33155 C.A 26021 CARLOS A. DEL PINO PE 59888 (D PH. (305) 815 -1643 capledesign@gmaii.com SHEET T1TL� ROOF PLAN AND DETAILS Job No. Drowinq No. Dt m By: D . f b*•: %Sm2 Scxdc (VIBES - SEE DRAWING)