14-1016-004I— DOOR THRESTHOLDS
TILE, STONE,
WOOD, OR TILE, STONE,
CARPET WOOD, OR
CARPET
CONCRETE
TYPE 1:
NO THRESHOLD
TILE, STONE
OR WOOD
TYPE 2:
THRESHOLD
2PET
TYPE 3:
THRESHOLD
ALUMINUM
STOREFRONT
DOOR
NEOPRENE
WEATHERSTRIP
(TYP)
EXTERIOR
CONCRETE SLAB
AT J16- PER FT.
SLOPE --\
RPET
ALUMINUM
THREATSHOLD #172A
BY "PEMKO," IN
CONTINUOUS BED OF
ELASTOMERIC SEALANT
t ,'' .YA ��� •'. '. es'. s4. rb t.Se
TYPE 4:
THRESHOLD/ GROUND FLOOR
ALUMINUM
STOREFRONT
DOOR
NEOPRENE
WEATHERSTRIP
(nP)
EXTERIOR
CONCRETE SLAB
AT }s" PER FT.
SLOPE --� -
ALUMINUM
THREATSHOLD #172A
BY "PEMKO," IN
CONTINUOUS BED OF
ELASTOMERIC SEALANT
TYPE 5:
THRESHOLD/ SECOND FLOOR
ALUMINUM
DOOR
EXTERIOR
CONCRETE SLAB
AT }s" PER FT.
SLOPE —,, -xj_
ALUMINUM
THREATSHOLD #172A
BY "PEMKO," IN
CONTINUOUS BED OF
ELASTOMERIC SEALANT
TYPE 6:
THRESHOLD/ GROUND FLOOR
ALUMINUM
DOOR
EXTERIOR
CONCRETE SLAB
AT 7 - PER FT.
SLOPE - ,
ALUMINUM
THREATSHOLD #172A
BY "PEMKO," IN
CONTINUOUS BED OF
ELASTOMERIC SEALANT
TYPE 7:
THRESHOLD/ SECOND FLOOR
DOOR SCHEDULE
ABBREVIATIONS
AC—
AER8V1fN -PROTECTION — —
AL
— ALUMINUM — — — — — —
CLR-- CLEAR- - - - - --
fX—
EXISTING— - - - - --
FF
— FACT'01* FINISH — — — -
-GL—
GLASS- - - - - --
-L
— PLASTIC -LAMINATE- COLOR —
MTL— METAL - - - - - --
-P—
PAINT - - - - ---
-SC—
SOLID £-0RE — — — — —
STL—
STEEL - - - - - --
WD—
WOOD - - - - ---
–
AL
r-----------
SELF – CLOSER AND PANIC HARDWARE
DOOR SCHEDULE
m
z
SIZE
DOOR
FRAME
HARDWARE REQUIRMENTS
NOTES
=
3
i
=
Y
=E
WALLS
J
0
=
cn
FIRST AND
SECOND
FLOOR
1
3' -0"
6' -8"
1 -3/4"
A
AL
–
AL
4
SELF – CLOSER AND PANIC HARDWARE
STOREFRONT ALUM. FRAME /IMP. NOAH 1- 0412.04
2
S -0"
6' -8"
1 -3/4"
A
AL
–
AL
4
SELF – CLOSER AND PANIC HARDWARE
STOREFRONT ALUM. FRAME /IMP. NOAH 1- 0412.04
3
3' -0"
6' -8"
1 -3/4"
D
AL
A
AL
6
SELF – CLOSER AND PANIC HARDWARE
IMPACT RATED/ 45MIN DOOR
4
3' -0"
6' -8"
1 -3/4"
D
AL
A
AL
6
SELF – CLOSER AND PANIC HARDWARE
IMPACT RATED/
$5
2' -10"
6' -8"
1 -3/4"
D
AL
A
AL
1
INTERIOR HARDWARE
EXISTING DOOR TO REMAIN
•6
2' -10"
6' -8"
1 -3/4"
E
WD
A
WD
3
INTERIOR HARDWARE
EXISTING DOOR TO REMAIN
•7
2' -10"
6' -8"
1 -3/4"
E
WD
A
WD
3
INTERIOR HARDWARE
EXISTING DOOR TO REMAIN
8
(2)2' -0"
6' -8"
1 -3/4"
G,H
AL
B
AL
1
INTERIOR HARDWARE
–
9
(2)2' -0"
6' -8"
1 -3/4"
G,H
AL
B
AL
1
INTERIOR HARDWARE
–
10
3' -0"
6' -8"
1 -3/4"
A
AL
–
AL
5
SELF – CLOSER AND PANIC HARDWARE
STOREFRONT ALUM. FRAME /IMP. NOA:11- 0412.04
11
3' -0"
6' -8"
1 -3/4"
A
AL
–
AL
5
SELF – CLOSER AND PANIC HARDWARE
STOREFRONT ALUM. FRAME /IMP. NOA:11- 0412.04
12
3' -0"
6' -8"
1 -3/4"
D
AL
A
AL
7
EXTERIOR HARDWARE
IMPACT RATED /
13
3' -0"
6' -8"
1 -3/4"
C
AL
–
AL
5
SELF – CLOSER AND PANIC HARDWARE
STOREFRONT ALUM. FRAME /IMP. NOA.11- 0412.04
14
2' -10"
6' -8"
1 -3/4"
F
WD
A
WD
3
INTERIOR HARDWARE
–
15
2' -10"
6' -8"
1 -3/4"
E
WD
A
WD
3
INTERIOR HARDWARE
–
16
2' -10"
6' -8"
1 -3/4"
E
WD
A
WD
3
INTERIOR HARDWARE
–
17
4' -0"
6' -8"
1 -3/4"
1
AL
B
AL
2
INTERIOR HARDWARE
AIR TIGHT DOOR
18
2' -10"
6' -8"
1 -3/4"
F
WD
A
WD
3
INTERIOR HARDWARE
-
19
j 2' -10"
6' -8"
1 -3/4"
F
WD
A
WD
3
INTERIOR HARDWARE
-
20
1 2' -10"
6' -8"
1 -3/4"
E
WD
B
WD
3
INTERIOR HARDWARE
-
" DOOR IS AN EXISTING DOOR TO REMAIN
GENERAL DOOR NOTES:
1. CONTRACTOR SHALL COORDINATE AND VERIFY
WITH DOOR MANUFACTURER'S SHOP DRAWINGS
FOR REQUIRED MASONRY OPENING FOR PROPER
INSTALLATION BEFORE CONCRETE BLOCK WORK
IS STARTED OR TIE COLUMNS ARE POURED.
G.C. TO VERIFY WITH DOOR INSTALLER. DOOR
SIZES ON DRAWINGS ARE NOMINAL DIMENSIONS.
2. INSTALLATION OF DOOR ASSEMBLIES SHALL BE
IN STRICT ACCORDANCE WITH THE DESIGNATED
AND APPROVED METHOD INDICATED IN THE SHOP
DRAWINGS AND THE N.O.A. SUBMITTALS AS
APPROVED PRODUCT CONTROL PER THE F.B.C.
3. ALL FIXED GLASS PANELS SHALL BE 3/16" OR
THICKER AS REQ. TO MEET WIND LOADS AND
IMPACT REQUIREMENTS. ALL GLASS USED INSIDE
OF DWELLING TO BE TEMPERED, TO COMPLY WITH
THE F.B.C.
4. ALL EXTERIOR DOORS TO BE IMPACT RESISTANT.
SEE SHOP DRAWINGS FOR EXACT SPECIFICATIONS.
ALL EXISTING OPENINGS (IF APPLICABLE) TO BE FIELD
VERIFIED PRIOR TO ORDERING DOOR ASSEMBLY.
FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED
WITH A DOOR SCOPE OR VISION PANEL.
5. ALL LOCKS ON EXTERIOR DOORS SHALL BE
CAPABLE OF RESISTING A FORCE OF 300 LB.
APPLIED IN ANY MOVABLE DIRECTION IN
ACCORDANCE WITH RESISTANCE STANDARDS
SET FORTH IN F.B.C.
6. EVERY CLOSET DOOR LATCH SHALL BE SUCH
THAT CHILDREN CAN OPEN THE DOOR FROM
INSIDE THE CLOSET.
7. EVERY BATHROOM DOOR LOCK SHALL BE
DESIGNED TO PERMIT THE OPENING OF THE
LOCKED DOOR FROM THE OUTSIDE IN AN
EMERGENCY.
Ilk
MIAMI
COLTRAIN AND JONES ARCHITECTS, PA
AA 26000922
TELEPHONE (305) 285 -67231 FAX (305) 285-6722
535 SW 8 ST. SUITE 100 MIAMI, FL. 33130
DESIGN I CONSTRUCTION ADMINISTRATION
BUILDING INSPECTIONS I CAD PRODUCTION
CONSULTANT/ NOTES
APPROVALS /REVISIONS DATE
SEAL:
FIRE COMMENTS
0
FINISH SCHEDULE
z
0
WALLS
J
_
_
w
ROOM NAME
Z
NOTES
O
o
W
m
°z
cn
='
z
U-
X
En
3r
U
-
EXIST. CLASSROOM #1
CONC.
TILE
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
GENERAL FINISH NOTES:
TILE
/CARPET
–
PAINT
PAINT
PAINT
PAINT PAINT
0
M
-�
U
F-
>
aC
�
�
1. FINISHES ARE TO BE SELECTED BY
–
EXIST. BATHROOM #1
CONC.
TILE
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
OWNER. G.C. TO COORDINATE FINISHES
_j
LL:.
u)
TILE
I%-
Lo
PAINT
PAINT
PAINT
PAINT PAINT
W/ OWNER SELECTIONS.
–
EXIST. A/C CLOSET 11
CONC.
–
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
2 PAINT IS TO BE TWO COATS OF
Ca
CARPET
L
00
PAINT
PAINT
PAINT
PAINT PAINT
0
Q
cl)
BENJAMIN MOORE REGAL INTERIOR PAINT.
–
EXIST. CLASSROOM 12
CONC.
TILE
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
PAINT COLOR AND FINISH TO BE
TILE
/CARPET
–
PAINT
PAINT
PAINT
PAINT PAINT
SELECTED BY OWNER.
–
EXIST. BATHROOM #2
CONC.
TILE
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
–
3. FLOORING AND BASE TO BE SELECTED
.TILE
–
PAINT
PAINT
PAINT
PAINT PAINT
BY OWNER. G.C. TO PROVIDE AND
–
EXIST. A/C CLOSET #2
CONC.
_
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
–
INSTALL.
CARPET
PAINT
PAINT
PAINT
PAINT PAINT
–
MEDIA ROOM
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC ROOM
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
CLASS RM STORAGE
CONC.
–
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
TILE
–
PAINT
PAINT
PAINT
PAINT PAINT
–
CORRIDOR
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
CARPET
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO #1
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO 12
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO 13
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO #4
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO 15
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
MUSIC STUDIO #6
CONC.
WOOD
GYP. BD
GYP. BD.
GYP. BD.
GYP. BD. GYP. BD.
_
WOOD
PAINT
PAINT
PAINT
PAINT
PAINT PAINT
–
A/C CLOSET
CONC.
CONC.
CONC.
CONC.
CONC.
CONC. CONC.
_
SEALANT
SEALANT
PAINT
PAINT
PAINT
PAINT PAINT
Ilk
MIAMI
COLTRAIN AND JONES ARCHITECTS, PA
AA 26000922
TELEPHONE (305) 285 -67231 FAX (305) 285-6722
535 SW 8 ST. SUITE 100 MIAMI, FL. 33130
DESIGN I CONSTRUCTION ADMINISTRATION
BUILDING INSPECTIONS I CAD PRODUCTION
CONSULTANT/ NOTES
APPROVALS /REVISIONS DATE
SEAL:
FIRE COMMENTS
° OF.
.
;o
0
z
0
J
m
C�
Z
co
X
w
0
F_
oz
0
0
M
-�
U
F-
>
aC
�
�
O
W
W
0
cu
QQ
>
_j
LL:.
u)
I%-
Lo
z
�
Q
Z
O
c:
P
o
r
Ca
L
00
o
0
Q
cl)
° OF.
.
;o