Loading...
13-1230-004* ** OVERTURNING AND SLIDING * ** WIND PER ASCE 7 -10 psi: =1b /in squ. PLF: =1b /ft psf: =Ib /ft squ. * ** VARIABLES * ** BUILDING WIDTH BW: =23.33 ft. OVERHANG LENGTH OL: =2.1n. ROOF DEAD LOAD RD: =8 PSF. FLOOR DEAD LOAD FD: =8 PSF. WALL DEAD LOAD WD: =5 PSF WALL HEIGTH WH: =10.0 ft. INCLUDES TRUSS HEAL AND FLOOR IMPORTANCE FACTOR 1:=1.0 NO. OF MODULES NM: =2 MAX BUILDING LENGTH BL: =36' -0" PARA. TO I -BEAM EXPOSURE CATAGORY = C WIND SPEED IN MPH V.=175 VOLOCITY PRESSURE Exp: KZ: =0.85 TOPOGRAPHIC FACTOR. Kzt = 1.0 * ** COEFFICIENTS * ** INTERNAL GCpi: =0.18 WINDWARD WALL WWCp: =0.53 WINDWARD ROOF WRCp: =0.69 LEEWARD ROOF LRCp: =0.48 LEEWARD WALL LWCp: =0.43 OVERHANG OCp: =0.8 WIND DIRECTION FACTOR: Kd: = 0.85 VELOCITY PRESSURE EXP.: Kz: = 0.85 TOPOGRAPHIC FACTOR: Kzt = 1.0 MAX. ROOF PITCH ANGLE AT SIDEWALL (DEG) RA = 5 DISTANCE FROM BUILDING CENTERLINE TO OVERTURNING POINT A: = 9.Oft. DISTANCE FROM TURNING POINT TO TIE DOWN STRAPPING 8:=18.0 ft. TIE DOWN STRAP WORKING CAPACITY: =FTD =3150 lb. (4,725 lb. ACTUAL DIVIDED BY 1.5 SAFETY FACTOR = 3,150 lb.) ANGLE BETWEEN TIE DOWN STRAP AND GROUND TA: =45 DEGREES NO. OF VERTICAL STRAPS AT MATELINE VS: =O VERTICAL TIE DOWN STRAPPING WORKING VERTICAL CAPACITY VTD: =3150 lb * ** OVERTURNING * ** WIND PRESSURE 0:= 0.00256 Kd.Kz.Kzt.l (IV)squ.PSF WINDWARD WALL WW. =WWCp WINDWARD ROOF WR: =WRCp - GCpi LEEWARD ROOF LR: =LRCp - GCpi LEEWARD WALL LW: =LWCp WINDWARD OVERHANG WOH: =WRCp - OCp LEEWARD OVERHANG LOH: =LRCp - OCp RH = 0.5.BW.ton(RA.deg) HLw: = (WW- LW).q.WH HLr: = (WR- LR).q.RH HLrI: = if[(HLr < O.pif),O.pIf,HLr] 0Th:= HLw.(WH.0.5)+ HLrl.(WH +RH.0.5) OTv: =- WR.q(BW.0.5). [A +(BW.0.25)] +- LR1-2 q(BW.0.5). [A- (BW.0.25)] OToh:= BW+ A + O_L OL WOH + W A + J�qOL- LOH [2 OTd: = (RD + FD) BW A + WD WH 2 A [VTD VS1 (NM - 1) A] OTvs. ---------------- BL 0Th + OTv +OToh - (OTd.0.6) - OTvs VL:= ------------------ - - - - -- VL= 386.66plf B V11 := if [(VL < 1.Oplf),1.Oplf,VL] VLI= 386.66plf * ** SLIDING * ** DOWNWARD REACTION: TAKING MOMENTS AT WINDWARD I -BEAM [0Th + OTD - OToh +[LR.q.(BW.0.5), [A +(BW.0.25)]] + [WR.q(BW.0.5). [A- (BW.0.25)]]] -------------------------------------------------------- B DR1: = if [(DR < Oplf),Oplf, DR ] DR1: = Oplf DR2: = If [(VL < Oplf), VL , Oplf)] DR2: =Oplf DR3: = DR1 + DR2 DR3: = Oplf DR4: = if[( DR3 < Oplf),Oplf , DR3] DR4: =Oplf DR5: = if[( NM < 2),Oplf , DR4] DR5: = Oplf Fu:= lf[(0.2.DR5 < 25p1f),0.2.DR5.,25p1f] FU = Oplf HL: =HLw + HLrI -Fu HL: = 399.51p1f HL1:= if[( HL < 1.0 PLF) ,1.0 PLF, HL)] HL1:= 399.51p1f * ** SUMMARY * ** STRAP VERTICAL CAPACITY VC: =FTD sin(TA DEG) VC= 2227.39 lb STRAP HORIZONTAL CAPACITY HC: =FTD cos(TA DEG) HC= 2227.39 lb Vc SSv: _ - - -- SSv = 4.76 ft ul, HC SSh: = - - -- SSh = 4.58 ft HL1 SS: = if [(SSv < SSh),SSv,SSh] * ** MAXIMUM TIE DOWN SPACING * ** SS =4.58 ft. FOUNDATION NOTES: 1. TIE -DOWN STRAPS TO BE 1 -1/4" X .035 GALVANIZED STEEL FEDERAL SPECIFICATION QQS -781 -H TYPE -1 FINISH-13 GRADE -1. TIE -DOWN STRAPS AND CONNECTING HARDWARE TO HAVE 4,725# MINIMUM ULTIMATE CAPACITY. LISTED ANCHORS TO HAVE 3,150# MINIMUM WORKING LOAD CAPACITY. 2. SEE ABOVE FOUNDATION LAYOUT FOR TIE -DOWN STRAP SPACING. 3. ALL PIERS SHALL BE 8" X 8" X 16" MASONRY BLOCKS ON 4" X 16" X 16" CONCRETE PADS, EXCEPT AS OTHERWISE NOTED ON FOUNDATION PLAN. 4. MINIMUM SOIL BEARING CAPACITY IS 2000 PSF. TO BE VERIFIED BY BUILDING'S OWNER w w N I i� 04 00 I 00 _I 4" -8 "x16" CAP BLOCK 2x8 P.T. SYP #2 CAP. K8 "x16" CMU'S co 4 "x8 "x16" PADS 32" STAGGERED AS SHOWN SECTION B -B 361-011 24" MIN. 24" MIN. 32" MAX. 32" MAX. TYP. GROUND ^- 16° ANCHOR SECTION C -C TYP. OUTRIGGER TYP. OUTRIGGER TYP. HURRICANE TYP. HURRICANE STRAP STRAP TYP. GROUND ANCHOR 7'-2" TYP. SPACING MAY VARY 8' -0" MAX. F. T. F. T. F.T. F. T. F. T. F. T. F. T. F. T. I i- -------- - -i - -� _ I L � L j L L, AL .,A L f I I F. T. IIaaHIR ���Wpllll i LI � rip M9004 5�� L� 1 I I I F. T. F. T. F.T. F.T. A, 061 LNG NJ r _ 1_ •I I F.T. F.T. NOTE: STRAP SPACING MAY VARY DUE TO SITE CONDITIONS NOTE: STRAP SPACING 4' -6" MAX. 0. C. FRAME TIES ONLY, NO OVER ROOF STRAPS REQUIRED. SEE DETAIL F -FD1 FIRST STRAP FROM END WALLS NOT TO EXCEED 2' -0" 5. IT WILL BE THE BUILDING OWNER'S RESPONSIBILITY TO INSURE THAT ALL GRASS, LOOSE DEBRIS, ETC. ARE REMOVED FROM UNDER THE BUILDING,(FOOTING) AND THAT THE GROUND IS LEVELED TO WITHIN 6" AND FIRMLY COMPACTED. 6. WOOD SHIMS MAY BE INSTALLED WHEN NECESSARY,BETWEEN THE I -BEAM AND THE TOP OF THE PIER. SHIMS SHALL BE FREE OF KNOTS, CHECKS, SPLITS, AND SIMILAR IMPERFECTIONS. SHIMS SHALL BE OF P.T. LUMBER AND BEARING AT ALL CONTACT POINTS SHALL NOT BE LESS THAN 2/3 OF THE BEARING PRIOR TO ADDING THE SHIMS. 7. NOTE ALL MASONRY PIERS MAY BE INSTALLED IN A DRY STACK. NE NOTE - OVERALL WIDTH DIMENSION IS NOMINAL AND IS BASED ON UNIT WIDTH x NUMBER OF UNITS. ACTUAL OVERALL WIDTH MAY INCREASE DUE TO SITE CONDITIONS, MATERIAL TOLERANCES, FAILURE TO REMOVE CLOSE -UP MATERIAL, AND / OR OTHER FACTORS THAT ARE BEYOND THE CONTROL OF BUILDING MANUFACTURER TYP. GROUND ANCHOR SECTION D -D K FDI 24" MIN. 32" MAX. END HEADER 16" LL PIER TIE -DOWN AT MATELINE P.T. 2x8 SHIMS 4 "x8 "x16" CAP BLOCK 8 "x8 "x16" CMU'S -. 't PAD 16" SECTION A -A CRIMP STRAP WITH A LISTED STRAP CRIMP OR PRE MANUFACTURED CONNECTOR FRAME TIE -DOWN STRAP MAY BE INSTALLED ABOVE OR BELOW I -BEAM 0 = FRAME TIES F. T. FASTENED TO GROUND ANCHOR FIELD CONDITIONS WITH DRY STACK PIERS GREATER THAN 34" SHALL REQUIRE FOUNDATIONS TO BE ENGINEERED BEYOND THIS APPROVAL. MAXIMUM WIND SPEED 175 MPH. ASCE -7 -10 ALL TIE DOWN ANCHORS SHALL HAVE MINIMUM 4725 LB. CAPACITY AND SHALL BE INSTALLED IN ACCORDANCE WITH THEIR FLA. LISTING 18" MIN. HEIGHT 34" MAX. HEIGHT TO BOTTOM OF- FLOOR JOIST EXTERIOR SIDEWALL CHASSIS TIE -DOWN STRAP 4 "x16 "x16" PAD OR - (2) -4 "x8 "x16" PADS A"-8"x16" CAP BLOCK 2x8 P.T. SYP #2 CAP. 8 "x8 "x16" CONCRETE MASONRY UNITS A IMETER PIER IN CORNERS AND ALONG I BEAMS FDI NOTE: PAD MAY BE EITHER 4 "x16 "x16" PAD OR (2) -4 "x8 "x16" PADS AS SHOWN 8 "x8 "x16" CONCRETE MASONRY UNITS 4 "x8 "x16" CAP BLOCK OR 2x8 P.T. SYP #2 CAP. STAGGER 4 "x8 "x16" W ISOLATED PIERS CONCRETE UNITS ® MATELINE AS SHOWN C HEAVY LOAD PIER AT MATE LINE FDI NOTE: CONCRETE UNITS MAY BE A COMBINATION OF 4" X 8" X 16 ", AND 4" X 16" X 16" UNITS �1 b i i 1; , S' , 0 ,• ,; 1• ANCHOR TYPES q (; ModSpace 5 ® o JOHN A. B O D IAK 5530 FIRST AVE NORTH ARCHITECT - AIA - SAINT PETERSBURG, FLORIDA 33710 FLORIDA LICENSE #AR0005065 M.D.S. 2730 12TH STREET SOUTH LISTING AGENCY SAINT PETERSBURG, FLORIDA 33705 / •�;;.,;�'�Y$�� PHONE #813- 898 -6004 % .• . DATE SCALE QUOTE SER. N0. 10/21/2013 -NTS- MDS007521 10/21 013 SIZE CODE TYPE USE CHEMO By REV. ATT76VAL # PAGE PER PRINT 2010 FBC V ALL MDS MDS007521 4 OF 4