13-1230-002TOP NUMBER INDICATES NO. OF STEEL STRAPS INSTALLED AT SUPPORT COLUMN LOCATIONS (EA. HALF)
Q:) BOTTOM NUMBER INDICATES NO. OF STUDS INSTALLED AT SUPPORT COLUMN LOCATIONS (EA. HALF)
ISOLATED COLUMNS ARE MANUFACTURED OF 2X4 SPF #2 LUMBER
STEEL STRAPS SHALL BE 1- 1 /2 "x3OGA. FASTENED EACH END WITH 6 .113 x 2 3/8" NAILS (GC 24).
IF SPACE REQUIRES DOUBLING UP OF STRAPS USE DOUBLE LAYER OF STRAPS AND THEN FASTEN
THROUGH BOTH STRAPS WITH 12 NAILS EACH END.
INSTALL STUDS ® 8" O.C.
TRIPLE WALL STUDS EACH CORNER
3" VTR
LAV
WC
3" TO WASTE TERM.
•
3 TON HVAC INSTALLED PER
MFG'R. SPEC. W /10 KW HEAT
STRIP 1005 CFM ® .5 IWC ESP
WITH FRESH AIR INTAKE
240V 1 0
CKT / IA & 2A
14" X 28" R/A GRILLE THRU WALL
m U
J
QF
CC
X,
= CN L
'N�il
L
C
C
a
LISTING AGENCY
APPROVAL
THESE PRINTS COMPLY WITH THE
FLORIDA MANUFACTURED BUILDING
ACT OF 1979 CONSTRUCTION CODES
AND ADHERE TO THE FOLLOWING
CRITERIA:
CONST. TYPE
VI
OCCUPANCY
B
ALLOWABLE #
OF FLOORS
1
WIND VELOCITY
146
FIRE RATING OF
EXTERIOR WALLS
0
PLAN NO.
MDS007521
ALLOWABLE
FLOOR LOAD
40/100
APPROVAL DATE
10/21/2013
M.D.S.
S`!h%!SQL
PANEL "A" KVA
GENERAL LIGHTING
.0035 KW SF x 1027 SF x 1.25 4.49
10 RECEPTS ® 180 VA /1000 1.8
1 FANS ® .3 KW x 1.25 .38
HVAC WITH 5 KW HEAT STRIP 5.9
TOTAL 12.57
TOTAL /240x1000 52.4
INSTALL 100 AMP PANEL 120/240V 10
ELECTRIC SCHEDULE
CIRCUIT #
DUPLEX REi EPT ® 18- AFF'
BREAKER
(AMPS)
DUPLEX RECEPT ® 42" AFF
1 & 2
_SWITCH -® 40" AFF -_
$T
- SWITCH -WITH. 10 MINUTE: DELAY FOR FAN
OT
THERMOSTAT ® 48" AFF
❑T
LIGHT OR A/C TIMER
20A 1P
INCANDESCENT LIGHT 60W. MAX.
9_W-p. WATER PROOF PORCH LIGHT 60W. MAX.
QJ
JUNCTION BOX
e
100 CFM EXHAUST FAN
EMERGENCY LIGHT 82" AFF
J BOXES ONLY FOR MANUAL PULL STATION
AND VISIBLE AUDIBLE ALARM.
® 48" &
84' AFF
J BOX ONLY FOR MANUAL PULL STATION
® 48" AFF
®
12 "x12" SUPPLY AIR REGISTER
RECESSED FLUORESCENT 87.6 W. MAX.
OELECTRICAL
CIRCUIT
PANEL "A" KVA
GENERAL LIGHTING
.0035 KW SF x 1027 SF x 1.25 4.49
10 RECEPTS ® 180 VA /1000 1.8
1 FANS ® .3 KW x 1.25 .38
HVAC WITH 5 KW HEAT STRIP 5.9
TOTAL 12.57
TOTAL /240x1000 52.4
INSTALL 100 AMP PANEL 120/240V 10
ELECTRIC SCHEDULE
CIRCUIT #
NOMENCLATURE
BREAKER
(AMPS)
WIRE SI
CU. NM
W/G
1 & 2
HVAC SIZED PER MFR. SPECS.
4 -11
LIGHTS RECEPTS
20A 1P
12-2
THE MAXIMUM DIFFERENCE IN FLOOR ELEVATION IN
PATH OF EGRESS SHALL NOT EXCEED 1/2-.
A TEST AND BALANCE REPORT WILL BE SUPPLIED
UPON COMPLETION OF BUILDING.
APPROVED
MIAMI -DADE COUN IRE DEPARTMENT
BLDG PERMIT FIRE ALARM
rlRE SUPPRESSION T WATER MAIN EXT.
DATE:
BY:
S 'A'SE APPR VW BUII 7Nd
(;� ModSpace
JOHN A. B O D Z IAK 5530 FIRST AVE NORTH
SAINT PETERSBURG, FLORIDA, 33710
ARCHITECT —AIA— FLORIDA LICENSE #AROQQ3*0F5
M.D.S. 2730 12TH STREET SOUTH Nit�Q075t••..�o,�,
SAINT PETERSBURG. FLORIDA 33705
LISTING AGENCY PHONE #813 -898 -6004r •< ',; 0 Dl�•,
DATE SCALE QUOTE SER. N0.
10/21/2013 -NTS- MDS007521
10/21/2013
SIZE CODE TYPE USE I ocrxw ar REV. I APP # PAGE
PER PRINT 2001 FBC VI E MDS 1. MDS007521 1 2 OF 4