13-1057R-008M11 a i' aw GAS RISER DIAGRAM. TABLE r -r LYETHYLENE PLASTIC PIPE (UNDERGROUND 180'-0* DISTANCE 518,000 PROPANE TABLE r r O P 18 JPE. ft �VE GROUNDI MA DISTANCE 5f6 000 . PROPANE TABLE 402.4(25) STEEL PIPE 180'-0" DISTANCE 518 000 . PROPANE GAS F F.MR-AMMA i i PLUMBING SYMBOL LEGEND SYMBOL DESCRI71ON SANITARY LINE PLUMBING GENERAL NOTES: AD � (D THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND tt ALL BELOW GROUND SANITARY AND STORM PIPING AND FITTING GATE VALVE Coll EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE +11 WCO SHALL BE SCH 40 PVC . IN CONFORMANCE WTH ONE OF THE STANDARDS VTR VENT THRU ROOF PLUMBING SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE TIE - IN TO EXISTING LISTED IN TABLE 702.2 FBC (PLUMBING) DECK DRAIN DN 2010 EDITION OF THE FLORIDA BUILDING CODE, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES AND t2 ALL UNDERGROUND WATER PIPING SHALL BE CPVC PIPE ASTM D 2846 -L7 ID FLOOR DRAIN ORDINANCES. FIXTURE UNITS ALL ABOVE GROUND PIPING SHALL BE COPPER TYPE (ASTM -B -306). OIL SUPPLY WHR HOT WATER RETURN W.C.O. OR CPVC AS PER OWNER'S ELECTION. 1/2" ( THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE t3 ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING "K" 1 -1/2" 1/2" 1/2" SPECIFIED BY OWNER. SHALL BE COPPER TYPE (ASTM B -306). CLOTHES WASHER 2" COMPLETION AND TESTING OF THIS WORK. UPON FINAL 1/2- WITH DRAIN BOX: 2" DRAIN & (2) 1/2- H.B. W/ VACUUM BREAKER AND WATER HAMMER ARRESTORS L.SK LAUNDRY SINK ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION 1/2" ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL SPECIFIED BY OWNER. AUTHORITY SHALL BE FURNISHED TO THE OWNER. t4 NECESSARY ACCESSORIES SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P & T VALVES, ETC„ AS REQUIRED. ALL EXPOSED PIPING aAll MATERIALS AND EQUIPMENTS SHALL BE NEW, OF U.S. AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED BRASS MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND PIPE OR TUBE. PROVIDE SHUT OFF VALVES AND UNIONS TO ALL GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE COUPLINGS AS REQUIRED. FOR ALL COPPER PIPING CONTRACTOR PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF MUST USE 95/5 SOLDER. PROVIDE WATER HAMMER ARRESTORS SKILLED WORKMEN. TO EACH FIXTURE AS REQUIRED. (� �-J CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DRAWINGS TO FAMILIARIZE HIMSELF WITH THE OF 15 PROVIDE CLEANOUTS (WITH CHROME PLATED WALL OR FLOOR LOCATION ACCESS FRAMES AND COVERS AS REQUIRED) AT THE BASE OF ALL ALL EXISTING AND /OR PROPOSED UTILITY STUB OUTS, PIPING, INVERT, WASTE AND /OR VENT STACKS. PROVIDE PITCH PANS & LEAD EQUIPMENT, ETC., AND MAKE DUE ALLOWANCES FOR ANY CONDITION FLASHING FOR ALL SANITARY SYSTEM VENTS. AFFECTING HIS WORK. ALL HORIZONTAL WASTE PIPING 3" AND LARGER SHALL BE SLOPPED THE LOCATION OF ALL ITEMS SHOWN ON THE DRAWINGS ARE NOT DEFINITELY t8 AT 1/8 PER FOOT. / FIXED BY DIMENSIONS ARE APPROXIMATE ONLY.THE EXACT LOCATIONS ALL 2" HORIZONTAL WASTE PIPING SHALL BE SLOPPED NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE tT AT 1 4 PER FOOT. / DETERMINED BY THE CONTRACTOR AT THE PROJECT AND SHALL BE APPROVAL BEFORE ACTUAL INSTALLATION. �$ ALL POTABLE WATER USE FIXTURES SHALL COMPLY WITH "NO -LEAD" � ALL PLUMBING LINES SHOWN ARE IN THE APPROXIMATE LOCATION ONLY. REQUIREMENTS. •' FINAL PLUMBING LINES EXACT LOCATION WILL BE DETERMINE AT PROJECT ALL FIXTURES SHALL BE PROVIDED WITH FLEXIBLE SITE IN RESPONSE TO FIELD CONDITIONS. 19 (NON - HARDENING) WHITE SILICON TYPE GROUT WHERE AGAINST FINISHED WALL & FLOOR SURFACES. 7 ALL CUTTING REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT WILL BE DONE BY MECHANICAL CONTRACTOR. ANY CUTTING OF STRUCTURE ALL FIXTURES SUPPLIES AND STOPS SHALL BE CHROME PLATED (C.P.) MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO EXECUTION OF WORK. 0 ALL EXPOSED FIXTURE "P- TRAPS" SHALL BE MINIMUM 17 GAL. & CHROME GAS PRESSURE REGULATOR GENERAL CONTRACTOR TO COORDINATE LOCATIONS AND SIZES OF PLATED CAST BRASS OR 316 STAINLESS STEEL, ALL ACCESS DOORS WITH ARCHITECTURAL DRAWINGS. PROVIDE ANTI- SCALDING VALVE Q 110 f ON ALL TUBS AND SHOWERS. TEST TEE � INSTALL CONCRETE SUPPORT AT BASE (UNDERGROUND CONNECTION) OF OF THE THERMOSTATIC AND PRESSURE BALANCED TYPE ( ASSE 1016) UNION SOIL STACK, RAIN LEADER, ETC. -•- to a ALL ABOVEGROUND SANITARY AND STORM DRAINAGE PIPING AND FITTINGS & PLUMBING CONTRACTOR TO COORDINATE ALL WORK WITH OTHER TRADES. SHALL BE SCH 40 PVC . IN CONFORMANCE WTH ONE OF THE STANDARDS LISTED IN TABLE 702.2 FBC (PLUMBING) 24 ALL VENTS THRU THE ROOF TO BE AT LEAST 10' -0" AWAY FROM ANY AIR INTAKE TEE _TEST SEDMENT TRAP SHUT -OFF VALVE MP REGULATOR TEST TEE DETAIL N.T.S. a i' aw GAS RISER DIAGRAM. TABLE r -r LYETHYLENE PLASTIC PIPE (UNDERGROUND 180'-0* DISTANCE 518,000 PROPANE TABLE r r O P 18 JPE. ft �VE GROUNDI MA DISTANCE 5f6 000 . PROPANE TABLE 402.4(25) STEEL PIPE 180'-0" DISTANCE 518 000 . PROPANE GAS F F.MR-AMMA i i PLUMBING SYMBOL LEGEND SYMBOL DESCRI71ON � r SANITARY LINE -- - - - - -- VENT LINE AD COLD WATER LINE BV HOT WATER LINE BWV GATE VALVE Coll CLEANOUT +11 WCO WALL CLEANOUT VTR VENT THRU ROOF D. TIE - IN TO EXISTING � r INSTANT WATER HEATZ.-Im in PIPING DIAGRAM GAS HEATER NORITZ MODEL r EXTERIOR USE , 199 000 BTu/H MAX. 11.1 GPM AT 30 DEG. .9 OR APPROVED EQUAL WATER HAMMER ARRESTER SPECS. STANDARDS GO ABovEnNISHED GRADE GDL ABOVE ,, r FLOOR AD AREA DRAIN BV BALANCING VALVE BWV BACK WATER VALVE CV CHECK VALVE • CLEAN OUT CD CONDENSATE DRAIN D. DRAIN D.D. DECK DRAIN DN DOWN CW COLD WATER ID FLOOR DRAIN FU FIXTURE UNITS 1 F.O OIL SUPPLY INSTANT WATER HEATZ.-Im in PIPING DIAGRAM GAS HEATER NORITZ MODEL r EXTERIOR USE , 199 000 BTu/H MAX. 11.1 GPM AT 30 DEG. .9 OR APPROVED EQUAL WATER HAMMER ARRESTER SPECS. STANDARDS GO GARAGE DRAIN GDL GARAGE DRAIN LINE GV GATE VALVE HP HIGH PRESSURE HW HOT WATER O.F. EMERGENCY OVERFLOW PD PLANTER DRAIN PDL PLANTER DRAIN LEADER RWL RAIN WATER LEADER ST STORM SO/FT SQUARE FOOT S.O.V. SHUTOFF VALVE VB VACUUM BREAKER V VENT W WASTE WHR HOT WATER RETURN W.C.O. WALL CLEAN OUT PLUMBING FIXTURE CONNECTION SCHEDULE NO. DESCRIPTION DRAIN WATER REMARKS COLD HOT WC WATER CLOSET 3" 1/2" SPECIFIED BY OWNER. L LAVATORY 1 -1/2" 1/2" 1/2" SPECIFIED BY OWNER. SH SHOWER 1 -1/2" 1/2" 1/2" SP AFIEID BY VERVE T TUB 1-1/2* 1/2w 1/2w SPECIFIED T ANTI-SCALD VALVE BID BIDET 1 -1/2" 1/2" 1/2" SPECIFIED BY OWNER. SK SINK 1 -1/2" 1/2" 1/2" SPECIFIED BY OWNER. WM CLOTHES WASHER 2" 1/2' 1/2- WITH DRAIN BOX: 2" DRAIN & (2) 1/2- H.B. W/ VACUUM BREAKER AND WATER HAMMER ARRESTORS L.SK LAUNDRY SINK 1 -1/2" 1/2" 1/2" SPECIFIED BY OWNER. ALL PLUMBING FIXTURES AND FAUCETS TO COMPLY APPUCABLE STANDARD INDICATED IN THE FBC PILUMBING SECTIONS 406 THROUGH 421 AND ALL FIXTURES 1 FAUCETS TO COMPLY MIAMI-DAD ORDINANCE 8-31 MECHANICAL HMB ENGINEERING SERVICES P.A. AND ELECTRICAL ENGINEERING SERVICES CA 28443 Hector M. Blasco P.E. •• • 945 N1W 106 Ave. Cir. Miami FI 33172 HM8 Phone: 786-586-6284 i A*t2 I CONSULTING, 12940 SW 95th Avenue Miami, FL 33176 305.606.1617 AA260019SS ca I � � I � • I II s i � I r • • i f CN I •6 E§ •• I I I 2015-02-28 it r li I I� II I A ■