08-825-001WINDOWS (ZONE 4) TYPE CHECKED AREA GCP GCPi WIND PRESSURE WIND PRESSURE JOB NO. HEIGHT SIZE (psf) TYPE ALLOWABLE(psf) (p EXISTING (psf) ALLOWABLE(psf) ACCEPTANCE O(in) (in) NO S.F. + - + - + - + - 77.00 1 26 1/2"X26" 4.78 1.00 1.10 0.18 0.18 54.72 59.36 80.00 80.00 07- 0322.06 SH /IMP.GLASS TYPE A 2 37 "X38 3/8" 9.85 1.00 1.10 0.18 0.18 54.72 59.36 75.00 75.00 07- 0815.09 HR(XO) /IMP.GLASS TYPE A 3 53 1/8"X63" 23.24 0.90 1.00 0.18 0.18 50.09 54.72 75.00 75.00 07- 0815.09 HR(XO) /IMP.GLASS TYPE A 4 74 "X38 3/8" 19.71 0.92 1.02 0.18 0.18 51.01 55.65 75.00 75.00 07- 0815.09 EG.W HR(XO) /IMP.GLASS TYPE A 5 74 "X63" 32.37 0.88 0.98 0.18 0.18 49.16 53.80 63.80 63.80 07- 0815.09 HR(XO) /IMP.GLASS TYPE A 6 96 "X63" 42.00 0.85 0.95 0.18 0.18 47.77 52.40 56.20 56.20 07- 0815.09 HR(XOX) /IMP.GLASS TYPE A DOORS (ZONE 4) TYPE CHECKED AREA GCP GCPi WIND PRESSURE WIND PRESSURE JOB NO. HEIGHT SIZE (psf) TYPE ALLOWABLE(psf) (p EXISTING (psf) ALLOWABLE(psf) ACCEPTANCE 0 (in) No S.F. + - + - + - + - 77.00 A 2'- 0 "X6' -8" 13.33 0.96 1.06 0.18 0.18 52.87 57.51 75.00 75.00 07- 0629.10 FD(X) IMP.GLASS TYPE A 7 -- - - -T -- 3, -0" ZONE 5 1 O5 O O O O i O L I z M 0 / N/A MULLIONS TYPE CHECKED JAR WIND PRESSURE 07/07/08 WIND PRESSURE ACCEPTANCE JOB NO. HEIGHT CONSTRIBUTION (psf) TYPE ALLOWABLE(psf) (p No WIDHT 7 63" 106" 50.09 54.72 1 X2.75 77.00 77.00 06- 0125.07 qz = 0.00256 Kz Kzt Kd (1) V"2 H= 13' -8" EXPOSURE -C 1= 1.00 V =146 MPH Kz= 0.85 Kzt =1.00 F Kd= 1.00 1 qz = 0.00256 (0.85) (1.00) (1.00) (1.00) (146)2 qz = 46.38 PSF o w I z P =qz (Gcp +/- Gcpi) 0 i C -- 3' -0" ZONE 5 i / 3' -0" ZONE O 3' -0" ZONE 5 O FLOOR PLAN SC, 1/4' =1' ZONE 5 J O I O I _J O ±1;3 r7-rl �;- Z� - - L .4 J ;� Li OP�E. 0 (EG.W.) \ n 0 O3' -0" \ ZONE 5 \ =for FL , Air o F 7--- WIMMI REVISION�S MM C DRAWN AMF CHECKED JAR DATE 07/07/08 SCALE 1/4"=l JOB NO. BLANCO SHEET 1 A -1 OF 2 SHEETS