Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-203-003
U U m - U z n N O w z m s z O O O U O U z O U p a O w U w m D w ce Q U w O G G U w H Q U O w > O ce O 11 Q Q U z sn- m O U z v� Z �3 zpp Q w Up w p U G < U Om �p M U N xz v� LLJ U t=- PLUMBING GENERAL NOTES 1. CONTRACTOR IS TO BE STATE CERTIFIED AND INSURED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST FBC AND ALL LOCAL APPLICABLE ORDINANCES AND LAWS 2. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 3. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF MATERIALS AND EQUIPMENT. 4. COORDINATE ALL WORK WITH OTHER TRADES. 5. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 6. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES & 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 7. ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 8. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8- PER FOOT MINIMUM FALL FOR PIPES 3" OR LARGER AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2" OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT /ENGINEER. 9. WATER HAMMER: THE FLOW VELOCITY OF THE WATER DISTRIBUTION SYSTEM SHALL BE CONTROLLED TO REDUCE THE POSSIBILITY OF WATER HAMMER. A WATER- HAMMER ARRESTOR SHALL BE INSTALLED WHERE QUICK - CLOSING VALVES ARE UTILIZED. WATER- HAMMER ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WATER- HAMMER ARRESTORS SHALL CONFORM TO ASSE 1010. 10. ALL VALVES SHALL BE OF THE APPROVED TYPE AND COMPATIBLE WITH THE TYPE OF PIPING MATERIAL INSTALLED IN THE SYSTEM. 11. LOCATION OF FULL -OPEN VALVES. FULL -OPEN VALVES SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: a. ON THE BUILDING WATER SERVICE PIPE FROM THE PUBLIC WATER SUPPLY NEAR THE CURB. b. ON THE WATER DISTRIBUTION SUPPLY PIPE AT THE ENTRANCE INTO THE STRUCTURE. c. ON THE BASE OF EVERY WATER RISER PIPE. d. ON THE WATER SUPPLY PIPE TO EVERY WATER HEATER. e. SHUTOFF VALVES SHALL BE INSTALLED IN ON THE WATER SUPPLY PIPE TO EACH APPLIANCE OR MECHANICAL EQUIPMENT. 12. JOINTS BETWEEN DIFFERENT MATERIALS. JOINTS BETWEEN DIFFERENT PIPING MATERIALS SHALL BE MADE WITH A MECHANICAL JOINT OF THE COMPRESSION OR MECHANICAL - SEALING TYPE, OR AS PERMITTED IN §P605.22.1 AND §P605.22.2. CONNECTORS OR ADAPTERS SHALL HAVE AN ELASTOMERIC SEAL CONFORMING TO ASTM D 1869 OR ASTM F 477. JOINTS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 13. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 14. HOT WATER SUPPLY TO FIXTURES. THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED ON THE LEFT SIDE OF THE FIXTURE. FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. /3/4" H.B� FOR SPRIN SERVICE - SITE INVESTIGATION NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND /OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. MAXIMUM FLOW RATE AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURES FITTING AS PER TABLE 604.4 PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITY LAVATORY, PRIVATE 2.5 GPM ® 60 PSI LAVATORY, PUBLIC 0.5 GPM ® 60 PSI LAVATORY, PUBLIC, METERING OR SELF - CLOSING 0.25 GALLONS PER METERING CYCLE SHOWER HEAD 2.5 GPM ® 80 PSI SINK, FAUCET 2.5 GPM ® 60 PSI URINAL 1 GALLONS PER FLUSHING CYCLE WATER CLOSET 1.6 GALLONS PER FLUSHING CYCLE NOTE -1 PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION IN FIELD PRIOR TO COMMENCING WORK (E) - EXISTING TO REMAIN HAMMER ARRESTOR: NOTES HAMMER ARRESTOR (H.A) SHALL BE JOSAM ABSORBOTROM TYPE No. 75001 OR APPROVED EQUAL. - A WATER H.A SHALL BE INSTALLED WHERE QUICK - CLOSING VALVES ARE UTILIZED, UNLESS OTHERWISE APPROVED - SHALL BE LOCATED WITHIN AN EFFECTIVE RANGE OF YHE QUICK - CLOSING VALVE RUN IN WALL ;172„ H.B I1 � N ZO VENT 2 "OCD PVC PIPE- DISCHARGE OUTSI ® 6" A.F.G IN PERCOLATION ARE, RUN !;: WALL FOR DISTRIBUTION ( 1( /2" H.B ' I I ' 6 RUNNING 0 H. I I ' HER W.I.C. 1 S; IS IN MASTER BEDROOM yv /--3"0 I I (O.H) 4 HIS BATH �I 1 IN WALL& ' STORAGE I4 ' IN WALL I ' INSTANT H.W.H. -1 (SEE DETAILS & SPECS) _ - ._ p. i D i' i 2 "0(2FU) SINK DOWN IN WALL FOR SINK SERVICE REF Qn (O.H) DOWN IN WALL FOR REF SERVICE DINING - - -ROOM -------- DOWN & RUN IN WALL FOR HB SERVICE -1/2 "O CW (US) I� COVERED TERRACE rO"FOR ICE MAKER / _ WATER SUPPLY (SEE MANUFACT. SPECS) �2 "0 `4 "0(25FU) 1 -1/2 "0 TRAP FOYER (O.H)� - - FAMILY ROOM STUDY 11 111111111111 11111111 111111111111111111111 ENTRY uiiiiiiiiiiiiiiiiiiiis �--© RUNNING ' O.H. r- - - - - - - - - - - - - - - - - - - - - 2 CAR -- GARAGE � T 11FU) "0(36FU) 0(49FU) TO POOL SH DECK 1 IN WALL - - -- 3/4" H.B. FOR SPRINKLER SH SERVICE A _ CAB " 1 IN WALL , ARCHI tECTURE, PLAN LLC. =r 2 M.S.O.V WC 2 OVTR PLAY IN VERTICAL ROOM 3 "0 RUNNINj 2" O.H. I I AA26001717 1 -1/2 "O LAV ' 5200 SUNSET DRIVE C - - -- -- -- -- -- - -- -- MIAMI, FL. 33143 (O.H) 3 I T. 786.253.5530 3 DOWN & RUN R 305.661.2944 IN WALL FOR I I E. JUAN @CDG- CAP.COM DISTRIBUTION (I � 3 "0( ) (011) 3 I I GUEST BEDROOM I' �I I - DOWN & ' _ RUN IN I I M.S 0 VO ' 1 -1/2 "O 3 "OVTR WALL 3 ' IN VERTICAL I , 2 "OV 2'OTRAP 3 � 2 "OVENT s'•= C.0 1 e 2 "0 , I , O LAUNDRY SINK INSTANT H.W.H. -2 3 "O(6FU) (SEE ETAILS & SPECS)__ , ( I C'�."`.: •. EDROOM #3 I t OVERHEAD 9 I I O O.H 3 /4 "OCD ( ) & TRAP I' 2 "OCD PV PIPE fDISCHARG ~" , OUTSIDE ® " A. D " CD CD pQ 2 OCD (U.S) IN PERCOL TION AREA N ,� c* e 7 P IN WALL TO R N IN CEILING ACE 7 RUN IN , WALL W.I.C. W.I.C. I ALA O 1, 2 "OVTR TH 2„ 3 "0(13FU) " � • 1, � t 0 t _ 2 EIZ 3 0 8FU RUN IN TUB DTWN & JN , •, - - -- - IN WALL F - - - - - - - - - _ _ _ 9 UN , DISTRIBUTIO 1 WA L "O 1 1 RUN IN CAP -OFF AS ' REQUIRED (SEE NOTE -1) ' DENOTE PO DOWN & RUN IN I WALL ' -- - - - - - - - -� FACE OF WAL MANUFACTURER SPECS IN COMPLIANCE W /F.B.0 STAINL - STEEL . SCREWED TO MIN. 12" FROM STRUCTURE MODEL: N -120, 10.8 KW, 220V, 60 AIRS. THREADED WEIGHT: 8 POUNDS C.O. PLUG. 'TYPICAL WALL CLEANOUT DETAIL 11TH sC EACH A.A.V SHALL BE ACCESSIBLE FOR SERVICE AND REPAIR AIR REGISTER AND ACCESS PANEL. ID OPTION k1 6" ABOVE RIM MINIMUM. COMPLIANCE: UL. #499 OPTION #2 STUDDOR VENT AIR STANDARD: ANSI -Z, 10.03 ADMITTANCE VALVE. TESTED: APPLIED RESEARCH LAB 29 -580 TYPICAL MIAMI -DADE NOA # 97- 0627.16 OPTION #3 4" MINIMUM DIMENSIONS 7" W X 10" H X 2 -3/4 D CABINET OR ABOVE TRAP * ENERGY EFFICIENCY: UP TO 99.5% KITCHEN ISLAND SEAL. * NO R.V.D OR OVER FLOW REQUIRED AS PER MANUFACTURER SPECS. AIR AnKAITTANC:F VAI VF INSTANT WATER HEATER DETAIL MOUNTING DETAIL N.T.S. (TYPICAL OF TWO) N.T.S. FIXTURE CONNECTION SCHEDULE DOWN & RUN WASTE & SOIL WATER COLD IN WALL FOR WATER CLOSET 3" 1/2" KITCHEN SINK 1 TUB 2 "0 A.A.V 1/2" SERVICE - _ -____ 1 IN WALL 2" 1/2" 1/2" BIDET C.0 1 -1/2 "0 T 1/2.. IN WALL 2 REF -2 I I 1 1 -1/4" 1/2" ' 2 KITCHEN SINK 1 -1/2" 1/2" 1/2" DISHWASHER KS 1 "OHOSE - - PANTRY I 2" 1/2" 1/2" KITCHEN/ - - BREAKFAST 2 '0(2FU) LAV HER - - ' OO 2" BAT 1/2" REFRIGERATOR - - "0 HIS , ' Oc W.I.C. 1 I OO 3 0(5FU) 3 "0(19FU) I "0(21 �U) STEAM UNIT _ yv /--3"0 I I (O.H) 4 HIS BATH �I 1 IN WALL& ' STORAGE I4 ' IN WALL I ' INSTANT H.W.H. -1 (SEE DETAILS & SPECS) _ - ._ p. i D i' i 2 "0(2FU) SINK DOWN IN WALL FOR SINK SERVICE REF Qn (O.H) DOWN IN WALL FOR REF SERVICE DINING - - -ROOM -------- DOWN & RUN IN WALL FOR HB SERVICE -1/2 "O CW (US) I� COVERED TERRACE rO"FOR ICE MAKER / _ WATER SUPPLY (SEE MANUFACT. SPECS) �2 "0 `4 "0(25FU) 1 -1/2 "0 TRAP FOYER (O.H)� - - FAMILY ROOM STUDY 11 111111111111 11111111 111111111111111111111 ENTRY uiiiiiiiiiiiiiiiiiiiis �--© RUNNING ' O.H. r- - - - - - - - - - - - - - - - - - - - - 2 CAR -- GARAGE � T 11FU) "0(36FU) 0(49FU) TO POOL SH DECK 1 IN WALL - - -- 3/4" H.B. FOR SPRINKLER SH SERVICE A _ CAB " 1 IN WALL , ARCHI tECTURE, PLAN LLC. =r 2 M.S.O.V WC 2 OVTR PLAY IN VERTICAL ROOM 3 "0 RUNNINj 2" O.H. I I AA26001717 1 -1/2 "O LAV ' 5200 SUNSET DRIVE C - - -- -- -- -- -- - -- -- MIAMI, FL. 33143 (O.H) 3 I T. 786.253.5530 3 DOWN & RUN R 305.661.2944 IN WALL FOR I I E. JUAN @CDG- CAP.COM DISTRIBUTION (I � 3 "0( ) (011) 3 I I GUEST BEDROOM I' �I I - DOWN & ' _ RUN IN I I M.S 0 VO ' 1 -1/2 "O 3 "OVTR WALL 3 ' IN VERTICAL I , 2 "OV 2'OTRAP 3 � 2 "OVENT s'•= C.0 1 e 2 "0 , I , O LAUNDRY SINK INSTANT H.W.H. -2 3 "O(6FU) (SEE ETAILS & SPECS)__ , ( I C'�."`.: •. EDROOM #3 I t OVERHEAD 9 I I O O.H 3 /4 "OCD ( ) & TRAP I' 2 "OCD PV PIPE fDISCHARG ~" , OUTSIDE ® " A. D " CD CD pQ 2 OCD (U.S) IN PERCOL TION AREA N ,� c* e 7 P IN WALL TO R N IN CEILING ACE 7 RUN IN , WALL W.I.C. W.I.C. I ALA O 1, 2 "OVTR TH 2„ 3 "0(13FU) " � • 1, � t 0 t _ 2 EIZ 3 0 8FU RUN IN TUB DTWN & JN , •, - - -- - IN WALL F - - - - - - - - - _ _ _ 9 UN , DISTRIBUTIO 1 WA L "O 1 1 RUN IN CAP -OFF AS ' REQUIRED (SEE NOTE -1) ' DENOTE PO DOWN & RUN IN I WALL ' -- - - - - - - - -� FACE OF WAL MANUFACTURER SPECS IN COMPLIANCE W /F.B.0 STAINL - STEEL . SCREWED TO MIN. 12" FROM STRUCTURE MODEL: N -120, 10.8 KW, 220V, 60 AIRS. THREADED WEIGHT: 8 POUNDS C.O. PLUG. 'TYPICAL WALL CLEANOUT DETAIL 11TH sC EACH A.A.V SHALL BE ACCESSIBLE FOR SERVICE AND REPAIR AIR REGISTER AND ACCESS PANEL. ID OPTION k1 6" ABOVE RIM MINIMUM. COMPLIANCE: UL. #499 OPTION #2 STUDDOR VENT AIR STANDARD: ANSI -Z, 10.03 ADMITTANCE VALVE. TESTED: APPLIED RESEARCH LAB 29 -580 TYPICAL MIAMI -DADE NOA # 97- 0627.16 OPTION #3 4" MINIMUM DIMENSIONS 7" W X 10" H X 2 -3/4 D CABINET OR ABOVE TRAP * ENERGY EFFICIENCY: UP TO 99.5% KITCHEN ISLAND SEAL. * NO R.V.D OR OVER FLOW REQUIRED AS PER MANUFACTURER SPECS. AIR AnKAITTANC:F VAI VF INSTANT WATER HEATER DETAIL MOUNTING DETAIL N.T.S. (TYPICAL OF TWO) N.T.S. FIXTURE CONNECTION SCHEDULE ITEM WASTE & SOIL WATER COLD HOT WATER CLOSET 3" 1/2" - - TUB 2" 1/2" 1/2" JACUZZI 2" 1/2" 1/2" BIDET 1 -1/4" 1/2.. 1/2" LAVATORY 1 -1/4" 1/2" 1/2" KITCHEN SINK 1 -1/2" 1/2" 1/2" DISHWASHER 1" hose - - 1/2' CLOTHES WASHER 2" 1/2" 1/2" HOSE BIBB - - FLOOR DRAINS 2" MIN. 1/2" - - SHOWER 2" 1 /2" 1/2" REFRIGERATOR - - 1/2" - - NOTE: ALL P TRAPS SHALL BE CONSISTENT W /FIXTURE OUTLET SIZE. STEAM UNIT SPECS: M r STEAM MODEL: MS Super 1E, 10.0 KW, 240 V, 50 AMP. - USE UNIONS ON ALL PIPE CONNECTIONS - USE ONLY BRASS PIPING OR COPPER TUBING - DO NOT USE BLACK, GALVANIZED OR PVC PIPE. - WATER SUPPLY - y,2'" NPT - STEAM OUTLET - 1 NPT - DRAIN - 1/2" NPT - SAFETY VALVE - 3/4" NPT PLUMBING LEGEND - - SANITARY PVC PIPE Q HOT WATER PIPE - - - COLD WATER PIPE W.C. WATER CLOSET KS KITCHEN SINK LAV LAVATORY SH SHOWER DW DISHWASHER C.O. CLEAN OUT VTR VENT TO ROOF U.S. UNDERSLAB RT ROMAN TUB O.H OVERHEAD A.A.V AIR ADMITTANCE VALVE -1I WALL CLEAN OUT C.D CONDENSATE PVC PIPE NOTE: ALL SANITARY PIPE 2 1/2 "0 OR SMALLER SHALL RUN ® 1/4" SLOPE PER L.FT. 3" AND LARGER ® 1/8" SLOPE PER L.FT. NOTE -3 PROVIDE AIR CHAMBER AT ALL LAV, SINK, BATHTUB, SHOWER, WC, WASHING MACH. BOX, ICE MAKER. NOTE: ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE ® 110', (TYPICAL) TNT OF CONNECTION f (SEE NOTE -1) WALL FQQR ' DISTRIBUTI I I II J C 2 "OVTR ' BEDROOM #2 I IIC.O , OH (D- 1 -1/2 "0 6 RUN IN I LA O.H. QI ' 1 RUN IN AT: I WALL FCO (2WAY) 3/4" H.B. (IRON BODY) - - FOR SPRINKLER SEAL - EXISTING (SEE NOTE -1) LAV « I SERVICE P ":t .(O 4 "0 PVC SAN PIPE ® 1/8" SLOPE TO EXISTING SEWER LATERAL (SEE SITE PLAN FOR I CONTINUATION & UNDERGROUND ' /4 :WP SERVICE FROM , SEE NOTE --1) b. ' -'.OUSE SERVICE, 0 EXCEPT H IN C I•iLT='R BOX. REFER TO SITE PLAN FOR _ C T LOCATION NOTE: -2 NOTES: 11NDERGROU�.D 1 "0 CWP ALL PLUMBING WATER DEVICE 1. FIXTURE AND BRANCH TERMINALS ONLY ON SAME FLOOR LEVEL. i 2. DO NOT REMOVE VALVE FROM PIPEWORK, SEWER GASSES CAN ENTER. 3. USE P.T.F.E. RVICE : M 1 "0 WATER PROVIDE SHUT -OFF VALVE (TEFLON) TAPE OR SEALANT ON THE THREADS TO ENSURE AIRTIGHT SEAL. R #2 (F-A' HOUSE HB, ONLY) WATER PIPING SIZE Q 1/2"0 CW /HW Q 1/2-0 CW Q 3/4 "0 CW /1 /2 "O HW Q 3/4 "0 CW /HW Q 1/2"0 HW ® 3/4 "0 CW p 1"0 CW @ 3/4 "0 HW ® 1 "0 CW 3/4 "0 HW 10 1 1/4 "0 CW NOTE: NO SPLICE ALOWED UNDER SLAB. 4. SCREW VALVE INTO 2 INCH FEMALE ADAPTER TO CONNECT BY SOLVENT WELD TO i': COT'.;. ;ETER BOX. REFER PIPEWORK. 1) SITS HLAN FOR EXACT 5. DFU (DRAIN FIXTURE UNIT) 2 INCH = 3 DFU'S. LOCATION 6. MAXIMUM BRANCH FIXTURE LOAD 2 INCHES = 6 DFU'S. 7. ALL DWV SYSTEMS MUST HAVE A MAIN VENT EXTENDED TO THE OPEN AIR. WATER METER #1 FROM 8. DO NOT INSTALL ON STACK VENTS VENT STACKS, OR RELIEF VENTS. EXISTING :" DOMESTIC I I OPTION #1: WHEN THE VALVE IS LOCATED IN A WALL RECESS BOX A REMOVABLE LOUVER SHALL BE INSTALLED FOR VENTILATION, ACCESS IND INSPECTION. OPTION #2:THE VALVE MAY BE LOCATED ON A DOUBLE SHORT VERTICAL OFFSET BELOW THE FLOOD LEVEL RIM OF THE FIXTURE BEING SERVED. OPTION #3:THE VALVE MAY BE LOCATED ON THE HORIZONTAL FIXTURE DRAIN ARM A MINIMUM OF FOUR INCHES ABOVE THE FIXTURE TRAP. WATER SERVICE WATER METER #2 FROM EXISTING 1" DOMESTIC REFER TO SITE PLAN WATER SF 'iVICE FOR CONTINUATION PLUMBING FLOOR PLAN SCALE: 1/4 " NORTH [ J I, Jr REVISIONS: 01 CLIENT REQUEST AS -BUILT 11.9.13 DATE: 02.05.2013•w: SCALE AS SHOWN DRAWN BY: J.A.C.- CHECKED BY. J.A.Cf JOB NUMBER: 12141 Lrb P -1.1