13-203-002U U d Q m Ire I' I N O D m 0 cG G O 9 m O O 0 u V) V) O z O U 0 Cie O LLJ d LW Q w m w V O w w w V w w F Lij U w O G J C w O 0 r) Q V m V � O Z zz �0 �w LLJ� U � Hr) U � �u j M U N w V U �- w o� LoloUlf ,3mvr\L — DETECTOR A/C DIFFUSER AND OR FLOURESCENT LIGHT' SMOKE DETECTOR MOUNTING DETAIL N.T.S. SITE INVESTIGATION NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND /OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED i to ,MD (26GA) OUT THRU WITH CORROSION RESISTANT EN, WP /CAP AND B.D.D. -7 4" 3" 4 "0 GMD (26 GA) BATH UP THRU ROOF W /WP Cl CORROSION RESISTANT IN SCREEN & B.D.D. (AS PE 13- 606.AB. 1.3) (TYPICAI 2 "OCD PVC PIPE DISCHARGE OUTSIDE @ 6" A.F. IN PERCOLATION A WALL CAP FOR BATH OR DRYER EXHAUST N.T.S. AIR CONDITIONING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION ® CEILING GRILLE SEE SIZE SCHEDULE S.R. SIDE REGISTER A`MPS DUCT TO MATCH NECK SIZE TYP. CD CEILING DIFFUSER LIQ. RETURN AIR GRILL CG A.H.0 CEILING GRILL AIR HANDLER UNIT 1,625 VOLUME DAMPER U.O.N. UNLESS OTHERWISE NOTED 80 240 RTU TOP UNIT OHANDL 44 THERMOSTAT AHU AIR R UNIT _ AIR FLOW DIRECTION ( ARROWS DENOTE CU CONDENSING UNIT 1,625 1 WAY, 2 WAY, ETC., SEE PLANS EF EXHAUST FAN 80 240 CFM CUBIC FEET PER MINUTE �—� RETURN OR EXHAUST, SEE PLANS. O.A.I. OUTSIDE AIR INTAKE _Q / \ WALL MOUNTED SIDE REGISTER. B.D.D BACKDRAFT DAMPER FLEXIBLE DUCT (INSULATED) L *J EXHAUST FAN -�� UNDER CUT DOOR R RETURN AIR GRILLE / F.L.D FULL LOUVERED DOOR .A.G TRANSFER AIR GRILLE F.L.A. FULL LOAD AMPS NOTE: NOT ALL SYMBOLS MAY BE USED. NOTFS- 1. 4"0 G.M.D THRU WALL W /WP CAP, B.D.D AND CORROSION RESISTANT INSECT SCREEN. AS PER FBC 13- 606.AB. 1.3 2. 4 "0 G.M.D UP THRU CEILING TO ROOF W /WP CAP, BACKDRAFT DAMPER AND CORROSION RESISTANT INSECT SCREEN. AS PER FBC 13- 606.AB. 1.3 3. ALL DUCTWORK AND GRILLE LOCATIONS SHALL BE COORDINATED WITH ROOF STRUCTURE. 4. 10% 3-1/2" GMD (22 GA) FOR KITCHEN EXAUST UP THRU PARTITION TO ROOF W/ WP -CAP, BIRD SCREEN. 5. PROVIDE 10 "x10" FOR MAKE -UP AIR FOR DRYER 6. REFRIG. LINES RUN IN 4" PVC CONDUIT UNDERSLAB SPLIT SYSTEM NOTES: 1.ALL AIR HANDLERS UNITS SHALL BE INSTALLED ACCORDING WITH THE DUCTWORK SHOWN ON PLANS. CONTRACTOR SHALL VERIFY PLANS BEFORE ROUGH IN. 2.PROVIDE A/C UNITS WITH HEATING AND COOLING PROGRAMMABLE THERMOSTAT WITH ON -OFF SWITCH SUBB -BASE. 3.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ENGINEER PRIOR TO ROUGH IN. SHOP DRAWINGS SHALL DETAIL ALL LINE SIZES, BENDS, AND LENGTHS AS WELL AS CONTROL DEVICES. 4.PROVIDE PROPER VIBRATION ISOLATORS AS PER ISOLATION MANUFACTURER'S RECOMMENDATIONS. PROVIDE FILTER RACK UNDER AHU. RETURN AIR THROUGH LOUVERED DOOR UNLESS OTHERWISE NOTED. 5.INSULATE REFRIGERANT SUCTION LINE WITH 1/2" FIRE RETARDANT ARMAFLEX. 6.INSTALL CHEMICAL DRYER AND STRAINER IN REFRIGERANT LIQUID LINES. 7.PROVIDE BUILT -IN DISCONNECT WITH ALL AIR HANDLING UNITS. &PROVIDE ALL UNITS WITH PROGRAMMABLE THERM OSTAT/HU MIDI STAT. 9.CONFIRM THE PROVISION OF EMERGENCY USE HEAT STRIPS WITH OWNER PRIOR TO BID. REPORT DISCREPANCIES TO ENGINEER. CONDENSING UNIT SCHEDULE DESIGNATION TOTAL SENSIBLE Wb UU I VOL I S PHASES , ,,,- A`MPS FUSES I MANUFAC. UNIT LIQ. SUC. ICOND. AHU -1 1,625 49.5 35.3 67 80 240 1 10 44 60 RHEEM RHPL- HM4824JC 3/8 1/2 1 AHU -2 1,625 49.5 35.3 67 80 240 1 10 44 60 RHEEM RHPL - HM4824JC 3/8 1/2 1 HVAC CONTRACTOR SHALL VERIFY ALL ELECTRICAL INFORMATION AND EXISTING CONDITIONS PRIOR TO PURCHASE AND INSTALLATION. IF ANY CONFLICT CONTACT ARCHITECT CONDENSING UNIT SCHEDULE DESIGNATION MBTUH TEMP. ENT. CONDENSER I NO ELECTRICAL DATA MANUFAC. REF. UNIT OBS OR SEER AREA SERVED REF. VOLTS PHASES WIRE AMPS FUSES CU -1 49.5 95 240 1 40 60 RHEEM 14AJM48A01 15.5 SHOWN R -410A CU -2 49.5 95 240 1 40 60 RHEEM 14AJM48AOI 15.5 SHOWN R -410A - HVAC CONTRACTOR SHALL VERIFY ALL ELECTRICAL INFORMATION AND EXISTING CONDITIONS PRIOR TO PURCHASE AND INSTALLATION. IF ANY CONFLICT CONTACT ARCHITECTS. 6 GA) EXHAUST 4RTITION TO ROOF WITH ;ORROSION B.D.D. 13- 606.AB. 1.3 PVC PIPE kRGE ,E ® 6" A.F.G ;COLATION AREA AD (26 GA) BATH ST UP THRU ROOF CAP CORROSION 'ANT INSECT N & B.D.D. AL) R FBC 13- 606.AB. 1.3 MECHANICAL FLOOR P1_.N.N SCALE: 1/4" = V -0" HVAC DESIGN REQUIRE REQUIREMENT DESCRIPTION REQUIRED YES I NO DUCT SMOKE DETECTOR x FIRE DAMPER x SMOKE DAMPER x FIRE RATED ENCLOSURE x FIRE RATED ROOF/FLOOR x CEILING ASSEMBLY x FIRE STOPPING x SMOKE CONTROL x ILI - El J L AR-CHI CTURE PLAN LLG AA26001717 5200 SUNSET DRIVE MIAMI, FL. 33143 T. 786.253.5530 F. 305.661.2944 E: JUAN @CDG- CAP.COM Ow v M �Q Q Q r� QQN Q o ce Q QOM I---I W O o 00 ._j c� cc W H Q � OC,� O C/] SEAL: " u y� �.,1iti5�01� REVISIONS: &CLIENT REQUEST AS -BUILT 08.26.13 DATE 02.05.2013 SCALE AS SHOWN DRAWN BY. J.A.C. CHECKED BY: J.A.C. JOB NUMBER 12 -141 M -1.1