12-1316-00410
1
NOTE: EXIT LIGHTS & EMERGENCY LIGHTS SHALL BE CONNECTED AHEAD - - - - - - - -
OF SWITCH LEG IN THAT GROUP
18 DOWN TO DOWN TO J❑ X A/C
A18,20 SWITCH
A2,4
j
J1 NEW J BOX
1 181 EXIST. LIGHT
EXIST. LIGHT 23b 18
23b
18
EX EX
NOTE: ALL ELECTRICAL RECEPTACLES & LIGHTING
EXISTING TO REMAIN. NO ADDITIONAL ELECTRICAL WORK
Loft Electrical & Liahtina Plan
1/411 =1' -011
`E]
18
. LIGHT
A23b
EXIST. LIGHT
18
23b
EX A7
rX E
NEW J BOX
NEW J BOX
ELECTRICAL NOTES
1. SCOPE OF WORK INCLUDES REMOVAL OF ELECTRICAL RECEPTACLES
IN DEMOLISHED WALL AND CAP AT NEAREST EXISTING WALL, REMOVE
AND DISCONNECT CEILING LIGHTS IN AREA AS SHOWN ON PLANS,
AND RELOCATE EXISTING FIXTURES IN NEW CEILING GRID.
2. ALL WORK SHALL COMPLY W/ LATEST EDITION OF NATIONAL ELECTRIC
CODE (N.E.C) AND ALL APPLICABLE CODES, RULES, REGULATIONS
AND ORDINANCES.
3. MINIMUM WIRE SIZE IS #12 COPPER WIRING. ALL CONDUCTORS SHALL
BE COPPER W/ THW INSULATION. ALL WIRING SHALL BE IN CONDUIT.
4. FIELD VERIFY EXIST. GROUNDING.
5. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL
CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE
COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE
BY THE OWNER IS REQUIRED.
6. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND
WORKMANSHIP TO BE FREE OF DEFECTS FOR A PERIOD OF 1 YEAR.
7. NEW 125 AMP PANEL, 1 PHASE, 3 WIRE, 240/120 VOLTS FLUSH MOUNTED.
Electrical Power Plan
1/411 =1' -011
LIGHT FIXTURE SCHEDULE
° °
EX
° °
NEW
E)EX
® EX
AEX
�EX
v
EXIST. PENDANT MOUNTED 481 0 °
FLOURESCENT LIGHT FIXTURE RELOCATE
TO REMAIN
NEW PENDANT MTD. FLOURESCENT
LIGHT FIXTURE EX
EXIST. PENDANT MOUNTED 481
FLOURESCENT LIGHT FIXTURE
TO BE RELOCATED
EXIST. SURFACE MOUNTED 48 "L
FLOURESCENT LIGHT FIXTURE
EXIST. PENDANT MOUNTED LIGHT A TELEPHONE/COMPUTER JACK
FIXTURE TO REMAIN
EXIST. "HI -HAT" LIGHT FIXTURE . EXIST. PENDANT MOUNTED LIGHT
TO REMAIN RELOCATE FIXTURE TO BE RELOCATED
EXIST. CLG. FAN TO REMAIN ONEW NEW "HI -HAT" LIGHT FIXTURE
TO MATCH EXIST.
EXIST. CLG. FAN TO BE RELOCATED
EXIST. EXIT LIGHT RELOCATE
XRAY MACHINE CONTROL BOX EMERGENCY LIGHT BATTERY PACK
NEW EXIT /EMERGENCY COMBO LIGHT ® WALL MTD. XRAY MACHINE
NOTE: EXIT LIGHTS & EMERGENCY LIGHTS SHALL BE CONNECTED AHEAD
OF SWITCH LEG IN THAT GROUP
Lighting Plan
1/411 =1' -011
� r
,'111, •��
.��. ter. �•�.
�_
apaa itecture
.3
v
5150 S.W. 75th Street, Miami, FL 33143
A&CM2186 ; - - _
Gregory A. Neville;
A.I.A. _
AP12197-
-Tel:
-
^ ^
305- 788 -3230
email: gnevillefl @yahoo.com
Consultant:
U
0
U
C:
C:
'-
O
Q�
-0
-0
O
O
r-
E
r'-
= o
y'
�0
N
C
U
co
J
Q U_
O Cz
CZ
cr
CD
�
O
'^
1 ` VJ
Client:
Dr. Leonard Rothenberg, DDE
7887 N. Kendall Drive
Suite 220
Miami, FL
33156
cember 17, 2012
ons:
F
Sheet Number:
El