13-1056-028t j
(a)
an
120/240V
BRANCH- CIRCUITS
LOCATION
PANEL
"A"
DUPLEX RECEPTACLE OUTLET 15A, 125V
�-
SIMPLEX RECEPTACLE OUTLET 15A, 125V
11•
.1 PH,3W
WIRE AND
CONDUIT
EXHAUST FAN
COMBINATION FAN/ LIGHT
-}
CEILING LIGHTING FIXTURE
®
SURFACE r
WALL MOUNTED LIGHTING FIXTURE
BRANCH CIRCUITS
FLOOD LIGHT
Q
LOCATION
WIRE AND
LIGHTING PANEL
FUSE OR DISCONNECT SWITCH
TELEPHONE OUTLET
Q
TELEPHONE OUTLET
WIRE AND
TELEVISION OUTLET
®
CONDUIT
E]PB
PUSHBUTTON
G
CHIME
WALL SWITCH 15A, 1.25V
$3
CONDUIT
$4
COVERED TERR.
D
SAFETY DISCONNECT SWITCH
JUNCTION BOX
O
F
FAN
OJ
DINING REC.
F/L
GFI
GROUND -FAULT INTERRUPTER
WP
WEATHERPROOF
SD
SMOKE DETECTOR
CO
CARBON MONOXIDE ALARM W /BATTERY
APPLIANCES
REFRIGERATOR
GREAT ROOM
1 F
DISHWASHER
•- i�■■■�■.
• r i
-�
DISPOSAL
M.BATH LTG.
111'
•
FAMILY RM
®M.EEMEE�
OVERHAND LTG
t i r
CHRISTMAS
-
■ J �
,
11
�
®��
111
1l#10GI' 3 #
® �
REFRIGERATOR
WALK IN • -
# `
•.t
�TOTAL 46,060
BBQ LT,
COOLER COND.
RECEPTACLE
TOTAL =4 5,4 00
(a) AFGI C/B
DEMAND LOAD = 34.4 KW
A/C @ 100010= 4200 FIRST 10 KW @ 100 % = 10.0 KW
HEAT @ 65% =5200 24.4 KW @ 40 % = 9.76 KW
A/C = 5.2 KW
24.96 KW (104A)
120/240V i 11
BRANCH- CIRCUITS
LOCATION
WIRE AND
DUPLEX RECEPTACLE OUTLET 15A, 125V
�-
SIMPLEX RECEPTACLE OUTLET 15A, 125V
DUPLEX FLOOR RECEPTACLE, 15A, 125V
WIRE AND
CONDUIT
EXHAUST FAN
COMBINATION FAN/ LIGHT
-}
CEILING LIGHTING FIXTURE
®
FLUORESCENT LIGHTING FIXTURE - SURFACE MTD.
WALL MOUNTED LIGHTING FIXTURE
UNDER CABINET FLUORESCENT LIGHTING FIXTURE
FLOOD LIGHT
Q
CEILING MOUNTED LIGHTING FIXTURE
p
LIGHTING PANEL
FUSE OR DISCONNECT SWITCH
TELEPHONE OUTLET
Q
TELEPHONE OUTLET
TELEVISION OUTLET
®
HI -HAT
E]PB
PUSHBUTTON
G
CHIME
WALL SWITCH 15A, 1.25V
$3
THREE WAY TOGGLE SWITCH
$4
FOUR WAY TOGGLE SWITCH
D
SAFETY DISCONNECT SWITCH
JUNCTION BOX
O
F
FAN
OJ
FAN AND LIGHT(3 -WIRE CKT)
F/L
GFI
GROUND -FAULT INTERRUPTER
WP
WEATHERPROOF
SD
SMOKE DETECTOR
CO
CARBON MONOXIDE ALARM W /BATTERY
M.BATH LTG.
BATH RECEPT.
OVERHAND LTG
BATH RECEPT.
CHRISTMAS
POOL LIGHT
# `
•.t
�TOTAL 46,060
(a) AFGI C/B A/C @ 100 %= 4200 DEMAND LOAD = 38.06 KW
(b) ON TIMER HEAT @ 65% =5200 0
(e) GFI FIRST 10 KW @ 100 /o = 10.0 KW
(d) RECONNECT 28.06 KW @ 40 % = 11.22 KW
A/C (7.15) = 5.2 KW
26.42 KW (110A)
(a)
(b)(d)
BIG(
NOTE
COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR
SHALL BENR LISTED OR LABELED
LOAD TABULATION
DEMAND A/C
PNL "A" = 34.4 52
PNL "B" = 3810 52
f • •' p rj.i
.. r, r, y.; rr o
ri
10.4
TOTAL = 45b KW (190A)
ELECTFR C L OTES
L ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT
COMPANY.
3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO.
AND ANSI/EIA/rIA -510
4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN N N COI1-
PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL
ENERGY EFFICIENCY CODES.
5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR
HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS.
ia. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSEE?
ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO
SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION,
AS REQUIRED.
1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE
MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A
SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR
SUC14 CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI-
NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE
OWNER
8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND
LEAVE COMPLETED WORK N A CLEAN, UNDAMAGED, AND FINISHED
CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION,
UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR
ABUTTING WORK TO BE PERFORMED BY OTHERS.
NOTES:
I- MAINTAIN 2 Ft. CLEAR HORIZONTALLY
ON FIRE WALLS.
2- MAINTAIN 411/2 FT. CLEARANCE BETWEEN
BOXES IN GARAGE CEILIW3.
3 -IN ALL AREAS SPECIFIED IN 210 -52
ALL 125V -15A AND 20A RECEPTACLES
SHALL BE LISTED TAMPER - RESISTANCE
RECEPTACLES.
4- PROVIDE ARC -FAULT PROTECTION PER
NEC 210.12(15) .SEE PANEL SCHEDULES.
5- EGRESS STAIRS ILLUMINATION SHALL
COMPLY WITH FLORIDA BUILDING
CODE RES 3132 0615,0160,0136
MIN. RFC INSIDE AND OUTSIDE
6- LIGHTING WIIL COMPLY W/F15C E 404.1
NEC 210.12(15) .5096 LAMPS TO 15E ENG EFF.
50 KW GAS GENERATOR
SEPARATELY NON - DERIVED
SYSTEM
2P -225A
-0 @ 104 (CU)-3/4"C
1 M/0 (CU) -3/4 "C
'♦ i
NRQ MA*
q •
r` i DIAGRAM
WT/01 ; i T
Ib_jU CWP (METAL)
BLDG. STEEL FOUNDATION
S. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET
WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND
SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC-
TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM,
UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO-
DUCT OF A SINGLE MANIPACTUR.ER.
10. ALL CONDUCTORS SHALL BE COPPER AND RUN N CONDUIT. WIRE
SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE
CsROtND CONDUCTOR PER NEC ARTICLE 250 -122.
IL LOCATION OR OULETS N ELECTRICAL DRAWINGS IS DIAGRAMMATIC:
CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS.
12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS.
13, A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES AIE BASED ON
A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. COW
TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER
AND FUSES SIZES N ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE
REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS,
AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE,
CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA
CAST. HACR CIRCUIT BREAKERS MAY BE USED N PLACE OF FUSES. USE
NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY WMEC 110 -26)
14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME
CKT (AFCI PROTECTED)
15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL 4 CsROUNDING
WIRE PER NEC ARTICLE 250 -140.
COMPLY WITH NEC 210.12(5)
SMOKE DETECTOR—, i
SWITCH
SWITCH LEG F
LINE SIDE 120V
OF SWITCH
PHASE CONDUCTOR
'jrjr#j I. i riffiNN9 .
CONNECTION DETAIL NTS.
NOTES:
1 -SMOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE)
WITH BATTERY BACK -UP AND SHALL BE CONNECTED
TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT
CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH
UNIT SHALL BE INTERCONNECTED(AFC1 PROTECTED)
2 -SMOKE DETECTOR SHALL BE LOCATED AT LEAST 3FT. FROM
ANY A/C DIFUSER,BATHROOM DOORS AND WITHIN 20FT. OF
COOKING APPLIANCE BE OF A PHOTOELECTRIC TYPE.
3 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS
SHALL COMPLY WITH NFPA 12 SEC2 -52.Ib , CEILING MOUNTS
NOT LESS THAN 4" FROM A WALL AND WALL MOUNTS AT LEAST 4B1
FROM CEILING AND NOT MORE THA 12" TO TOP OF DETECTOR.
JOB #: 013 -076
GUERRERO /GONZALEZ
ENGINEERS, INC.
t am
�`" Michael C. Guerrero. P.E.
Mechanical Eng. Lic. #15235
Rafael L Gonzalez, P.E.
< e Electrical Eng. Uc. #11057
Y 780 TAMUMI CANAL RD.
Miami, Florida 33144
Tel. (305) 262 -3844, Fax (305) 262 -8211
E -mail: PROJECTSOGUERREROGONZALEZE NGINEERS.WM
CA# 0007612
LEGEND
SPECIAL RECEPTACLE OUTLET
DUPLEX RECEPTACLE OUTLET 15A, 125V
�-
SIMPLEX RECEPTACLE OUTLET 15A, 125V
DUPLEX FLOOR RECEPTACLE, 15A, 125V
EXHAUST FAN
COMBINATION FAN/ LIGHT
-}
CEILING LIGHTING FIXTURE
®
FLUORESCENT LIGHTING FIXTURE - SURFACE MTD.
WALL MOUNTED LIGHTING FIXTURE
UNDER CABINET FLUORESCENT LIGHTING FIXTURE
FLOOD LIGHT
Q
CEILING MOUNTED LIGHTING FIXTURE
p
LIGHTING PANEL
FUSE OR DISCONNECT SWITCH
TELEPHONE OUTLET
Q
TELEPHONE OUTLET
TELEVISION OUTLET
®
HI -HAT
E]PB
PUSHBUTTON
G
CHIME
WALL SWITCH 15A, 1.25V
$3
THREE WAY TOGGLE SWITCH
$4
FOUR WAY TOGGLE SWITCH
D
SAFETY DISCONNECT SWITCH
JUNCTION BOX
O
F
FAN
OJ
FAN AND LIGHT(3 -WIRE CKT)
F/L
GFI
GROUND -FAULT INTERRUPTER
WP
WEATHERPROOF
SD
SMOKE DETECTOR
CO
CARBON MONOXIDE ALARM W /BATTERY
NOTE
COMBINATION CARBON MONOXIDE ALARM AND SMOKE DETECTOR
SHALL BENR LISTED OR LABELED
LOAD TABULATION
DEMAND A/C
PNL "A" = 34.4 52
PNL "B" = 3810 52
f • •' p rj.i
.. r, r, y.; rr o
ri
10.4
TOTAL = 45b KW (190A)
ELECTFR C L OTES
L ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT
COMPANY.
3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO.
AND ANSI/EIA/rIA -510
4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN N N COI1-
PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL
ENERGY EFFICIENCY CODES.
5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR
HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS.
ia. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSEE?
ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO
SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION,
AS REQUIRED.
1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE
MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A
SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR
SUC14 CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI-
NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE
OWNER
8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND
LEAVE COMPLETED WORK N A CLEAN, UNDAMAGED, AND FINISHED
CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION,
UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR
ABUTTING WORK TO BE PERFORMED BY OTHERS.
NOTES:
I- MAINTAIN 2 Ft. CLEAR HORIZONTALLY
ON FIRE WALLS.
2- MAINTAIN 411/2 FT. CLEARANCE BETWEEN
BOXES IN GARAGE CEILIW3.
3 -IN ALL AREAS SPECIFIED IN 210 -52
ALL 125V -15A AND 20A RECEPTACLES
SHALL BE LISTED TAMPER - RESISTANCE
RECEPTACLES.
4- PROVIDE ARC -FAULT PROTECTION PER
NEC 210.12(15) .SEE PANEL SCHEDULES.
5- EGRESS STAIRS ILLUMINATION SHALL
COMPLY WITH FLORIDA BUILDING
CODE RES 3132 0615,0160,0136
MIN. RFC INSIDE AND OUTSIDE
6- LIGHTING WIIL COMPLY W/F15C E 404.1
NEC 210.12(15) .5096 LAMPS TO 15E ENG EFF.
50 KW GAS GENERATOR
SEPARATELY NON - DERIVED
SYSTEM
2P -225A
-0 @ 104 (CU)-3/4"C
1 M/0 (CU) -3/4 "C
'♦ i
NRQ MA*
q •
r` i DIAGRAM
WT/01 ; i T
Ib_jU CWP (METAL)
BLDG. STEEL FOUNDATION
S. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET
WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND
SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC-
TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM,
UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO-
DUCT OF A SINGLE MANIPACTUR.ER.
10. ALL CONDUCTORS SHALL BE COPPER AND RUN N CONDUIT. WIRE
SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE
CsROtND CONDUCTOR PER NEC ARTICLE 250 -122.
IL LOCATION OR OULETS N ELECTRICAL DRAWINGS IS DIAGRAMMATIC:
CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS.
12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS.
13, A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES AIE BASED ON
A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. COW
TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER
AND FUSES SIZES N ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE
REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS,
AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE,
CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA
CAST. HACR CIRCUIT BREAKERS MAY BE USED N PLACE OF FUSES. USE
NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY WMEC 110 -26)
14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME
CKT (AFCI PROTECTED)
15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL 4 CsROUNDING
WIRE PER NEC ARTICLE 250 -140.
COMPLY WITH NEC 210.12(5)
SMOKE DETECTOR—, i
SWITCH
SWITCH LEG F
LINE SIDE 120V
OF SWITCH
PHASE CONDUCTOR
'jrjr#j I. i riffiNN9 .
CONNECTION DETAIL NTS.
NOTES:
1 -SMOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE)
WITH BATTERY BACK -UP AND SHALL BE CONNECTED
TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT
CIRCUIT INTERRUPTER ALL SMOKE DETECTORS WITHIN EACH
UNIT SHALL BE INTERCONNECTED(AFC1 PROTECTED)
2 -SMOKE DETECTOR SHALL BE LOCATED AT LEAST 3FT. FROM
ANY A/C DIFUSER,BATHROOM DOORS AND WITHIN 20FT. OF
COOKING APPLIANCE BE OF A PHOTOELECTRIC TYPE.
3 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS
SHALL COMPLY WITH NFPA 12 SEC2 -52.Ib , CEILING MOUNTS
NOT LESS THAN 4" FROM A WALL AND WALL MOUNTS AT LEAST 4B1
FROM CEILING AND NOT MORE THA 12" TO TOP OF DETECTOR.
JOB #: 013 -076
GUERRERO /GONZALEZ
ENGINEERS, INC.
t am
�`" Michael C. Guerrero. P.E.
Mechanical Eng. Lic. #15235
Rafael L Gonzalez, P.E.
< e Electrical Eng. Uc. #11057
Y 780 TAMUMI CANAL RD.
Miami, Florida 33144
Tel. (305) 262 -3844, Fax (305) 262 -8211
E -mail: PROJECTSOGUERREROGONZALEZE NGINEERS.WM
CA# 0007612