Loading...
13-1056-023SYMBOL DESCRIPTION PLUMBING FIXTURE SANITARY LINE — — — -- VENT LINE SD STORM DRAIN LINE —�- —+- SAFEWASTE LINE CD CONDENSATE LINE 0.25 gallon GATE VALVE: - COLD WATER LINE — HOT WATER LINE P- PLUMBING FIXTURE DESIGNATION AAV AIR ADMITANCE VALVE EGO FLOOR CLEAN OUT 1.50 FLOOR PENETRATION Ll MECHANICAL SHOCK 60 ARRESTOR WCO WALL C;LEANOUT VTR VENT THRU ROOF COVER SECURED WITH SCREW5 THREADED G.O. FLUG FIN. G —RARE EXTERIOR T t FE MAXIMUM FLOW RATES AND CONSUMPTION TABLE 604.4 PLUMBING FIXTURE FLOW RATE FLOW PRESSURE OR FIXTURE FITTING (gpm) (psi) LAVATORY, PRIVATE 1.0 60 LAVATORY, PUBLIC, (METERING) 0.25 gallon TANK WATER CLOSET 3" per metering — - -- cycle LAVATORY LAVATORY, PUBLIC, (OTHER THAN METERING) 0.50 60 SHOWER HEAD 1.50 80 SINK FAUCET 1.50 60 WATER CLOSET 1.28 gallons per — 2" flushing cycle 1/2° DISHWASHER (RESIDENTIAL) 6.5 gals. per cycle or KITCHEN SINK 2" less (energy star/water .� 1/2" sense certified) HAND SINK WASHING MACHINES water factor of 8 or lower 1/2" 1/2'° (energy star /water sense CLOTHWASHER 3" certified) 1/2'° M 0 c+3%Ir101 002r =110 ,ADJUSTABLE LOLL Ti— TREADED G.O. F'LUG—� FIN. FLOOR -7 i/ 5LIF JOINT RMIIIIIIIIII 5TAINLE55 5TEEL COVER 5CREWEE> TO THREADED G.O. PLUMBING FIXTURE CONNECTION SCHEDULE U) DRAWN BY: VOLTS WATER G * G DESCRIPTION WASTE VENT REMARKS COED HOT TANK WATER CLOSET 3" -- 1/2" - -- AS PER ARCHITECTURAL LAVATORY 2" 2" 1/2" 1/2" AS PER ARCHITECTURAL SHOWER 2" -- - 112" 1/2" AS PER ARCHITECTURAL BATHTUB 2" ___. 1/2° 1/2" AS PER ARCHITECTURAL KITCHEN SINK 2" 2" 1/2" 1/2" AS PER ARCHITECTURAL HAND SINK 2" 2" 1/2" 1/2'° AS PER ARCHITECTURAL CLOTHWASHER 3" 2" 1/2'° 1/2" AS PER ARCHITECTURAL DISHWASHER 1 " SW __._. ___ 1/2." AS PER ARCHITECTURAL NOTES: 1.— All exposed trim, such as P -- traps, angle stops, and supplies shall be chrome plated, 2. -- All fixtures shall comply with Reference Standards as per 2010 FB0 Plumbing 406 through 421. ---l" AIR GAP DRAIN VALVE r WATER HEATER NOTES ELEMENT WATTAGE MODEL GALLON AT 240V _ MANUFACTURER PIPE EF CAPACITY FITTING STANDARD MAXIMUM ECRT -80 80 4500 6000 A.O. SMITH 3/4" .93 ECRT -52 50 1 4500 6000 1 A.L. SMITH 1/2° 93 SHUT -OFF- VALVE (apt. 1/2" H /2" GVD SHUT -OFF VALVE (opt.) EL. L worcbi.tectL 13131 S.W. 132 5TREET SUITE 104 MIAMI, FLORIDA 33186 T. (305) 278 -777G F. (305) 278 -7473 W W W. BELLON M I LAN E5. COM AA- 2GO02G I G ARCHITECTURE LAND PLANNING INTERIORS CONSTRUCTION MANAGEMENT CONSULTANTS U) DRAWN BY: VOLTS MAX, AMPS AT 220V G * G DATE: 8 -20 -13 L.L 220 19 U— "" ] EL. L worcbi.tectL 13131 S.W. 132 5TREET SUITE 104 MIAMI, FLORIDA 33186 T. (305) 278 -777G F. (305) 278 -7473 W W W. BELLON M I LAN E5. COM AA- 2GO02G I G ARCHITECTURE LAND PLANNING INTERIORS CONSTRUCTION MANAGEMENT CONSULTANTS MARKIDATE IDE5CRIPTION PROJECT No. U) DRAWN BY: AM CHECKED BY: G * G DATE: 8 -20 -13 L.L U— "" ] J W U .J O � 4 Z 0 ~ C� M o U MARKIDATE IDE5CRIPTION PROJECT No. 1308 DRAWN BY: AM CHECKED BY: G * G DATE: 8 -20 -13 .o- LEOPOLDO BELLON, AIA (AR -8737) JOB J: 013 -076,. ft4..o"Y �, � 15HEET TITLE GUERRERO /GONZALfZCx >.. C ENGINEERS, INC. "` CHEDULES, NOTES Michael C. Guerrero, P.E. DETAILS Mechanical Eng. Uc. #15235 Rafael L Gonzalez, P.E. 4 Electrical Eng. Lic. #11057 780 TAMIAMI CANAL RD. Miami, Florida 33144 Tel. (305) 262 -3944, Fax (30 —8 1 V E —mail: PRIIECTS000EJBt EERS.COM CA# 0007612 SHEET 3 OF 3