13-872-026j IL 2" VTR
2" 1
SH LAV I JIB 2" VTR
1 2"
WC 3" (5 DFU) LAV I WC
3" 3"
EXIST. 2 —WAY 4"
FCO
3" (5 DFU)
3" (11 DFU)
m
2" MV
1
SINKDYy
,A
\-3" (21 DFU) Jig" VTR 3" (9 DFU)
EXISTING 4" SAN.'
SINK 2"
2"
2"
� SANITARY RISER
P'2 NOT TO SCALE
wC
3" (7 DFU)
,IL 2" VTR
I
LAV
VENT PIPE THREADED COUNTERSUNK
CLEANOUT PLUG
COVER
CLEANOUT I
SANITARY STACK
`— COUNTERSUNK SCREW
9
PIPE SIZE
CLEANOUT TEE & ACCESS COVER
CLEAN -OUT DETAILS
N.T.S.
FAARI :9, .9
V4 Ifi
1 . 1
OP CABINETS
NET
TOE REVEAL
NICE
N.T.S.
■
QiI
3/4"
LAY
"
3/4"
R:�314
H B
1/2
DRAIN
PAN
WATER HEATER
LOCKINVAR
MODEL LTABOKK
80 GALLON
PLUMBING S'l/MBOL LEGEND
SYMBOL
DESCRIPTION
1 — 11 F.U.
SANITARY LINE
12 — 32 F.U.
3/4"
EXISTING SANITARY LINE
COLD WATER
61 — 113 F.U.
VENT LINE
3/4" BRONZE
COLD WATER LINE
155 — 330 F.U.
GATE VALVE
HOT WATER LINE
1/2"
1/2"
EXISTING COLD WATER LINE
1-1/4's
1/2
EXISTING HOT WATER LINE
WH_1 &
C.O.
CLEAN OUT
F.C.O.
FLUSH CLEAN OUT
%5
DENOTES NEW PIPE CONNECTION TO EXIST.
CW
COLD WATER
HW
HOT WATER
VTR
VENT THRU ROOF
—{�Q --
SHUT OFF VALVE
ROLLED LEAD FLASHING SET
1" DOWN INTO PIPE
PLUMBING VENT STACK (BY OTHERS)
APPLY ELASTIGUM ROOFERS CEMENT
AT EDGES OF ROOFING MEMBRANE.
12" FLANGE SET IN ELASTIGUM
ROOFERS CEMENT — PRIME
FLANGE BEFORE STRIPPING,
E
TWO —PLY STRIPPING
AS SPECIFIED
ROOF MEMBRANE,
/—AS SPECIFIED
NOTES
1. SHEET LEAD MINIMUM ❑F 2 -112 LBS, PER SQUARE FOOT,
V.T.R. /PIPE FLASHING DETAIL
-
N.T.S.
3/4" HOSE BIB WITH
SHUT OFF VALVE
AND VACUUM
BREAKER (TYP.)
WC
LAV
1./2"
3/4"
3/4"
REF
W s
3/4"
3/4"
DW
SINK
P-2 NOT TO SCALE
MANUFACTURER "LOCKINVAR"
MODEL LTA80KK, EFF. 0.92
80 GALLON, 240 V, 10, 4.5 KW
SERVICE AREA: AS SHOWN
HOT
WATER
2" A/C
CoNDENs
PITCH 1
PER FOC
12" DIAM.
CONCRETE PIPE
x-3/4" CRUSHED ROCK
CONDENSATE DRY WELL DETAIL
N.T.S.
REMOVABLE PERFORATED
VENTAn
A/C A/C UNIT
CONDENSATE TRAP
N.T.S.
LAVn
LAV
"
C 3/4
3/4" TUB
m
/2"
3/4
m A ,
HB
1/2"
1 -1�4" CW UNE
FRO WATER METER
S.O.V.
PLUMBING REFERENCE NOTES:
PLUMBING FIXTURES ARE TO COMPLY WITH MIAMI —DADE COUNTY
ORDINANCE,
ARTICLE III, SECTION 08 -31:
LAVATORY: 1,5 GPM AT 60 PSI
SHOWER HEAD: 1.5 GPM AT 80 PSI
WATER CLOSET: 1.28 GALLONS/F.C.
DISHWASHER: 6.5 GALLONS /CYCLE OR LESS
WASHING MACH: WATER FACTOR 8 OR LESS
DISHWASHERS & WASHING MACHINES CAN BE ENERGY STAR
COMPLIANT OR WATER SENSE CERTIFIED.
ALL PLUMBING FIXTURES TO COMPLY WITH THE FOLLOWING:
FBC 406 — AUTOMATIC CLOTHES WASHERS
FBC 407 — BATHTUBS
FBC 408 — BIDETS
FBC 409 — DISHWASHING MACHINES
FBC 416 — LAVATORY
FBC 417 - SHOWERS
FBC 418 — SINKS
FBC 420 — WATER CLOSETS
FBC 421 — WHIRLPOOL BATHS
INDIVIDUAL SHOWER AND TUB — SHOWER COMBINATION VALVES
SHALL BE BALANCED— PRESSURE, THERMOSTATIC OR COMBINATION
BALANCED— PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO
THE REQUIREMENTS OF ASSE 1016 OR ASME A112.18.1 /CSA
8125.1 AND SHALL BE INSTALLED AT THE POINT OF USE.
SHOWER AND TUB —SHOER COMBINATION VALVES REQUIRED BY
THIS SECTION SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE
MAXIMUM SETTING OF THE VALVE TO 120'F (49'C), WHICH SHALL
BE FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. IN —LINE THERMOSTATIC VALVES SHALL NOT BE
UTILIZED FOR COMPLIANCE WITH SECTION FRCP 424,
WATER HAMMER
ARRESTER SCHEDULE
P.D.I. SIZE*
VACUUM BREAKER
1 — 11 F.U.
EAT
12 — 32 F.U.
3/4"
VRAP
COLD WATER
61 — 113 F.U.
1"
3/4" BRONZE
in
155 — 330 F.U.
GATE VALVE
3/4" RELIEF
1/2"
1/2"
LINE TO
1-1/4's
1/2
THE OUTSIDE
WH_1 &
TEMPERATURE AND
1/2"
WH -2:
PRESSURE RELIEF
1 " HOSE
2
VALVE SHALL BE
1" OUTLET
SEE
ASME AND AGA
DRAIN
CHEDU LE
RATED TO MEET FHA
1/2"
;0S R DETAIL
SPECIFICATION FOR
2"
1/2"
100,000 BTU /HR
REFRIGERATOR
_ _
DRAIN PAN
_ _
WATER HEATER DETAIL
N.T.S.
2" A/C
CoNDENs
PITCH 1
PER FOC
12" DIAM.
CONCRETE PIPE
x-3/4" CRUSHED ROCK
CONDENSATE DRY WELL DETAIL
N.T.S.
REMOVABLE PERFORATED
VENTAn
A/C A/C UNIT
CONDENSATE TRAP
N.T.S.
LAVn
LAV
"
C 3/4
3/4" TUB
m
/2"
3/4
m A ,
HB
1/2"
1 -1�4" CW UNE
FRO WATER METER
S.O.V.
PLUMBING REFERENCE NOTES:
PLUMBING FIXTURES ARE TO COMPLY WITH MIAMI —DADE COUNTY
ORDINANCE,
ARTICLE III, SECTION 08 -31:
LAVATORY: 1,5 GPM AT 60 PSI
SHOWER HEAD: 1.5 GPM AT 80 PSI
WATER CLOSET: 1.28 GALLONS/F.C.
DISHWASHER: 6.5 GALLONS /CYCLE OR LESS
WASHING MACH: WATER FACTOR 8 OR LESS
DISHWASHERS & WASHING MACHINES CAN BE ENERGY STAR
COMPLIANT OR WATER SENSE CERTIFIED.
ALL PLUMBING FIXTURES TO COMPLY WITH THE FOLLOWING:
FBC 406 — AUTOMATIC CLOTHES WASHERS
FBC 407 — BATHTUBS
FBC 408 — BIDETS
FBC 409 — DISHWASHING MACHINES
FBC 416 — LAVATORY
FBC 417 - SHOWERS
FBC 418 — SINKS
FBC 420 — WATER CLOSETS
FBC 421 — WHIRLPOOL BATHS
INDIVIDUAL SHOWER AND TUB — SHOWER COMBINATION VALVES
SHALL BE BALANCED— PRESSURE, THERMOSTATIC OR COMBINATION
BALANCED— PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO
THE REQUIREMENTS OF ASSE 1016 OR ASME A112.18.1 /CSA
8125.1 AND SHALL BE INSTALLED AT THE POINT OF USE.
SHOWER AND TUB —SHOER COMBINATION VALVES REQUIRED BY
THIS SECTION SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE
MAXIMUM SETTING OF THE VALVE TO 120'F (49'C), WHICH SHALL
BE FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. IN —LINE THERMOSTATIC VALVES SHALL NOT BE
UTILIZED FOR COMPLIANCE WITH SECTION FRCP 424,
WATER HAMMER
ARRESTER SCHEDULE
P.D.I. SIZE*
CONNECTION SIZE
1 — 11 F.U.
1/2-
12 — 32 F.U.
3/4"
33 — 60 F.U.
1 "
61 — 113 F.U.
1"
114 — 154 F.U.
in
155 — 330 F.U.
1 "
*P,D.1, = PLUMBING AND DRAINAGE
INSTITUTE STANDARD WH -201
FIXTURE CONNECTION SCHEDULE
ITEM
WASTE &
SOIL (AS PER
TABLE 709.1)
WATER (AS PER TABLE 604,5)
COLD
HOT
WATER CLOSET
3"
1/2"
—
2"
1/2"
1/2"
BIDET
1-1/4-
1/2"
1/2"
ATORY
1-1/4's
1/2
1/2"
KITCHEN SINK
1 -1/2"
1/2"
1/2"
DISHWASHER
1 " HOSE
— —
1 /2"
CLOTHES WASHER
2"
1/2"
1/2"
HOSE BIB
— —
1/2"
SHOWER
2"
1/2"
1/2"
REFRIGERATOR
_ _
1 2"
_ _
4081 SW-74 Cou;t
Miami, FL 33155
786.615.2943
786.615.2945 Fak
cbravo66rvanx.c n _ ..
AA26002656
1132ECCt472
Carlos J. Bravo, R.A. AR17584
THE DESIGNS AND DRAWINGS PRESFMT HEREIN ARE THE SOLE
PROPERTY OF URVANX, INC, AND MAY NOT BE, OR
`
DUPLICATED n'HoUr SPECIFiC WRITTEN PERMISSION OF
URVANX, INC.
SEAL
IN 1,1Y PROFESSIONAL JUDGEMENT AND TO THE BEST OF
1,IY KNOWLEDGE AND BELIEF, THE PLANS AND
SPECIFICATIONS CONTAINED HEREIN COMPLY WTTH ALL
APPLICABLE BUILDING CODES.
Consultant:
Addition /Renovation
for
Salcines / Gonzalez
Residence
7800 SW 58 Ct
South Miami, FL 33143
Owner:
Jacqueline A. Salcines &
Rodolfo R. Gonzalez
7800 SW 58 Ct.
South Miami, FL 33143
(305) 669 -5236
Permit Set
REVISIONS
No DATE DESCRIPTION
WATER DISTRIBUTION &
SANITARY RISERS /
PLUMBING NOTES
SHEET TITLE
DATE 04.25.2014
DRAWN BY B.P. 1362
REVIEWED BY 9-J-B- PROJECT NO.
J