Loading...
13-872-025EXIST. 2 -WAY 4" FCO VERIFY EXISTING 4" SAN. LINE 5' -0" BEYOND BUILDING LINE — JIL 2" VTR „ I SH 2 LAY I WC /- 3" (5 DFU) » 2" VTR Jll WC LAV JDFU) - 3" 2" (5 ` -3" (21 DFU) JI 2" MV 12" VTR EXISTING 4" SAN. T W SINKLr" 2" 1M 3" (9 DFU) 2" AAV I SINK 6 1 DW 2" WC 2" \-3" (7 DFU) K_�� SANITARY RISER �-2NOT TO SCALE CLEANOUT SANITARY STACK y THREADED COUNTERSUNK CLEANOUT PLUG P �— COVER JIB 2" VTR I I ,AV . 2" r s COUNTERSUNK SCREW P PIPE SIZE CLEANOUT TEE & ACCESS COVER CLEAN -OUT DETAILS N.T.S. DP CABINETS " TOE REVEAL TTAN CE N.T.S. M M 3/4" LAY 3/4" SIN W 3/4" 3/4 HB W, 3/4" 1/2" DRAIN PAN WATER HEATER LOCKIWVAR MODEL LTA80KK 80 GALLON PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION 1 - 11 F.U. SANITARY LINE 12 - 32 F U. 3/4" EXISTING SANITARY LINE VACUUM BREAKER 61 - 113 F.U. VENT LINE 114 - 154 F.U. COLD WATER LINE TRAP WATER HOT WATER LINE 1/2" 3/4" BRONZE EXISTING COLD WATER LINE 1-1/4" GATE VALVE EXISTING HOT WATER LINE KITCHEN SINK C.O. CLEAN OUT F.C.O. FLUSH CLEAN OUT 0 DENOTES NEW PIPE CONNECTION TO EXIST. CW COLD WATER HW HOT WATER VTR VENT THRU ROOF —j>Q— SHUT OFF VALVE ROLLED LEAD FLASHING SET 1" DOWN INTO PIPE PLUMBING VENT STACK (BY OTHERS) APPLY ELASTIGUM ROOFERS CEMENT AT EDGES OF ROOFING MEMBRANE, FLANGE SET IN ELASTIGUM I� ROOFERS CEMENT - PRIME 1101N. FLANGE BEFORE STRIPPING, TWO -PLY STRIPPING AS SPECIFIED ROOF MEMBRANE, AS SPECIFIED N ❑TEr 1. SHEET LEAD MINIMUM DF 2 -112 LBS. PER SQUARE FDDT. V.T.R. /PIPE FLASHING DETAIL 3/4" HOSE BIB WITH SHUT OFF VALVE AND VACUUM BREAKER (TYP.) LAVn TUB HB r1 LAVn SH n C 3/4 n WC 3/4" TUB j1/2" 1/2» \-3/4" REF NOT • SCALE i -1 MANUFACTURER "LOCKINVAR" MODEL LTA80KK, EFF. 0.92 80 GALLON, 240 V, 10, 4.5 KW SERVICE AREA: AS SHOWN 3/4" SINK DW, 2" A/C CONDEN`. PITCH 1, PER FOC 12" DIAM. CONCRETE PIPE N3/4" CRUSHED ROCK CONDENSATE DRY WELL DETAIL N.T.S. REMOVABLE PERFORATED VENT C "° 3/4 "- HB 1/2" 1 -1/4" CW LINE FROM WATER METER S.O.V. PLUMBING REFERENCE NOTES: PLUMBING FIXTURES ARE TO COMPLY WITH MIAMI -DADE COUNTY ORDINANCE, ARTICLE III, SECTION 08 -31: LAVATORY: 1.5 GPM AT 60 PSI SHOWER HEAD: 1.5 GPM AT 80 PSI WATER CLOSET: 1.28 GALLONS /F.C. DISHWASHER: 6.5 GALLONS /CYCLE OR LESS WASHING MACH: WATER FACTOR 8 OR LESS DISHWASHERS & WASHING MACHINES CAN BE ENERGY STAR COMPLIANT OR WATER SENSE CERTIFIED. ALL PLUMBING FIXTURES TO COMPLY WITH THE FOLLOWING: FBC 406 - AUTOMATIC CLOTHES WASHERS FBC 407 - BATHTUBS FBC 408 - BIDETS FBC 409 - DISHWASHING MACHINES FBC 416 - LAVATORY FBC 417 - SHOWERS FBC 418 - SINKS FBC 420 - WATER CLOSETS FBC 421 - WHIRLPOOL BATHS INDIVIDUAL SHOWER AND TUB - SHOWER COMBINATION VALVES SHALL BE BALANCED- PRESSURE, THERMOSTATIC OR COMBINATION BALANCED- PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO THE REQUIREMENTS OF ASSE 1016 OR ASME A112.18.1/CSA B125.1 AND SHALL BE INSTALLED AT THE POINT OF USE. SHOWER AND TUB -SHOER COMBINATION VALVES REQUIRED BY THIS SECTION SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUM SETTING OF THE VALVE TO 1207 (49'C), WHICH SHALL BE FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER'S ;INSTRUCTIONS. IN -LINE THERMOSTATIC VALVES SHALL NOT BE UTILIZED FOR COMPLIANCE WITH SECTION FRCP 424. WATER HAMMER ARRESTER SCHEDULE HOT CONNECTION SIZE 1 - 11 F.U. WATER 12 - 32 F U. 3/4" 33 - 60 F.U. VACUUM BREAKER 61 - 113 F.U. H EACOLD 114 - 154 F.U. in TRAP WATER *P.D.I. = PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201 1/2" 3/4" BRONZE ATO RY 1-1/4" GATE VALVE RELIEF KITCHEN SINK 1 -1/2" LINE LINE TO r- DISHWASHER THE OUTSIDE WH_1 & TEMPERATURE AND CLOTHES WASHER WH -2: PRESSURE RELIEF 1/2" 2 VALVE SHALL BE 1" OUTLET SEE ASME AND AGA DRAIN SCHEDULE RATED TO MEET FHA REFRIGERATOR OR DETAIL SPECIFICATION FOR S 100,000 BTU /HR —DRAIN PAN WATER HEATER DETAIL N.T.S. 2" A/C CONDEN`. PITCH 1, PER FOC 12" DIAM. CONCRETE PIPE N3/4" CRUSHED ROCK CONDENSATE DRY WELL DETAIL N.T.S. REMOVABLE PERFORATED VENT C "° 3/4 "- HB 1/2" 1 -1/4" CW LINE FROM WATER METER S.O.V. PLUMBING REFERENCE NOTES: PLUMBING FIXTURES ARE TO COMPLY WITH MIAMI -DADE COUNTY ORDINANCE, ARTICLE III, SECTION 08 -31: LAVATORY: 1.5 GPM AT 60 PSI SHOWER HEAD: 1.5 GPM AT 80 PSI WATER CLOSET: 1.28 GALLONS /F.C. DISHWASHER: 6.5 GALLONS /CYCLE OR LESS WASHING MACH: WATER FACTOR 8 OR LESS DISHWASHERS & WASHING MACHINES CAN BE ENERGY STAR COMPLIANT OR WATER SENSE CERTIFIED. ALL PLUMBING FIXTURES TO COMPLY WITH THE FOLLOWING: FBC 406 - AUTOMATIC CLOTHES WASHERS FBC 407 - BATHTUBS FBC 408 - BIDETS FBC 409 - DISHWASHING MACHINES FBC 416 - LAVATORY FBC 417 - SHOWERS FBC 418 - SINKS FBC 420 - WATER CLOSETS FBC 421 - WHIRLPOOL BATHS INDIVIDUAL SHOWER AND TUB - SHOWER COMBINATION VALVES SHALL BE BALANCED- PRESSURE, THERMOSTATIC OR COMBINATION BALANCED- PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO THE REQUIREMENTS OF ASSE 1016 OR ASME A112.18.1/CSA B125.1 AND SHALL BE INSTALLED AT THE POINT OF USE. SHOWER AND TUB -SHOER COMBINATION VALVES REQUIRED BY THIS SECTION SHALL BE EQUIPPED WITH A MEANS TO LIMIT THE MAXIMUM SETTING OF THE VALVE TO 1207 (49'C), WHICH SHALL BE FIELD ADJUSTED IN ACCORDANCE WITH THE MANUFACTURER'S ;INSTRUCTIONS. IN -LINE THERMOSTATIC VALVES SHALL NOT BE UTILIZED FOR COMPLIANCE WITH SECTION FRCP 424. WATER HAMMER ARRESTER SCHEDULE P.D.I. SIZE CONNECTION SIZE 1 - 11 F.U. 1/2" 12 - 32 F U. 3/4" 33 - 60 F.U. 1" 61 - 113 F.U. 1 " 114 - 154 F.U. in 155 - 330 F.U. in *P.D.I. = PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201 FIXTURE CONNECTION SCHEDULE ITEM WASTE & SOIL (AS PER TABLE 709.1) WATER (AS PER TABLE 604.5) COLD HOT WATER CLOSET 3" 1/2" - - 2" 1/2" 1/2" BIDET 1-1/4" 1/2" 1/2' ATO RY 1-1/4" 1/2- 1/2- KITCHEN SINK 1 -1/2" 1/2" 1/2" DISHWASHER 1" HOSE - - 1/2" CLOTHES WASHER 2" 1/2" 1/2" HOSE BIB - - 1/2" - - SHOWER 2" 1/2" 1/2" REFRIGERATOR _ _ 1/2" n n 48$': SW 74 Court Miami, FL 33155 ry 786.615.2943 786.615.2945 Fax cbravo @urvanx.com AA26002656 ry' IB26001472 Carlos J. Bravo, R.A. AR17584 THE DESIGNS AND DRAWINGS PRESENT HEREIN B�ARE THE SOLE PRUPE CATED WnOOUr. SPEECIFFlCD*M,R1iATTENP ER�IISSroN ®oFO URVANX, INC. ..,.SEAL IN MY PROFESSIONAL JUDGEMENT AND TO THE BEST OF MY AND BELIEF, THE PLANS AND SPECIFICATIONS CONTAINED HEREIN COMPLY WITH ALL APPLICABLE BUILDING ODES. Consultant: Addition /Renovation for Salcines / Gonzalez Residence 7800 SW 58 Ct. South Miami, FL 33143 Owner: Jacqueline A. Salcines & Rodolfo R. Gonzalez 7800 SW 58 Ct. South Miami, FL 33143 (305) 669 -5236 Permit Set REVISIONS Na DATE DESCRIPTION A 108.13.14 I8LDG DEPT COMMENTS E .25.2014 B.P. 1362 Y C.J.B. PROJECT N0. SHEET