WATER DISTRIBUTION PLAN
j,J SCALE: 3/16" = 1' -0"
r
-••
-4981 SW 74 Court
Miami, FL 33155
786.615.2943
rt ry Po m - 786.615.2945 Fax
p w _ cbravo @urvanx.com
•; ., S F E_ -- t; 6 •t _
MASTER ; I,
BEDROOM
k
MY,
mr
_ II
LAY
I
I a MASTER � -
f E I ' BATH _ -
i :.
LAY
I TUB I
- - I_ - -- I C
T IT
v;r
I I
_ -- - - -° - ------------
RANGE
UPIM
} m YI I
Hit
o cl). I
I 3
3
REF. - - - --
LA,UNDRYI pk jC(O';. f
LIVING
�.; z I k
ROOM s II '
E _ ELECT.
PAI FL 'A' PANEL'B'
,
7 ,
HU -1
u I
G - - -- -
- -I^J ke
HU -2 Ll
P &T RELIEF LINE -
TERMINATE 6" AFG
POINTING DOWN—
m
GARAGE
1 -1/4" CW LINE
FROM WATER
METER
HB _\
Carlos J. Bravo, R.A. AR17584
THE DESIGNS AND DRAWINGS PRESENT HERON ARE THE SOLE
PROPERTY OF URVANX. INC. AND MAY NOT B COPIED OR
DUPUCATM WTMOUT SPECIFIC *RITTEN PER 'LISSX)N OF
URVANX. INC.
°�eYtc •°+'a. `ems ��,{
>' SEAL
IN MY PROFESSIONAL JUDGEMENT AND TO THE BEST OF
MY KNOWLEDGE
CONTAINED EREIN CA PLY AH ALL
APPLICABLE BUILDING CODES.
Consultant:
EXIST.
S.O.V. Addition /Renovation
for
Salcines / Gonzalez
Residence
7800 SW 58 Ct.
South Miami, FL 33143
Owner:
Jacqueline A. Salcines &
Rodolfo R. Gonzalez
7800 SW 58 Ct.
South Miami, FL 33143
(305) 669 -5236
Permit Set
REVISIONS
No DATE DESCRIPTION
A 08.13.14 BLDG DEPT COMWENTS
P -1
SHEET
PLUMBING NOTES:
1.-
ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH THE 2010 EDITION OF THE
FLORIDA BUILDING CODE, ASME CODE, AND AGA REQUIREMENTS.
14.- PLUMBING PIPING SHALL BE AS FOLLOWS:
20. -VENTS AND VENTING SYSTEMS:
- EXTENSION OF YEW PIPES THROUGH THE ROOF SHALL BE TERMINATED AT LEAST 12" ABOVE IT.
2.-
3.-
4.-
ALL WORK SHALL BE INSTALLED IN A NEAT AND ORDERLY MANNER WITH
CAREFUL CONSIDERATION GIVEN TO SUPPORTING AND PITCHING OF PIPING,
ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR. THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL
PERMITS, FEES, TAXES, TESTING, INSURANCE, SCAFFOLDING, AND OTHER ITEMS NECESSARY TO FULLY EXECUTE THE WORK.THE
PLUMBING CONTRACTOR SHALL INCLUDE ALL ITEMS NECESSARY TO PROVIDE A COMPLETE AND CODE ACCEPTABLE OPERATING SYSTEM.
THE PLUMBING PLANS ARE DIAGRAMMATIC AND DO NOT SHOW EVERY ITEM REQUIRED. THE PLUMBING
CONTRACTOR SHALL INCLUDE ALL ITEMS NECESSARY TO RENDER ALL SYSTEMS FULLY OPERATIONAL.
A) SANITARY WASTE AND VENT PIPING SHALL BE PLASTIC PIPE DWV SCHEDULE 40.
B) HOT AND COLD WATER PIPING SHALL BE COPPER, TYPE L, OR TYPE K, IN POLYETHYLENE SLEEVE BELOW GROUND AND TYPE K, L, OR M
ABOVE GROUND. HOT WATER PIPING SHALL BE INSULATED WITH 1" ARMAFLEX OR RUBATEX OR EQUAL.
C) CONDENSATE PIPING SHALL BE PLASTIC PIPE DWV SCHEDULE 40. PIPING SHALL BE INSULATED AS REQUIRED.
P) WATER VALVES FOR COPPER TUBING LINES SHALL BE BRONZE BODY WITH PRESSURE RATINGS OF 175 LBS., NON SHOCK COLD WATER AS
D•
MANUFACTURED BY NIBCO OR APPROVED EQUAL.
- A CONNECTION BETWEEN A VENT PIPE AND A VENT STACK SHALL BE AT LEAST 6" ABOVE THE FLOOD LEVEL
RIM OF THE HIGHEST FIXTURE SERVED BY THE VENT,
- ALL VENT AND VENT BRANCH -VENT PIPE SHALL BE SO GRADED AND CONNECTED AS TO DRAIN DRY.
- THE JUNCTURE OF EACH VENT PIPE WITH THE ROOF LINE SHALL BE MADE WATER TIGHT BY PROPER FLASHING. (SEE DETAIL).
21.- PLUMBING FIXTURES SHALL BE PROVIDED TO CONFORM IN QUALITY AND DESIGN WITH ONE OF THE STANDARDS
IN TABLE 46 -C OF THE FBC. FIXTURES CLEARANCE SHALL BE AS PER THE FBC
22. -THE WATER PIPE INSTALLED SHALL BE PROTECTED FROM WATER HAMMER BY THE USE OF AIR CHAMBERS OR
OTHER APPROVED DEVICES IN ALL FIXTURES IN CONFORMANCE WITH THE FBC,
WATER DISTRIBUTION &
SANITARY PLANS
5.-
6.-
7.-
THE PLUMBING CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING
CONDITIONS. THE PLUMBING CONTRACTOR SHALL VERIFY ALL EXISTING WASTE AND VENT LINES.
FULLY COORDINATE ALL MOUNTING HEIGHTS AND LOCATIONS WITH THE ARCHITECTURAL,
STRUCTURAL, CABINET, ELECTRICAL, AND AIR CONDITIONING PLANS BEFORE INSTALLATIONS.
NOTIFY THE ARCHITECT OR THE ENGINEER OF ANY DISCREPANCIES BETWEEN THE PROJECT
DOCUMENTS AND THE ACTUAL CONDITIONS PRIOR TO INSTALLATIONS OF ANY ELEMENT OR MATERIAL.
15.-THE WATER DISTRIBUTION SYSTEM SHALL BE PROTECTED AGAINST BACKFLOW, PROVIDE INCOMING WATER
BACKFLOW PREVENTION DEVICES AS SPECIFIED IN THE FLORIDA BUILDING CODE.
16.-PROVIDE THE WATER HEATER WITH AN APPROVED GALVANIZED DRAIN PAN WITH A MINIMUM OF 2" HIGH SIDES THE DRAIN PAN
SHALL BE EQUIPPED WITH A 3/4" MINIMUM DRAIN OUTLET LOCATED 1/2" ABOVE THE BOTTOM OF THE PAN. (SEE DETAIL).
17.-PRESSURE AND TEMPERATURE RELIEF VALVES SHALL BE INSTALLED FOR THE WATER HEATER AS PER FBC "SAFETY DEVICES ". (SEE DETAIL),
23. -THE HOT WATER SUPPLY TO ANY FIXTURE REQUIRING HOT WATER SHALL BE IN THE LEFT SIDE OF THE FIXTURE
UNLESS OTHERWISE SPECIFIED.
24.- INSTALL A THERMAL EXPANSION DEVISE TO CONTROL THE WATER PRESSURE TO LESS THAN THE PRESSURE SETTING
OF THE PRESSURE RELIEF VALVE ON THE WATER HEATER IF REQUIRED.
25.- INSTALL AN APPROVED WATER PRESSURE REGULATOR CONFORMING TO ASSE 1003 WITH STRAINER WHERE WATER
8.- ALL MATERIAL SHALL BE NEW AND FREE FROM DEFECTS.
9.- DO NOT COMPROMISE THE INTEGRITY OF STRUCTURAL ELEMENTS WHEN INSTALLING PIPE AND FIXTURES,
10, -ALL EXPOSED INTERIOR PIPING, FAUCETS, CLEAN -OUT GONERS, ETC, SHALL BE CHROME PLATED.
11.- ALL HOSE BIBBS AND FAUCETS W/ HOSE -END CONNECTIONS SHALL HAVE SHUT -OFF & VACUUM BREAKER.
12.- PROVIDE ACCURATE LAYOUT, GP,ADES AND ELEVATIONS; SET SLEEVES AND OPENINGS IN AMPLE TIME;.
TAKE PROPER PRECAUTIONS TO PROTECT ALL WORK AND EQUIPMENT FROM DAMAGE.
18.- CLEANOUTS SHALL HAVE PLUGS OF BRASS AND SHALL CONFORM TO FEDERAL SPECIFICATIONS
WW -P -401. CLEANOUTS SHALL BE INSTALLED IN ACCORDANCE WITH THE FBC. (SEE DETAIL).
19.- SIZES AND GRADES OF HORIZONTAL DRAINAGE PIPE:
DIAMETER pITCFt
2" & LESS 1/4" PER FOOT (MIN.)
3" & OVER 1/8" PER FOOT (MIN.)
PRESSURE WITHIN A BUILDING EXCEEDS 80 PSI STATIC.
26.- SHOWERS & SHOWER/TUB COMBINATIONS SHALL BE EQUIPPED W/ CONTROL VALVES OF THE PRESSURE- BALANCE/THERMOSTATIC- MIXING
OR COMBINATION VALVE TYPES WITH A HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016 OR CSA B125. THE HIGH LIMIT STOP SHALL BE
SET TO LIMIT WATER TEMPERATURE TO A MAXIMUM 120' F. IN -LINE THERMOSTATIC VALVES SHALL NOT BE USED PER FBC -R P2708.3.
SHEET TITLE
DATE 04.25.2014
DRAWN BY B.P.
REVIEWED BY C.J.B•
1362
PROJECT N0.
13.-EACH
FIXTURE AND PIECE OF EQUIPMENT SHALL BE PROVIDED WITH SHUT OFF VALVES FOR BOTH HOT AND COLD WATER.
P -1
SHEET