13-872-020FAIN
FO
I
O
TYPE: LOAD CENTER MAIN BUS: 200 AMPS
SERVICE: HOUSE NEW NEUTRAL: 200 AMPS
VOLTAGE: 120/240V, 1 PH, 3 WIRE PANEL "All MAIN: 200 A, M.L.O.
MOUNTING: FLUSH AIC: 22,000
AMPS
AMPS
POLES
TOTAL
V.A.
COND.
WIRE
SERVES
CKT.
CKT.
SERVES
WIRE
COND.
TOTAL
VA.
POLES
AMPS
1
50
2
6000
1
6
RANGE
AHU -2
8
AHU -1
8
3/4
7300
2
40
*
3
4
25
2
4500
1/2
10
W.H. -1
5
6
WASHER
12
1/2
1500
2
20
*
7
8
GARBAGE DISPOSAL
12
1/2
680
2
20
40
2
5200
3/4
8
CU -1
9
10
REFRIGERATOR
12
1/2
1000
1
20
9
11
12
DISHWASHER
12
1/2
1200
1
20
20
1
1600
1/2
12
SMALL APPLIANCE
13
14
DRYER
10
1/2
5000
2
30
14
20
1
1600
1/2
12
SMALL APPLIANCE
16
16
15
1
*
1/2
14
SMOKE DETECTORS
17
18
KITCHEN LTS
14
1/2
*
1
15
*
15
1
*
1/2
14
BEDROOM 2 LTS
19
20
KITCHEN HOOD
12
1/2
800
1
20
1/2
15
1
*
1/2
14
BEDROOM 2 REC
21
22
BEDROOM 4 RECEP.
14
1/2
*
1
15
(1
15
1
*
1/2
14
BEDROOM 3 LTS
23
24
BEDROOM 4 LTS.
14
1/2
*
1
151
SPACE
15
1
*
1/2
14
BEDROOM 3 REC
25
26
FAMILY ROOM LTS
14
1/2
*
1
15
25
15
1
*
1/2
14
BATH 1 LTS
27
28
FAMILY ROOM RECEP.
14
1/2
*
1
15
28
15
1
*
1/2
14
BATH 2 LTS
29
30
DIN /LIV ROOM LTS
14
1/2
*
1
15
FUTURE POOL PUMP
20
1
*
1/2
12
BATH 2 GFI
31
32
DIN /LIV ROOM RECEP.
14
1/2
*
1
15
15
1
*
1/2
14
LIBRARY LTS
33
34
SPACE
6000
2
40
15
1
*
1/2
14
LIBRARY REC
35
36
SPACE
SPACE
37
38
FUTURE POOL LIGHT
12
15
1
*
1/2
14
HALL LTS
37
38
SPACE
SPACE
39
40
SPACE
15
1
*
1/2
14
HALL REC.
39
40
SPACE
41
42
SPACE
20
1
850
1/2
12
WINE COOLER
41
42
SPACE
CONNECTED LOAD: (SEE LOAD CALCULATIONS) FEEDER: SEE RISER
N.C. = NON CONCURRENT LOAD WIRE T.B.S. =TO BE SELECTED FED FROM: SEE RISER
01 INSTALL ARC FAULT INTERRUPTER CIRCUIT BREAKER.
TYPE: LOAD CENTER MAIN BUS: 200 AMPS
SERVICE: HOUSE NEW NEUTRAL: 200 AMPS
VOLTAGE: 120/240V, 1 PH, 3 WIRE PANEL 1113" MAIN: 200 A, M.L.O.
MOUNTING: FLUSH AIC: 22,000
AMPS
POLES
TOTAL
V.A.
COND.
WIRE
SERVES
CKT.
CKT.
SERVES
WIRE
COND.
TOTAL
V.A.
POLES
AMPS
20
1
*
1/2
12
BATH GFI
1
2
AHU -2
8
3/4
7300
2
40
15
1
*
1/2
14
M. BATH LTS
3
4
0
1,500
TO CWP
#
Z200
5
6
POWDER /LAUN. /HALL REC,
14
1/2
*
1
15
15
1
*
1/2
14
M. BEDROOM REC.
7
8
POWDER /LAUN. /HALL LTS
14
1/2
*
1
15
40
2
5200
3/4
8
CU -2
9
10
EXTERIOR RECEP,
12
1/2
*
1
20
11
12
EXTERIOR LTS
14
1/2
*
1
15
15
1
*
1/2
14
M. BEDROOM LTS
13
14
GARAGE LTS
14
1/2
*
1
15
15
1
*
1/2
14
WIC / HALL LTS
15
16
GARAGE DOORS
12
1/2
2000
1
20
15
1
*
1/2
14
DOOR BELL
17
18
SPACE
15
1
*
1/2
14
EXTERIOR REAR LTS,
19
20
SPACE
15
1
*
1/2
14
EXTERIOR TERRACE LTS,
21
22
SPACE
SPACE
23
24
SPACE
SPACE
25
26
SPACE
SPACE
27
28
SPACE
SPACE
29
30
FUTURE POOL PUMP
12
3/4
4500
2
40
SPACE
31
32
SPACE
33
34
FUTURE SPRINKLER PUMP
12
3/4
6000
2
40
SPACE
35
36
SPACE
37
38
FUTURE POOL LIGHT
12
1/2
800
1
20
SPACE
39
40
SPACE
SPACE
41
42
SPACE
CONNECTED LOAD: (SEE LOAD CALCULATIONS) FEEDER: SEE RISER
N.C. = NON CONCURRENT LOAD WIRE T.B.S. =TO BE SELECTED FED FROM: SEE RISER
(DINSTALL ARC FAULT INTERRUPTER CIRCUIT BREAKER.
- � -.
IN 1111, i
NOT TO SCALE
SCROLL TYPE STEEL
HOUSING W/ WHITE BAKED
ENAMEL FINISH
C),
0
ELECTRICAL JUNCTION BOX
POLYSTYRENE GRILLE WHITE
COLOR, ALIGNED AND
TIGHTENED BY SINGLE
CENTER KNOB
CEILING FAN
3 EXHAUST DETAIL (TYP.)_
E -1 NOT TO SCALE
ELECTRICAL NOTES:
1,- CODES: ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E,C, N.F.P.A., N.E.M.A., I.E,E.E„ AND ANY OTHER
APPLICABLE CODES AND STANDARDS.
2.- FIELD CONDITIONS: THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING EXISTING FIELD CONDITIONS BY VISITING THE SITE PRIOR
TO COMMENCING OR BIDDING THE WORK. ANY EXISTING CONDITION FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT
THE WORK SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT / ENGINEER.
3•- DAMAGED EQUIPMENT: THE CONTRACTOR SHALL SATISFACTORILY REPAIR AND /OR REPLACE ANY EQUIPMENT OR ANY PART OF A
STRUCTURE DAMAGED AS A RESULT OF OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH THEIR
PREVIOUS CONDITIONS OR THE ADJACENT AREAS.
4.- APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO DRILLING OR CUTTING ANY STRUCTURAL SUPPORT MEMBERS.
5.- ALL DEVICE BOXES SHALL BE INSTALLED FLUSH. CONDUITS RUNS, RACEWAYS, AND PIPING SHALL BE CONCEALED IN FINISHED
AREAS UNLESS OTHERWISE NOTED.
6.- WIRE SIZE SHALL BE MINIMUM #14 THHN /THWN UNLESS OTHERWISE NOTED ON PLANS.
7.- CONDUCTORS: ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT (METALLIC TYPE) OR RUN IN ROMEX (ALLOWED ONLY
FOR AREAS INSIDE RESIDENTIAL UNITS), IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND
CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250 -122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED,
8.- ALL MATERIAL MUST BE NEW AND III APPROVED.
9.- ALL BRANCH CIRCUITS MUST BE PROPERLY PHASE BALANCED.
10.- CONTRACTOR SHALL SEAL ALL FLOOR OPENINGS WITH A FIRE SEAL, 3M FIRE DAM 150, OR APPROVED EQUAL. CAP ALL
ELECTRICAL AT WALLS TO BE REMOVED.
11. -ALL CABLES SHALL BE RUN WITHOUT SPLICES UNLESS OTHERWISE NOTED.
12.-ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES.
13.-EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD,
14.-WORKMANSHIP: ALL WORK SHALL BE DONE IN A NEAT, PROFESSIONAL, AND WORKMANLIKE MANNER AND PERFORMED BY A
LICENSED ELECTRICAL CONTRACTOR, COMPLETED, AND FULLY OPERATIVE TO THE ACCEPTANCE OF THE ARCHITECT / ENGINEER.
16. -A /C EQUIPMENT WIRING, BREAKER, AND FUSE SIZE, ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DOCUMENTS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER, AND FUSE SIZES, IN ACCORDANCE WITH A/C EQUIPMENT
NAMEPLATE REQUIREMENTS IF DIFFERENT FROM TART SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING
AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE - MENTIONED CHANEGS AT NO EXTRA COST.
16.- COORDINATION: CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL CONTROL
WIRING, RACEWAYS, ALL POWER CONTROLS, AND CIRCUIT WIRING AS SHOWN ON THE AIR CONDITIONING DRAWINGS AND
SPECIFICATIONS,
17.— INTERFERENCE: CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF OTHER TRADES, SO THAT INTERFERENCES WITH
EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL, STRUCTURAL, AND WORK WITH OTHER TRADES WILL BE
AVOIDED.
18. —SMOKE DETECTORS: ALL SMOKE DETECTORS SHALL BE 120V SOURCE W/ BATTERY BACKUP. CONTRACTOR SHALL INTERLOCK ALL
DETECTORS SO THEY WILL SOUND THROUGHOUT THE PREMISES.
19.—PLANS: DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE EQUIPMENT LOCATIONS AND
ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL, PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND
DIMENSIONS. PROVIDE ALL OFFSETS, FITTINGS, AND ACCESORIES REQUIRED FOR A COMPLETE, ACCEPTABLE, WORKING INSTALLATION.
20.— UTILITIES: BEFORE SUBMITTING BID, CONTRACTOR SHALL CHECK WITH ELECTRICAL, TELEPHONE, CABLE TV, AND OTHER UTILITY
COMPANIES SUPPLYING SERVICE TO THIS INSTALLATION TO DETERMINE INSTALLATION STANDARDS AND EQUIPMENT REQUIREMENTS
AND COST TO BE INCLUDED IN THE BID, EXCEPT WHERE UTILITY REQUIREMENTS CHANGE AFTER SUBMITTAL, NO EXTRA PAYMENT
WILL BE MADE TO THE CONTRACTOR FOR SUCH ITEMS, PROVIDE TEMPORARY ELECTRICAL SERVICES FOR ALL TRADES.
21.— SUBMITTALS: PRIOR TO PLACING AN ORDER AND BEFORE INSTALLATION, SUBMIT FOR REVIEW PROPERLY IDENTIFIED AND BOUND,
SHOP DRAWINGS AND MANUFACTURERS LITERATURE GIVING SPECIFICATIONS, DETAILS, COMPLIANCE, UP APPROVAL, MATERIALS,
FINISHES, ACCESORIES, AND INSTALLATION DIRECTIONS WHERE REQUIRED OF THE EQUIPMENT SPECIFIED.
22.— SUBSTITUTIONS: PRODUCTS AND MATERIALS CALLED OUT BY TRADE NAME AND / OR CATALOG NUMBERS ESTABLISH A STANDARD
OF QUALITY, APPEARANCE, PERFORMANCE, AND DIMENSION. CONTRACTOR SHALL BASE HIS PROPOSAL ON THOSE ITEMS AS THEY
SHALL BE CONSIDERED AS A STANDARD BASIS OF BIDDING. REQUEST FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO
THE ARCHITECT / ENGINEER, DEMONSTRATING THAT PRODUCT IS OF COMPARABLE AND BASIC DESIGN, CONSTRUCTION STANDARDS
AND WARRANTIES, DIMENSIONS TO FIT WITHOUT CHANGE, AND DOES NOT CAUSE EXTRA WORK FOR OTHER TRADES. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVING EQUALITY OF SUBSTITUTIONS; ARCHITECT / ENGINEER WILL, UNDER NO CIRCUMSTANCES, BE
REQUIRED TO PROVE SUCH ITEM IS OR IS NOT OF EQUAL QUALITY TO THE SPECIFIED ITEM. CONTRACTOR SHALL PAY FOR
ARCHITECT / ENGINEER EXPENSE INCURRED DUE TO CONTRACTOR'S REQUESTED REVISIONS OR SUBSTITUTIONS.
23.— GUARANTEES: AFTER THE SYSTEM IS INSTALLED, THE CONTRACTOR SHALL CONDUCT AN OPERATIVE TEST FOR APPROVAL AND
ACCEPTANCE BY THE OWNER. ENTIRE ELECTRICAL WORK, INCLUDING PARTS AND LABOR, SHALL BE GUARANTEED FOR A PERIOD OF
ONE) YEAR FROM DATE OF FINAL WRITTEN ACCEPTANCE THEREOF AGAINST DEFECTIVE MATERIALS, CONSTRUCTION, AND
WORK WHERE APPLICABLE, LONGER GUARANTEED FOR CERTAIN COMPONENTS SHALL APPLY AS REQUIRED AND NOT BE
REDUCED IN ANY WAY. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE
REPLACEMENTS AND / OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY.
24. -PER ITS: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES, AND OTHER ITEMS
AS REQUIRED FOR THE INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM AS OUTLINED HEREIN AND SHOWN ON PLANS. PROVIDE
ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILTIY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
25. —ALL LIGHT FIXTURES TO BE SELECTED AND APPROVED BY THE OWNER.
26.— TAMPER — RESISTANT RECEPTACLES SHALL BE PROVIDED FOR 15— AND 20 —AMP RECEPTACLES AS PER NEC 406.11 IN ALL AREAS
OF THE DWELLING UNIT AS SPECIFIED IN NEC 210.52.
LOAD •
4" DIAM. OUTLET W/
y,
VINYL BACKDRAFT
GENERAL LIGHTING., r: - S.F.
OUTSIDE
GARAGE
DAMPER
EXISTING Q.H.
' 3 - #2/0 THW. CU IN 2"
ELEC. SERVICE
3,000
CONDUIT
EXISTING 2 "0 RGC
6,000
ABOVE METER
r
bikYtk
51,300
PANEL PANEL
r
HOTVIATER HEATER
"A"
fr
EXISTING #4 (MIN.) Co
0
1,500
TO CWP
#
Z200
10
DISHWASHER
1,200
AMPS. ELECTRICAL
i
EXISTING 5/8 "0 x10"
a50
PANEL "A" & "B"
851
COPPER CLAD GROUND
680
NEMA 3R 120/240V 10, 3W
DNEN RODS
2,00 r.
FUTURE POOL PUMP
GRADE
8" DIAM. BLADED
FUTUR S r RINKL r s'#
PROPELLER FAN DIRECTLY
FUTURE POOL PUMP
Soo
MOUNTED
- � -.
IN 1111, i
NOT TO SCALE
SCROLL TYPE STEEL
HOUSING W/ WHITE BAKED
ENAMEL FINISH
C),
0
ELECTRICAL JUNCTION BOX
POLYSTYRENE GRILLE WHITE
COLOR, ALIGNED AND
TIGHTENED BY SINGLE
CENTER KNOB
CEILING FAN
3 EXHAUST DETAIL (TYP.)_
E -1 NOT TO SCALE
ELECTRICAL NOTES:
1,- CODES: ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E,C, N.F.P.A., N.E.M.A., I.E,E.E„ AND ANY OTHER
APPLICABLE CODES AND STANDARDS.
2.- FIELD CONDITIONS: THE CONTRACTOR IS RESPONSIBLE FOR EVALUATING EXISTING FIELD CONDITIONS BY VISITING THE SITE PRIOR
TO COMMENCING OR BIDDING THE WORK. ANY EXISTING CONDITION FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT
THE WORK SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT / ENGINEER.
3•- DAMAGED EQUIPMENT: THE CONTRACTOR SHALL SATISFACTORILY REPAIR AND /OR REPLACE ANY EQUIPMENT OR ANY PART OF A
STRUCTURE DAMAGED AS A RESULT OF OF HIS WORK. SURFACES AND FINISHED AREAS SHALL BE RESTORED TO MATCH THEIR
PREVIOUS CONDITIONS OR THE ADJACENT AREAS.
4.- APPROVAL SHALL BE OBTAINED FROM THE ENGINEER PRIOR TO DRILLING OR CUTTING ANY STRUCTURAL SUPPORT MEMBERS.
5.- ALL DEVICE BOXES SHALL BE INSTALLED FLUSH. CONDUITS RUNS, RACEWAYS, AND PIPING SHALL BE CONCEALED IN FINISHED
AREAS UNLESS OTHERWISE NOTED.
6.- WIRE SIZE SHALL BE MINIMUM #14 THHN /THWN UNLESS OTHERWISE NOTED ON PLANS.
7.- CONDUCTORS: ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT (METALLIC TYPE) OR RUN IN ROMEX (ALLOWED ONLY
FOR AREAS INSIDE RESIDENTIAL UNITS), IF PVC SCHEDULE 40 IS USED FOR UNDERGROUND FEEDERS ONLY, AN EQUIPMENT GROUND
CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250 -122 MUST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED,
8.- ALL MATERIAL MUST BE NEW AND III APPROVED.
9.- ALL BRANCH CIRCUITS MUST BE PROPERLY PHASE BALANCED.
10.- CONTRACTOR SHALL SEAL ALL FLOOR OPENINGS WITH A FIRE SEAL, 3M FIRE DAM 150, OR APPROVED EQUAL. CAP ALL
ELECTRICAL AT WALLS TO BE REMOVED.
11. -ALL CABLES SHALL BE RUN WITHOUT SPLICES UNLESS OTHERWISE NOTED.
12.-ALL PULL AND JUNCTION BOXES SHALL BE ACCESSIBLE AT ALL TIMES.
13.-EXACT POINT AND METHODS OF CONNECTION SHALL BE DETERMINED IN FIELD,
14.-WORKMANSHIP: ALL WORK SHALL BE DONE IN A NEAT, PROFESSIONAL, AND WORKMANLIKE MANNER AND PERFORMED BY A
LICENSED ELECTRICAL CONTRACTOR, COMPLETED, AND FULLY OPERATIVE TO THE ACCEPTANCE OF THE ARCHITECT / ENGINEER.
16. -A /C EQUIPMENT WIRING, BREAKER, AND FUSE SIZE, ARE BASED ON A/C EQUIPMENT SPECIFIED ON CONTRACT DOCUMENTS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER, AND FUSE SIZES, IN ACCORDANCE WITH A/C EQUIPMENT
NAMEPLATE REQUIREMENTS IF DIFFERENT FROM TART SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING
AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE - MENTIONED CHANEGS AT NO EXTRA COST.
16.- COORDINATION: CONTRACTOR SHALL COORDINATE ALL HIS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL CONTROL
WIRING, RACEWAYS, ALL POWER CONTROLS, AND CIRCUIT WIRING AS SHOWN ON THE AIR CONDITIONING DRAWINGS AND
SPECIFICATIONS,
17.— INTERFERENCE: CONTRACTOR SHALL COORDINATE HIS WORK WITH THE WORK OF OTHER TRADES, SO THAT INTERFERENCES WITH
EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL, STRUCTURAL, AND WORK WITH OTHER TRADES WILL BE
AVOIDED.
18. —SMOKE DETECTORS: ALL SMOKE DETECTORS SHALL BE 120V SOURCE W/ BATTERY BACKUP. CONTRACTOR SHALL INTERLOCK ALL
DETECTORS SO THEY WILL SOUND THROUGHOUT THE PREMISES.
19.—PLANS: DRAWINGS ARE GENERALLY DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE EQUIPMENT LOCATIONS AND
ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL, PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND
DIMENSIONS. PROVIDE ALL OFFSETS, FITTINGS, AND ACCESORIES REQUIRED FOR A COMPLETE, ACCEPTABLE, WORKING INSTALLATION.
20.— UTILITIES: BEFORE SUBMITTING BID, CONTRACTOR SHALL CHECK WITH ELECTRICAL, TELEPHONE, CABLE TV, AND OTHER UTILITY
COMPANIES SUPPLYING SERVICE TO THIS INSTALLATION TO DETERMINE INSTALLATION STANDARDS AND EQUIPMENT REQUIREMENTS
AND COST TO BE INCLUDED IN THE BID, EXCEPT WHERE UTILITY REQUIREMENTS CHANGE AFTER SUBMITTAL, NO EXTRA PAYMENT
WILL BE MADE TO THE CONTRACTOR FOR SUCH ITEMS, PROVIDE TEMPORARY ELECTRICAL SERVICES FOR ALL TRADES.
21.— SUBMITTALS: PRIOR TO PLACING AN ORDER AND BEFORE INSTALLATION, SUBMIT FOR REVIEW PROPERLY IDENTIFIED AND BOUND,
SHOP DRAWINGS AND MANUFACTURERS LITERATURE GIVING SPECIFICATIONS, DETAILS, COMPLIANCE, UP APPROVAL, MATERIALS,
FINISHES, ACCESORIES, AND INSTALLATION DIRECTIONS WHERE REQUIRED OF THE EQUIPMENT SPECIFIED.
22.— SUBSTITUTIONS: PRODUCTS AND MATERIALS CALLED OUT BY TRADE NAME AND / OR CATALOG NUMBERS ESTABLISH A STANDARD
OF QUALITY, APPEARANCE, PERFORMANCE, AND DIMENSION. CONTRACTOR SHALL BASE HIS PROPOSAL ON THOSE ITEMS AS THEY
SHALL BE CONSIDERED AS A STANDARD BASIS OF BIDDING. REQUEST FOR SUBSTITUTIONS SHALL BE SUBMITTED IN WRITING TO
THE ARCHITECT / ENGINEER, DEMONSTRATING THAT PRODUCT IS OF COMPARABLE AND BASIC DESIGN, CONSTRUCTION STANDARDS
AND WARRANTIES, DIMENSIONS TO FIT WITHOUT CHANGE, AND DOES NOT CAUSE EXTRA WORK FOR OTHER TRADES. CONTRACTOR
SHALL BE RESPONSIBLE FOR PROVING EQUALITY OF SUBSTITUTIONS; ARCHITECT / ENGINEER WILL, UNDER NO CIRCUMSTANCES, BE
REQUIRED TO PROVE SUCH ITEM IS OR IS NOT OF EQUAL QUALITY TO THE SPECIFIED ITEM. CONTRACTOR SHALL PAY FOR
ARCHITECT / ENGINEER EXPENSE INCURRED DUE TO CONTRACTOR'S REQUESTED REVISIONS OR SUBSTITUTIONS.
23.— GUARANTEES: AFTER THE SYSTEM IS INSTALLED, THE CONTRACTOR SHALL CONDUCT AN OPERATIVE TEST FOR APPROVAL AND
ACCEPTANCE BY THE OWNER. ENTIRE ELECTRICAL WORK, INCLUDING PARTS AND LABOR, SHALL BE GUARANTEED FOR A PERIOD OF
ONE) YEAR FROM DATE OF FINAL WRITTEN ACCEPTANCE THEREOF AGAINST DEFECTIVE MATERIALS, CONSTRUCTION, AND
WORK WHERE APPLICABLE, LONGER GUARANTEED FOR CERTAIN COMPONENTS SHALL APPLY AS REQUIRED AND NOT BE
REDUCED IN ANY WAY. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE
REPLACEMENTS AND / OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY.
24. -PER ITS: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES, AND OTHER ITEMS
AS REQUIRED FOR THE INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM AS OUTLINED HEREIN AND SHOWN ON PLANS. PROVIDE
ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILTIY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
25. —ALL LIGHT FIXTURES TO BE SELECTED AND APPROVED BY THE OWNER.
26.— TAMPER — RESISTANT RECEPTACLES SHALL BE PROVIDED FOR 15— AND 20 —AMP RECEPTACLES AS PER NEC 406.11 IN ALL AREAS
OF THE DWELLING UNIT AS SPECIFIED IN NEC 210.52.
LOAD •
y,
GENERAL LIGHTING., r: - S.F.
4227
..
SMAL- APPLIANCE LOAD
3,000
RANGE
6,000
►s
r
bikYtk
51,300
r
HOTVIATER HEATER
fr
WASHER
0
1,500
' • `'
#
10
DISHWASHER
1,200
i
COOLER WINE
a50
851
"GARBkGE DISPOSAL
680
GARAGE DOORS
2,00 r.
FUTURE POOL PUMP
4,500
4 50LIM
FUTUR S r RINKL r s'#
6,000
FUTURE POOL PUMP
Soo
8 0 Ir
CONNECTED • ' •
2 i
r
000 @ 100%
Ir Its
lo,000
10,00
r i
7,503
81n
A/C LOAD 100%
7,300
7,30;
14600
TOTAL
24,803
2),1110
38,91
49$1, 8VV 74 Court
Miami, FL 33155
786.615.2943
786.6:15.294 ; Fay Ty µ
ebravo at~ urvanx.co-on
AA26002656
I132e(IC1472
Carlos J. Bravo, R.A. AR17584
THE DESIGNS AND DRAWINGS PRESENT HEREIN ARE THE SOLE
PROPERTY
DUPLICATED WktTFIOUt SPECIFIC D WRITTEN PERMISSION OFF
URY4,9t, INC.
SEAL
IN AiY PROFESSIONAL JUDCEiAENT,AND TO THE BEST CF
SPECIFICATIONS CONTAINED HERON THE OOI,I PLANS WITH ALL
APPLICABLE BUILDING CODES.
Consultant:
Addition /Renovation
for
Salcines / Gonzalez
Residence
7800 SW 58 Ct.
South Miami, FL 33143
Owner:
Jacqueline A. Salcines &
Rodolfo R. Gonzalez
7800 SW 58 Ct.
South Miami, FL 33143
(305) 669 -5236
Permit Set
REVISIONS
I Nol DATE I DESCRIPTION
ELECTRICAL PANELS /
NOTES / ELECTRICAL
DETAILS AND RISER
SHEET TITLE
DATE 04.25.2014
DRAWN BY B.P.
REVIEWED BY C.J.B.
E -2
SHEET
1362
PROJECT No.