11-32-0163/4" DEEP x 1/8"--\ POWERED ACTUATED PINS. FLEX . DUCT . UP 29 " NTH ORIG" DEEP. jr RIGID DUCT UP TO 29" WITH OR 16" DEEP. .— x 28 GA G.M. STRIP AT SUPPORT. 1" WIDE x 22 GA STRAP ® 8 " -0 0/C PINS. 0 MUL- A 28 GA G.M. STRIP AT SUPPORT. DUCT HANGER DETAIL N.T.S. CONDENSING UNIT 2 \ 7x2 \ "x1 /4 "GALV ANGLE IYP. OF 4 (TWO PER SIDE) EXISTING — METAL FRAME 1/2- MECH. EXPANSION 4 GALVANIZED ANCHOR BOLTS MINIMUM EMBEDMENT 4" NOTE: 1— SEAL ENTRANCE OF REFRIGERANT LINES INTO PVC PIPE W MPERMEABLE, RESILIENT MATERIAL (SEE DETAIL). 2— An anchor bolt w/ minimum 500 Ibs pull out resistance shall secure the AC condenser unit from within the unit through the conc. slab on which the unit rests.(anti —theft bolt). (mdc ch 8 —c sec. 8c -5) I'M 40 � ai - . 71 At ATTIC SPACE. COIL /NEAT SECTION FAN SECTION FILTER ACCESS /air duct CEILING WALLS F. LINES PROVIDE CAP OFF FOR VENT J12" MIN. PREFAB MTL. FRAME F.F. A/C CLOSET INSTALLATION N.T.S. NOTE: 1. PROVIDE SECONDARY DRAIN PAN WITH AN APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH DEVICE THAT WILL CONTROL OVERFLOW BY AUTOMATICALY SHUTTING DOWN THE AHU's. FOR SWITCH MANUF. AND MODEL NO PLEASE REFER TO PLUMBING DRAWINGS. 2. PROVIDE MIN. 4" CLEARANCE ALL AROUND AC UNIT INSTALLED INSIDE AC CLOSET AS PER FMC 603.1.4 FLEXIBLE DUCT VENT THROUGH — OVERHANG EAVE elbow w /back damper & grille FAN BOX INSIDE BATHROOM EXHAUST VENT DETAIL - THROUGH OVERHANG N.T.S. NOTE SHEET METAL CONNECTIONS MUST BE MADE USING GLASS FABRIC AND MASTIC (GFM) EXCEPTION: WHEN CONSTRUCTION PRESSURE CLASS IS 1" W.G. OR LESS AND SHEET METAL SURFACES ARE CLEANED CAREFULLY UL LISTED PRESSURE — SENSITIVE ALUMINUM TAPE MAY BE USED. ALL CONNECTIONS OF FIBROUS GLASS DUCT TO EQUIPMENT AND METAL DUCT MUST BE MECHANICALLY ATTACHED 12' (MAX.) ON CENTERS. FLANGE GFM CLOSURE #10 X 1 1/4" SHEET METAL SCREWS 12" (MAX.) O.C. MIN- 2 PER SIDE FIBROUS GLASS DUCT L22 GAUGE SHEET METAL 1 "X1 "X1" CHANNEL FASTENED TO METAL GE SHEET METAL AND EQUIPMENT CONNECTIONS DETAILS NTS DIRECTION OF AIR FLT "' -CO ]-PNa MUM COLTRAIN AND JONES ARCHITECTS, PA AA 26000922 TELEPHONE (305 285 -6723 I r�5) FAX 285-6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 DESIGN I CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS I CAD PRODUCTION CONSULTANT/ NOTES APPROVALS /REVISIONS DATE 1/8- STAINLESS STEEL WIRE WRAP ARROUND CONDENSING UNIT ( Dade county ordinance 86 -5). POWER & CONTROL /— LOCATION SUCTION LINE W/ 1" ARMAFLEX INSULATION & VAPOR BARRIER 1/2" BOLTS AND NUTS C.U. MOUNTING DETAIL N.T.S. LIQUID LINE W/ 0 INSULATION NOTES: 1.INSTALL CONDENSING UNIT EITHER ABOVE THE BASE FLOOD ELEVATION LEVEL OR PROTECTED SO AS TO PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE CONDENSING UNIT DURING FLOODS UP TO THE BASE FLOOD ELEVATION. 2.INSTALLATION MUST MEET MINIMUM OF 146 MPH WIND LOADING. MIN. REQUIREMENTS ARE HEREBY INDICATED HOWEVER BASED ON ACTUAL EQUIPMENT INSTALLED EPA (EFFECTIVE PROJECTED AREA) ADDITIONAL SECURING SHALL BE PROVIDED 4 t •• S� � �_�� rG GUIROLA & ASSOCIATES P.A_ CONSULTING ENGINEERS P.E. No 57468 '. David Guirola Electrical Engineer 1150 NW 72nd AVE. 5 -451 MIAMI, FLORIDA 33126 P.H: (305) 513 -9665 CA 00009112 EMAIL: GUIRO 5@AOL.COM SEAL: * AR 0015755 o * 0 o Mark A Coltrain AR 0013380 Richard K. Jones, AIA AR 0015755 SHEET TITLE: HVAC DETAILS Job No. Drawn By: Date Plotted: Scale: (VARIES — SEE DRAWING) Drawing No. M -31 HANGER V (n TO STRUCT. z O DUCT 45 Uj W/4 (4-MIN.) Q wall or concrete ❑ SPEED W V ` sleeve CEILING FAN. ® CONTROL z O `" j" � r e /air duct wall cap w/ back draft damper and bird screen BRANCH DUCT z 0 co M tape and sealer note: bird screen must be avoid for dryer wall cap CEILING GRILLE ,1� JOIST n J all around silicone caulk all around BRANCH DUCT CONNECTION 0 - TOILET EXHAUST FAN DETAIL N.T.S. L11 - WALL CAP MOUNTING DETAIL N.T.S. W3:0 w 0 N.T.S. tL �-- z d' = Q z �O 0 0 Q 1/8- STAINLESS STEEL WIRE WRAP ARROUND CONDENSING UNIT ( Dade county ordinance 86 -5). POWER & CONTROL /— LOCATION SUCTION LINE W/ 1" ARMAFLEX INSULATION & VAPOR BARRIER 1/2" BOLTS AND NUTS C.U. MOUNTING DETAIL N.T.S. LIQUID LINE W/ 0 INSULATION NOTES: 1.INSTALL CONDENSING UNIT EITHER ABOVE THE BASE FLOOD ELEVATION LEVEL OR PROTECTED SO AS TO PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE CONDENSING UNIT DURING FLOODS UP TO THE BASE FLOOD ELEVATION. 2.INSTALLATION MUST MEET MINIMUM OF 146 MPH WIND LOADING. MIN. REQUIREMENTS ARE HEREBY INDICATED HOWEVER BASED ON ACTUAL EQUIPMENT INSTALLED EPA (EFFECTIVE PROJECTED AREA) ADDITIONAL SECURING SHALL BE PROVIDED 4 t •• S� � �_�� rG GUIROLA & ASSOCIATES P.A_ CONSULTING ENGINEERS P.E. No 57468 '. David Guirola Electrical Engineer 1150 NW 72nd AVE. 5 -451 MIAMI, FLORIDA 33126 P.H: (305) 513 -9665 CA 00009112 EMAIL: GUIRO 5@AOL.COM SEAL: * AR 0015755 o * 0 o Mark A Coltrain AR 0013380 Richard K. Jones, AIA AR 0015755 SHEET TITLE: HVAC DETAILS Job No. Drawn By: Date Plotted: Scale: (VARIES — SEE DRAWING) Drawing No. M -31