11-32-014AIR HANDLING UNIT SCHEDULE DESIGNATION AHU -1 A MANUFACTURER carrier MANUFACTURER MODEL NO. FE4ANB0061`00 TITUS TOTAL AIR CFMI 2000 272 FL E.S.P. IN OF W.G. 0.6 ALL ALUM_ RPM - FRAME TYPE H.P. F.L.A. 3/4 - 6.8 SURFACE AVAILABLE SERVICE 208-230/1/60 SIDE WALL OUTSIDE AIR (CFM) - INFILTRATION - - -- ADJUSTABLE mca mo am (W/O HEATER - -- SONES TOTAL COOLING - BTUH * 56,430 DEFLECTION TOTAL COOLING - SENSIBLE BTUH 51,090 SUPPLY TOTAL HEATING - BTUH 19,240 SEE DRAWINGS ELECTRIC HEATER TOTAL KW 10.0 OPPOSED BLADE DAMPERS ELECTRIC HEATER NO STEPS 1 SEE NOTE 4 DIMENSIONS W H INS. 25 X 22 X 30 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED. WEIGHT (LBS) 210 THAT ARE NOT PROVIDED WITH AN ACCESSIBLE MANUAL VOLUME DAMPER SHALL BE LIQUID IN. OD 3/8 INTERLOCK SUCTION IN OD 1 1/8 NEW AND EXISTING work. refrigerant r -41 Do &P, filter merv-8 CEILING DIFFUSER REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL (TRANE,RHEEM,RUUD OR YORK) ( *) ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF: SUMMER: 80 F DRY BULB / 67 F WET BULB WINTER: 70 F DRY BULB EXHAUST VENTS AND DUCT NOTES: 1. CLOTHES DRYER EXHAUST DUCT SHALL "NOT" BE SCREENED. 2. CLOTHES DRYERS EXHAUST DUCTS (OR VENTS) SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MIN. 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT. AIR COOLED CONDENSING UNIT SCHEDULE DESIGNATION CU -1 A MANUFACTURER carrier MANUFACTURER MODEL NO. 24APA76OA003 TITUS AVAILABLE SERVICE 208/230-1-60 272 FL COMPRESSOR TYPE 2 STAGE - SCROLL ALL ALUM_ NO. OF COMPRESSORS 1 FRAME TYPE COMPRESSORS Rla -LrA EACH 23.0 118 SURFACE CONDENSER COIL AREA - SQ. FT. 30.18 SIDE WALL NO. OF CONDENSER FANS 1 ADJUSTABLE CONDENSER AIR (CFM) 4,450 SONES FAN H.P. FLA EACH 1/4 h 1.3 am DEFLECTION A.R.I. NOISE RATING - DB 80 SUPPLY TOTAL COOLING - BTUH * 56,430 SEE DRAWINGS TOTAL HEATING - BTUH * 19,240 OPPOSED BLADE DAMPERS S.E.E.R. W MATCHED AHU 17.0 SEE NOTE 4 C.O.P. W MATCHED AHU N/A 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED. CONDENSING UNIT MCA AMPS 58.5 THAT ARE NOT PROVIDED WITH AN ACCESSIBLE MANUAL VOLUME DAMPER SHALL BE CONDENSING UNIT MAX. FUSE OR CKT. BREAKER AMPS 60.0 INTERLOCK DIMENSIONS W H INS. 41 X 36 X 46 NEW AND EXISTING work. WEIGHT (LBS) 375 &P, LIQUID IN. OD 3/8 CEILING DIFFUSER SUCTION IN OD 1 1/8 CU refrigerant r -410a REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL ( TRANE, RHEEM, RUUD OR YORK) 2. PROVIDE TIME GUARD 11, START CAPACITOR AND RELAY, LIQUID LINE FILTER DRYER & SOLENOID VALVE, 24 V CONTROL TRANSFORMER & THERMOSTAT WITH SYSTEM 'OFF- HEAT -AUTO- COOL" AND FAN "ON -AUTO" S/S ( *) ARI RATINGS BASED ON OUTDOOR TEMPERATURES OF- SUMMER: 95° F DRY BULB WINTER: 44° F DRY BULB () MINIMUM VALUE TO MEET ENERGY CODE AIR DISTRIBUTION SCHEDULE DESIGNATION A B C MANUFACTURER TITUS TITUS TITUS MODEL AND 250 AA 272 FL 3 FL CATALOG NO. ALL ALUM_ ALL ALUM. ALL ALUM. FRAME TYPE SURFACE SURFACE SURFACE TOTAL AIR CFM CEILING SIDE WALL CEILING & WALL DEVICE TYPE ADJUSTABLE DOUBLE SINGLE SONES MULTI- PATTERN DEFLECTION DEFLECTION FUNCTION SUPPLY SUPPLY RETURN & TRANS. PATTERN SEE DRAWINGS N/A N/A OPPOSED BLADE DAMPERS SEE NOTE 4 SEE NOTE 4 SEE NOTE 4 REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITED FOR APPROVAL 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETED. 3. UNLESS OTHERWISE NOTED ALL AIR DEVICES FINISHES SHALL BE BAKED OFF -WHITE 4. SUPPLY,RETURN OR EXHAUST OUTLETS SERVED BY AN INDIVIDUAL DUCT BRANCH THAT ARE NOT PROVIDED WITH AN ACCESSIBLE MANUAL VOLUME DAMPER SHALL BE SUPPLIED WITH INTEGRAL 0.8.D. FAN SCHEDULE AC LEGEND FAN DESIGNATION EF -1 EF -2 DUCT TO MATCH NECK SIZE TYP. AREA SERVED M.BATH BATH DUCT TO MATCH NECK SIZE TYP. LOCATION CEILING CEILING DUCT: FIRST FIGURE IS SIDE shown. MANUFACTURER brown NUTONE existing outside air ductwork MODEL NO. S90 689 W/REMOTE & TEST SWITCH TOTAL AIR CFM 90 60 ALL ELBOWS MUST BE PROVIDED WITH E.S.P. INCHES OF WATER 0.125 0.125 MANUAL VOLUME DAMPER SONES 1.5 3.5 FLEXIBLE DUCT, FLEXIBLE RPM - - - -- ----- 3: H.P. (A =AMP - W--WATTS) 0.5 a 1.1 a AIR FLOW DIRECTION ( ARROWS DENOTE VOLT -PH -HZ 120 7-1 -60 120 -1 -60 RETURN OR EXHAUST, SEE PLANS. DRIVE DIRECT DIRECT WALL MOUNTED SIDE REGISTER. BACKDRAFT DAMPER YES YES EXHAUST FAN INTERLOCK ILIGHT SWITCH LIGHT SWITCH NEW AND EXISTING work. REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL_ 2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQUIPPED WITH SAFETY DISCONNECT SWITCH. HVAC DESIGN REQUIRES: AC LEGEND NO 24X24 CD -(SEE SCHEDULE) e DUCT TO MATCH NECK SIZE TYP. �y CEILING GRILLE SEE SIZE SCHEDULE X DUCT TO MATCH NECK SIZE TYP. Q RETURN AIR GRILLE -(SEE SCHEDULE) FIRE RATED ENCLOSURE DUCT: FIRST FIGURE IS SIDE shown. 20 X 10 sizeS are inside dimension. existing outside air ductwork FIRE STOPPING DUCT MTD. SMOKE DETECTOR 0 AD W/REMOTE & TEST SWITCH Sp (PROVIDE ACCESS DOOR) �C ALL ELBOWS MUST BE PROVIDED WITH (-� TURNING VANES J MANUAL VOLUME DAMPER T THERMOSTAT FC FLEXIBLE DUCT, FLEXIBLE CONNECTION (FC) U.C. 3: (--�� UNDERCUT DOOR U) AIR FLOW DIRECTION ( ARROWS DENOTE -� 1 WAY, 2 WAY, ETC., SEE PLANS -'�-� RETURN OR EXHAUST, SEE PLANS. � WALL MOUNTED SIDE REGISTER. Q LTJ EXHAUST FAN POINT OF CONNECTION between NEW AND EXISTING work. O.AL OUTSIDE AIR INTAKE &P, SIDE REGISTER CD CEILING DIFFUSER AC AIR CONDITIONING UNIT CU CONDENSING UNIT HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR e X FIRE DAMPERS X SMOKE DAMPERS X FIRE RATED ENCLOSURE X FIRE RATED ROOF FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL U X TYPE OF DIFFUSER A 11W DIRECTION OF FLOW 6x6 15 O SIZE OF DIFFUSER OF CFM AIR OUTLET TAG N.T_S. HVAC GENERAL NOTES: 1. THE CONTRACTOR SHALL FURNISH ALLLABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE REVISIONS TO NEW HVAC SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE 2007, ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES AND THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS: A) ANS B-9.1 MECHANICAL REFRIGERATION, B) NFPA PAMPHLETS 90A, 90B AND 91, C) SMACNA, D) ASHRAE, E) OSHA AND THE STANDARD OF CONSTRUCTION ESTABLISHED BY THE EXISTING INSTALLATION. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. UPON FINAL ACCEPTANCE, A CERTIFICATE FROM THE LOCAL INSPECTION AUTHORITY SHALL BE FURNISHED TO THE OWNER 3. THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, CONDUITS, ETC_, AND /OR ANY CONDITION THAT MAY AFFECT HIS WORK. ALL NECESSARY RE- ROUTING, RE- LOCATING AND /OR REMOVAL OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC., SHALL BE INCLUDED IN THE SCOPE OF WORK. ALL MATERIALS USED MUST BE EQUAL TO EXISTING SO INTEGRITY OF THE INSTALLATION IS NOT CHANGED. 4. ALL.MATERIAL AND EQUIPMENTS SHALL BE NEW, OF U.S. MANUFACTURER AND OF GOOD QUALITY OF RESPECTIVE KIND AND GRADE, AND MUST BE FURNISHED SO AS TO PREVENT ANY DELAY IN THE PROGRESS OF THE WORK. ALL WORK THROUGHOUT SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SUFFICIENT NUMBER OF SKILLED WORKMEN. 5. CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES, SPECIALLY WITH THE EXISTING LOCATION OF STRUCTURAL MEMBERS. 6. NEW THERMOSTATS SHALL BE COMBINATION COOLING/HEATING, WITH SYSTEM "COOL- AUTO -HEAT -OFF" AND FAN "ON- AUTO" SELECTOR SWITCHES. USE HONEYWELL OR APPROVED EQUAL. 7. CONTRACTOR SHALL BE RESPONSIBLE TO TEST & BALANCE THE HVAC SYSTEM AS PER ASSOCIATED AIR BALANCE COUNCIL STANDARDS. 8. CONTRACTOR SHALL PRINT UP INSTRUCTIONS FOR OWNER'S OPERATION OF SYSTEM, STATING THE ITEMS COVERED BY HIS GUARANTEE AND THE EQUIPMENT MANUFACTURER'S GUARANTEE. 9. AIR CONDITIONING DUCTWORK SHALL BE ONE INCH STANDARD DUTY, FOIL REINFORCE FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER, KNAUF TYPE 475 DUCTBOARD -M- WITH 1.5 INCH THICK AND AN INSTALLED R -VALUE OF 6.0 OR APPROVED EQUIVALENT, INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL OUTSIDE AIR VENTILATION AND EXHAUST DUCTWORK SHALL BE CODE GAGE GALVANIZED SHEET METAL DUCT SIZES SHOWN ARE NET FREE AREA. PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL ELBOWS. 10. CONTRACTOR SHALL SHALL SUBMIT SHOP DRAWINGS TO THE ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUTS PRIOR TO INSTALLATION. 11. THE WORK INCLUDES PROVIDING THAT HVAC SYSTEMS, INCLUDING DUCTWORK, DIFFUSERS AND GRILLES, CONTROLS AND EQUIPMENT NECESSARY FOR A COMPLETE FUNCTIONING SYSTEM. HVAC SYSTEM INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: SUPPLY, RETURN AND EXHAUST DUCTWORK SYSTEMS WITH GRILLES, DIFFUSERS FILTERS ANDDAMPERS. 12. TEMPERATURE CONTROL SYSTEM INCLUDING LOW VOLTAGE WIRING AND CONDUIT TRANSDUCERS, ACTUATORS CONTROLLER. 13. WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT. 14. DRAWING FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT AND EQUIPMENT REQUIRED. THE DRAWING SHALL NOT BE SCALED FOR EXACT MEASUREMENTS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTION AND INSTALLATION REQUIREMENTS AS REQUIRED. FURNISH AND INSTALL ALL DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS AND MATERIALS NECESSARY TO FACILITATE THE SYSTEM FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT INDICATED. 15. FLEXIBLE CONNECTION: WHERE REQUIRED PROVIDE U.L LABELED NEOPRENE COATED FIBERGLASS FABRIC DUCT CONNECTORS. 16. DUCT FINISHES AND SEALERS SHALL HAVE A SMOKE DEVELOPED RATING OF LESS THAN 50 AND FLAME SPREAD OF 50 OR LESS. 17. REFRIGERANT PIP INSULATION 1" FOAMED PLASTIC INSULATION SHALL BE PROVIDED FOR SUCTION LINES, WITH APPROVED PROTECTIVE FINISH WHEN EXPOSED TO WEATHER. FIRE RATING NOT TO EXCEED 25 FOR FLAME SPREAD AND 50 FOR FUEL CONTRIBUTED AND SMOKE DEVELOPED MANUFACTURER ARMAFLEX OR APPROVED EQUAL 18. REFRIGERANT PIPING SHALL BE COPPER, TYPE L HARD DRAWN (ASTM -B -88) WITH WROUGHT COPPER, SOLDER JOINT TYPE FITTINGS. USE 9515 SOLDER. REFRIGERANT PIPING SHALL BE SIZED IN ACCORDANCE WITH EQUIVALENT PIPE LENGTH FOR PRESSURE DROP EQUIVALENT TO ONE DEGREE FAHRENHEIT. 1" FOAMED PLASTIC INSULATION SHALL BE PROVIDED FOR SUCTION LINES, WITH APPROVED PROTECTIVE FINISH WHEN EXPOSED TO WEATHER. FILTER/DRYER AND SIGHT GLASS SHALL BE PROVIDED AT LIQUID LINES. 19. THE CONTRACTOR IS TO VERIFY THE REMOVAL OF ANY PIECE OF EQUIPMENT PIPING OR CONDUIT WITH THE LANDLORD PRIOR TO BEGINNING ANY WORK. 20. THE CONTRACTOR IS TO VERIFY EXISTING, AND ANY EXISTING TO BE REUSED EQUIPMENT WITH LANDLORD. e r GUIROLA & ASSOCIATES P.A. CONSULTING ENGINEERS 41� CA 00009112 P.E. No 57468 David Guirola Electrical Engineer 1150 NW 72nd AVE, S-451 MIAMI, FLORIDA 33126 PH (305) 513 -9665 EMAIL GUIRO 5@AOLCOM COITRAIN :JQNMEAS ^ - - - /ARCB l t1CTS hffAhff COLTRAIN AND JONES ARCHITECTS, PA AA 26000922 TELEEPHONE (305) 295.6723 I FAX (305) 285-6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 DESIGN I CONSTRUCTION. ADMINISTRATION BUILDING INSPECTIONS I CAD PRODUCTION CONSULTANT/ NOTES APPROVALS /REVISIONS DATE SEAL W U Z W D C/1 W M H U) Z e O_ o v' Owe GUIROLA & ASSOCIATES P.A. CONSULTING ENGINEERS 41� CA 00009112 P.E. No 57468 David Guirola Electrical Engineer 1150 NW 72nd AVE, S-451 MIAMI, FLORIDA 33126 PH (305) 513 -9665 EMAIL GUIRO 5@AOLCOM COITRAIN :JQNMEAS ^ - - - /ARCB l t1CTS hffAhff COLTRAIN AND JONES ARCHITECTS, PA AA 26000922 TELEEPHONE (305) 295.6723 I FAX (305) 285-6722 535 SW 8 ST. SUITE 100 MIAMI, FL 33130 DESIGN I CONSTRUCTION. ADMINISTRATION BUILDING INSPECTIONS I CAD PRODUCTION CONSULTANT/ NOTES APPROVALS /REVISIONS DATE SEAL W U Z W D C/1 W M H U) Z O_ Owe Z U cy) LLl Q M J Q IL C) OCR 3: LLB U) LL Z � � Q Z� O 0 Q AR 0015755 a * o O o o Mark A Coltrain AR 0013380 Richard K. Jones, AIA AR 0015755 SHEET TITLE: _EGEND, GENERAL NOTES AND SCHEDULES Job No. Drawing No. Drawn By: Date Plotted: Scale: (VARIES - SEE DRAWING) M -1