Loading...
11-32-002GENERAL NOTES 1. THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO EXAMINE THE CONTRACT DOCUMENTS AND FAMILIARIZE HIMSELF WITH THE NATURE AND EXTENT OF THE WORK, ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE, AND EQUIPMENT, MATERIALS AND LABOR REQUIRED TO PERFORM THE WORK. 2. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES. HE IS TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS, LIGHT VARIATION OF ROUTING AND OR CONSTRUCTION SHOULD BE ANTICIPATED BY THE CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. 3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY CITY, COUNTY AND STATE LICENSES PRIOR TO COMMENCING CONSTRUCTION. IF SPECIAL PERMITS ARE REQUIRED FOR ANY OF THE WORK, THEY SHALL BE OBTAINED AND EXHIBITED. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH THE LAWS, ORDINANCES, CODES, AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN AND SPECIFIED. 4. ALL ELECTRICAL WORK TO BE PERFORMED BY A STATE LICENSED ELECTRICAL CONTRACTOR. ALL ELECTRICAL WORK TO BE REMOVED, INCLUDING ALL WIRES AND FEEDS, SHALL BE DISCONNECTED FROM CORRESPONDING ELECTRICAL PANEL OR JUNCTION BOX. 5. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES BY CONTRACTOR AND ALL AREAS SHALL BE LEFT IN A BROOM CLEAN CONDITION AT ALL TIMES. ANY DAMAGE TO EXISTING BUILDING EXTERIOR IS THE RESPONSIBILITY OF THE CONTRACTOR TO RESTORE TO ORIGINAL CONDITION. 6. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES, AND BE RESPONSIBLE FOR THE SECURITY OF THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL ITS COMPLETION. CONTRACTOR AND SUBCONTRACTORS SHALL CARRY WORKMAN'S COMP. INSURANCE AS WELL AS GENERAL LIABILITY INSURANCE AND SHALL MAINTAIN SUCH INSURANCE THROUGH COMPLETION OF JOB. SUBMIT PROOF OF INSURANCE TO OWNER. 7. GENERAL CONTRACTOR SHALL EXERCISE CARE DURING DEMOLITION AND REMOVAL TO ASSURE THAT ITEMS SCHEDULED FOR DEMOLITION ARE PROPERLY REMOVED AND ITEMS TO REMAIN ARE PROTECTED FROM DAMAGE. 8. ALL FINISHES AND SURFACES WHICH ARE DAMAGED DURING DEMOLITION SHALL BE REPAIRED AND OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER. 9. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY DEMOLITION WORK. 10. THE CONTRACTOR SHALL FURNISH ALL MATERIAL, EQUIPMENT, LABOR AND OTHER FACILITIES NECESSARY FOR THE EXECUTION OF THE WORK. GENERAL CONTRACTOR IS TO REVIEW THE EXISTING SPACE AND FAMILIARIZE THEMSELVES WITH ALL EXISTING CONDITIONS AND FINISHES. 11. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ERRORS, INCONSISTENCIES OR OMISSIONS HE MAY DISCOVER ON THESE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERROR AFTER THE START OF THE CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT. THE MEANS OF CORRECTING ANY ERROR SHALL BE APPROVED BY THE ARCHITECT. 12. THE CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PERTINENT TO HIS CONTRACT PRIOR TO CONSTRUCTION. 13. THE CONTRACTOR SHALL PROTECT ALL EXISTING CONCRETE CURBS AND ASPHALT FROM DAMAGE FROM CONSTRUCTION AND HEAVY EQUIPTMENT, 14. ALL LANDSCAPED AREAS AFFECTED BY CONSTRUCTION IS TO BE RESTORED WHEN WORK IS COMPLETED. 26.00' ATTIC VENT CALCULATION HOUSE CEILING AREA: 1,897 S.F. 273,168 S.I. / 150 = 1,821 S.I. VENT AREA REQUIRED: 1,821 S.I. VENT SIZE: 16" x 4" = 64 S.I. REQUIRED VENTS: 1,821 S.I. / 64 S.I. = 29 VENTS 62.00' E NOTES FOR G.C. 1. VERIFY ALL DIMENSIONS ON DRAWINGS AND CONDITIONS AT 3. EVEN THOUGH THE DRAWINGS ARE TO SCALE, DO NOT 6. WHEN A DETAIL, DIMENSION, OR REFERENCE IS, INDICATED JOB SITE PRIOR TO COMMENCING WORK. NOTIFY ARCHITECT OR SCALE ANY OF THEM, FOLLOW THE DIMENSIONS, ELEVATIONS AS 'TYPICAL', IT APPLIES TO ALL SIMILAR SITUATIONS, WHETHER OWNER REPRESENTATIVE OF ANY DISCREPANCIES AND SECURE AND SPECIFICATIONS SHOWN ON THE PLANS. INDICATED OR NOT. AN INTERPRETATION OR DECISION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND 7. SECTIONS OR DETAILS SHOWN, APPLY TO ALL SIMILAR LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE SITUATIONS, WHETHER INDICATED OR NOT AND UNLESS 2. G.C. TO EXAMINE AND COORDINATE STRUCTURAL, EQUIPMENT AND MATERIALS UNDER CONTRACT AND PROVIDE OTHERWISE NOTED. MECHANICAL, ELECTRICAL & PLUMBING PLANS FOR READY ACCESSIBILITY TO DAMPERS, VALVES AND OTHER VERIFICATION OF LOCATIONS AND DIMENSIONS OF ALL PROJECT APPARATUS, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE 8. BATHROOM FIXTURES TO BE SELECTED AND PROVIDED BY REQUIREMENTS. REPORT ANY DISCREPANCIES TO THE REACHED FOR MAINTENANCE AND OPERATIONS. PARTIES INDENTIFIED WITHIN. G.C. TO COORDINATE INSTALLATION ARCHITECT PRIOR TO PROCEEDING WITH WORK IN AREA OF WITH PARTIES DESCRIBED WITHIN. CONFLICT. PROPOSE AND COORDINATE SOLUTION FOR AREA OF 5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO CONFLICT. AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION 9. ALL CLOSETS AND BATHROOMS ARE TO RECEIVE 2x6 AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND BACKING AS NECESSARY TO SUPPORT ALL WALL MOUNTED STANDARDS. ITEMS. PROVIDE 1/2" PLYWOOD BEHIND DRYWALL AT ALL SHELF WALLS IN CLOSETS. Y U O m t � I N I) 00 6 N of EXISTING POOL 1 I ( I NEW PORCH � N NEW 900 GAL. SEPTIC TANK 1 7' -6„ 7' -619 REQ. REQ. SETBACK 1 SETBACK I 50' -8" 16 -110" do 1 NEW ONE-STORY 1 M I -- ''"-- � - -_ --� ADDI ION ( 1 rrTl, -r -rT„ Ew 500 SO. FT F. ELE .12.50 r I I ( I I I I I I I I ' I m m i i i 1 i i i i i i l IN FIELD I/ 1 ; o I I I I 1 1 1 1 I l , 5 2 „ I i1i i i i I i I 2 N I 1i i i i i i i I 1 m I I 1 1 1 1 1 1 1 1 1 I I I I I I 1 1 1 1 1 I I 111 1 1 1 1 1 1 1 " 1 1 i i i " -4 - EXISTING ONE - STORY 1 l l 1 4:12 RESIDENCE 1 1 1 1 1rl I h1 1 1 1 f- 1 I I 1111 1 1 1 II 1 1 1 1 EXISTING SEPTIC T F.F. ELEV. 12.50 1 1 1 1 1 1 1 1 1 1 1 LOT -2 I I I I II 1 1 1 II 1 1 1 TO BE REMOVED 1 1 1 ILI - -IJI I I I I•- BLOCK -2 I I 1 I f 1 1 1 �l ( I I I � I I I�1 1 1 1 1 1 1 I 1 I -I- -L L L Lil N Irl I I I I 1 1 1 1 1 I II I 111 I I I I I III I I II I I I I I I I I III I � I II I I 1 1 1 1 1 1 1 II I I I I I I I I I II I I I I N II I 111 1 1 1 1 1 1 JI 1 I II I I I I I I I I III 11 I 111 I I I I I III I I I 1 1 1 1 1 1 1 1 1 I LO II I I I I I I I I III II I 111 I I I I I 111 I O O I � II 1 1 1 1 1 1 1 1 1 11 1 I I I 1 1 1 1 1 1 1 1 N I I I I I I I I 1 1, 1 1 I I I I I 1 1 1 1 1 1 II I I I I I I I I III II I I I I I I I I III _- I it i i l i -'-i i-i 1 11 iz II I I I I I I I I III I I ( I I I I I I I I d I 1 1 1 1 1 1 1 1 4 11 I I I I I I I I III II I I I I I I I I III EXISTING 1 1 1 1 1 1 1 1 1 1 1 III 1 1 1 1 1 1 1 1 EXISTING II 1 1 1 1 1 1 1 1 1 II PLANTER DRAINFIELD I I ( I I I I I I I I �i TO BE REMOVED = Y II I I I I I I I I III - 0 Q II I I I I I 1 1 1 1 II I I m II I I I I I I I I III 10 Lo 7jj II I I 1 1 1 1 1 1 III N N V) LLJ II I I I I I I I I III I I I 1 1 1 1 1 1 1 1 II I I 1 1 1 1 1 1 111 O II 1 1 1 1 1 1 1 1 III � L--- - - - - -J 1 I EXISTING ADJACENT NEIGHBOR WATER METER ASSEMBLY D NOTE: THERE ARE NOT A IERTINENT FEATURE ON ADJACENT PROPERTIES AND ACROSS THE STREET THAT MAY AFFECT THE SEPTIC SYSTEM INSTALLATION SITE PLAN 1/8" =1' -0" PROPERTY LINE 88.00' -NEW 4' -0" CONC. SIDEWALK 17' -0" PARKWAY\ S.W. 65TH PLACE EXISTING WATER METER ASSEMBLY .• 1 i LEGAL DESCRIPTION 10. VERIFY HEIGHT AND LOCATION OF WALL MOUNTED .14. ALL GYPSUM WALLBOARD SHALL BE INSTALLED AND LIGHTS WITH THE OWNER PRIOR TO INSTALLATION OF FINISHED IN ACCORDANCE WITH MANUFACTURER'S ELECTRICAL BOXES. INSTRUCTIONS AND IN COMPLIACE WITH THE F.B.C. 11. SMOKE DETECTORS ARE TO BE HARDWIRED AND 15. VERIFY ALL DIMENSIONS IN FIELD BEFORE INTERCONNECTED WITH A BATTERY BACKUP. FABRICATION OF ANY CABINET WORK, OR BUILT -IN 12. DOOR AND WINDOW OPENINGS ARE NOMINAL SIZES, EQUIPMENT. REFER TO THE DOOR AND WINDOW SCHEDULES & SHOP 16. BATHROOM FLOORS AND BASE TO BE OF IMPERVIOUS DRAWINGS FOR EXACT DIMENSIONS. MATERIAL AS PER F.B.C. 13. ALL CERAMIC INSTALLATION SHALL BE DONE IN 17. ALL GLASS USED INSIDE DWELLING SHALL BE ACCORDANCE WITH THE "Handbook of Ceramic Tile TEMPERED. Installation" PUBLISHED BY THE TILE COUNCIL OF AMERICA. WALL LEGEND NEW INTERIOR PARTITION EXISTING INTERIOR PATRON WALL CMU WALL , 1/4" =1' -0" 0 I 0 N t O I N N 00 I 00 i� `- s I O 2 COLTRAN JONM MOZl 11 i 1►7 NHAMI COLTRAIN AND JONES ARCHITECTS, P.A. AA 26000922 TELEPHONE (305) 285 -67231 FAX (305) 285 -6722 535 SW 8 ST. SUITE 100 MIAMI, FL. 33130 DESIGN I CONSTRUCTION ADMINISTRATION BUILDING INSPECTIONS I CAD PRODUCTION CONSULTANT/ NOTES APPROVALS /REVISIONS DATE QREVISIONS 03 -02 -2011 SEAL: OI Lo I Mark A Coltrain AR 0013380 N Richard K. Jones, AIA AR 0015755 SHEET TITLE: FLOOR PLAN AND SITE PLAN Job No. Drawing No. Drawn By: Date Plotted: A1,0 Date Scale: (VARIES - SEE DRAWING) Z 0 W ~' U > �. Z 0 W r. W wvcM 0 OL0� o W 0 W J 0 Cn LL Z ,q w M W C/) 0 0 0 Q CITY OF SOUTH MIAM; ` UILDING DEPT. I- RUCTURAr�ECTI0N SEAL: OI Lo I Mark A Coltrain AR 0013380 N Richard K. Jones, AIA AR 0015755 SHEET TITLE: FLOOR PLAN AND SITE PLAN Job No. Drawing No. Drawn By: Date Plotted: A1,0 Date Scale: (VARIES - SEE DRAWING)