11-72-016ELECTRICAL FLOOR PLAN SCALE 1/4' =1' -0" electrical notes. I. ALL WORK SHALL COMPLY WITH THE LATEST EDITION ON THE 'NATIONAL ELECTRICAL CODE' (NEC) 4 THE ' FLORIDA BUILDING CODE' 2. ALL CABLE SHALL BE COPPER UNLESS OTHERWISE NOTED AND APPROVED. 3. OUTDOORS UNDERGROUND CONDUITS SHALL BE SCHEDULE -40 PVC UNDER PAVED AREAS. 4. CONTRACTOR SHALL FURNISHED ALL LABOR, MATERIALS AND EQUIP. FOR A COMPLETE ELEC. INST. IN ACCORDANCE WITH THE ELECTRICAL DRAWINGS AND APPLICABLE CODES AND REGULATIONS. 5. ELEC. CONTRACTOR TO COORDINATE ALL OUTLET LOCATIONS WITH BLDG. AND ARCH. FIXTURES. 6. ELCT. CONTRACTOR TO PROVIDE EMPTY CONDUITS AS REQD. FOR TELEPHONE LINES 4 T.V. ANTENA. i. ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. S. ALL LIGHT FIXTURES AND FANS TO BE SELECTED BY OWNER, UNLESS OTHERWISE NOTED. 9. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 10. COMPLY WITH THE N.EjG. AND THE FLORIDA BUILDING CODE. 11. PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 12. OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 13. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 14. PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 15, COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURE. 16. CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 1-11. ALL CABLE SHALL BE COPPER EXCEPT WHEN NOTED OTHERWISE. 18, INDOOR CONDUITS SHALL BE EMT. 19.OUTDOOR CONDUIT SHALL BE SCHEDULE 40 PVC, MINIMUM COVER SHALL BE 24. 20. ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 21. ALL RECEPTS, LIGHTS, CLOSET LIGHTS AND SMOKE DECTECTORS IN BEDROOM SHALL HAVE ARC FAULT CIRCUIT INTERRUPTER PROTECTION. BEFORE BIDDING, CONTRACTOR SHALL PERFORM A THOROUGH INVESTIGATION OF ACTUAL CONDITIONS AT THE JOB SITE AND INCLUIDE ALL WORK REQUIRED TO INTRODUCE SYSTEM COMPONENTS INTO EXISTING STRUCTURES AND TO CONECTOR OR MODIFY EXISTING SYSTEMS AS INDICATED ON DRAWING OR NECESSITATED BY THE INSTALLATION PERFORM ALL SUCH WOW WITHOUT ADDITION TO THE CONTRACT COST. WHERE INDICATED ON DRAWINGS REMOVE OR RELOCATED EXISTING SYSTEM COMPONENTS AND PROPERLY PATCH AND FINISH RESULTING OPENINGS IN THE BUILDING STRUCTURE WITH THE SAME MATERIAL AS THOSE ADJACENTS TO THE OPENING. ELECTRICAL LEGEND SWITCH e7- DUPLEX RECEPTACLE .0 EXTERIOR LIGHT �- SPECIAL OUTLET LIGHT FIXTURE O. SMOKE DETECTOR RING BUTTON SERVICE: 200 AMPS. 120/240V 10 3W FEEDERS: (3) +'210 CU. THHN IN 1 1/2'0 COND. 1) ELECTRICAL LOAD SUMMARY EXHAUST FAN w SQUARE FEET =2,280 sq.ft (EXIST.) H TELEPHONE JACK =5-15 sc St (NEW ADD IT.) ELECTRICAL GEN. LIGHTING e 3W15q. ft. 8,5(05 w SMALL APPLIANCES 4,500 w REFRIGERATOR 1,500 w RANGE 12,000 w DRYER 5000 w E.W.H. 5,000 w WASHER 1,500 w BATH RECEPT. (3) 4,500 w TOTAL 42,565 w 2) CONNECTED LOAD GEN. LIGHTING SPACE CEILING FAN NOTE: INTERRUPT RATING CAPACITY SHALL BE 10,000 AMPS AS UP DATE NEC 110 -S FIRST 10000w e l 00% 10,000 w REMAINDER e40% 13,026 w A /C. LOAD 11,040 w TOTAL 34,066 w 34,066 w/240V =142 AMPS SERVICE PROVIDED= 250 AMPS 3) NEUTRAL LOAD CALCULATION GEN. LIGHT.,UJASHER 4 SMALL APP. 14,565 w FIRST 3,000 AT 100 io EXHAUST FAN w TELEVISION JACK H TELEPHONE JACK migzi ELECTRICAL w PANEL NOTE: INTERRUPT RATING CAPACITY SHALL BE 10,000 AMPS AS UP DATE NEC 110 -S FIRST 10000w e l 00% 10,000 w REMAINDER e40% 13,026 w A /C. LOAD 11,040 w TOTAL 34,066 w 34,066 w/240V =142 AMPS SERVICE PROVIDED= 250 AMPS 3) NEUTRAL LOAD CALCULATION GEN. LIGHT.,UJASHER 4 SMALL APP. 14,565 w FIRST 3,000 AT 100 io 3,000 w REST AT 35io 4,04-1 w RANGE AT -1051. 8,400 w DRYER AT -10io 3,500 w OTHER LOAD 6,000 w TOTAL NEUTRAL LOAD 24,541 w AT 240 VOLT= 104 AMPS. 120/240 V, 3 WIRE, 1 -PHASE 0210 THHN, Cu IN VCS ELECTRIC METER 04- 3/4' " 4 Cu GROUND IN 1/2, PVC TO gib' x 10' C.U. ROD (LOOPED) TO FOUNDATION STL. (MIN. 20 L.F.) electrical riser TYPE: LOAD CENTER MAIN BUS: 200 SERVICE: 1 PH 3W PANEL II A II NEUTRAL: 200 - VOLTAGE: 120/240 V. MAIN:200 ,- P.' AM I�RK.I MOUNTINGS: SURFACE (ALL 20 AMPS, I POLE CKTS. EXCEPT AS NOTED) LOCATION: SHOWN O} REMARKS � N � REMARKS Uj, ? � _ 20 1 * 1/2' 12 SPACE I 2 SUB PANEL 'A' 12 1/2' * 1 100 15 1 * 1/2' 12 GEN. LIGHTING SPACE 9 4 12 1/2' * 1 20 I00 20 1 30 2 8,200 3/4' 8 CU 5 6 AHU. 6 3/4' 9,800 2 60 8 30 1 * 1/2' 12 GEN. LIGHTING 7 8 DISWASHER 14 1/2'1 1,200 1 60 11 30 1 5,000 1/2' 12 DRYER 9 10 SPACE 1 * 1/2' 12 GEN. LIGHTING 13 14 30 14 1/2' 1 * 1 15 11 12 SPACE * 1/2' 12 GEN. LIGHTING 15 16 GENE. LIGHTIN 20 1 1,500 1/2' 12 WASHER 13 14 GENE. LIGHTIN 14 1/2' * 1 20 ALARM 14 20 1 * 1/2' 14 GEN. LIGHTING 15 16 GENE. LIGHTIN 14 1/2' * 1 20 21 22 KITCHEN LIGHTIN 14 1/2' * 1 SPACE 17 18 GENE. LIGHTIN 14 1/2' * 1 20 6 OVEN 25 26 SUB PANEL 'A' SP ACE 19 20 SPACE 27 28 50 CONNECTED LOAD: FEEDER: SEE RISER * LIGHTING t RECEPTACLE 2055 SOFT ID 3W /sq.ft =8,565 W. FED FROM' (AFM (AFCIi (AFCI) :ARC FAULT CIRCUIT INTERRUPTER PROTECTION SERVICE: I OPHD ENTER SI 5 PA* 1 E I 11 A II NEUTRAL: 100 VOLTAGE: 120/240 V. �.J PANEL J-. MAIN: 100 AMP. A BRK. MOUNTING: SURFACE (ALL 20 AMPS, 1 POLE CKTS. EXCEPT AS NOTED) LOCATION: SHOWN p REMARKS N a REMARKS Uj, 0 d) w 20 1 * 1/2' 12 BATH. RECEPT. 1 2 GENE. LIGHTIN 12 1/2' * 1 20 15 1 * 1/2' 12 GEN. LIGHTING N 4 BATH. RECEPT. (CFI) 12 1/2' * 1 20 20 1 * 1/2' 12 GEN. LIGHTING D 6 REFRIGERATOR 12 1/2' 1,500 1 20 O 1 8 20 1 * 1/2' 12 GEN. LIGHTING 9 10 DISWASHER 14 1/2'1 1,200 1 15 11 12 GENE. LIGHTIN 12 1/2' 1 1 20 20 1 * 1/2' 12 GEN. LIGHTING 13 14 BATH. RECEPT. 14 1/2' 1 * 1 15 20 1 * 1/2' 12 GEN. LIGHTING 15 16 GENE. LIGHTIN 14 1/2' * 1 15 30 2 1 ,500 1/2' 10 W/H 17 18 ALARM 14 1/2' * 1 15 19 20 30 21 22 KITCHEN LIGHTIN 14 1/2' * 1 15 23 24 50 1 12,000 3/4' 6 OVEN 25 26 SUB PANEL 'A' 50 27 28 50 29 30 50 31 32 ISAW CONNECTED LOAD: FEEDER: SEE RISER FED FROM (AFCI) :ARC FAULT CIRCUIT INTERRUPTER PROTECTION O.N. ELEGTRIC SERVICE FROM FPL TRANSFORMER '3) 0'210 CU. THHN IN 2'41 CONDUIT 2 MC5 200 AMPS BRK. NEMA 3R P10,000 AIG. W/MAIN DISC. (3) "210 CUTHHN IN 2'41 CONDUIT ,'2) NV Ox10' GROUND RODS DRIVEN 8' DEEP E 6' APART n.t.s. t '3) 04 CU. THHN IN 1'41 CONDUIT 200 SUB AMP PANEL 100 AMPS 120/240V E.P. (A) 10 3111 2F W.P. 16132 SPACES 200 AMPS 1201240V 10 3W 21= W.P. 40 SPACES ELECTRICAL PNL BOARD W/MAIN DISC. 3/4' COOPER WATER PIPE STUB -OUT _I r � � m a D LL w JNJm W Dh QILI0 �Q n �11 Owl' - Ln :20 W j