Loading...
11-72-0110 C4 �r EXIST. BEDROOM 34' -10' • EXIST. BATH. EXIST LIVING ROOM ENTRY \% WH 0 EXIST KITCHEN I ON R1 11111111114: 19109101 ii] EXIST DINING ROOM ,_p 105 TIE -DN IN GROUTED FILLED CELL 6 46' MAX. (TYP) 4 EA, SIDE OF OPE- NING BETWEEN 3' 4 6' WIDTH. ■ -- ■ _ 8'x12' CONC. TIE COLUMN -2m I I W/ (4) 05 4 03 TIE 0 12' O.C. I I v I (TYP.) I I 2 'xl ' CONG. FOOTING W (2 )S CONT. z I■I ■I 4' THICK CONCRETE SLAB W /6'x6', 10/10 WWM. ON 6 MIL. I 'VISQUEEN' VAPOR BARRIER ;q- C4 ON 10' MIN. WELL COMPACTED FILL 01 ■ ( , ELEv.�+14 NGYD I 8'x12' CONC. TIE COLUMN W/ (4) 05 4 *3 TIE g 12' O.C. I ■ (TYP.) I I MATCH TO EXIST. FLOOR - - - - -- =2� - - -_j IN MI IN NJ ■■ ■ ■■ 2b' -6' / ELEY.■ ' ■413.13A545' NGYD w EXIST. WOOD FLOORL TO REMAIN "ni n - -- WF -16 - - - - -� ■ ATCH TO EXIST. FLOOR 4' THICK CONCRETE SLAB ;+ ■ I �Q W /6'x6', lO /IO WWM. ON 6 MIL. ' ■ 'VISQUEEN' VAPOR BARRIER — ON 10' MIN. WELL COMPACTED FILL WF -16 41-21 111-01 ELEY.■ t ■ +1lAl.41' NGVD 1 TIE -ON IN GROUTED FI L E0 CELL 6 48' MAX. TRUSSES BY OTHERS R19 INSULATION REQ. 1/2' GYP. BD. ON —� 1' x 3' WD. FURR. STRIPS 6 16' O.C. 1' x 4' P.T. WD. FIRESTOP 1/2' GYP. BD. ON 1' x 2' WD. FURR. STRIPS -W 16' O.C. R 4.1 GATT INSULATION REQ. REINF. MASONRY STL. BEYOND CEMENT TILE ROOF FOAMED OVVER '30 ASPHALT PA_P_ ER HOT MOPPED ON *30 ASPHALT PAPER TIN - CAPPED AT WITH 3/4' -Sd RING- SHANKED NAILS 12' O.C. AND 6' O.C. AT OVERLAP AREA OVER !a THICK EXTERIOR PLYWOOD WITH STAGGERED JOINTS NAILED AT 6' O:C. _ AT INTERMEDIATE SUPPORTS AND PANELS EDGE AND •4' AT EAVES.' ROOF NAILING: -_ NAILS 6' O.C. AT F4NIEL EDczE5 -- AND e INTERME_ D SATE SUPPORTS 4 GABLE ENDS. 12 3 T7, 4' THK. CONC. SLAB W1 6' x 6' x *10 WWM ON 6 MIL. POLYETHYLENE VAPOR BARRIER II WD. BASE BD. �I COMPACT FILL TO-- 95% PROCTOR MAX. DENSITY 1/2' EXPANSION JOINT REQ. MIN. CLEAR REQ. FOUNDATION PLAN t scale 1/4 " =1' -0" — ROOF NAILING: Sd NAILS 6" O.C. AT PANEL EDGES AND a INTERMEDIATE SUPPORTS 4 4" O.C. GABLE ENDS. CUT EXIST. OH. AS REQ'D. 2' x 8' WD. JOISTS a 16' O.C. 300 FELT WRAP AROUND JOIST - MTW (BY USP) GALV. TWISTED STRAP W/ (14) -10D NAILS TO EA. JOIST 4 ( -1) 3116'0 x 11/4' TAPCON SCREWS ATTACHED TO EXISTING: TIE BEAM connection detail scale: 3/4'=I'-O' SOIL STATEMENT: THE ENGINEER HAS VISITED 4 OBSERVED THE SITE AND FOUND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED FURTHERMORE, UPON BREAKING OF GROUND. A LETTER SHALL BE SUBMITTED TO THE BUILDING OFFICIAL VERIFYING AND ATTESTING THAT THE SITE CONDITIONS ARE SIMILAR TO THOSE WHICH THE DESIGN WAS BASED ON. NOTE: CHIP OUT EXISTING F❑❑TING LEAVING REINF, INTACT. APPLY BOUNDING AGENT AT EXIST, CONC. SURFACES TO REMAIN PRIOR TO POURING NEW FOOTING, U �CONC. COL. BLOCK :. zz •. ' REINF. CONC. FTG. . •4 EXIST. FOOTING 4 #5- BOTT. CONT FOOTING CONNECTION DETAIL get 5 #5- TOP. X 6' -0' LONG 45 * 24' LONG DOLLELL DRILL WTO EXM ER 6ER NEW C EPO TAR COL 4 SLAB #5- TRANSV. @ 12' O.C. n. t. s. C11T EXISTMG CONC.BEAM 3' M AREA WMRE NEW COW=0U8 C01-*�IEC I DRILL 3 /4'HOLE R)/6' DEPTH ATTACH RSBARS W/H*14 STRENGTH EPDXY GROUT NEW 8'x12' C *r=E BEAM SEE PLANS J EXIST CONCRETE I ALL WORK SHALL COMPLY WITH THE FLORIDA BUILDIN6 CODE, THE AMERICAN CONCRETE INSTITUTE ti gg I �GlCC W4LL ALL OTHER APPLICABLE CODES AND REGULATIONS. DESIGN FOR WIND COMPLIES W/ �••�- L''.. ;j`j� 1 i-i MIAMI ASGE '1 -18. DuILDING DEPT ALL MANUFACTURERS OF REINFORCING AND STRUCTURAL STEEL, PRECAST (PRESTRE55ED) CONCRETE, STRUCTU I AND PREFABRICATED WOOD TRUSSES SHALL SUBMIT SHOP DRAWIN65 TO ENGINEER FOR APPROVAL INSTRUCTION EXISTING CONSTRI ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ARE TO BE VERIFIED BASED ON 8'x12' CONCj7OL. aul4r 5o VERT. RENF.BARS 10103 TIES AT 8' OZ. ICTION Started Column Detai • ` :�.. • :• O •• a•'• O.N. J .Q 11 REFER TO ANCHORAGE DETAIL A OR C (2) -05 STL. RODS MIN. 60' BENT O CORNERS TO ASSURE CONTINUITY 3'x3'x 26 GA MTL. EAVE DRIP NAILED 6 4' O.C. I' x 2' WD. BLK.'G 2' x5' P.T. WD. FASCIA STUCCO 4 MTL. RIB LATH ON W1 4'x22' SOFFIT VENT. 4 INSECT SCREEN e 48' O.C. 8' x 12' CONC. TIE BM. W1 (4) -*5 4 *3* Q 48' O.C. NOTE: FIRST (4) -*3* ,m CORNERS TO BE g 12' O.C. STUCCO IN TWO LAYERS 8' CONC BLOCK W1 1* 5 VERT. IN GONG. FILLED BLOCK CELL 6 V-81 O.C. MAX. PROVIDE STD. HOOK AT TOP (TYP.). N FIN. GRADE 20' x 12' CONC. WF W1 (2) -05 CONT. MIN. CLEAR REQ. ical section (new wa scale: s /4' =1' -0' I ST U(��-TU AL NOTES ALL WORK SHALL COMPLY WITH THE FLORIDA BUILDIN6 CODE, THE AMERICAN CONCRETE INSTITUTE ti ALL OTHER APPLICABLE CODES AND REGULATIONS. DESIGN FOR WIND COMPLIES W/ �••�- L''.. ;j`j� 1 i-i MIAMI ASGE '1 -18. DuILDING DEPT ALL MANUFACTURERS OF REINFORCING AND STRUCTURAL STEEL, PRECAST (PRESTRE55ED) CONCRETE, STRUCTU RAL SECTION AND PREFABRICATED WOOD TRUSSES SHALL SUBMIT SHOP DRAWIN65 TO ENGINEER FOR APPROVAL BEFORE FABRICATION. DIMENSIONS AND LENGTHS OF FABRICATED UNITS SHOWN ON SHOP DRAWINGS ARE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ARE TO BE VERIFIED BASED ON ;,yl, �VED BV`,,,, ;;� ;J, ACTUAL FIELD CONDITIONS. IN THE CASE OF REINFORCING BARS, STRICT ADHERENCE TO THE BAR ,,•�.� f :M._ PLACING DIA6RAMS/LEN&THS SHOWN ON THE STRUCTURAL DRAWINGS MUST BE FOLLOWED UNLESS OTHERWISE SHOWN BY THE ENGINEER ON SUCH PLANS. GENERAL CONTRACTOR OR ARCHITECT MUST MAKE ANY REVISIONS OR CORRECTIONS, IF ANY, ON SHOP DRANIN65 BEFORE SUBMITTING TO THE ENGINEER FOR FINAL APPROVAL. ALL CONCRETE SHALL DEVELOP THE FOLLOWING MINIMUM 28 -DAY COMPRESSIVE STRENGTHS UNLESS OTHERWISE SHOWN ON THE STRUCTURAL PLANS: PRECAST . ............................... ..........................5,000 PSI ALL OTHERS .......................... ...........................3,000 P51 STRUCTURAL STEEL BOLTS SHALL CONFORM WITH A.5.T.M. A -325. SLUMP OF CONCRETE SHALL NOT EXCEED 5 INCHES. A MINIMUM OF 5 CONCRETE SPECIMENS SHALL BE ALL STRUCTURAL LUMBER SHALL BE SOUTHERN PINE (NO. 2 OR BETTER) WITH THE FOLLOWING MINIMUM OBTAINED FROM EACH 50 CUBIC YARDS OR FRACTION THEREOF AND SHALL BE TESTED ACCORDING TO STRENGTHS. A.S.T.M. G -39. USE REGULAR WEIGHT (145 PCF) FOR ALL STRUCTURAL MEMBERS. SIGNED AND SEALED BENDING ............... ............................... ..........................1,500 PSI COPIES WITH THE RESULTS OF SUCH TESTS SHALL BE DELIVERED TO THE ENGINEER FOR REVIEW. ALL TENSION PARALLEL TO &RAIN ................. ............................825 P51 ADMIXTURES SHALL BE APPROVED BY THE ENGINEER. SHEAR PARALLEL TO GRAIN ................... .............................40 1=51 COMPRESSION PERPEND. TO GRAIN ............ ............................565 PSI REINFORCING STEEL SHALL BE GLEAN, DEFORMED BARS OF NEW BILLET STEEL, FREE FROM OIL, SCALE COMPRESSION PARALLEL TO GRAIN ....................................... 1,650 PSI AND RUST, AND CONFORMING WITH A.S.T.M. A -615 GRADE 60. WELDED WIRE FABRIC, SHALL COMPLY WITH ELASTIC MODULUS ....................... .......................1,600 ,000 PSI A.S.T.M. A -185. ALL SLAB5 ON 6RADE SHALL BE POURED OVER A .006 IN. VISQUEEN MEMBRANE ON GLEAN, WELL ALL REINFORCING SHALL HAVE THE FOLLOWING MINIMUM CONCRETE COVERAGES: FOOTING S .................. .............................3" COMPACTED INORGANIC FILL. ALL COMPACTED SOIL SHALL ATTAIN A MINI Q5% DENSITY AT OPTIMUM MOISTURE AS DETERMINED BY THE STANDARD PROCTOR TEST. SLABS POURED ON GROUND .... .........................I -1/2" STRUCTURAL SLAB POURED ON &ROUND .................a" BOTTOM OF ALL CONCRETE TIE BEAMS SHALL BE DROPPED OVER ALL MASONRY OPENINGS NNLESS A GRADE BEAMS ..... .............................3° STRUCTURALLY REINFORCED BEAM IS SHOWN) WITH A MINIMUM BEARING OF 8" AT EACH END. PROVIDE BEAMS AND COLUMNS ........ .........................1 -1/2" #5 ADDITIONAL LONGITUDINAL BARS AND #3 TIES ®12" ON CENTERS THROUGHOUT HOUT OPENING. SUSPENDED STRUCTURAL UCTURAL SLABS ..........................3 /4" EXTERIOR CANTILEVER SLABS .. .............................I" GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND SHORING FOR ALL STRUCTURAL MEMBERS, WALLS AND NON - STRUCTURAL MEMBERS DURING THE COURSE OF STRUCTURAL STEEL SHALL BE NEW CONFORMING WITH A.S.T.M. A -36. WELDING ELECTRODES SHALL BE CONSTRUCTION. TYPE E- "10XX. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE DIMENSIONS. GENERAL CONTRACTOR STRUCTURAL STEEL COLUMNS SHALL COMPLY WITH A.S.T.M. A -500 OR A.S.T.M. A -501. ALL STEEL SHALL, VERIFY ALL DIMENSIONS AND ACTUAL CONDITIONS EXISTING AT THE FIELD. IF UNUSUAL OR COLUMNS SHALL BE FILLED WITH 3,000 PSI PEAROCK CONCRETE. UNFORESEEN CONDITIONS ARE ENCOUNTERED NOTIFY ENGINEER BEFORE PROCEEDING WITH THE WORK. c,TRIIr'MMAl c,TFFI Rnl Tc, 4:,HAI I e nW;=nRM WITH A4TM A_=%')c; w 0 M 0 �� �- LO r� WOIn 1_0 JN�0' LL- • Ld �L- °Lo 6 p LO w C) Lo 0 (� Ld LLJ 0- z <�' JUrn .. ZN �w3: Q) LL V) p T_ rk�' 0 ,C U°0- LL v -4 -(q zO „ a C� U .q z W(3 C).o V O a ,> a d) 1 L O O t- CAD FILE: ocHOA LAYER: S -1 1 of 2