Loading...
10-668-009HVAC LEGEND ® SUPPLY AIR DIFFUSER DRAIN w/ 3' TRAP RETURN AIR GRILLE OTHERMOSTAT I 'x 1/8' F—� SUPPLY AIR DUCT RECTANGULAR CROSS SECTION 14'X 1/8' RETURN AIR DUCT RECTANGULAR CROSS SECTION GREEN AREA TURNING; VANE �- VOLUME DAMPER, IN LINE GsALV. STEEL VOLUME DAMPER, AT TAKE OFF FIRE STOPPING FLEXIBLE ROUND DUCT AA.U. SUPPORT SPLITTER DAMPER 102 FAN A— —, FIRE DAMPER @ SMOKE DETECTOR Nil Licl. 3/4' SUCt. OPPOSED BLADE DAMPER RHEEM- RAPL- 03rbJAZ ELECTRIC STRIP HEATER - - -- MOTORIZED DAMPER R/A THRU Ii.9 REFRIGERANT LINES MECHANICAL ATTACH TO OUTSIDE CONDENSING PLENUMS AND RETURN UNIT THRU ATTIC SPAG W/FLEXIBLE CONN. 230 DUGTLY R/A —Y-i DUCT WHEN APPLY 3 /4' Insul. 3/4' CONDENSATE WAWBER SIZE MAX. SPACING; 2 SOFT DRAIN w/ 3' TRAP WW -0' 2 THRU 48QFT. I 'x 1/8' UNION AND C.O TO 4 IOSQFT 14'X 1/8' S' -0' GREEN AREA Ns'x Val n FIRE RATED ROOP)FLOOR CEILING ASSEMBLY GsALV. STEEL x FIRE STOPPING GO AA.U. SUPPORT SMOKE CONTROIL 102 x (SELF - STANDING) 121/4xl2l/4xlI3/4 60 W /GRILLE, (o'# DUCT DA FOR OR BIRDS CAP 4 WAI IR Nil Licl. 3/4' SUCt. L I RHEEM- RAPL- 03rbJAZ 3.0 - - -- - - -- R/A THRU Ii.9 25,500/35 ,200 LOUVER DOOR —�-► 32x45x33 230 208 - 23011160 WHEN APPLY 3 /4' Insul. AIR CONDITIONING SYSTEM - GENERAL NOTES: I. DUCTWORK SHALL BE 11/2' THICK, 3 POUNDS PER CUBIC FOOT DENSITY FIBERGLASS WITH VAPOR BARRIER, UNLESS OTHERWISE SPECIFIED. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO 'ASHRAE' AND 'SMACNA' STANDARDS. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH RNFPA' STANDARD NO. 90A AND /OR 908. DUCTWORK AND COMPONENTS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. 2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN THE FABRICATION AND INSTALLATION OF THE SYSTEM. 3. DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: INSIDE OUTSIDE RELATIVE HUMIDITY COOLING - 16' DB 91 DB - 19 WB 5091 TO 60% HEATING - 10' DB 41' - DB 4. ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY SO THAT NOOBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS REQUIRED FOR EASY ACCESSIBILITY. 6. A/C SYSTEM SHALL BE CONTROLLED BY A PROGRAMtA5LE THERMOSTAT. MOUNT PROGRAMMABLE THERMOSTAT 5' -0' ABOVE FINISHED FLOOR, UON. 1. ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF- FUSERS TO HAVE OPOSED BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREGUIDE OR APPROVED EQUAL WDTH ENAMEL FINISH 8. UNDERCUT DOORS P AFF. FOR R/A FOR ROOMS WITH LESS THAN 110 CFM FOR ROOMS WITH OVER 110 CFM PROVIDE R.Ata. AND TRANSFER DUCT. 9. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE WROUGHT COPPER ALL JOINTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 5% SILVER PIPING INSTALLATION NOT LESS THAN 3/4' THICK 'ARMAFLEX'. LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO EQUIPMENT MANUFACTUPJ =R'S RECOMMENDATIONS FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT MANUFACTURER ALL PIPING; SHALL BE EVACUATED PER GOOD PIPING PRACTICE BEFORE START -UP. �`.� `— CEILING °� PARTITION PERFORATED CAP FOR —VENT, 12' HIGH --- -FLOAT SWITCH TO SHUT DOWN A/C UNIT AS PER SECTION 301.2.4 OF FBC 2'A /C G.D. UNDERSLAB TO COMPLY WITH FBC (PLUMBING) SECTION 1103 AIR HANDLER UNIT INSTALLATION DETAIL NO SCALE RDOF CAP-... GENERAL NOTES: THE COMPLETE SET OF CONSTRUCTION DOCUMENTS CONSISTS OF DRAWINGS, DETAILS 4 SPECIFICATIONS. IN THE EVENT OF A DISCREPANCY, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT ANp /OR ENGINEERS FOR CLARIFICATION. ANY DEVIATION FROM THESE DRAWINGS, WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT AND /OR ENGINEERS IS PROHIBITED. GENERAL CONTRACTOR OR SUBCONTRACTORS ASSUMES FULL RESPONSIBILITY FOR ANY UNAUTHORIZED DEVIATION FROM THE W- ORMATION DEPICTED IN THE CONSTRUCTION DOCUMENTS. ENGINEERS ARE NOT RESPONSIBLE OR LIABLE FOR ANY DISCREPANCY BETWEEN THESE DRAWINGS AND THE EXISTING CONDITIONS. ANY WORK PERFORM ON THE PROPERTY PRIOR THESE CONSTRUCTION DOCUMENTS AND WILL NOT MATCH WITH THE INFORMATION IN THE EXISTING CONSTRUCTION DOCUMENTS ON CITY RECORDS OR IT WAS NOT VISIBLE AT TIME OF INSPECTION OR THE WORK WAS DONE ILLEGALLY WITHOUT PERMIT BY OTHERS AND WILL CAUSE A DISCREPANCY WITH THE NEW DRAWINGS IS THE RESPONSIBILITY OF THE CURRENT OWNER OF THE PROPERTY AT HIS OWN EXPENSE TO PERFORM ALL THE NECESSARY CORRECTIONS IN ORDER THAT ALL WORK IS IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE AND THE LOCAL ORDNANCE AND WILL MATCH WITH THE NEW CONSTRUCTION DOCUMENTS FOR WHICH WORK WILL BE PERFORM. PROVIDE 4 CLEARANCE SUPPLY AIR DUCT ALL AROUND AHU (SEE PLAN VIEW I AIR FLOW GLG. S/M 26 G. SIZE B EFEND OF TYPE OF FAN SEE FAN SCHEDULE. EXHAUST DUCT EXHAUST FAN 4 DUCT - DETAIL KT.e. INSUL R -6 METAL ROUND FITTING QUADRANT OPERATOR TO BE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY TED FLEX. DUCT. 141 F/GJLITH POLYETHELENE- JACKETAND STEEL WIRE REINFORCING(R -6) AIR FLOW SEAL JOINT WITH EPDXY 4 DUCT TAPE door— .,j/ - AIR FLOW p JRBLE VOLUME — SEAL JOINT WITH EPDXY 4 DUCT TAPE PEIa;OR„ATED DIFRJSER TYPICAL DIFFUSER CONNECTION DETAIL NO SCALE ♦ ANID EQUIFMENT NOTE: CONNECTION DETAIL5 • — ♦ SPECIFICATIONS GPM PLANGE-1 CLOSURE (01 FLANGE GFM CL05UR!: 2W'2' SQUARE SWERS ml _j A% • �� — • 010AI/4' SWEET METAL MIN. 2 - - SIDE SCREWS 12' (MAX.) • II METAL ScReL MIN. 2 PER SIDE L22 GAUGE SHEET METAL C;AUC;E I' X P X 1' CHANNEL SHPOEr.EKTETE FASTENED TO i' X 1' X I' METAL FLANGE FIGURE 2 -23 NOTE: SHEET METAL CONNECTIONS FABRIC AND MADE (GF) GLASS EXCEPTION: WHEN CONSTRUCTION PRESSURE CLASS IS 1' WiS. OR LESS AND SHEET METAL SURFACES ARE CLEANED CAREFULLY UL LISTED PRESSURE- SENSITIVE ALUMINUM TAPE MAY BE USED. AL CONNECTIONS OF FIBROUS GLASS DUCT TO EQUIPMENT AND METAL DUCT MUST BE MECHANICALLY ATTACHED 12' (MAX.) ON CENTERS SMACNA DETAIL (PAGE 2.14) FIGURE 2 -24 DUCT BORD BEARING PLATE FLANGE ON SHEET CLOSURE METAL DUCT,CLINCH LOCK OR DOVE -TAIL METAL ok PEGIFI FIGURE 2 -26 22 GAUGE -/ - SCREW POP RIVET S X 3T METAL OR SPOT WELD TO 11 EQUIPMENT FLANGE FIGURE 2 -25 6' MIN IF HEATING EQUIPI LENT FIGURE 2 -21 EXIST. A.N.U. REF. EXIST. KITCHEN EXIST. LIVING= ROOM EXIST. TERRACE MECHANICAL PLAN- SCALE: 1/4"=V-0" Woo Ifta :s ___ -WOOD SCREW STRAP I ', 22C. J- -FOR DUCTS OVER 48' WIDE, FASTEN UNDER BOT OF DUCT. DUCT SIZE WAWBER SIZE MAX. SPACING; 2 SOFT I 'x W WW -0' 2 THRU 48QFT. I 'x 1/8' 5' -0' 4 IOSQFT 14'X 1/8' S' -0' OVER Ic6ca.FT Ns'x Val , 1 ~i►*2' MN. G DUCT HANGING DETAIL lw_)) PERFORATED CAP MIN. 12' ABV AHU EXIST. EXIST. EX CUM EX Cll'1 BATH CLOSET /--] GO. AINTE EXIST. EXIST. CLOSET EXIST. ELECT. J METER AND DISC. SEE ELECT. PLANS REF. LINES THRU CLCs. SPACE 344 Llq. 3/4' Suct. 4 -14' Insul. EXIST. DINING: ROOM � I I I I I i 1 I L---------------- i 1 I I I i I I I I 1 I I I I I CONDENSING UNIT I I I P I I I CONCRETE PIPE INSULATION PAD SHALL BE ' NOT LESS THAN 4' THICK I I I REFRIGERANT LINE TO AIR HANDLER ANCHOR W/POWER DRIVEN � STUDS OR 3 /8'X1.5 "LG. THRU CEILING SPACE TAP -CONS OR LAG BOLTS . W/ SHIELD6 INSIDE C.U. THRU BASE PLATE TO WITHSTAND WINDS OVER 146 MPH WITH AN ANCHOR BOLT OF 500 POUNDS MIN. PULL OUT CAPACITY. L ---------- CONDENSING UNIT INSTALLATION DETAIL NO SCALE HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR HP An x FIRE DAMPER (S) DIMENSIONS WxLxH (N.) x SMOKE DAMPER(S) TOILET EX. FAN x FIRE RATED ENCLOSURE 48 x FIRE RATED ROOP)FLOOR CEILING ASSEMBLY 8x81/2x5344 x FIRE STOPPING EF02 x SMOKE CONTROIL 102 x 12011160 121/4xl2l/4xlI3/4 60 CONDENSATE DRAIN CONNECTOR 0 THIS DIMENSION SHALL BE AS RECOMENDED BY THE AIR HANDLING UNIT MANUFACTURER. ® THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR TO ENSURE THAT THERE WILL BE SUFFICIENT CLEARANCE BETWEEN THE DRAIN AND THE FLOOR. © CONNECT TO AIR HANDLING UNIT DRAIN. _ —a r r N X t N I 1 I 1 I I `�✓ • X11 4 ST A� LOUVER • FaJ i axe, BEDROOM *1 IfxB CU! 8'a IU ■ ■ ■ ■■ ■II■ ■VII ■ ■ ■ ■ ►��' •# BEDROOM 02 '''E Y _ 150 CFm 0XI&' z IRACs r----------------------------------- i I I 0 I I X I MASTER BEDR" I. I I I I I 1 I 1 I I I I I I I I I L------------------------------ - - - - -J MASTER - ------- - - - - -- ---- - - - --� BATH 1 � � I L_j 1 I I 'I I — I f— I 6 4 I S00xh EFL" 4'4 /®' I _ I �r� I 8x8, 4W I I I' I I I W. I. CL. I I I X � �I L----- --------____ ---------- - - -� FAN SCHEDULE FAN • MANUFACTURER AND MODEL NO. RPRPM HP An CFM ° Sp ELECT. SERVICE VOLTS/PHI/Hz DIMENSIONS WxLxH (N.) WEIGHT LBS. REMARKS TOILET EX. FAN GARNES- vCDD008C 1280 48 1061/8, 120/1160 8x81/2x5344 40 W /GRILLE, 4'41 DUCT DAMPER 4 ROOF CAP 4 WAUIRE MESH FOR BIRDS PROTECTION EF02 CARNES- VCDDOISC 710 102 150 s 1/8" 12011160 121/4xl2l/4xlI3/4 60 W /GRILLE, (o'# DUCT DA FOR OR BIRDS CAP 4 WAI IR Nil Licl. 3/4' SUCt. L I RHEEM- RAPL- 03rbJAZ 3.0 - - -- - - -- - - -- Ii.9 25,500/35 ,200 NOT OR EQUIVALENT EQUIPMENT AIR CONDITIONING SCHEDULE UNIT MANUFACTURER AND MODEL NO. NOM. TONS NOM. CFM ESP IN WG. ELECT. HEAT KW TOTAL LA/HP COOLING: CAP. S/T BTUW • 95' 4 6'1' W O/A CFM DIMENSIONS WxLxH ONJ WEIGHT LBS. ELECT. SERVICE VOLTS/PH /Hz SEER REF TINES "E AE�-{U RHEEM- RHLL- HM361"tJA - - -- 1200 .40 10 21/1/2 Q - - -- 18x22x43 106 208- 230/1/60 15.0 Nil Licl. 3/4' SUCt. L I RHEEM- RAPL- 03rbJAZ 3.0 - - -- - - -- - - -- Ii.9 25,500/35 ,200 - - -- 32x45x33 230 208 - 23011160 M� L.L. 3 /4' Insul. NOM. OR EQUIVALENT EQUIPMENT HISTORY OF DRAWING ISSUED DESCRIPTION DATE OF ISSUED PROGRESS SCALE `tZ3 PERMIT DRAWING Y.T. �] CONSTRUCTION REVISION BY w . _ 1 SHEETS I.L 0 u Q Z 4w_j Q Q Q QW� co W W�Q Z (� 0 W co � O ^^ ti I.�L M� L.L. M to �j C) Z (y) CO U Z _ LL Z Q Q N_ CL (ij CD li 1 N ) O W W M D F 1 U uj CD W Q M (� 00 co co to U M_ c J 0 CD w Q H- Z O w 0 s tV s.y t N ch " r' . W "Z.�.� � U ca DATE 02 -19-10 SCALE AS NOTED DRAWING Y.T. JOB SHEET OF w . _ 1 SHEETS