Loading...
10-668-001Cti w co N 511E FLAN. SCALE: 'Ia '=1' -m' 0 & i -,AI I� 1 �N o � a EXIST. , EXIST .6 H. MEN I' cul FENCE N W SERV. FGO TYR GATE E3 YALVs= 3139' TO CITY o� SELLER 4' SAN *I /s "/Ff (33 FW � 0 , C1O I 140.00 1 (M &R) TYR 102' CW HOSE EXIST. ELECT. METER B� R. 4' SAN * ys' /PT t DISC. COORDINATE (11 NO W/ ELECT. PLANS NO SLAB ON GRADE BELOW ROOF CUT PORTION - OF EXIST. SLAB NEW C.U. $3 - �- 4' SM* V.')FT - - - -- (Il Flu -- � EXIST. G.U. "I$2 EXISTING ONE STOR To REMAIN Y CBS RES. # 1703 - -� TO REMA IN 4' SANolie')FT� 1 1 'eli '/FT (I6 Flu 7 -WAY L - - -, (16 I�u) F. F EL. 10.10' N.G.V.D. 11 GREEN OF EXIST. DECK EXIST. POOL 4 CONC. DECK TO REMAIN ARCH 1 TECT'5 NOTE TO THE BEST OF MY PROFESSIONAL KNOWLEDGE. THE STRUCTURAL DESIGN COMPLIES WITH THE APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE AND ALL DADE COUNTY APPLICABLE CODES. MEANS AND METHODS OF CONSTRUCTION AND SAFETY PRECAUTION ARE THE RESPONSIBILITIES OF THE CONTRACTOR THE CONTRACTOR IS TO BE RESPONSIBLE FOR HIS OR HERS EMPLOYEE'S NEGLIGENT ACTS, ERRORS, OR OMISSIONS. ZONING INFORMATION: ADDRESS: 7103 SW 60th AVE. LOT AREA = 10,080 SF. EXIST. A/C AREA = 1,160 SF. NEW A/C AREA = 1,321 SF. TOTAL A/C AREA = 2,481 SF. EXIST. TERRACE = 282 SF. OTHER GONG. DECKS = 50 SF. POOL AREA = 1,213 SF. NAME PERMITTED PROVIDED MAX. BLDG. COVERAGE 3096 3,024 S.F. (2 96) 2,836 SF. 1 PE=RVIOUS AREA F405%1. 6,048 SF. MIN. 60.0696 6,054 SF. IMPERVIOUS AREA 4,032 SF. MAX 39.9490 4,026 SF. SET BACKS Cn FRONT = 25' -0' = 3135, SIDE = 7' -6" = i' -6' SIDE = 7' -6” = i' -6' REAR 25' -0' = 21' -1' 4' SAN��s'/FT -� FCO NEW U.G. ELECT. SERVICE 2 T , «; 12' e DIAGONAL LINES DENOTE PROPOSED ADDITION P P ELEV. DOTTED AREA DENOTES PROPOSED I NEW CONG. FLAT ROOF / N 28' -1" NO SLAB ON GRADE 1 BELOW ROOF I EXIST. 4'0 OAK TREE TO REMAIN t I I t � N Ex►ST. POOL 140.00' (M&R) PUMP LEGAL DESCRIPTION: LOT -f BLOCK 2, OF PINECREST VILLAS SUBDIVISION, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK No. 41 AT PAGE 51 TO THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. � <a 21' -i" 45 C' k? # ( [ GENERAL NOTES: •'q +� 8a 1.- All wood in contact with masonry or concrete shall be pressure treated. 2.- Truss manufacturer shall submit shop drawings, or design and layout (sealed by Registered Engineer) to Engineer / Architect for approval prior to fabrication 3.- Hvac Subcontractor shall submit shop drawings, or design and layout (Sealed by Registered Engineer) to Architect / Engineer for approval prior to fabrication 4.- All work to be in full strict accordance and compliance with all codes and agencies having jurisdiction. 5- Written dimensions shall take precedence over scaled dimensions. 6.- Contractor shall thoroughly familiarize with drawings and scope of work prior to commencing work All dimensions Shall be field verified and the Architect shall be notified prior to commencing any work of any discrepancies between prepared drawings and field condition. 1- All wood bearing partitions to be one hour fire rated construction. 8.- Contractor shall stake out in the field all underground utilities known or encounter before to beginning excavation. 9.- Contractor shall coordinate all - trades before placing concrete. 10.- All finished materials shall be class "C' min. Flame spread. U.- Partitions to run from floor to underside of slabs, joists or trusses and to consist of wood studs at 1Go' o.c. with 112" gypsum wallboard both sides U.O.N. *eo 12.- Complete all bath wall,wallboard behind sinks, lavatories, bathtub „ -oge showers, water closets and bidets to be water resistance type s.1 13.- Contractor shall coordinate thickness of partitions to accommodate mechanical work- 14.- Lumber Used for studs in interior nonbearing partitions shall be of a stress grade not less than 228 P.S.I. nominal extreme fiber stress in bending. 15.- Contractor Shall provide continuos caulk and sealant around all exterior openings to prevent water penetration and air leakage in accordance with F.B.C. 16.- General Contrac'�or shall verify with 'Flood Control Department' in Dade County before starting construction. 1*1.- If any discrepancies are found, Stop working immediately and notify owner or Architect. EXIST. 6' H.__1 I WD. FENCE r EXIST. POWER POLE EXIST. AERIAL ELECT. SERV. TO BE REMOVED 110[C[ AL 1ASpE FOR TI/I O ate) of SOU &P1., 5� ltyG � M, M_,' HISTORY OF DRAWING ISSUED DESCRIPTION DATE OF ISSUED 0 PROGRESS PERMIT Q CONSTRUCTION REVISION BY 1107-28-10 0 LL Q Z OWJ U. QW� U) �0Uj Cn W--)Q Z U) 0�3: W U) U) O, O N a- 0 of CL d qt V_ T_ 04 Z M o Z U_ U Z Q Q J 04 CL (6 rn i co N 'r O W W M D to U w ° W Q M OD co In co U � 0 Q F_ Z W 0 11 t 00 Ct W .'X)rl�y ;. .< ❑$ rJF : - I-- LL gip: DATE 02 -19-10 SCALE AS NOTED DRAWING Y.T. JOB ~ SHEET A-1 OF SHEETS