13-189-005
ELECTRICAL LEGEND (USE THOSE THAT APPLY) $ 120/277 V„ 20 AMP,, SINGLE POLE LIGHT SWITCH. $3 120/277 V., 20 AMP,, THREE WAY SWITCH. $D 120/277 V., 20 AMP,, DIMMER SWITCH $4 120/277 V., 20 AMP„ FOUR WAY SWITCH. -{�- SURFACE /PENDANT MOUNTED LIGHT FIXTURE, 75W MAX. 2 WALL MOUNTED FIXTURE, 75W MAX. O RECESSED (HI -HAT) LIGHT FIXTURE, 75W MAX. WALL MOUNTED OUTDOOR FIXTURE, 10OW MAX. Q GARAGE DOOR OPERATOR (D J -BOX FOR SURFACE MOUNTED CEILING FAN TO BE PROVIDED BY FUTURE OWNER. © ELECTRICAL PANEL DISCONNECT SWITCH. "2" INDICATES NUMBER OF POLES; A-0 [3j "60" = FRAME SIZE; "NF" = NO FUSES, AND "F " DENOTES FUSE 2 F SIZE AS RECOMMENDED BY EQUIPMENT MANUFACTURER, EF EXHAUST FAN OR GARBAGE DISPOSAL 250V SPECIAL PURPOSE RECEPTACLE ® FLOOR MOUNTED 250V SPECIAL PURPOSE RECEPTACLE 20 A„ 120., V., DUPLEX RECEPTACLE, GROUNDING TYPE, U.O,N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. (p 20A, 120V SINGLE RECEPTACLE 20A, 120V GFI DUPLEX RECEPTACLE 20A, 120V SPLIT WIRED RECEPTACLE O 20A, 120V FLOOR MOUNTED DUPLEX RECEPTACLE 20A, 120V GFI DUPLEX RECEPTACLE W/ COVER PLATE. RECESSED 20 A., 120., V., DUPLEX RECEPTACLE, GROUNDING TYPE, © CEILING OR WALL MOUNTED JUNCTION BOX, SU SINGLE STATION SMOKE DETECTOR W /BATTERY BACKUP 120V CARBON MONOXIDE ALARM W /BATTERY BACKUP, KIDDE 900 -012 OR EQUAL. INTERCONNECT WITH HOUSE SINGLE STATION SMOKE DETECTORS = TELEPHONE OUTLET ® +18" A.F.F. OR AS DIRECTED BY ARCHITECT. (J. BOX W/3/4" EMPTY CONDUIT TO CEILING SPACE). PROVIDE PPULL STRING CABLE TV OUTLET +[] MOMENTARY PUSH BUTTON AT 42" A.F.F. ALARM SYSTEM KEYPAD KP ALARM KEYPAD $ 2 30A/2P SWITCH FOR WATER HEATER ELECTRIC METER TWO HEADS OUTDOOR SECURITY LIGHT. 30OW MAX EACH FIXTURE. CONTROLLED BY MOTION SENSOR /PHOTOCELL AND AN OVERRIDE SWITCH INSIDE THE HOUSE. 'N' OR 'NO LABELED' -NEW 'E' OR 'EX' - EXISTING R - RELOCATED VP -VAPOR PROOF T -R - TAMPER - RESISTANT NOTES: 1.- ALL LIGHT SWITCHES ARE TO BE INSTALLED AT 48" A.F.F. 2.- ALL ELECTRICAL, TELEPHONE /DATA AND TV OUTLETS TO BE INSTALLED AT 18" A.F.F., UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATION, COLOR AND STYLE WITH OWNER /ARCH, ALL LIGHTING FIXTURES SELECTED BY THE OWNER 0 0 SITE PLAN 3/32„ = V-0" EXISTING WOOD DECK TO EXISTING LIGHTS A -1 EXISTING I ' LIVING NEW I ISTING ROOM B, THROOM I I g jfHROOM 1-17 -17 TO N f REMAIN A -17 E I I I Ar 16,18 II AR / II A -17 --" "- NEW StACK48LE WASHER AND DRYER I I I I I A -17 I _ I I EXCEPT WHERE OTHERWISE NOTED, ALL ELECTRICAL DEVICES LABELED AS EXISTING 'E' OR RELOCATED 'R' TO REMAIN CONNECTED TO EXISTING CIRCUITS. FIELD VERIFY DURING CONSTRUCTION. EXCEPT WHERE NOTED FOR CLARIFICATION PURPOSES, EXISTING NOT SHOWN RECEPTACLES TO REMAIN CONNECTED TO CORRESPONDING EXISTING CIRCUITS. EXCEPT FOR FIXED IN PLACE EQUIPMENT, ALL 120V, 15A AND 20A RECEPTACLES TO BE OF THE TAMPER - RESISTANT TYPE, AS PER NEC ARTICLE 406.11 ELECTRICAL PLAN 1/4" = 1' -0" EXISTING RESIDENCE I r I 1�1... D o, U =r , VJ LO I V I r- d City of South Miami Building Dept. 6130 Sunset Drive South Miami, FL 33143 '.• ENSF'• 52192 -13 AS ? O •, OP 4c V//e LEONARDO NAVEIRAS, INC. "CONSULTING ENGINEERS" Leonardo Navelras P.M. CA# 25830 Julio C. Vidal P.E. PE# 52792 1918 Harrison St. # 207 Hollywood, FL 33020 Phone: 954 -270 -4822 Fax: 954 -241 -6850 E-mail. hvacieo@aol.com l'HESE DESIGNS AND DRAWINGS ARE THE COPYRIGHTED PROPERTY OF CARMEN L. - C1JERRERO-1- R9HITECT, -0-A- 9ND MAY NOT BE F PRODUOED, 07,' DISCLOSED T5 OTHERS WITHOUT- WRITTEN CONSENT OF THE I ARCHITECT. _ THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS OF THE JOBS AND BE RESPONSIBLE FOR THE SAME, REPORTING ANY DISCREPANCIES TO THE ARCHITECT BEFORE COMMENCING WORK. DRAWINGS NOT 70 BE SCALED. I• j ►° z V �- C a I„j L M J ¢ N 3 N W c / N Z ¢ LU I• V NN LJ� COMMISSION NUMBER BID SET — PERMIT SET — DRAWN BY: LNI DATE: FEB 09, 2013 REVISIONS: U w o= L U w� 211-Q j ,n d Lj L J ( Z CD ww :�i 0:� as 0 J E -1 PROPOSED ELECTRICAL PLAN