13-706-018Z
M
CL
In
CL
CL
0
C13
0
ct!
N
ci
U)
Z
CU
0
Senues 15M2
Water Hammer Arrestors
VENT PIPE
Sizes: 1/2" - 111 (15-25mm)
IN WALL
What is Water Hammer?
The noise from banging pipes is caused by shocks of high speed
PLATED ESCUTCHEON
viater flowing in the piping system when a fixture is suddenly
closed. Sudden stoppage of the Water (a non - compress Ue
liquid) Bowing at a given pressure and velocity causes a surge or
spike of pressure and is called Water hammer. When this occurs,
2' X 1 114' LAVATORY OR
a pressure wave travels back through the piping until it Chris a
point of relief,
CLEAN OUT TEE
Dishwashers, clothes washers, fast closing positive shutoff valves
OT' TAP IN WALL
incorporated in the system all contribute to creating water shock
which Is not oriiy annoying but damaging to pipes and appli-
ances. The Watts Series 15M2 incorporates a pre - charged,
permanent sealed air chamber to absorb the shock. The sealed
EXTENSION
chamber prevents the loss of air to the water and Insures long
MINIMUM 2' WASTE
and trouble-frea life.
im
Features
NPT solid hex brass adapter or solder end connection
Pressure - Temperature
for easy installation
Operating Pressure: Designed to operate on all domestic and
*Approved for installation with no access panel requ?ed
commercial lines @ 150psl (10.6 bar) working pressure,
• May be installed In new or existing plumbing Systems with a
Temperature Range: 33 °F to 180 °F (0.5 °C to 820C).
standard pipe tee vertically, horizontally or at any angle
• PDI Listed (PDI WH201)
Materials
• Maintenance free - piston is the only moving part
Body; Copper tubing
*Air pre-load is 60psi (4.2 bar)
Rston: Polypropylene
*Factory air charged and permanently sealed
Adapter: Brass
Standards
NO (9 ft
Standard. Ustecl by AMC, ASSE 1010 approved, ANSI
A112.26.11M approved, PDI WH201 approved and certified.
WATER HA MMER ARRESTOR DETAIL
NOT TO SCALE
A
Series 009
Reduced Pressure Zone Assemblies EA
Sizes: 1/4" - 3" (8 - 80mm) VQ
Series OD9 Reduced Pressure Zone Assemblies are designed
to protect potable water supplies in accordance With national
plumbing codes and water authority requirements. This series
can be used in a variety of installations, including the preven- Ih" (1 5mm) 009QT
tion of health hazard cross connections in piping systerns or
for containment at the service line entrance.
This series features two in-line, independent check valves,
captured springs and replaceable check seats with art inter-
mediate relief valve. Its compact modular design facilitates
easy maintenance and assembly access. Sizes 1/4" -- V
(8 - 25mm) shutoffs have lee handles.
Features 2" (50mm) 0091iiA2QTHC
• Single access cover and modular check construction
for ease of maintenance Test Cock No. 3 Test Cock 110, 4
• Top entry - all internals immediately accessible Ball Type
• Captured springs for safe maintenance Test Cocks
• Internal relief valve for reduced installation clearances Test Cock
*Replaceable seats for economical repair Na 2
• Bronze body construction for durability V4` - 2* (8 - 50mm)
4- Second
• Fused epoxy coated cast iron body 2Vzand 3'(65 and 80mm) First Check : " Check
Module
Module
-- • Ball valve test cocks screwdriver slotted 'W Assembly •
- Z (8 - 50rnm) Assembly
• Large body passages provides low pressure drop
.7K I
• Compact, space saving design
• No special tools required for servicing
R.P. Zone
Specifications Relief Valve Assembly Water Outlet
A Reduced Pressure Zone Assembly shall be installed at
each potential health hazard location to prevent backilow due
to backsiphonage andfor backpressure. The assembly shall
consist of an internal pressure differential relief valve located N'W.Avallab e ,_
in a zone k2etwe
en two positive seating chock modules with
Watt,6B6i 1fTSUI16t&d Didicsufres.'_
captured springs and silicone seat discs. Seats and seat
Fbirmoirejnormatiiron�serr forliferature S;WB�
discs shall be replaceable in both check modules and the
relief valve. There shall be no threads or screws in the Water-
way exposed to line fluids. Service of all internal components IMPORTAAM 1JVQb7RE liM COVERIOGAUrHORITIES
shall be through a single access cover secured with stainless FOR LOG4 AISTALLAVON REWREMENTS
steel bolts. The assembly shall atso include tvirc, resilient Seat-
ed isolation valves, four resilient seated test cocks and an air
gap drain fitting. The assembly shall meet the requirements
of. USC Manual Bill Editiont; ASSE Sid, 1013; AWWA Sid.
0511; CSA B64.4. 'Shall be a Watts Regulator Co, Series 009,
tDoes not indicate approval status. Refer to Page 2 for approved
51Z85 & models.
ytm pirridua specificatiaris uj U.S. aawxy unit and man anrappitzrielite and am prrykim 13ridenlra calf re, predsorreawwratts,
cul rater notice and WMA kxwinli any aVigatm to rmko such changes aid irriodiicabors onwalls W&rds pmimsfy orsutsawen0y W 'WWATMJ
PLUMBING SYSTEM BACKFLOW PREVENTER DETAIL
NOT TO SCALE
=4=
PROVIDE ANCHORS AND SUPPORT FOR
HEATER UNIT AS PER MANUFACTURER'S
SPECIFICATIONS
RIGID OR FLEXIBLE COPPER
PLUMBING PIPE AND CONNECTIONS
AS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
QUARTER TURN
SHUT-OFF VALVE
120 OR 240 VOLT POWER
SUPPLY CONNECTION POINT
(SEE SPECIFICATIONS)
NOTES:
1.) FOLLOW MANUFACTURER INSTALLATION INSTRUCTIONS.
2.) PROTECT WATER HEATER FROM EXPOSURE TO DAMP OR HUMID CONDITIONS.
3.) INSTALL WATER HEATER IN CONFORMANCE WITH THE CURRENT NATIONAL ELECTRIC
CODE AND ALL APPLICABLE PROVISIONS OF THE 2010 FLORIDA BUILDING CODE.
TANKLESS WATER HEATER DETAIL
NOT TO SCALE
MAX
STAN TOP OF
STANDARD MN SPOUT SPOUT
DRINKING LOCATION
FOUNTAIN #2
"HANDICAPPED
DRINKING ',D
FOUNTAIN #1 X
a
�
Z m
EQUIPMENT all M
PERMITTED WN
IN THIS I
AREA S19E VIEW FRONT VIEW
6j 11"
FiNiswx,
Ax MIN FLOOR
25" MAX
I Ir'MIN
NOTE:
THIS DETAIL ILLUSTRATES THE MINIMUM FIXTURE CLEARANCES
REQUIRED BY 12012 F.A.C.B.C.' SECTION 307 * 602. SEE FLOOR
PLAN FOR EXACT FIXTURE CONFIGURATION,
F.A.C.B.C. 211 - DRINKING FOUNTAINS
211.1 GENERAL. WHERE DRINKING FOUNTAINS ARE PROVIDED ON AN EXTERIOR SITE,
ON A FLOOR, OR WITHIN A SECURED AREA THEY SHALL BE PROVIDED IN
ACCORDANCE WITH 211. (EXCEPTION: IN DETENTION OR CORRECTIONAL FACILITIES)
211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE
PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6 AND
ONE DRINKING FOUNTAIN SHALL COMPLY WITH 6021.
EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES WITH 602.1 THROUGH
6M.6 AND 6M.7, IT SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO
SEPARATE DRINKING FOUNTAINS.
211.3 MORE THAN MINIMUM NUMBER, WHERE MORE THAN THE MINIMUM NUMBER OF
DRINKING FOUNTAINS SPECIFIED IN 211.2 ARE PROVIDED, 50 PERCENT OF THE TOTAL
NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH 602.1 THROUGH
602.6, AND 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED
WALL COMPLY WITH 602.7.
EXCEPTION: WHERE 50 PERCENT OF THE DRINKING FOUNTAINS YIELDS A FRACTION,
50 PERCENT SHALL BE PERMITTED TO BE ROUNDED UP OR DOWN PROVIDED THAT
THE TOTAL NUMBER OF DRINKING FOUNTAINS COMPLYING WITH 211 EQUALS 100
PERCENT OF DRINKING FOUNTAINS.
HIGH-LOW "HANDICAPPED"
DRINKING FOUNTAIN DETAIL
NOT TO SCALE
WATER SHUT
OFF VALVES
CLOTHES WASHER
WALL BOX
1/2' COMBINATION
SWEAT CONNECTION
DRAIN LINE
------ . . . . .
ACCESS PANEL FIN161EI
WATER HAMMER FLOOR LINE
ARRESTOR
-N,n . V .,q M
9%: V%: V. V%-.. A. V
CLOTHES WASHER WALL BOX DETAIL
NOT TO SCALE
Series 7
Dual Check Valves
7 Sizes: 1h" - 11/4f1 (15 - 32mm)
7C Sizes; 3/a" (1 Omm)
Series 7 Dual Check Wives are designed for non-health
hazard residential water system containment and continuous
pressure applications, such as the drinking water supply
service entrance or individual outlets. series 7 uses two
compact replaceable check modules and is installed imme-
diately downstream of the residential water meter.
Features
• Can be installed vertically or horizontally
• Available with combination of inlelloullet sizes, types or
thread and end connection including retrofit compression
fittings and hose connections
• Can be installed in many piping configurations and with a
wide range of meter horns, copper setters and meter boxes
• 7C, chrome - nickel plated brass dual check for in-line
continuous pressure application
Specifications
The dual check backliow preventer shall meet the domestic
requirements of MJSVASSE Standard 1024, and bear the
seat of approval. It shalt be bronze - bodied and include not
less than one union, with the union nut drilled to accept a
tamper-proofing lock wire. A brass identification tag indicat-
ing chrection of flow shall be securely attached to the verve
body by corraskin•resislart mechanical fasteners. The duel
check shalt be Watts Regulator Company Series 7, (Please
select the model best suited to your application.)
Pressure - Temperature
Temperature Range: 3TF - 180'F (OSC -82°C) continuous
Maximum working Pressure; 150psi (10.3 bar)
Approvals
G @0 0
1024 '0�,
D* ML 0 CFE-K
VA
". iri 1: IrleNpA Cw"'tlys - T M'WAft Ord"in!) Dw� SIZE3 Wai*,
_jypoG�hk; T rdv3s ( min
Unirin U convctkm ayaflabla on all iNcteurmt to aW sizm
' When ordering Series 7 Varies with Meter Thead
Connections, be sure to order connection size one size
larger than meter thread. Examples:
Meter Size Order
1,5' 0 5mm) and 14' (1 6mm) 34- (20mm)
I
W (16mm) and 1/4' (20mm) 1" 25mmp
1, (25mm) VA' (32mm)
'Ar V111d i4r.11.1,M k, LIS =Uy -h at xvIrk �.Mmaln� W M pw&d V Ft4l�. V4- Fol proke VI WA7 W I
UTILITY CENTER BACKFLOW PREVENTER DETAIL
NOT TO SCALE
FAUCET; SEE ----
'PLUMBING FIXTURE
SCHEDULE'
TOP OF
LAVATORY
1/4" TURN
FIXTURE STOF
CHROME FLAT
ESCUTCHEON
FINISHED FLOOR
FFSET
TASTE
IVC TRAP
PARALLEL
TO WALL
NOTE: SEE 'HANDICAPPED" TOILET ROOM DETAIL 5/P-4
FOR ADDITIONAL LAVATORY REQUIREMENTS.
"HANDICAPPED" LAVATORY DETAIL
NOT TO SCALE
1 1/4" PVC "P-TRAP FOR LINE OF DRYWALL
LAVATORIES OR 1 1/2' PVC PARTITION: SEE
'P-TRAP" FOR SINKS 'LAYOUT PLAN'
FOR WALL DETAILS
NOTE. SEE DETAIL 7/P-5 FOR 'HANDICAPPED LAVATORY'
SPECIFIC 'P-TRAP' REQUIREMENTS.
LAV - SINK DRAIN DETAIL
NOT TO SCALE
FAUCET -
LAVATORY
COUNTERTOP
AAIN-
AIR ADMITTANCE VALVE SHALL
BE LOCATED A MINIMUM OF 4"
ABOVE THE HORIZONTAL BRANCH
DRAIN LINE IN A VERTICAL
UPRIGHT POSITION
T• °•°4...... PRIG
FAIR ADMITTANCE VALVES
THE INSTALLATION OF AIR ADMITTANCE
A
VALVES SHALL COMPLY WITH FLORIDA
BUILDING CODE-PLUMBING SECTION 917.
AIR ADMITTANCE VALVE DETAIL
NOT TO SCALE
MIN. 2' VENT
VENT PIPE
-V
IN WALL
POLISHED CHROME
CLEAN OUT PLUG
PLATED ESCUTCHEON
6' DIAMETER
2' X 1 114' LAVATORY OR
9 " X 1 1/2' SINK SANITARY
CLEAN OUT TEE
II
OT' TAP IN WALL
SET SCREW
PVC WALL
EXTENSION
MINIMUM 2' WASTE
NIPPLE
FINISHED DRYWALL
LINE IN WALL
1 1/4" PVC "P-TRAP FOR LINE OF DRYWALL
LAVATORIES OR 1 1/2' PVC PARTITION: SEE
'P-TRAP" FOR SINKS 'LAYOUT PLAN'
FOR WALL DETAILS
NOTE. SEE DETAIL 7/P-5 FOR 'HANDICAPPED LAVATORY'
SPECIFIC 'P-TRAP' REQUIREMENTS.
LAV - SINK DRAIN DETAIL
NOT TO SCALE
FAUCET -
LAVATORY
COUNTERTOP
AAIN-
AIR ADMITTANCE VALVE SHALL
BE LOCATED A MINIMUM OF 4"
ABOVE THE HORIZONTAL BRANCH
DRAIN LINE IN A VERTICAL
UPRIGHT POSITION
T• °•°4...... PRIG
FAIR ADMITTANCE VALVES
THE INSTALLATION OF AIR ADMITTANCE
A
VALVES SHALL COMPLY WITH FLORIDA
BUILDING CODE-PLUMBING SECTION 917.
AIR ADMITTANCE VALVE DETAIL
NOT TO SCALE
WALL CLEAN OUT DETAIL
NOT TO SCALE
BAR JOIST OR
BEAM FLANGE
ANGLE BRACKET
LOCKING NUT
BEAM / FLANGE CLAMP
DIAMETER THREADED
SUPPORT ROD SEE
'PLUMBING NOTES'
FOR MAXIMUM SPACING
CLAMP AT NOTE
BEAM / JOIST FLANGE SEE STEVEN B. SCHWORTZ, ARCHITECT
FOR APPROVED ALTERNATE SUPPORTS.
PIPE SUPPORT BRACKET DETAIL
NOT TO SCALE
LOCKING NUT
SUPPORT NUT
PIPE RING: SEE -
"PLUMBING NOTES"
PIPE INSULATION
WITH INTEGRAL
VAPOR BARRIER
PIPE, SEE -
PLUMBING PLANS
MINIMUM 4' LONG
SUPPORT SADDLE
SINGLE HORIZONTAL RUN
CONDENSATE LINE
WITH INSULATION
3/8" DIAMETER SUPPORT
ROD TO STRUCTURE ABOVE
SEE 'PLUMBING NOTES'
FOR MAXIMUM SPACING
SINGLE HORIZONTAL RUN
STEEL PIPE, COPPER PIPE
PVC PIPE
SPREADER BA
HEAVY DUTY
"CLEVIS" HANG
SINGLE HORIZONTAL RUN
SANITARY PIPE
PROVIDE 8' MINIMUM 1/2" DIAMETER HANGER
INSULATION SHIELD AND RODS WITH 36' MAXIMUM
INSERT FOR ALL PIPING SPACING BETWEEN
F-AC34 CHANNEL
PIPE
%
BAND = TRAPEZE HANGER FOR UP
TO 1,000 LB. UNIFORM LOAD:
} _' 1 5/5" GAUGE CHANNEL OR
2' x 2" x 1/4' ANGLE
I' MAXIMUM LOCKING NUT
MULTIPLE HORIZONTAL RUNS
ANY PIPE TYPE
TRAPEZE SIDE VIEW
SUSPENDED PIPE SUPPORT DETAILS
SCALE: 3/4" m l' - O"
>1
M co v
V
MM N
�V: 0
X
ic low .
a U.
4j 0
c
0
�� �mo
0
Z
•
COPYRIGHT 201
STEVEN B. SCHWORTZ
ARCHITECT, P.A.
ALL RIGHTS RESERVED
NO PART OF THESE PLANS MAY BE
REPRODUCED OR USED IN ANY WAY
OR FORM WITHOUT THE EXPRESS
WRITTEN CONSENT OF
STEVEN B, SCHWORTZ
ARCHITECT, P.A.
PLANS MUST BE RETURNED
UPON REQUEST.
•
Uj 0
ft
OWE
O CIO
LL 0 en M
<
us LU LU
Ozo
Uj U_
0 ;>
> C)
0 LU Z
cl)ILL.
LL. .
0
• C0
Z
W
0
mxonww-
COM: 2012-17
REVISIONS:
AUDI
ARCHITECTURE
DATE: 02-25.2013
BY: S.B.S.
TOTAL NUMBER OF
DRAWINGS IN SET: 21
P�5
OF : 6
POUND GALVANIZED
VENT PIPE
-V
STEEL SLEEVE
CLEAN OUT PLUG
6' DIAMETER
CHROME FINISH
ACCESS COVER
CLEAN OUT TEE
II
SET SCREW
FINISHED DRYWALL
SANITARY PIPE
WALL CLEAN OUT DETAIL
NOT TO SCALE
BAR JOIST OR
BEAM FLANGE
ANGLE BRACKET
LOCKING NUT
BEAM / FLANGE CLAMP
DIAMETER THREADED
SUPPORT ROD SEE
'PLUMBING NOTES'
FOR MAXIMUM SPACING
CLAMP AT NOTE
BEAM / JOIST FLANGE SEE STEVEN B. SCHWORTZ, ARCHITECT
FOR APPROVED ALTERNATE SUPPORTS.
PIPE SUPPORT BRACKET DETAIL
NOT TO SCALE
LOCKING NUT
SUPPORT NUT
PIPE RING: SEE -
"PLUMBING NOTES"
PIPE INSULATION
WITH INTEGRAL
VAPOR BARRIER
PIPE, SEE -
PLUMBING PLANS
MINIMUM 4' LONG
SUPPORT SADDLE
SINGLE HORIZONTAL RUN
CONDENSATE LINE
WITH INSULATION
3/8" DIAMETER SUPPORT
ROD TO STRUCTURE ABOVE
SEE 'PLUMBING NOTES'
FOR MAXIMUM SPACING
SINGLE HORIZONTAL RUN
STEEL PIPE, COPPER PIPE
PVC PIPE
SPREADER BA
HEAVY DUTY
"CLEVIS" HANG
SINGLE HORIZONTAL RUN
SANITARY PIPE
PROVIDE 8' MINIMUM 1/2" DIAMETER HANGER
INSULATION SHIELD AND RODS WITH 36' MAXIMUM
INSERT FOR ALL PIPING SPACING BETWEEN
F-AC34 CHANNEL
PIPE
%
BAND = TRAPEZE HANGER FOR UP
TO 1,000 LB. UNIFORM LOAD:
} _' 1 5/5" GAUGE CHANNEL OR
2' x 2" x 1/4' ANGLE
I' MAXIMUM LOCKING NUT
MULTIPLE HORIZONTAL RUNS
ANY PIPE TYPE
TRAPEZE SIDE VIEW
SUSPENDED PIPE SUPPORT DETAILS
SCALE: 3/4" m l' - O"
>1
M co v
V
MM N
�V: 0
X
ic low .
a U.
4j 0
c
0
�� �mo
0
Z
•
COPYRIGHT 201
STEVEN B. SCHWORTZ
ARCHITECT, P.A.
ALL RIGHTS RESERVED
NO PART OF THESE PLANS MAY BE
REPRODUCED OR USED IN ANY WAY
OR FORM WITHOUT THE EXPRESS
WRITTEN CONSENT OF
STEVEN B, SCHWORTZ
ARCHITECT, P.A.
PLANS MUST BE RETURNED
UPON REQUEST.
•
Uj 0
ft
OWE
O CIO
LL 0 en M
<
us LU LU
Ozo
Uj U_
0 ;>
> C)
0 LU Z
cl)ILL.
LL. .
0
• C0
Z
W
0
mxonww-
COM: 2012-17
REVISIONS:
AUDI
ARCHITECTURE
DATE: 02-25.2013
BY: S.B.S.
TOTAL NUMBER OF
DRAWINGS IN SET: 21
P�5
OF : 6