13-706-015uv U'• Z CW3 Q (b Z m CL cu Ii a CL Z a 0 0 N N m m K`. a W t, 0CV r � �Q s= o rL CL a a SEPARATE SUB - PERMIT REQUIRED FOR PLUMBING WORK • t -- W- - - -W -- COLD WATER LINE – A– ----- – A--• -, COMPRESSED AIRLINE (1/2 ") — N =o N20 — NITROUS OXIDE LINE (3/8 ") o a OXYGEN LINE (1/2') NOTES: 1.) SEE PLUMBING PLAN AND PIPING DIAGRAMS FOR PIPE SIZES NOT INDICATED ABOVE. 2.) SEE MANUFACTURER'S SPECIFICATIONS FOR FINAL CONNECTION SIZES AND VALVE REQUIREMENTS. M H :5 AIR O UTLET IN —• BACKSPLASH. SEE OWNER FOR EXACT LOCATION AND APPROVAL SINK W/ PLASTER "TANKLEES" WATER - A. 1` HEATER, SEE U. PLUMBING FIXTURE SCHEDULE n ry 10 TANKLESS p_5 WATER HEATER 3/4" WASHER IN FITTINGS TYPE ROOM FIXTURE MFG MODEL DESCRIPTION REMARK MFG. MODEL DESCRIPTION STEVEN B. SCHWORTZ ARCHITECT, P.A. PLANS MUST BE RETURNED UPON REQUEST. ® TOILET WATERCLOSET TOTO • r M DRAKE - ADA CST744SL 1.6 GAL - ELONGATED - TANK TYPE + SEAT HANDICAPPED TOTO SS114 SOFTCLOSE SEAT - - ® TOILET / HYG. LAVATORY AMERICAN STD. AQUALYN #0476.028 CHINA; SELF - RIMMING; 4" CENTERS - IN COUNTER STANDARD DELTA 520 -WFHDF FAUCET WITH POP -UP DRAIN ^ © EXAM LAVATORY ELKAY BCR -15 2- HOLES; STAINLESS STEEL DELTA 711 -WFHDF FAUCET - SWING GOOSENECK' , �D STERILIZATION SINK ELKAY DATE : 02 -25 -2013 LRQ -1418 4- HOLES; 1- COMPARTMENT; STAINLESS STEEL P�2 DELTA 174 -WF FAUCET - SWING SPOUT: SPRAYER + SOAP �E LAB SINK ELKAY LRQ -1418 3- HOLES: STAINLESS STEEL DELTA 172 -WF FAUCET - SWING SPOUT + SPRAYER 1,) THE PLUMBING FIXTURE SCHEDULE ESTABLISHES EQUIPMENT 2.) THE PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL ALL FIXTURES, 4.) THE GENERAL CONTRACTOR SHALL VERIFY THE REQUIREMENTS STANDARDS FOR BIDDING AND CONSTRUCTION UNLESS CHANGED BY FITTINGS AND COMPONENTS REQUIRED FOR A COMPLETE JOB, FOR ALL OWNER SUPPLIED FIXTURES AND FITTINGS. AGREEMENT WITH THE OWNER. SEE OWNER FOR APPROVAL OF ALL 3.) FIXTURES THAT ARE A PART OF OWNER SUPPLIED EQUIPMENT SHALL BE 5.) FIXTURE MANUFACTURER AND COLOR SELECTIONS SHALL BE MADE FIXTURES PRIOR TO ORDERING. INSTALLED BY THE PLUMBER, BY THE OWNER . SEPARATE SUB - PERMIT REQUIRED FOR PLUMBING WORK • t -- W- - - -W -- COLD WATER LINE – A– ----- – A--• -, COMPRESSED AIRLINE (1/2 ") — N =o N20 — NITROUS OXIDE LINE (3/8 ") o a OXYGEN LINE (1/2') NOTES: 1.) SEE PLUMBING PLAN AND PIPING DIAGRAMS FOR PIPE SIZES NOT INDICATED ABOVE. 2.) SEE MANUFACTURER'S SPECIFICATIONS FOR FINAL CONNECTION SIZES AND VALVE REQUIREMENTS. M H :5 AIR O UTLET IN —• BACKSPLASH. SEE OWNER FOR EXACT LOCATION AND APPROVAL SINK W/ PLASTER "TANKLEES" WATER - A. 1` HEATER, SEE U. DETAIL 10 TANKLESS p_5 WATER HEATER 3/4" WASHER IN DRYER M.. COMBO CLOTHES WASHER WALL BOX: SEE DETAiI P-5 NOTE: COLD WATER SUPPLY SHALL HE CONNECTED TO WATER SHUT OFF SOLENOID D AREA OF ALL OTHER FIXTURES DETAIL KEY DETAIL t�3� NUMBER X -X DETAIL IS SHOWN ON THIS DRAWING SHEET CATEGORY 3 GAS AND VACUUM SYSTEMS CODE COMPLIANCE FOR THE GAS POWERED DEVICES AND VACUUM SYSTEM ILLUSTRATED HEREIN ARE GOVERNED BY THE 2012 EDITION OF THE "N,F.P.A. 99 HEALTH CARE FACILITIES CODE" FOR "CATEGORY 3' FACILITIES AS DEFINED IN CHAPTER 4. 413: FACILITIES SYSTEMS IN WHICH FAILURE OF SUCH EQUIPMENT IS NOT LIKELY TO CAUSE INJURY TO PATIENTS OR CAREGIVERS, BUT CAN CAUSE PATIENT DISCOMFORT, SHALL BE DESIGNED TO MEET SYSTEM CATEGORY 3 REQUIREMENTS AS DEFINED IN THIS CODE, EXISTING WNDOW - DR'S OFF. i U. 1/21' t f"_ w 3/4" z IN M.. DRINKING Wb--� FOUNTAINS " 01 SHUTOFF VALVES: SEE 'PLUMBING NOTES" 23 EXISTING WINDOW LAV UTILITY CENTERS UTILITY CENTER INSTALLATIONS MAY VARY FROM ROOM TO ROOM, SEE EQUIPMENT MFG`S REP. FOR INDIVIDUAL UTILITY CENTER REQUIREMENTS BEFORE PROCEEDING WITH THIS WORK. CONDENSATE TRAP SEAL FBC- P60q.7 CONDENSATE DRAIN TRAP SEAL: A WATER SUPPLY SHALL BE PROVIDED FOR CLEANING, FLUSHING AND RESEALING THE CONDENSATE TRAP, AND THE TRAP SHALL DISCHARGE THROUGH AN AIR GAP IN ACCORDANCE WITH P6M. CUUM EXHAUST F ROM "CATAGORY -3' VACUUM L BE PIPED TO THE PER N.F.P.A. qq- 5.3.8.3.11 PIPING LAYOUT THE LOCATION AND LAYOUT OF PIPING ON THIS PLAN IS FOR ILLUSTRATION PURPOSES ONLY. VERIFY FIELD CONDITIONS AND SEE EQUIPMENT MANUFACTURER'S REPRESENTATIVE FOR SPECIAL CONSIDERATIONS OR APPLICATIONS. HOT WATER SUPPLY SYSTEM F.B.C. - SECTION P -607 607.1 WHERE REQUIRED. IN OCCUPIED STRUCTURES, NOT WATER SHALL BE SUPPLIED TO ALL PLUMBING FIXTURES AND EQUIPMENT UTILIZED FOR BATHING, WASHING, CULINARY PURPOSES, CLEANSING, LAUNDRY OR BUILDING MAINTENANCE. EXCEPTION: IN NONRESIDENTIAL OCCUPANCIES, HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR BATHING AND WASHING PURPOSES. THE DELIVERY OF COLD WATER ONLY SHALL BE PERMITTED TO BE DELIVERED FROM ALL 14ANDWASWING FACILITIES EXCEPT WHERE HOT WATER IS REQUIRED BY LAW. HEALTH CARE PLUMBING F.B.C. - SECTION P -609 60q.3 HOT WATER. HOT WATER SHALL BE PROVIDED TO SUPPLY ALL OF THE HOSPITAL FIXTURE, KITCHEN AND LAUNDRY REQUIREMENTS, SPECIAL FIXTURES AND EQUIPMENT' SHALL HAVE HOT WATER SUPPLIED AT A TEMPERATURE SPECIFIED BY THE MANUFACTURER. THE MOT WATER SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 607. FINAL CONNECTION NOTE PLUMBING SUB - CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO VACUUM $ COMPRESSOR UNITS, EXISTING WINDOW EXISTING WINDOW WALL Irm 0 HYG #2 CENTER EXAM #2 LAV EXAM #1 3 7i, SUSPENDED WATER LINES: 1 w+1► --- w-- -4a-w -- —w - -W =�—w -- W— SEE DETAIL ��TER P -5 DR NKI GPFOUNTAINS" 1 /r' PIPING: a ` LAV CC f SEE DETAIL 9 SEE PLUMBING WALL P -5 uTaU�TY NOTES" 17 18 E - > -{ UTILITY CENTER _ 'j`t{�i� G�TER ' zv N20 N20 20 . N20 N20 N20 -- -i I J N20 �I o 0 1 O –�-Q o 0 0 ,Q 1-0 — A— ----- — A„_... ----- — A ------ SINK C ' Q STERILE3/4 , � C TOILET E VpIR,A— --- I--- _ ----- —A— A WATER iV _ V �✓A1 f �y OUTLET LAB `�. ` . CLOSET ' E N WATER AIR L 1/2" SOLENOID 3COMP I `- :+;.:: .t EQUIP. WATER HAMMER ARRESTOR: R12 SEE DETAIL LAV EXPOSED PIPING: SEE "PLUMBING NOTES" 22 BUS, OFF. WATER 544UT -OFF SOLENOID AND FILTER: SEE DETAIL —AIR COMPRESSOR: P -4 SEE DETAIL P14 i3: 10 i o z 1/2 ' HYG #1 a „ Q UTILITY CENTER I ! UTIUTY o i BACKFLOW PREVENTER: CENTER SEE DETAIL - P_5 t�o Z TL2 X -RAY CL N20 MANIFOLD 2" COPPER DENTAL AIR COMPRESSOR SUPPLY LINE: TAP INTO FRESH RECEPTION AIR DUCT AS PER 2012 "N,F,P,A. qq- 5.3.7.6.5 r i. i• . ',t s' : i.• .'`' EXISTING SOURCE OF COMPRESSOR 1 TAP INTO EXISTING `'1•. °.t• - t °'``` t L .3'- a'>J, -a' COLD WATER MAIN: ' DQOR ° -, INTAKE AIR" (CATAGORY -3) VERIFY LOCATION : t "- s• IN FIELD t; . I r . •r " ".t. • r : ; i . " E�(iT ��. EXISTING :EXISTING WINDOW" WINDOW: SYSTEh(` ° K -rL'OW •t. HA F' R•. ` . " �icFLflW F�(ENfiE • WA•LK -WAY ", I°REVENTER: • •'�• , •. °.: ;• •:. ",'; R,'i, 't+• k I.�OCAPOR tND,ICC��TED SEE DETAIL :r ` '15'•FOK tCL115TRATfON r ' ' PURPOSES ONLY. 1 P -5 (INSIDE TO INSIDE) 36' -5°' (INSIDE TO INSIDE) 0 Z s ai °o b* v fin Zo �;o 3N PLUMBING PLAN -ABOVE CEILING (WATER- AIR -N20 LINES) SCALE: '1/4" = 11' - O" PROJECT FLOOR AREA = 1,081.67 SQ.FT. NITROUS OXIDE MANIFOLD: SEE DETAIL P -6 tl a (4 d w 0 in z O W 0 W Z rr . Z3 m X 0 u? U. L ►( 0 z L4 M.. t, COPYRIGHT 2013 STEVEN B. SCHWORTZ ARCHITECT, P.A. ALL RIGHTS RESERVED NO PART OF THESE PLANS MAY BE REPRODUCED OR USED IN ANY WAY OR FORM WITHOUT THE EXPRESS WRITTEN CONSENT OF STEVEN B. SCHWORTZ ARCHITECT, P.A. PLANS MUST BE RETURNED UPON REQUEST. • u • r M CI Lu q. in F- r L a oc� us U 4 ` C3 0 W = tx O O Q w j ;:,, J < 0 Lu N co co u,. F-- o�o • co _ r r� z W ac�o�LUUt- COM : 2012 -17 REVISIONS: LI ALIEN ARCHITECTURE DATE : 02 -25 -2013 BY: s.B.s. TOTAL NUMBER OF DRAWINGS IN SET : 21 P�2 OF : 6