Loading...
13-706-009V w O 4 m 0 x v Q N a i w 0 0 z O H u� z 0 E3 ca P 0 N N cu m a Q N co z N Q SS W �Q �o CL CL FLOOR TO CEILING BRACING ml AC? HE R uD; 001 STUD TO STUD BRACING MOUNTING NOTES 1.) INSTALL WOOD BACKING AT THE TIME INTERIOR STUDS ARE SET IN PLACE. 2.) WOOD BACKING SHALL BE ANCHORED AT 74E FLOOR AND CEILING LINE, 3.) SEE MANUFACTURER'S INSTALLATION TEMPLATE FOR COMPLETE INSTALLATION DETAILS FOR THE MODEL SELECTED. PAN/ CEPH X -RAY MOUNTING DETAIL 9 NOT TO SCALE STANDARD 15" 5 Max TOP T _, MIN SPOUT DRINKING LOCATION j SPOUT FOUNTAIN #2 IL 'HANDICAPPED' f ; `'- :r =:=• DRINKING FOUNTAIN #I ,:; . ,' f 1 :o Q! A Pw Z : ;�•': 'et EQUIPMENT rt 8" C4 g M 2 PERMITTED MIN IN THIS o .Ez- r1 $IDE VIEW FRONT VIEW AREA .�1z•fJ.,.,, -r ... �:sr,.-:�:.,..: °t�..... a.c<• •., A�::7::. :ti;t�;,, 61 * 11" FINISHED] AX1 MIN FLOOR 25" AX 17" MIN NOTE: THIS DETAIL ILLUSTRATES THE MINIMUM FIXTURE CLEARANCES REQUIRED BY '2012 F.A.C.B.C." SECTION 307 1 602. SEE FLOOR PLAN FOR EXACT FIXTURE CONFIGURATION. F.A.C.B.C. 211- DRINKING FOUNTAINS 211,1 GENERAL. WHERE DRINKING FOUNTAINS ARE PROVIDED ON AN EXTERIOR SITE, I ON A FLOOR, OR WITHIN A SECURED AREA THEY SHALL BE PROVIDED IN ACCORDANCE WITH 211. (EXCEPTION: IN DETENTION OR CORRECTIONAL FACILITIES) 211.2 MINIMUM NUMBER, NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.7. EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES WITH 602.1 THROUGH 602.6 AND 6021, IT SHALL BE PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING FOUNTAINS. 211.3 MORE THAN MINIMUM NUMBER. WHERE MORE THAN THE MINIMUM NUMBER OF DRINKING FOUNTAINS SPECIFIED IN 211.2 ARE PROVIDED, 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH 602.1 THROUGH 602.6, AND 50 PERCENT OF THE TOTAL NUMBER OF DRINKING FOUNTAINS PROVIDED SHALL COMPLY WITH 602.7. EXCEPTION: WHERE 50 PERCENT OF THE DRINKING FOUNTAINS YIELDS A FRACTION, 50 PERCENT SHALL BE PERMITTED TO BE ROUNDED UP OR DOWN PROVIDED THAT THE TOTAL NUMBER OF DRINKING FOUNTAINS COMPLYING WITH 211 EQUALS 100 PERCENT OF DRINKING FOUNTAINS. HIGH -LOW "HANDICAPPED" DRINKING FOUNTAIN DETAIL NOT TO SCALE A -$ ,1 'STANDARD' "STANDARD" 44 1 SERVICE SERVICE 36 COUNTERTOP COUNTERTOP MINIMUM 'HANDICAPPED" 'HANDICAPPED' 4 SERVICE SERVICE COUNTERTOP COUNTERTOP -- DESKTOP' --- --,- -- ' DRYWALL PARTITION ::Ge: :•;f S,�Y .. ••.'�•' •: :. =.:::n;,'y�c:.`r',.�`••.�r:;; �+ n ' ;�4:': -', ,rte=•, j. i `-- 30'x48" , - PARALLEL ;,• - M X I APPROACH X d AREA KNEE aY. ..:.,' h?ALL'.',r °- •,.,n:.`° r� �L SPACE r LINE i � LINE R ,•?'•,'��i ".:; -• '� �:: ,.� ':,.: x,� p. SECTION ELEVATION SERVICE COUNTERS "HANDICAPPED" SERVICE COUNTER ILLUSTRATED COMPLIES WITH THE 2012 F.A.C.B.C. SECTION 0104.4 AND PARALLEL APPROACH 0104.4.1 FOR PARALLEL APPROACHES. "HANDICAPPED" SERVICE COUNTER DETAIL 7 SCALE: 1/2" — 1' -0" A -$ K CERAMIC WALL TILE: SEE INTERIOR DESIGNER `•',` '• .`': °: `• OR OWNER FOR SELECTION WALL TILE MASTIC SANDED TILE GROUT WITH SEALANT ;; • . 1/2' 'DUROCK' CEMENT BOARD APPLIED PARALLEL OR AT RIGHT ANGLES WITH METAL STUD ' - ': V TYPE "S' DRYWALL SCREWS FRAMING AT S' O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS 5/6' DRYWALL CERAMIC TILE FLOORING: .% SEE INTERIOR DESIGNER % OR OWNER FOR SELECTION CONCRETE "THINSET' SETTING BED FLOOR r 7.4 '':•d• ®:6' <•e•' p :•s d :• d '.e'`.•e•. °.e °:•6• °.p' °:•6•.'.p '" -4'•: e' � °Q "•: e'' :�'•4' °: e': ,,...d••p a z;:..4'•. a ° "• :� -4'•: a �: °4••= e'' •`• °4`•: O .. TILED WALL & FLOOR DETAIL 6 NOT TO SCALE A -S 1344 .. x TOP OF HANDLE .:... _ FIRE EXTINGUISHER SEE FLOOR PLAN FOR LOCATIONS) AND SIZE C4 ed 'LARSEN'S- : =t:::: 0 VERTICAL DUO' I 0 ALUMINUM FIRE EXTINGUISHER C ui ABINET s Z 0 -. . ' LINE.•... _ � ,.F FIFE EXTINGUISHERS 1.) FIRE EXTINGUISHER LOCATIONS SHALL BE COORDINATED WITH AND APPROVED BY THE FIRE MARSHAL. OBTAIN FIRE MARSHAL APPROVALS PRIOR TO ORDERING OR PLACING ANY FIRE EXTINGUISHING EQUIPMENT. 2.) EXTINGUISHER SHALL 14AVE CURRENT DATE AND BE TAGGED BY A LICENSED FIRE EQUIPMENT COMPANY. 3.) THE TRAVEL DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75'4". FIRE EXTINGUISHER MOUNTING DETAIL 5 NOT TO SCALE A -8 SPONGE SILICONE STOP I I FACTORY" PROVIDED I #6 x 5/8 PHSMS DOOR __,,Ol L _ _ _ _ _ _ _ PHILLIPS SCREWS i (TYPICAL) B I I "PEMKO" - 319DS ACOUSTIC SEAL 1 3/4" 15/32 1 ` DOOR - I C4 Ii - -- - - - - -- °- VINYL GASKET I I I 1 1 I I t DOOR ! f 1 I I I B FACTORY PROVIDED #10 x 1 -1/2' FHWS PHILLIPS SCREWS "PEMKO" - 318DV "PEMKO" - 151 D BOTTOM GASKET THRESHOLD EQUIPMENT ROOM SOUNDPROOFING HARDWARE DETAILS 4 _ NOT TO SCALE A -S WOOD OR METAL WALL STUDS. SEE LAYOUT PLAN FOR WALL TYPES. DRYWALL: SEE PLAN FOR THICKNESS LINE OF CABINETS x _ — _ — Z 1 Mu U' p ATTACH CABINETS WITH ----�. Z d, MANUFACTURER APPROVED 0 MOUNTING SCREWS I 0 w I vi MIN. 2'x 4' WOOD BACKING PLATE ^-r" SECURELY FASTENED BETWEEN i STUDS AS REQUIRED Flo". WALL & BASE CABINET BACKING DETAIL 3 SCALE: 3" = 1' -0" �o co 0 co WOOD OR METAL WALL ----- STUDS. SEE LAYOUT PLAN FOR WALL TYPES. WALL TILE OVER MOISTURE RESISTANT (M.R.) DRYWALL 1 1/21# 1 1/2' O.D. STAINLESS 1 (� STEEL GRAB BAR : m m ATTACH GRAB BAR OVER TILE AND GYPSUM BOARD WITH t7 MOUNTING SCREWS SUPPLIED 0 BY MANUFACTURER 0 2'x 6" WOOD BACKING PLATE SECURELY FASTENED BETWEEN STUDS AS REQUIRED GRAB BAR MOUNTING DETAIL 2 SCALE: 3" = 1' -0" A -8 TOILET MIN. TISSUE 42 11__._ DISPENSER MIN. LOCATION ` 1 1 I a a SEAT co Z 71A -ell SIDE ELEVATION f4 12 1 -1/2 "0 GRAB 4AfN, MINIMUM 16 "x24" MAX. - " BAR W/ 1 1/2 36 MIRROR CLEARANCE FROM MIN. W 13 WALL 12" I MIN. fQ � um f ` X 0 p TOP OF 0 u::: d 0 U. M TRA N 0 TRANSFER 0 0 . O - R SIDE :0 x °° z 0 4 0 to 0 g • �"'� w 0 t- FINISHED FLOOR A MIN. 0% M N b :+ 0 _ r ~ C<) FLUSH LEVER ON ALL EXPOSED PIPING T+ TRANSFER SIDE FRONT ELEVATION SHALL BE COVERED Nr. G OF WATER CLOSET a�O--JwUI- 0 z "PEMKO" - 318DV "PEMKO" - 151 D BOTTOM GASKET THRESHOLD EQUIPMENT ROOM SOUNDPROOFING HARDWARE DETAILS 4 _ NOT TO SCALE A -S WOOD OR METAL WALL STUDS. SEE LAYOUT PLAN FOR WALL TYPES. DRYWALL: SEE PLAN FOR THICKNESS LINE OF CABINETS x _ — _ — Z 1 Mu U' p ATTACH CABINETS WITH ----�. Z d, MANUFACTURER APPROVED 0 MOUNTING SCREWS I 0 w I vi MIN. 2'x 4' WOOD BACKING PLATE ^-r" SECURELY FASTENED BETWEEN i STUDS AS REQUIRED Flo". WALL & BASE CABINET BACKING DETAIL 3 SCALE: 3" = 1' -0" �o co 0 co WOOD OR METAL WALL ----- STUDS. SEE LAYOUT PLAN FOR WALL TYPES. WALL TILE OVER MOISTURE RESISTANT (M.R.) DRYWALL 1 1/21# 1 1/2' O.D. STAINLESS 1 (� STEEL GRAB BAR : m m ATTACH GRAB BAR OVER TILE AND GYPSUM BOARD WITH t7 MOUNTING SCREWS SUPPLIED 0 BY MANUFACTURER 0 2'x 6" WOOD BACKING PLATE SECURELY FASTENED BETWEEN STUDS AS REQUIRED GRAB BAR MOUNTING DETAIL 2 SCALE: 3" = 1' -0" A -8 TOILET MIN. TISSUE 42 11__._ DISPENSER MIN. LOCATION ` 1 1 I a a SEAT co Z 71A -ell SIDE ELEVATION f4 12 1 -1/2 "0 GRAB 4AfN, MINIMUM 16 "x24" MAX. - " BAR W/ 1 1/2 36 MIRROR CLEARANCE FROM MIN. W 13 WALL 12" I MIN. - c+a um f O Q Z ocn ui h c �r r ch M TOP OF 0 u::: d 0 A LLJ S EAT TRA N 0 TRANSFER 0 0 . O - R SIDE :0 x °° z 0 4 0 to 0 g 0 i Z N 4C t- FINISHED FLOOR A MIN. 0% M N b :+ 0 _ r ~ C<) FLUSH LEVER ON ALL EXPOSED PIPING T+ TRANSFER SIDE FRONT ELEVATION SHALL BE COVERED OF WATER CLOSET NOTE THIS DETAIL ILLUSTRATES THE MINIMUM FIXTURE CLEARANCES REQUIRED BY THE '2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION' - CHAPTER 6. SEE DRAWING SHEET A -01 FOR CLEAR FLOOR AREAS AND THE FLOOR PLAN FOR EXACT FIXTURE CONFIGURATION. "HANDICAPPED" TOILET ROOM DETAIL SCALE: 318" — 1'- O" A -$ r ke� C;,. •® • C'N • f COPYRIGHT 2013 STEVEN B. SCHWORTZ ARCHITECT, P.A. ALL RIGHTS RESERVED NO PART OF THESE PLANS MAY BE REPRODUCED OR USED IN ANY WAY OR FORM WITHOUT THE EXPRESS WRITTEN CONSENT OF STEVEN B. SCHWORTZ ARCHITECT, P.A, PLANS MUST BE RETURNED UPON REQUEST. CUM : 2012 -17 REVISIONS: AU04 ARCHITECTURE DATE: 02.25 -2018 BY: S.B.S. TOTAL NUMBER OF DRAWINGS IN SET: 21 ► OF : 4 C . • W 13 o c+a um f O Q Z ocn ui h c �r r ch M uLu 04 c� A LLJ Q G O 0 aui _j _ > Q _ 0 > ua Z N 4C LL. LA- O vi C) G1 i Q r ~ C<) z T+ w a�O--JwUI- CUM : 2012 -17 REVISIONS: AU04 ARCHITECTURE DATE: 02.25 -2018 BY: S.B.S. TOTAL NUMBER OF DRAWINGS IN SET: 21 ► OF : 4 C