Loading...
13-706-007CD w V LL ul cs z 14: m 0 C13 o T_ N rl N m ca U) co Z C,J 3CL EXTEND AND ANCHOR SUPPORT LEGS TO STRUCTURE ABOVE ... ... 21x4" 16 -GAUGE GALV. METAL FRAMING AND CROW BRACING. INSTALL ADDITIONAL CROSS BRACES AS REQUIRED TO PROVIDE A MMON FREE SUPPORT. (TYPICAL) lb-GAUGE GALV. METAL STUD SACKING SUPPORT PLATE 17- w LAMINATED DENTAL LIGHT MOUNTING PLATE.. TWO LAYERS OF 2'-0" x 2'-0' x 3/41 EXTERIOR GRADE PLYWOOD INSTALLED FLUSH WITH FINISHED SURFACE OF CEILING. ACOUSTIC TILE OR SEE MANUFACTURER'S MOUNTING DETAILS DRYWALL CEILING- FOR ANCHORS AND ADDITIONAL MOUNTING SEE REFLECTED REQUIREMENTS. (USE FIRE RETARDANT CEILING PLAN TREATED WOOD FOR RETURN AIR PLENUM CEILINGS) DENTAL COLUMN LIGHT SUPPORT DETAIL NOT TO SCALE FRAME INTO VERTICAL STUI AND SECURE WITH FRAMING SCREWS ISEE REFLECTED T CEILING PLAN COFFERED CEILING DETAIL NOT TO SCALr= z IL 0 z U G uj I- u .j U. ui rg uj uj 0 ACOUSTIC TILE CEILING im Lu F- U U. Lu Lu 46 SOFFIT SUPPORT: SEE DETAILe �4) V. A_6 .......... SEE REFLECTED CEILING PLAN BOX SOFFIT DETAIL NOT TO SCALE LINE OF STRUCTURE ABOVE 5/8' DRYWALL z z U TWO (2) SELF-TAPPING DRYWALL FRAMING SCREWS AT BOTH SIDES OF EACH STUD 2'x 4" METAL STUD FRAMING AT 16' O.C. Lu u ui _j U. ul W. ui W 44 z 0 z l= Iuj lu CONCRETE OR METAL DECK Aq ..,q f: TWO (2) SELF-TAPPING DRYWALL FRAMING SCREWS AT BOTH SIDES OF EACH STUD 5 r -.,AL*E STUD TRACK W1114 TWO (2) POWER SET STEEL PINS SIDE BY SIDE AT 161 O.G. DRYWALL ON METAL FRAMING: SEE SOFFIT DETAILS SUPPORT AT CONC. DECK SUPPORT PARALLEL OR TO METAL DECK PERPENDICULAR TO METAL DECK SOFFIT SUPPORT DETAILS (4\ NOT TO SCALE NOTE SEE ARCHITECT FOR APPROVED ALTERNATE SUPPORT BRACKETS. CEILING SUPPORT BRACKET DETAIL NOT TO SCALE CROSS BRACE AS REQUIRED GRID SUPPORT WIRES T-RUNNER SUSPENSION SYSTEM . . .... T ULAR' (RECESSED) EDGE ACOUSTIC TILE CEILING ANGLE EDGE TRIM CAULK ALL WALL TO WALL ANGLE GAPS 5/61 DRYWALL METAL WALL FRAMING CEILING EDGE DETAIL (2 NOT TO SCALE I A-61 iv,--WIRE TIES: 3 -TIGHT TURNS WITHIN 3 INCHES HEAVY DUTY MAIN RUNNER ­ . . . . . . . . . . . . . . . . CROSS TEE WITH MAX. DEFLECTION OF 1/360 #12 GA. HANGER WIRES SPACED AT 4'-0' O.C. AND INSTALLED VERTICALLY PLUMB CEILING SUSPENSION DETAIL NOT TO SCALE C4 u.j 9 V) O uj n V) CEILING EDGE, SEE DETAIL / A/C SUPPLY AIR REGISTER (TYP.) CEILING NOTES of GENERAL SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF ASTM C-635 AND ASTM C-636, (F.B.C. B803.9) VERIFY CEILING FIRE RATING REQUIREMENTS WITH BUILDING OFFICIAL, FIRE MARSHAL AND LANDLORD PRIOR TO THE COMMENCEMENT OF CEILING WORK. PLENUM SYSTEMS INCLUDING ELECTRICAL, PLUMBING, HN.A.C.; ETC. SHALL BE INSPECTED AND TESTED PRIOR TO CLOSING ANY CEILINGS. SEE REFLECTED CEILING PLAN AND FINISH SCHEDULE FOR OTHER CEILING FINISH REQUIREMENTS AND SPECIFICATIONS. Fo-2 HANGER WIRES HANGER WIRES SHALL BE 12-GAUGE AND SPACED A MAXIMUM OF 4-FEET ON CENTER. WIRE TIES SHALL BE THREE (3) TIGHT TURNS AROUND ITSELF WITHIN 3 INCHES. HANGER WIRES SHALL BE USED TO INDEPENDENTLY SUPPORT THE CEILING TEE BARS TO THE STRUCTURAL MEMBERS OF THE FLOOR OR ROOF ABOVE. HANGER WIRES SHALL BE STRAIGHT AND VERTICALLY PLUMB. SUSPENDED LIGHT FIXTURES SHALL BE ANCHORED AT ALL CORNERS IN THE SAME MANNER AS THE CEILING GRID. ALL CEILING SUPPORT REQUIREMENTS SHALL BE VERIFIED ON THE JOB SITE AND WITH THE MANUFACTURER'S REPRESENTATIVE, FO-31 HEIGHT AND LAYOUT SEE REFLECTED CEILING PLAN FOR CEILING AND SOFFIT HEIGHTS, ACOUSTIC TILE LAYOUTS AND GRID STARTING POINTS, UNLESS SPECIFIED OTHERWISE. FO-41 CLOSETS CLOSET CEILING S SHALL BE MOUNTED AT THE SAME HEIGHT AS ADJACENT SPACE, UNLESS SPECIFIED OTHERWISE. SEE REFLECTED CEILING PLAN. 0-51 GRID SYSTEM CEILING TILES SHALL BE MOUNTED IN A COLOR MATCHED, INVERTED METAL TEE BAR GRID AS MANUFACTURED BY "DONN" . 0-61 REPLACEMENT TILES THE CONTRACTOR SHALL SUPPLY THE OWNER WITH ONE (1) SEALED CARTON OF EACH TYPE OF CEILING TILE USED IN THE PROJECT. THE LOT NUMBER OF THESE TILES SHALL MATCH THE LOT NUMBER OF THE TILES USED IN THE PROJECT. WE CEILING TILES ALL SUSPENDED CEILING TILES, UNLESS SPECIFIED OTHERWISE, SHALL BE: MANUFACTURER USG INTERIORS PRODUCT LINE FROST TEXTURE FINE PANEL SIZE - 24" x 24" SUPPORT GRID DONN l'DX"/"DXU' EDGE PROFILE SHADOWLINE BEVEL (SLB) COLOR WHITE FIRE CLASS "All NRC 70 VERIFY TILE SELECTIONS WITH OWNER, STEVEN B. SCHWORTZ, ARCHITECT AND/OR INTERIOR DESIGNER. CEILING SOUNDPROOFING INSTALL 6-1/41 'OWENS-CORNING" SONOBATT SOUNDPROOFING ABOVE ALL CEILINGS. (TYPICAL) CONCRETE SLAB 1 *,mmmwm',mjvm 7 Ir CEILING MOUNTED DENTAL COLUMN LIGHT SEE 01!7AIL,,"�, I" LONG FRICTION FIT LEAD ANCHOR SLEEVE SET IN PRE-DRILLED HOLE 1/4" DIAMETER THREADED SUPPORT ROD WITH LOOP NOTE SEE ARCHITECT FOR APPROVED ALTERNATE SUPPORT BRACKETS. CEILING SUPPORT BRACKET DETAIL NOT TO SCALE CROSS BRACE AS REQUIRED GRID SUPPORT WIRES T-RUNNER SUSPENSION SYSTEM . . .... T ULAR' (RECESSED) EDGE ACOUSTIC TILE CEILING ANGLE EDGE TRIM CAULK ALL WALL TO WALL ANGLE GAPS 5/61 DRYWALL METAL WALL FRAMING CEILING EDGE DETAIL (2 NOT TO SCALE I A-61 iv,--WIRE TIES: 3 -TIGHT TURNS WITHIN 3 INCHES HEAVY DUTY MAIN RUNNER ­ . . . . . . . . . . . . . . . . CROSS TEE WITH MAX. DEFLECTION OF 1/360 #12 GA. HANGER WIRES SPACED AT 4'-0' O.C. AND INSTALLED VERTICALLY PLUMB CEILING SUSPENSION DETAIL NOT TO SCALE C4 u.j 9 V) O uj n V) CEILING EDGE, SEE DETAIL / A/C SUPPLY AIR REGISTER (TYP.) CEILING NOTES of GENERAL SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF ASTM C-635 AND ASTM C-636, (F.B.C. B803.9) VERIFY CEILING FIRE RATING REQUIREMENTS WITH BUILDING OFFICIAL, FIRE MARSHAL AND LANDLORD PRIOR TO THE COMMENCEMENT OF CEILING WORK. PLENUM SYSTEMS INCLUDING ELECTRICAL, PLUMBING, HN.A.C.; ETC. SHALL BE INSPECTED AND TESTED PRIOR TO CLOSING ANY CEILINGS. SEE REFLECTED CEILING PLAN AND FINISH SCHEDULE FOR OTHER CEILING FINISH REQUIREMENTS AND SPECIFICATIONS. Fo-2 HANGER WIRES HANGER WIRES SHALL BE 12-GAUGE AND SPACED A MAXIMUM OF 4-FEET ON CENTER. WIRE TIES SHALL BE THREE (3) TIGHT TURNS AROUND ITSELF WITHIN 3 INCHES. HANGER WIRES SHALL BE USED TO INDEPENDENTLY SUPPORT THE CEILING TEE BARS TO THE STRUCTURAL MEMBERS OF THE FLOOR OR ROOF ABOVE. HANGER WIRES SHALL BE STRAIGHT AND VERTICALLY PLUMB. SUSPENDED LIGHT FIXTURES SHALL BE ANCHORED AT ALL CORNERS IN THE SAME MANNER AS THE CEILING GRID. ALL CEILING SUPPORT REQUIREMENTS SHALL BE VERIFIED ON THE JOB SITE AND WITH THE MANUFACTURER'S REPRESENTATIVE, FO-31 HEIGHT AND LAYOUT SEE REFLECTED CEILING PLAN FOR CEILING AND SOFFIT HEIGHTS, ACOUSTIC TILE LAYOUTS AND GRID STARTING POINTS, UNLESS SPECIFIED OTHERWISE. FO-41 CLOSETS CLOSET CEILING S SHALL BE MOUNTED AT THE SAME HEIGHT AS ADJACENT SPACE, UNLESS SPECIFIED OTHERWISE. SEE REFLECTED CEILING PLAN. 0-51 GRID SYSTEM CEILING TILES SHALL BE MOUNTED IN A COLOR MATCHED, INVERTED METAL TEE BAR GRID AS MANUFACTURED BY "DONN" . 0-61 REPLACEMENT TILES THE CONTRACTOR SHALL SUPPLY THE OWNER WITH ONE (1) SEALED CARTON OF EACH TYPE OF CEILING TILE USED IN THE PROJECT. THE LOT NUMBER OF THESE TILES SHALL MATCH THE LOT NUMBER OF THE TILES USED IN THE PROJECT. WE CEILING TILES ALL SUSPENDED CEILING TILES, UNLESS SPECIFIED OTHERWISE, SHALL BE: MANUFACTURER USG INTERIORS PRODUCT LINE FROST TEXTURE FINE PANEL SIZE - 24" x 24" SUPPORT GRID DONN l'DX"/"DXU' EDGE PROFILE SHADOWLINE BEVEL (SLB) COLOR WHITE FIRE CLASS "All NRC 70 VERIFY TILE SELECTIONS WITH OWNER, STEVEN B. SCHWORTZ, ARCHITECT AND/OR INTERIOR DESIGNER. CEILING SOUNDPROOFING INSTALL 6-1/41 'OWENS-CORNING" SONOBATT SOUNDPROOFING ABOVE ALL CEILINGS. (TYPICAL) CEILING SYMBOL LEGE.ND EXIT SIGN WITH BATTERY BACK-UP EMERGENCY LIGHT WITH ry BATTERY BACK -UP RECESSED 141-14AT FLUORESCENT LIGHT FIXTURE (30 WATTS TOTAL) PIN SPOT FIXTURE (50 WATTS TOTAL) 2'-Ol X 21-0", 02Ul-TUBE LAY-IN FLUORESCENT LIGHT FIXTURE (55 TOTAL WATTS) 2--0' X 2--0', 2-lu-Tual!"To LAY-IN PARABOLIC FLUORESCENT LIGHT FIXTURE (55 WATTS TOTAL) 2' -0" X 4'-0 "l 3-TUBE, TO E)E:] LAY-IN PARABOLIC FLUORESCENT V1�:)Ell 17-19 LIGHT FIXTURE (B2 WATTS TOTAL) 2'-00 X 4'-0" 3-TUBE, LAY-IN T-5 FLUORESCENT LIGHT FIXTURE (75 WATTS TOTAL) EXHAUST FAN - RECTANGULAR AIR SUPPLY REGISTER (ONE-WAY BLOW) SQUARE AIR SULY PP REGI STER FOR - (MULTI - DIRECTIONAL) r=--7 - RETURN AIR GRILLE RETURN AIR GRILLE AND FILTER CEILING MOUNTED "LCD" MONITOR. SEE OWNER FOR SELECTION AND MOUNTING CEILING MOUNTED 'DENTAL COLUMN LIGHT" FIXTURE: SEE MANUFACTURER'S REPRESENTATIVE FOR COMPLETE DETAILS CEILING HEIGHTS ABOVE FINISHED FLOOR (A.F.F.) I X' -X" CEILING HEIGHT INDICATOR BUBBLE CEILING HEIGHT OF CEILING AS MEASURED FROM FACE OF FINISHED FLOOR To FACE OF FINISHED CEILING. SOFFIT HEIGHT INDICATOR BUBBLE es i T HEIGHT OF SOFFIT AS MEASURED FROM FACE OF FINISHED FLOOR TO FACE OF FINISHED SOFFIT, 2'-0' x 4'-0' LAY-IN .WINDOW .EYJS*nNG WAI V-WAV - A I I I (INSIDE TO INSIDE) t 36'-5" 1 SUSPENDED ACOUSTIC TILE CEILING: SEE DETAIL A -6 HANGER WIRES: SEE 'CEILING NOTES' 1O21 2 Z� 0 -Z x CFJLING GRID: SEE 'CEILING NOTES, 0-51 CEILING TILES SEE 'CEILING NOTES" 071 CEILING MOUNTED LCD MONITOR. SEE OWNER FOR SELECTIt AND MOUNTING REQUIREMENTS (TYP CLOSET CEILING SEE CEILING NOTES' 0-4-1 T COFFERED CEILING: SEE DETAIL/*7\ (INSIDE TO INSIDE) T Z 0 REFLECTED CEILING PLAN SCALE: 1/4" = 1'- ON' PROJECT FLOOR AREA = 1,081.67 SQ.FT. Li n V) Lu !2 cn ME rMr % co m ' "wy X 0 U. co Qj c 0 • v (a (D 0 m� ems CL E Jc t 0 Z L4 111P 31 COPYRIGHT 2013 EVEN B. SCHWORTZ ARCHITECT, P.A. ALL RIGHTS RESERVED NO PART OF THESE PLANS MAY BE REPRODUCED OR USED IN ANY WAY OR FORM WITHOUT THE EXPRESS WRITTEN CONSENT OF STEVEN B. SCHWORTZ ARCHITECT, P.A. PLANS MUST BE RETURNED UPON REQUEST. • uj cr) 0 ui LL 0 co 6 us Lu = uj 0 w U- _j 0 > 0 Lu z " M LL. LL- 0 C) • COD z w a Iwo-2111 ol�_ COM: 2012-17 REVISIONS: ALIEN ARCHITECTURE DATE: 02-25-2013 BY: S.B.S. TOTAL NUMBER OF DRAWINGS IN SET: 21 r, 1 *,mmmwm',mjvm 7 Ir CEILING MOUNTED DENTAL COLUMN LIGHT SEE 01!7AIL,,"�, CEILING SYMBOL LEGE.ND EXIT SIGN WITH BATTERY BACK-UP EMERGENCY LIGHT WITH ry BATTERY BACK -UP RECESSED 141-14AT FLUORESCENT LIGHT FIXTURE (30 WATTS TOTAL) PIN SPOT FIXTURE (50 WATTS TOTAL) 2'-Ol X 21-0", 02Ul-TUBE LAY-IN FLUORESCENT LIGHT FIXTURE (55 TOTAL WATTS) 2--0' X 2--0', 2-lu-Tual!"To LAY-IN PARABOLIC FLUORESCENT LIGHT FIXTURE (55 WATTS TOTAL) 2' -0" X 4'-0 "l 3-TUBE, TO E)E:] LAY-IN PARABOLIC FLUORESCENT V1�:)Ell 17-19 LIGHT FIXTURE (B2 WATTS TOTAL) 2'-00 X 4'-0" 3-TUBE, LAY-IN T-5 FLUORESCENT LIGHT FIXTURE (75 WATTS TOTAL) EXHAUST FAN - RECTANGULAR AIR SUPPLY REGISTER (ONE-WAY BLOW) SQUARE AIR SULY PP REGI STER FOR - (MULTI - DIRECTIONAL) r=--7 - RETURN AIR GRILLE RETURN AIR GRILLE AND FILTER CEILING MOUNTED "LCD" MONITOR. SEE OWNER FOR SELECTION AND MOUNTING CEILING MOUNTED 'DENTAL COLUMN LIGHT" FIXTURE: SEE MANUFACTURER'S REPRESENTATIVE FOR COMPLETE DETAILS CEILING HEIGHTS ABOVE FINISHED FLOOR (A.F.F.) I X' -X" CEILING HEIGHT INDICATOR BUBBLE CEILING HEIGHT OF CEILING AS MEASURED FROM FACE OF FINISHED FLOOR To FACE OF FINISHED CEILING. SOFFIT HEIGHT INDICATOR BUBBLE es i T HEIGHT OF SOFFIT AS MEASURED FROM FACE OF FINISHED FLOOR TO FACE OF FINISHED SOFFIT, 2'-0' x 4'-0' LAY-IN .WINDOW .EYJS*nNG WAI V-WAV - A I I I (INSIDE TO INSIDE) t 36'-5" 1 SUSPENDED ACOUSTIC TILE CEILING: SEE DETAIL A -6 HANGER WIRES: SEE 'CEILING NOTES' 1O21 2 Z� 0 -Z x CFJLING GRID: SEE 'CEILING NOTES, 0-51 CEILING TILES SEE 'CEILING NOTES" 071 CEILING MOUNTED LCD MONITOR. SEE OWNER FOR SELECTIt AND MOUNTING REQUIREMENTS (TYP CLOSET CEILING SEE CEILING NOTES' 0-4-1 T COFFERED CEILING: SEE DETAIL/*7\ (INSIDE TO INSIDE) T Z 0 REFLECTED CEILING PLAN SCALE: 1/4" = 1'- ON' PROJECT FLOOR AREA = 1,081.67 SQ.FT. Li n V) Lu !2 cn ME rMr % co m ' "wy X 0 U. co Qj c 0 • v (a (D 0 m� ems CL E Jc t 0 Z L4 111P 31 COPYRIGHT 2013 EVEN B. SCHWORTZ ARCHITECT, P.A. ALL RIGHTS RESERVED NO PART OF THESE PLANS MAY BE REPRODUCED OR USED IN ANY WAY OR FORM WITHOUT THE EXPRESS WRITTEN CONSENT OF STEVEN B. SCHWORTZ ARCHITECT, P.A. PLANS MUST BE RETURNED UPON REQUEST. • uj cr) 0 ui LL 0 co 6 us Lu = uj 0 w U- _j 0 > 0 Lu z " M LL. LL- 0 C) • COD z w a Iwo-2111 ol�_ COM: 2012-17 REVISIONS: ALIEN ARCHITECTURE DATE: 02-25-2013 BY: S.B.S. TOTAL NUMBER OF DRAWINGS IN SET: 21 r,