13-706-0040 z CL 0 0 u� 4 r� i.. cl T. o N N rx m a N W m Z a N W r 3 ww a f- o F o CL a ARCHITECTURAL NOTES F051 DETAILS AND NOTES THE GENERAL NOTES AND TYPICAL DETAILS APPLY THROUGHOUT THE JOB UNLESS NOTED OR INDICATED OTHERWISE. DETAILS OR NOTATIONS LABELED "TYPICAL" OR "TYP" SHALL APPLY TO ALL SIMILAR CONSTRUCTION CONDITIONS THROUGHOUT THE PROJECT. DETAILS OR FEATURES OF THE CONSTRUCTION WHICH ARE NOT FULLY SHOWN ON THE DRAWINGS SHALL BE OF THE SAME CONSTRUCTION AS SIMILAR CONDITIONS SHOWN OR NOTED. THE OMISSION OF DETAILS AND /OR THE LACK OF REPETITION OF DETAILS, NOTES, OR FIGURES ON MULTIPLE DRAWING SHEETS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PERFORMING ALL OF THE WORK INDICATED THROUGHOUT THE CONSTRUCTION DOCUMENTS. 02 STRUCTURAL MEMBERS STRUCTURAL MEMBERS SHALL NOT BE CUT, NOTCHED OR MODIFIED IN ANY WAY WITHOUT EXPRESS WRITTEN APPROVAL OF STEVEN B. SCHWORTZ, ARCHITECT OR THE ENGINEER. 03 DIMENSIONS THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD. HE SHALL COMPARE AND COORDINATE ALL DRAWINGS AND THE WORK OF ALL TRADES AT THE TIME THE WORK IS PERFORMED ON THIS STRUCTURE, DO NOT SCALE THE DRAWINGS. UNLESS OTHERWISE INDICATED ALL DIMENSIONS ARE TAKEN FROM THE ROUGH (UNFINISHED) FACE OF NEW BLOCK AND PARTITIONS OR THE FINISHED FACE OF EXISTING WALLS. ® INTERIOR WALL LAYOUT THE "NOMINAL" WALL THICKNESS DIMENSIONS SHOWN ON THE PLANS ARE REQUIRED TO BE USED FOR LAYOUT PURPOSES. SNAP CHALK LINES AT ALL WALL LINE LOCATIONS SHOWN ON EITHER THE FLOOR PLAN OR LAYOUT PLAN. BASE PLATES AND /OR STUD TRACK RUNNERS SHALL BE CENTERED AND SQUARED BETWEEN CHALK LINES. FO-51 DRYWALL ALL DRYWALL SHALL BE 5/8 " MINIMUM UNLESS SPECIFIED OTHERWISE, DRYWALL THICKNESS FOR WALLS AND CEILINGS SHALL BE AS SPECIFIED IN THE WALL SYMBOL LEGEND; FLOOR PLAN: LAYOUT PLAN; REFLECTED CEILING PLAN AND /OR WALL SECTIONS. 06 DRYWALL SCREWS SCREWS USED TO SECURE DRYWALL SHALL BE OF THE TYPE SPECIFIED BY THE MANUFACTURER FOR ATTACHMENT TO THE BACKING MATERIAL, SCREWS SHALL BE DRIVEN INTO THE DRYWALL FACE PAPER DEEP ENOUGH TO FORM A "DIMPLE" BELOW THE SURFACE, BUT SHALL NOT PENETRATE THE PAPER. SCREWS THAT MISS THE BACKING MATERIAL OR PENETRATE THE FACE PAPER SHALL BE REMOVED AND REPLACED WITH PROPERLY INSTALLED SCREWS. O7 SCREW SPACING SCREWS USED TO SECURE DRYWALL SHALL BE SPACED AT A MINIMUM OF 8" O.C. AROUND THE PERIMETER OF THE BOARD AND 12" O.C. IN ALL OTHER AREAS. 08 LEVEL OF DRYWALL FINISH UNLESS SPECIFIED OTHERWISE, ALL DRYWALL SHALL BE FINISHED IN ACCORDANCE WITH "GYPSUM ASSOCIATION" SPECIFICATION "GA -214 LEVEL 5" AS FOLLOWS : ALL JOINTS AND INTERIOR ANGLES SHALL HAVE TAPE EMBEDDED IN JOINT COMPOUND AND TWO SEPARATE COATS OF JOINT COMPOUND APPLIED OVER ALL FLAT JOINTS AND ONE SEPARATE COAT OF JOINT COMPOUND APPLIED OVER INTERIOR ANGLES, FASTENER HEADS AND ACCESSORIES SHALL BE COVERED WITH THREE COATS OF JOINT COMPOUND. A THIN SKIM COAT OF JOINT COMPOUND TROWEL APPLIED, OR A MATERIAL MANUFACTURED ESPECIALLY FOR THIS PURPOSE AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, SHALL BE APPLIED TO THE ENTIRE SURFACE, THE SURFACE SHALL BE SMOOTH AND FREE OF TOOL MARKS AND RIDGES, Fo__9j MOISTURE RESISTANT DRYWALL MOISTURE RESISTANT DRYWALL (M.R. BOARD) SHALL BE USED IN TOILET ROOMS AND OTHER AREAS SUBJECT TO OCCASIONAL CONTACT WITH WATER. 1O DOORS DOOR SIZE, TYPE AND FINISH SHALL BE AS SPECIFIED IN THE DOOR SCHEDULE. STAINED DOORS SHALL HAVE "SKINS" OF BEECH, BIRCH, ASH OR OAK; PAINTED DOORS SHALL HAVE "SKINS" MADE OF HARDBOARD OR BIRCH UNLESS SPECIFIED OTHERWISE. LAUAN DOOR "SKINS" ARE NOT PERMITTED. SEE OWNER AND /OR INTERIOR DESIGNER FOR PAINT OR STAIN COLORS AND MANUFACTURER. F151 DOOR MODIFICATIONS THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING DOORS DOWN TO PROVIDE PROPER CLEARANCES AFTER FINISHED FLOOR SURFACES AND /OR THRESHOLDS HAVE BEEN INSTALLED. 12 WOOD WOOD IN CONTACT WITH MASONRY SHALL BE PRESSURE TREATED OR SEPARATED FROM CONTACT BY THE USE OF AN APPROVED SEPARATING MATERIAL, BARRIER OR COATING. 13 WOOD TRIM WHERE STAINED DOORS ARE SPECIFIED; ALL CASINGS, JAMBS AND TRIM SHALL BE MADE OF "CLEAR" WOOD UNLESS SPECIFIED OTHERWISE. WHERE PAINTED DOORS ARE SPECIFIED; ALL CASINGS, JAMBS AND TRIM MAY BE MADE OF SMOOTH SANDED FINGER JOINTED MATERIAL UNLESS SPECIFIED OTHERWISE, SEE FINISH SCHEDULE, OWNER AND /OR INTERIOR DESIGNER FOR LOCATIONS. 14 RUBBER BASEBOARDS RUBBER BASEBOARDS SHALL BE SUPPLIED AND INSTALLED BY THE FLOORING CONTRACTOR AS FOLLOWS: 4 "' COVELESS STYLE BASE SHALL BE USED ADJACENT TO CARPETED AREAS; 4" COVE TYPE BASE SHALL BE USED ADJACENT TO VINYL FLOORING. BASEBOARD MATERIAL SHALL BE INSTALLED FROM 100 FT. CONTINUOUS ROLLS. SEE FINISH SCHEDULE FOR LOCATIONS, 15 FLOOR SURFACE PREPARATION THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LEVELING, PATCHING, AND SMOOTHING OF ALL FLOOR SURFACES. HE SHALL NOT BE RESPONSIBLE FOR THE MINOR LEVELING OR BLENDING WORK WHICH IS CUSTOMARILY PERFORMED BY THE FLOORING CONTRACTOR. 16 FLOOR FINISHES THE OWNER SHALL SUPPLY AND INSTALL ALL FLOOR COVERINGS, EXCEPT AS NOTED UNDER "CERAMIC TILE" BELOW. SEE FINISH SCHEDULE AND /OR OWNER FOR SELECTIONS. 17 CERAMIC TILE CERAMIC TILE FOR TOILET ROOM FLOORS, BASES, WAINSCOTS AND WALLS SHALL BE SUPPLIED AND INSTALLED BY THE CONTRACTOR. SEE FINISH SCHEDULE FOR LOCATIONS AND OWNER FOR SELECTION AND /OR APPROVAL. Fl-81 CABINETRY (N.I.C.) THE CABINETRY SUB - CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CABINETRY FIT, INSTALLATION AND FINISHED DIMENSIONS, SUBMIT SHOP DRAWINGS FOR APPROVAL BY THE OWNER PRIOR TO FABRICATION. SEE OWNER FOR ALL CABINETRY REQUIREMENTS. 19 SHELVING ALL SHELVING SHALL HAVE ADEQUATE BACKING AND SUPPORT FOR THE INTENDED USE. SEE FLOOR PLAN OR OWNER FOR ALL SHELVING REQUIREMENTS. 20 BACKING PROVIDE A 1 "X 4" WOOD BACKING FOR ALL CABINETS INDICATED ON THE PLANS OR SPECIFIED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL BACKING REQUIREMENTS. 21 PATCHING WHERE EXISTING WALLS, ROOFS OR FIXTURES ARE REMOVED: WALLS, CEILINGS AND FLOORS SHALL BE PATCHED; ELECTRIC AND PLUMBING SHALL BE CAPPED. EXISTING DEMISING WALLS, PARTITIONS AND OTHER REMAINING FINISHED WALLS SHALL BE PATCHED OR REFINISHED AS REQUIRED. 22 CAULKING ALL CAULKING WORK SHALL COMPLETED PRIOR TO THE APPLICATION OF PAINT. APPLY AROUND ALL DOOR CASINGS, FRAMES, TRIM AND OPEN JOINTS TO PROVIDE A SMOOTH TRANSITION BETWEEN SURFACES. UNLESS SPECIFIED OTHERWISE ALL CAULKING SHALL BE FORMULATED WITH SILICONE; HAVE A MINIMUM GUARANTEED LIFE EXPECTANCY OF TWENTY FIVE (25) YEARS AND BE PAINTABLE. F2_31 PAINTING ALL DRYWALL SHALL HAVE TWO COATS OF PAINT APPLIED OVER "USG "- "SHEETROCK FIRST COAT" BRAND SEALER. INTERIOR PAINTS SHALL BE "REGAL AQUAGLOW" LATEX SEMI -GLOSS ENAMEL', AS MANUFACTURED BY "BENJAMIN MOORE PAINTS" OR APPROVED EQUAL, SEE INTERIOR DESIGNER AND /OR OWNER FOR ALL PAINT COLORS. 24 INSULATION ALL INSULATION WHETHER CONCEALED OR EXPOSED SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE - DEVELOPED INDEX OF NOT MORE THAN 450. RADIATION EXPOSURES AROUND A PANORAMIC DENTAL X -RAY UNIT SOURCE: DIVISION OF ORAL RADIOLOGY AND ORAL MEDICINE, FACULTY OF DENTISTRY, UNIVERSITY OF WESTERN ONTARIO, CANADA. JUNE Igg3 REID JA, MACDONALD JC, DEKKER TA, KUPPERS BU. TEST PROCEDURE: TO EVALUATE THE RADIATION HAZARD IN THE VICINITY OF 'A PANORAMIC X -RAY UNIT, EKTASPEED PERIAPICAL FILMS WERE PLACED IN AN ARRAY BEHIND AND TO THE SIDE OF THE UNIT. THEY WERE LEFT IN PLACE FOR 7 MONTHS, DURING WHICH 1414 EXAMINATIONS WERE CARRIED OUT. THE MAXIMUM EXPOSURE AT 80 CM FROM THE PATIENT WAS DETERMINED TO BE ABOUT I MGY IN 7 MONTHS WITH A HEAVY WORKLOAD. THIS SHOWS CLEARLY THAT NO SPECIAL ENVIRONMENTAL SHIELDING BARRIERS ARE NECESSARY AROUND THIS UNIT. F2--51 STAINS STAINS SHALL BE SEMI - TRANSPARENT OR SEMI -SOLID AS MANUFACTURED BY "OLYMPIC STAIN COMPANY". STAINS SHALL BE APPLIED ACCORDING TO THE MANUFACTURER'S WRITTEN INSTRUCTIONS. SEE OWNER, ARCHITECT AND /OR INTERIOR DESIGNER FOR ALL STAIN LOCATIONS AND COLORS. 26 ALIGNED WALLS WHERE INDICATED TO BE "ALIGNED" THE CONTRACTOR SHALL ADJUST THE POSITIONING OF THE WALL TO FORM A SMOOTH TRANSITION BETWEEN EXISTING SURFACES AND NEW SURFACES 27 CURVED WALLS CURVED WALLS WITH A RADIUS OF 1 " -8" OR LESS SHALL HAVE A MAXIMUM STUD SPACING OF 5" CENTER TO CENTER. CURVED WALLS UP TO A RADIUS OF C -0 " SHALL HAVE STUDS SPACED AT NO MORE THAN 10" CENTER TO CENTER. CURVED DRYWALL PARTITIONS SHALL BE MADE WITH TWO (2) LAYERS OF "GOLD BOND" 1/4" HIGH FLEX WALLBOARD PANELS. FOLLOW MANUFACTURER'S INSTALLATION RECOMMENDATIONS. OPTIONAL METHODS FOR THE CONSTRUCTION OF CURVED WALLS INCLUDE: SKIM COATED DRYWALL; PLASTER OR A COMBINATION OF MATERIALS. SEE ARCHITECT FOR APPROVAL OF OPTIONAL METHODS. 28 MASONRY OPENINGS THE CONTRACTOR SHALL VERIFY MASONRY DOOR AND WINDOW OPENING REQUIREMENTS WITH THE CORRESPONDING MANUFACTURER PRIOR TO PLACEMENT OF CONCRETE OR CONCRETE BLOCK WORK. NO ADDITIONAL PAYMENTS SHALL BE MADE TO THE CONTRACTOR FOR HIS FAILURE TO VERIFY THESE REQUIREMENTS. AMERICANS WITH DISABILITIES ACT EMPLOYEE WORK AREAS DEFINITION: ALL OR ANY PORTION OF A SPACE USED ONLY BY EMPLOYEES AND USED ONLY FOR WORK. CORRIDORS, TOILET ROOMS, KITCHENETTES AND BREAK ROOMS ARE NOT EMPLOYEE WORK AREAS. DEFINITION SOURCE: PUBLISHED IN THE FEDERAL REGISTER JULY 23, 2004 AND AMENDED AUGUST 5, 2005. ISSUED BY THE 'UNITED STATES ACCESS BOARD' AND THE '2012 FLORIDA ACCESSIBIUTY CODE FOR BUILDING CONSTRUCTION': 106.5 'DEFINED TERMS'. 2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION: 206.2.6 EMPLOYEE WORK AREAS. COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS SHALL COMPLY WITH 402, EXCEPTIONS: 1.) COMMON USE CIRCULATION PATHS WITHIN EMPLOYEE WORK AREAS THAT ARE LESS THAN 1000 SQUARE FEET (g3 M2) AND DEFINED BY PERMANENTLY INSTALLED PARTITIONS, COUNTERS, CASEWORK, OR FURNISHINGS SHALL NOT BE REQUIRED TO COMPLY WITH 402. 2.) COMMON USE CIRCULATION PATHS LOCATED WITHIN EMPLOYEE WORK AREAS THAT ARE AN INTEGRAL COMPONENT OF WORK AREA EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH 402. DENTAL CHAIR AND X -RAY UNIT INSTALLATIONS 1.) DENTAL CHAIRS AND X -RAY UNITS ARE NOT A PART OF THE CONSTRUCTION WORK ILLUSTRATED IN THESE DOCUMENTS OR CONSIDERED TO BE REQUIRED FIXED EQUIPMENT. THE INSTALLATION OF DENTAL CHAIRS OR X -RAY UNITS IS NOT INCLUDED IN THE WORK DESCRIBED IN THESE DOCUMENTS. 2,) THESE PLANS ONLY REQUIRE THE INSTALLATION OF THE ILLUSTRATED ELECTRIC AND PLUMBING UTILITIES FOR EACH DENTAL CHAIR AND X -RAY UNIT. 3,) INSTALLATION OF ANY DENTAL CHAIR OR X -RAY UNIT IS AT THE SOLE DISCRETION OF THE OWNER AND SHALL BE PERFORMED BY THE EQUIPMENT MANUFACTURER'S REPRESENTATIVE UNDER SEPARATE PERMIT AND CONTRACT AS REQUIRED. 0 C4 'HANDICAPPED - '' DRINKING FOUNTAIN' SEE DETAIL 8 A -8 F1 N I S H SC H E D U L E MARK ROOM FLOOR BASE WALLS CEILING REMARK'S" 100 RECEPTION CARPET 4" STRAIGHT RUBBER PAINT ACOUSTIC TILE 101 BUSINESS OFFICE CARPET 4" STRAIGHT RUBBER PAINT ACOUSTIC TILE " 102 DOCTOR'S OFFICE CARPET 4" STRAIGHT RUBBER PAINT ACOUSTIC TILE 103 GALLERY CARPET 4" STRAIGHT RUBBER PAINT ACOUSTIC TILE 104 HYGIENE #1 VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 105 HYGIENE #2 VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 106 EXAM #1 VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 107 EXAM #2 VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 108 STERILIZATION VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 109 LAB VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 110 EQUIPMENT VINYL TILE 4" RUBBER COVE PAINT ACOUSTIC TILE 111 TOILET CERAMIC TILE CERAMIC TILE ACOUSTIC TILE *CERAMIC TILE TO CEILING INTERIOR FINISHES ALL INTERIOR FINISHES INCLUDING WALLCOVERINGS AND FLOORING SHALL COMPLY WITH 'F.B.C.- BUILDING' SECTION WI AND WITH THE 'F.F.P.C. d NFPA -101', SECTION 38.3.3. HAZARD ORDINARY (NFPA) OCCUPANCY FLAME SPREAD CLASS "C" - (76 -100) WALLS AND CEILINGS- CLASS "C" - (76 -100) FLOOR FINISHES CLASS "C" - (76 -100) EXIT FLAME SPREAD -- - ----«- CLASS "A" - (0-25) OR "B" (26 -75) ACCESSIBILITY SEE DRAWING SHEET A -9 FOR "FLORIDA ACCESSIBILITY CODE REQUIREMENTS ". IDOOR CLEARANCES DRAWING SHEET A -g FOR ALL A' DOOR CLEARANCE REQUIREMENTS, ELEVATION DIFFERENCES 1.) DIFFERENCES IN FLOOR ELEVATIONS SHALL NOT EXCEED 1/2', (TYPICAL) 2.) CHANGES IN ELEVATION EXCEEDING 114" BUT NOT EXCEEDING 1/2' SHALL BE BEVELED 1:2. 3.) WALKING SURFACES IN THE MEANS OF EGRESS SHALL COMPLY WITH N.F.PA. 101.7.1.6, EQUIPMENT PLACEMENT THE EXACT PLACEMENT OF EQUIPMENT AND DENTAL CHAIRS SHALL BE DETERMINED BY THE MANUFACTURER'S REPRESENTATIVE. SEE INTERIOR DESIGN CABINET BACKING: SEE 'ARCHITECTURAL DRAWINGS FOR ALL NOTES' 20 CABINETRY (TYP,) EXISTING EXISTING EXISTING WINDOW WINDOW WINDOW CABINETRY SEE OWNER FOR ALL CABINETRY DESIGN, COLOR AND CONFIGURATION. FUTURE EQUIPMENT .` EQUIPMENT LABELED 'FUTURE' ' WILL NOT BE INSTALLED UNDER THIS PERMIT (TYP.) P 1 , B LAV EXAM #2 LAV EXAM #1 DR'S OFF. I p UPPER dt I UPPER & 1 LOWER DENTAL.• `:`.' :`: :. , DENTA[,.;. 't LINE OF WALL t CABINETS : %' CHAIR:.`;; I LOWER :: ='CHAIR;:;;:: MOBIL MOUNTED j ;:::: (FI,i IUR i CABINETS 4 FUTURE ' CART HYG #2 CABINETS (TYP.) ' = : = r , BON 48' CLEAR FLOOR ° FIRE EXTINGUISHER r AND CABINET: SEE AREA CENTERED ON ! CABINET DRINKING FOUNTAIN AS p FIRE PROTECTION ' r NOTES ON DRAWING LAV C(s ♦ SECTION 602AGGESSIBILITY ( SHEET LS -I REF -- --- --- -__ __ ' HYG #1 STERILE ® z o h Y _ - .�.• ., �, s —_ � ' I•• . I 2 - A' : 1 0- : C F OU N TA IN . _TOILET ROOM SIGN: DRINKING 60 a - 'S E DRAWING A -9 FIRE x 56 ' CLEAR F EXTk . MANEUVERING SPACE _FOR ADA REQUIREM ENT S _ 6 •� j t ,\ • " CABINET GALLERY FOR WATER CLOSET DRAWING S44EET A -5 MO BIL '(; :::FD:CUE. HTNAUTIARRE L:: • :' f , in rSINK _ ♦`�'" im'_ 'HARDWARE STANDARDS 1 a ( CART ° UPPER &' I AND NOT _- ' yy SCAN— AND ' 'HANDICAPPED" F: i 1 LOWER_..:, I . C- 03r -.: GRANITE COUNTERTOP. - HANDICAPPED EQUIPPED CABINETS a TOILET ROOM AS PER -SEE SHOP DRAWINGS N20 2012 F.A.C.F.C. SECTION = N .; _ 4 « r...... -i-. -- ` • {: , LAV ACCESSIBLE 604: SEE DETAIL/-, '.FOR DETAILS i `: ROUTE '" — ° 'UPPER & WATER '' .3........,.• _ .... ' `;'`'.: X•RA A-Li F r I.LOWER ° CLOSET .: a a LEAR ;PAN p'7 t CL TANK CABINETS + .'....T:.... _ �= 30x48 C �, 1 --- FLOOR AREA AT u m x -RAY :� . ' LAVATORY �. e,. I (FUTURE] 4 GRAB BAR: f,:;, . slyk w /.. _ " , SEE DETAIL PLASTER - - -- / BUS. OFF. w I _ sHELVEs 4 #s >`< (TRAP s LAB'. A -8 5' ' vac _ , •0" DIAMETER 29" HIGH TOILET ROOM ` ` E ILL' WATER UNIT +� J i "HANDICAPPED' AREA DESK SEE "HARDWARE HARDWARE: SEE -: ` LENOID STANDARDS AND 'HARDWARE f 1 ':' ' *:: "` i' QUIP. :T i 36 "x 48" CLEAR NOTES' Q I :z .WASHER ::. MANEUVERING SPACE MIN. 36' LONG x MAX. STANDARDS AND d AIR ' COMP t FOR DOOR ACCESS 36' HIGH "HANDICAPPED' NOTES' 02 ---"COMBO ' -- , PASS ACCESSIBLE COUNTER SHELVING: SEE THRU (F.B.C, -B1I- 7.2(2)): OWNER FOR SEE DETAIL REQUIREMENTS EQUIP. ROOM _ Y_ (TYPICAL) HARDWARE: , i• WALL t SASE. f:. ExISTiNC °. A -8 SEE "HARDWARE } --CABINETS. SEE STANDARDS AND -SHOP DRAWINGS 000R ° It: Ma'z �♦ rrt, NOTES" O-41 , t . :�:° '. (•TYPICAL }j. �µ ; `,• 3 RECEPTION EXISTING PARKING PHONE BOARD: `. ,0IVIN&. :ALyf1INtIT?f `� MINIMUM 1 -6 WIDE' T1aROLD 'SF.E' t . n AND ROADWAY SY 2' -6" HIGH, 3/4 ". 'CHAi!ICES IF( ELVATOONn" EXISTING. ,. EXISTING PLYWOOD W/ WHITE : - bN• DRAYS %•SI•IEE�` Aitl' WINDOW' WINDOIV: «» + , •FIRE RETARDANT: k .I"UR . ADas , ,GOME'LIANGE• ' •, �'• •WALK -UVA'Y � • . . °. :` PAINT FINISH: REQUIREI TENTS , EXISTING AREA (INSIDE TO INSIDE) S C A L E: 1./4" = -1 -- O" PROJECT FLOOR AREA fm 1,081.67 SQ.FT. (INSIDE TO INSIDE) ! NITROUS OXIDE AND OXYGEN TANK CLOSET. SEE 'CATEGORY -3 MEDICAL ,^ CLOSURE' NOTES 2 ON D A -5 0 Z THIS IS THE GROUND FLOOR OF THE BUILDING (FLOOR ABOVE)