09-1045-027HVAC DESIGN REQUIRES:
HVAC GENERAL
NOTES:
I.
1 -HE WORK THAT IS TO BE DONE UNDER THIS HEADING INCLUDES THE
15.
INSULATION:
CFM SUPPLY/ OUTSIDE AIR
FURNISHING OF ALL LABOR, MATERIAL-.S AND EQUIPMENT, PERMIZS,
SMOKE DAMPER(S)
_
10
ESP -IN WG.
FEES, INSPECTIONS, TESTS, INSURANCE, FTC. REQUIRED FOR THE
TEMP. AIR ENT. COIL_ DB/WB
A: PIPING: CONDENSATE PIPING AND REFRIGERANT
FIRE RATED ROOF CEILING ASSEMBLY
COMPLETION OF THE AIR CONDITIONING AND VENTILATION SYSTEM
VOLTAGE
PIPING SHALL BE INSULATED WITH 3/4" FIRE RATED FLEXIBLE
MANUFACTURER
SHOWN ON DRAWINGS AND /OR I.-IS I ED BELOW.
SMOKE CONTROL
FOAM INSULATION. FINISHED WHERE EXPOSED WITH 2 COATS OF
C.U. MODEL
- -
RAPCO48JAZ
-- SEER -- -
WHITE LATEX PAINT ALL AS PER THE MANUFACTURER'S
REF LIQUID /SUCTION
3/8" - 1 -1/9"
— MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT
IN NON AIR CONDITIONING SPACES
— PROVIDE PROGRAMMABLE THERMOSTAT.
INSTRUCTIONS.
un
- - - -1 - PROVIDE 4" CLEARANCE/
16.
FILTERS:
/0/�
u)
AROUND AHU
(fl
A. PROVIDE MIN. OF TWO SETS OF TEMPORARY FIBERGLASS FILTERS OF
z
THE SAME THICKNESS AS FINAL FILTERS FOR USE DURING CONSTRUCTION.
3.
ALL NEW FLEXIBLE DUCTWORK SHALL BE SELF SUPPORTING ALUMINUM
B. PROVIDE MIN. OF TWO SETS OF FINAL FILTERS, 1" THICK, DISPOSABLE TYPE,
CONSTRUCTION AND INSULATED WITH 2" THICK BLANKET TYPE FIBERGLASS
3/4" ANCHOR BOLT BY 6" EA. CORNER W 14X4
06
INSULATION WITH EXTERIOR VAPOR BARRIER, HIGH PRESSURE TYPE
BY %4" WELDED A/C COPM. SHALL BE
FIRE RETARDANT FOR FACING.
17.
CONTROL SYSTEM SHALL BE COMPLETE IN ALL RESPECTS INCLUDING ALL
MARK DATE DESCRIPTION
LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY TO MEET THE
4.
FLAME AND SMOKE RATING: ALL INSULATION PRODUCTS USED INSIDE
FUNCTIONAL DESCRIPTION.
R.A.P. REVISION AFTER PERMIT
THE BUILDINGS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25
CONCRETE BASE
A. ALL CONTROL WIRING AND CONDUIT SHALL ME PROVIDED BY THE
D.D.C. BUILDING DEPT. COMMENTS
AND A MAXIMUM SMOKE GENERATION OF 50 IN ACCORDANCE WITH
6X610 /10WWF
ELECTRICAL CONTRACTOR AND SHALL BE IN ACCORDANCE WITH N.E.C.
C.C. COORDINATION CHANGES
TESL S OUTLINED IN N.F.P.A. #255.
ENTRANCE OF REFRIGERANT T LINES INTO
AND ALL LOCAL CODES AND ORDINANCES.
R.S. PERMIT SET
D.U. DESIGN DEVELOPMENT
UNDERSLAB
P.V.0 PIPE W/ IMPERMEABLE, RESILIENT MATERIAL.
B. FURNISH AND INSTALL ALL SENSORS, ACTUATORS, CONTROLLERS,
5.
DUCTWORK THERMAL INSULATION REQUIREMENTS:
_ ,
TRANSMITTERS, RELAYS, WIRING AND EQUIPMENT REQUIRED TO MEET
S.R.R. SITE PLAN REVIEW
THE DESIGN INTENT AND FUNCTIONAL DESCRIPTION OF THE CONTROL
6.
ALL AIR CONDITIONING DUCTWORK INSTALLED IN CEILING SHALL ME:
CONDENSING UNIT
SYSTEM.
DRAWN BY: A.P. &P. P.W.
18,
ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR THE PERIOD
CHECKED BY: L.B.
A. EXTERNALLY INSULATED WITH 1 1/2" THICK, 3/4 LM. DENSITY
N.T.S
OF ONE YEAR. COMPRESSOR SHALL CARRY 5 YEAR FACTORY GUARANTEE.
FIBERGLASS BLANKET (WITH A 5.2 "R" VALUE MINIMUM) COVERED
FURNISH ONE YEAR FREE SERVICE.
WITH FLAMEPROOF REINFORCED ALUMINUM FOIL FACED PAPER
19.
ALL FAN DRIVES SHALL ME ADJUSTED TO DELIVER THE SPECIFIED CFM
OR VAPORSEALED. INSTALLED AS PER MANUFACTURE'S RECOMENDATIONS.
AGAINST THE ACTUAL STATIC PRESSURE OF THE INSTALLATION.
B. FLEXIBLE DUCT RUNOUTS SHALL BE ROUND DUCTWORK
20.
ALL WORK SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES TO
REINFORCED WITH A WIRE HELIX AND INSULATED WITH 1 -1/2"
AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION AND IN STRICT
THICK FIBERGLASS (WITH A 6 "R" VALUE MINIMUM) COVERED
COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS.
WITH FLAMEPROFF VAPOR BARRIER OF ALUMINUM METALIZED
21.
ALL OUTSIDE EQUIPMENT SHALL BE SECURED TO WITHSTAND 150 M.P.H.
POLYESTER FILM LAMINATED TO GLASS MESH. DUCT SHALL ME
WINDS.
METALFLEX TYPE 700 PE OR EQUAL. CONNECTIONS TO DUCT
MAINS SHALL BE MADE WITH FITTINGS PROVIDED WITH TWIST RINGS,
22,
ALL WORK SHALL ME DONE IN ACCORDANCE WITH THE LATEST EDITION
BUTTERFLY DAMPERS, QUADRANT OPERATORS, AND INSULATION
OF THE FLORIDA BUILDING CODE, N.F.P.A. 90A ✓k 90B, AND
IN ACCORDANCE WITH ALL LOCAL CODES AND ORDINANCES.
GUARDS.
23.
CONTRACTOR SHALL BE RESPONSIBLE TO TEST AND BALANCE THE SYSTEM
7.
VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE
TO ACHIEVE RATES AS SHOWN ON PLANS AND SCHEDULES.
ORDERING ANY EQUIPMENT.
TEST /BALANCE RESULTS SHALL BE SUBMITTED TO ARCHITECT/ENGINEER
FOR REVIEW PRIOR TO FINAL PAYMENT REQUISITION. THE TEST AND
8.
CONTRACTOR SHALL VERIFY SPACE. CONDITIONS AND DIMENSIONS
BALANCE SHALL BE PERFORMED MY AN INDEPENDENT T&M CONTRACTOR
AND SHALL COORDINATE WORK WITH ALL OTHER TRADES AT JOBSITE
CERTIFIED BY THE A.A.d.C. AND/OR N.E.B.B.
PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK.
THE SUBMITTED TEST AND BALANCE REPORT SHALL BE ON OFFICIAL
A.A.d.C. OR N.E.d.B. REPORT FORMS.
9.
ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID IN-
24.
FANS, AIR DISTRIBUTION, AND CONTROLS SHALL
TERFERENCE WITH PROGRESS OF CONSTRUCTION AND IN STRICT COM-
BE AS SHOWN ON THE DRAWINGS WITH RESPECT TO CAPACITY,QUALITY
PLIANCE WITH ALL APPLICABLE CODES AND STANDARDS.
PERFORMANCE ,ACCESSORIES,ETC.MANUFACTURERS USED FOR THE BASIS OF
10.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE
DESIGN ARE LISTED ON THE DRAWINGS SCHEDULES OR SPECIFIED HEREIN.
SUBSTITUTIONS MUST MEET OR EXCEED ALL SPECIFIED REQUIREMENTS.
2001 EDITION, N.F.P.A,. S.M.A.C.N.A, ASHRAE AND APPLICABLE LOCAL CODES
NAMING ACCEPTABLE MANUFACTURERS DOES NOT RELIEVE THE CONTRACTOR
AND ORDINANCES.
FROM COMPLIANCE WITH ALL DESIGN REQUIREMENTS SHOWN ON THE
DRAWINGS OR LISTED HEREIN.
11.
OFFSET DUCTWORK AS REQUIRED TO ACCOMMODATE STRUCTURAL
AND OTHER TRADES.
25.
PROVIDE ALL UNITS WITH PROGRAMMABLE THERMOSTAT WITH MANUAL CHANGEOVER,
12,
ALL EQUIPMENT, MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED
HEAT /OFF /COOL SYSTEM SWITCH, 7 DAY, AUTO /ON FAN SWITCH, BATTERY
FOR A PERIOD OF ONE YEAR. COMPRESSORS SHALL CARRY 5 YEARS
FACTORY GUARANTEE. FURNISH 90 DAYS FREE SERVICE.
13.
CONTRACTOR SHALL COORDINATE ALL BUILDING STANDARD REQUIRE-
MENTS PRIOR TO BID.
14.
ALL CONDENSATE DRAIN PIPING SHALL ME TYPE "L" COPPER TUBING
WITH SILVER SOLDER JOINTS. PROVIDE TRAP WITH CLEANOUT AND
UNIONS.
HVAC DESIGN REQUIRES:
YES
NO
DUCT SMOKE DETECTOR
48,000
SENS CAPACITY BTU/HR
FIRE DAMPER(S)
CFM SUPPLY/ OUTSIDE AIR
1,600/240
SMOKE DAMPER(S)
_
10
ESP -IN WG.
FIRE RATED ENCLOSURE
TEMP. AIR ENT. COIL_ DB/WB
80/67
FIRE RATED ROOF CEILING ASSEMBLY
26.2
VOLTAGE
FIRE STOPPING
MANUFACTURER
RHEEM
SMOKE CONTROL
RHSAHM4821JA
C.U. MODEL
- -
A/C SPLIT SYSTEM SCHED.
UNIT MODEL.
-
TOTAL CAPACITY BTU/HR
48,000
SENS CAPACITY BTU/HR
35,850
CFM SUPPLY/ OUTSIDE AIR
1,600/240
HEATER KW
_
10
ESP -IN WG.
0.30
TEMP. AIR ENT. COIL_ DB/WB
80/67
C.U. FLA
26.2
VOLTAGE
1 -60 -240
MANUFACTURER
RHEEM
AHU MODEL
RHSAHM4821JA
C.U. MODEL
- -
RAPCO48JAZ
-- SEER -- -
- - -� 140
.0
REF LIQUID /SUCTION
3/8" - 1 -1/9"
— MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT
IN NON AIR CONDITIONING SPACES
— PROVIDE PROGRAMMABLE THERMOSTAT.
E.F. -1 SHALL BE BROAN MODEL
No. 688 @ 120V/1 PH /60
HZ. 1 /4" SP 50 CFM
WBACKDRAFT DAMPER.
k i r%--r- _
12 PERSON X20 CFM /PERSON = 240 CFM O/A REQUIRED
O/A PROVIDED 8" MTL DUCT ADJUST @ 2.40 CFM
5/8" DRY
CEILING
DRYWALL
PARTITIO
TANKLES
WATER H
VACUUM
AIR COM
9 "0 THERMOFIN EXHAUST DUCT
TO 4"0 G.M.D- (SEE PLANS)
STEEL HANGER WIRE
TYPICAL CEILING CABINET EXHAUST
FAN WITH BACK DRAFT DAMPER, LOW
NOISE LEVEL AND NO VIBRATION
\/ '--FRONT FACE GRILLE
WITH FASTENING SCREENS
LEXHAUST FAN HANGING BRACKET (ADJUSTABLE)
CEILING MOUNTED CABINET
EXHAUST FAN DETAIL
N.T.S.
LOW VELOCITY
SUPPLY AIR DUCT
(SEE PLAN VIEW)
INSUL R -6
METAL ROUND FITTING
QUADRANT OPERATOF
TO BE OUTSIDE INSUL
PROVIDE INSULATION
WHERE NECESSARY
INSULATED FLE:
1V F /G,WITH POI
AIR FLOW JACKETAND STE
WIRE REINFORC
►-I
SEAL JOINT WITH
EPDXY & DUCT TAPE
PERFORATE
TYPICAL CO
N.T.S.
NNECTION DETAIL
MECHANICAL ATTACH
PLENUMS AND RETURN
W /FLEXIBLE CONN.
SUPPLY DUCT
R/A yl —► D UCY
3/4" CONDENSATE
DRAIN w/ 3" TRAP
UNION AND C.O TO
GREEN AREA
GALV. STEEL
A.H.U. SUPPORT
(SELF- STANDING)
NO COMBUSTIBLE
MATERIALS WITHIN
A.H.U. ROOM
EQUIPMENT CLOSET DETAIN ELEVATION
SCALE: 112" =1' -0"
FIT
',0101
REFRIGERANT LINES
TO OUTSIDE CONDENSING
UNIT 4" UNDERGROUND
PVC SLEEVE SCH40
a" OUTSIDE AIR
- -- T—
a" OUTSIDE AIR
INTAKE ADJUST (a? - 24 X 21//'
240 CFM VENT TI-11` IU RAC
ROOF /
/
_..20X14
REF. LINES
WOMEN
OFFICE
12 X 8CD
200 CFM
14XY4 -1�?
RAG
EMPLOYEE
LOUNGE
12 X 8CD
200 CFM
RECEP.
I r o 1 I I
100 12XaCD
---- - - -i�J -- - - - - -- a "O 1
-- - - - -- -� - -- -------- - - - - -- 200 CFM
a"
I s �
„
4 X 14 STERILIZATION
- - -- RAG_ — -- -- -- - - - -L- - - - - -- - -- -- - - -- -- _ - --
"T 11111111►[t
AREA
12_ X SCD
II
200 CFM
II
II
II
11 X 14 a" O
MECHANICAL PLAN
SCALE: 11/4"=V-0"
METAL STRAP AROUND C.U.
(20 GAUGE)
ENTRY
N
8
Fill
12415 S.W. 137 AVE. SUITE 103
MIAMI, FLORIDA 33116
T. (305) 271 -7776
F. (305) 271 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
CONSULTANTS
V
-
z_
CEILING
CONDENSING
2" COND. DRAIN 6"
,ads,.�,s+ ;
r J �,rl�'`
K iNL
�._
ABOVE GRADE
}. uih 2i4A
AND 12" MIPJ-
\ MEN
FRONT EX-1 - WALL
-- PERFORATED CAP FOR
1
EQUIP.
C 'SETT AHU,
U
W
Lj
LL
U
_Q
oN
(D
_
'—�
un
- -- T—
a" OUTSIDE AIR
INTAKE ADJUST (a? - 24 X 21//'
240 CFM VENT TI-11` IU RAC
ROOF /
/
_..20X14
REF. LINES
WOMEN
OFFICE
12 X 8CD
200 CFM
14XY4 -1�?
RAG
EMPLOYEE
LOUNGE
12 X 8CD
200 CFM
RECEP.
I r o 1 I I
100 12XaCD
---- - - -i�J -- - - - - -- a "O 1
-- - - - -- -� - -- -------- - - - - -- 200 CFM
a"
I s �
„
4 X 14 STERILIZATION
- - -- RAG_ — -- -- -- - - - -L- - - - - -- - -- -- - - -- -- _ - --
"T 11111111►[t
AREA
12_ X SCD
II
200 CFM
II
II
II
11 X 14 a" O
MECHANICAL PLAN
SCALE: 11/4"=V-0"
METAL STRAP AROUND C.U.
(20 GAUGE)
ENTRY
N
8
Fill
12415 S.W. 137 AVE. SUITE 103
MIAMI, FLORIDA 33116
T. (305) 271 -7776
F. (305) 271 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
CONSULTANTS
V
z_
CEILING
CONDENSING
,ads,.�,s+ ;
r J �,rl�'`
K iNL
�._
J
}. uih 2i4A
:D
co
-- PERFORATED CAP FOR
w:D
VENT, 12" HIGH
U
W
Lj
LL
0
z
_Q
oN
(D
_
'—�
un
- - - -1 - PROVIDE 4" CLEARANCE/
-
/0/�
u)
AROUND AHU
(fl
z
w
z1\\ 11 -22 -11 B.D.C.
\\
W
3/4" ANCHOR BOLT BY 6" EA. CORNER W 14X4
06
-- FLOAT SWITCH
BY %4" WELDED A/C COPM. SHALL BE
AIR HANDLER UNIT
INSTALLATION DETAIL
NO SCALE
I
�.t~
i 4,
z LEOP.OLD0 BELLQ , .ALA (AR-- 008737)
",_
Cl ANGEL MILANES, AIA (AR- 0015845)
SHEET TITLE
MECHANICAL PLAN
M -1
SHEET OF
CEILING
CONDENSING
,ads,.�,s+ ;
r J �,rl�'`
K iNL
�._
UNIT
}. uih 2i4A
PARTITION
-- PERFORATED CAP FOR
VENT, 12" HIGH
- - - - - --
_
6" MIN ABOVE GRADE
POWER & CONTROL
- —_ SECONDARY DRAIN
'—
AS PER FMC 304.7 °f o
o
CONNECTIONS
—— —
- - - -1 - PROVIDE 4" CLEARANCE/
O z-
AROUND AHU
z1\\ 11 -22 -11 B.D.C.
\\
3/4" ANCHOR BOLT BY 6" EA. CORNER W 14X4
01.15.09 D.D.
-- FLOAT SWITCH
BY %4" WELDED A/C COPM. SHALL BE
INSTALLED ABOVE BASE FLOOD ELEVATION.
MARK DATE DESCRIPTION
4" SCHEDULE 40 P.V.C. PIPE INCREASE
A.D. AS -BUILT
FLOOR
SIZE AS REQUIRED BY LENGHT AND ROUTING
R.A.P. REVISION AFTER PERMIT
_ C
CONCRETE BASE
D.D.C. BUILDING DEPT. COMMENTS
6X610 /10WWF
C.C. COORDINATION CHANGES
- -- --
2 "A/C C.D.
ENTRANCE OF REFRIGERANT T LINES INTO
SUCTION LINE W/ 1 112" ARMAFLEX
R.S. PERMIT SET
D.U. DESIGN DEVELOPMENT
UNDERSLAB
P.V.0 PIPE W/ IMPERMEABLE, RESILIENT MATERIAL.
INSULATION & VAPOR BARRIER
R.H. PUBLIC HEARING
_ ,
S.R.R. SITE PLAN REVIEW
PROJECT No. I_B107
CONDENSING UNIT
MOUNTING DETAIL
DRAWN BY: A.P. &P. P.W.
CHECKED BY: L.B.
N.T.S
AIR HANDLER UNIT
INSTALLATION DETAIL
NO SCALE
I
�.t~
i 4,
z LEOP.OLD0 BELLQ , .ALA (AR-- 008737)
",_
Cl ANGEL MILANES, AIA (AR- 0015845)
SHEET TITLE
MECHANICAL PLAN
M -1
SHEET OF