Loading...
09-1045-016ACCESSIBILITY NOTES (FOR BUILDINGS ACCESSIBLE TO THE PUBLIC) ( F. B. C. 2001 EDITION /CHAPTER 11 ) 1. BUILDING ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE WITH NO CHANGE IN LEVEL OF MORE THAN 1/2" ALONG ROUTE AND MAX. LEVEL CHANGE OF 1/2" AT ENTRY DOORS OR THRESHOLDS. 2. ALL DOORS IN ACCESSIBLE ROOMS SHALL PROVIDE A CLEAR OPENING OF 32 INCHES WHEN DOOR IS OPEN 90 DEGREES (A STANDARD 34 INCH DOOR PROVIDES AN ACCEPTABLE NOMINAL 32 INCH OPENING) 1 LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS ARE TO BE LOCATED WITH OPERABLE PARTS NO HIGHER THAN 48 INCHES AND NO LOWER THAN 15 INCHES ABOVE THE FLOOR. iF REACH IS OVER AN OBSTRUCTION SUCH AS A CABINET HEIGHT SHALL BE 44" FOR FORWARD APPROACH AND 46" FOR PARALLEL APPROACH. (NOTE: OBSTRUCTIONS MAY NOT EXTEND MORE THAN 25" FROM WALL). 4. REST ROOMS SHALL BE PROVIDED WITH GRAB BARS AROUND TOILETS, INSTALLED ACCORDING TO THE ILLUSTRATIONS SHOWN. TOILETS SHALL BE INSTALLED SO AS TO ALLOW A GRAB BAR TO BE INSTALLED ON ONE SIDE OF FIXTURE AND MINIMUM CLEARANCE BETWEEN TOILET AND ADJACENT FIXTURES OR WALLS SHALL BE 18 ". GRAB BARS SHALL BE MOUNTED @ 33" AFF. TOILET HEIGHT SHALL BE 17" TO 19" AS SHOWN, FLOOR MTD AND 30" IN DEPTH. VANITIES AND LAVATORIES SHALL BE A MIN OF 19" WIDE X 17" DEEP AND BE INSTALLED W/ A CLEARANCE OF 5 -1/2" DIVIDING LAVATORY AND ADJOINING WALL. FIXTURE RIM SHALL BE A MAXIMUM OF 2' -10" ABOVE FINISHED FLOOR- EXPOSED PIPES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. FAUCETS SHALL BE LEVER OPERATED, PUSH -TYPE OR ELECTRONIC CONTROLLED. 5. DOOR HARDWARE SHALL HAVE A SHAPE EASY TO GRASP WITHOUT TIGHT GRASPING. ACCEPTABLE DOOR MECHANISMS ARE: LEVER HANDLES, PUSH TYPE HARDWARE, AND U- SHAPED HANDLES. THESE SHALL BE MOUNTED NO HIGHER THAN 48" AFF. 6. TOILET STALL DOOR SWINGS OUT AND SHALL BE SELF CLOSING (F. B- C - CHAPTER 11 / 11-4.17,5)- DOOR CAN BE HINGED ON EITHER SIDE - 7. TOILET STALL DOOR WIDTH TO BE A MINIMUM OF 32 INCHES ( F. B. C. CHAPTER 11 / 11-4.13-5) 8. ACCESSIBILITY TO TOILET STALL DOOR SHALL BE IN COMPLIANCE WITH ADA GUIDELINES. 9. TOILET ACCESSORIES TO BE PROVIDED. MIRROR 17" MIN. 19" MAX. /111�I z N LEVER VALVE 1 6 "MAX. MIN. 9" PROTECTED PIPING LAVATORY CLEARANCES SCALE: 1/2" = 1' -0" 2 v i O � i ILL li O 0 SIDE WALL 1 5 SCALE: 1/2" = 1' -0" BATT. INSULATION WHERE NOTED ON PLANS -SEE WALL TYPES 112" DURROCK BOARD AS REQUIRED (3) 3/8" x 3" LONG R.H.W.S. INTO (2) 2 x 6 SOLID BLOCKING. SCOTING 1 1/4" DIA. 18 GA. METAL GRAB BAR W/ 3 3/4" STAINLESS STEEL FLANGE. GRAB BAR & MOUNTINGS SHALL WITHSTAND 250* /PT IN. BEND. SHEAR AND TENSION W/ 1/8" MIN. RADIUS ON ALL EDGES. BAR SHALL NOT ROTATE IN FITTINGS. NOTE: WHEN USING STEEL STUDS TO SUPPORT ANY WALL HUNG FIXTURES, STUDS SHALL BE NOT LESS THAN 20 GA. W/ A MIN. EFFECTIVE MOMENT OF INERTIA EQUAL TO 0.864 IN. (360 M ). AS PER FBC 2004, SCT. 2517.5 WALL HUNG GRAB BAR DETAIL 10 SCALE: 1/2" = 1' -0" PICTOGRAM APPLICATIONS: MEN'S TOILET (SIZE 5 "x 6 ") NOTE: SIGNAGE REQUIRED TO BE ACCESSIBLE ROOM SHALL COMPLY WITH (F. B. C. CHAPTER 11 / 11 -4.30 ) i i SIGN LOCATIONS ROOM DESIGNATIONS SCALE: 1/2" = V -0" WRITTEN SIGNAGE GRAPHIC WHERE APPROPIATE BRAILLE SIGNAGE WITH RAISED OR INCISED LETTERS NOTE: GRAB BARS SHALL COMPLY WITH: A LOAD OF NOT LESS THAN 250 LBS. APPLIED AT ANY POINT. ( F. B. C. CHAPTER 11 / 11- 4.26.3) ( F. B. C. CHAPTER 11 / 11-4.26. FIGURE 29 ) SIDE WALL 2 SCALE: 1/2" = V -0" 2" x 6" MIN. WOOD STUD BACKING AT 24" O.C. MAX. FOR ATTACHMENT OF WALL CABINET AND WALL HUNG PLUMBING FIXTURES AS PER FBC 2004, SECT. 2318.1 -15 NOTE: STEEL STUDS SUPPORTING WALL HUNG PLUMBING FIXTURES SHALL BE DOUBLE OR NOT LESS THAN 20113AGE ` WITH A MINIMUM EFFECTIVE MOMENT OF INERTIA EQUAL TO 0.864 in (360 m). AS PER TABLE 2510.5.1.1 F.B.C. WALL HUNG FIXTURE DETAIL 3 CALE: 112" = 1' -0" 3 4 TYP- BEARING WALL OR NON - BEARING PARTITION. SEE WALL FLOOR PLANS FOR LOCATIONS. N c-� x c� WRAP F�IPES WITH PIPE QED (OPEN BOTI SECTION) GRAB BARS AT WATER CLOSETS SCALE: 1/2" = V -0" nin-1-C- THE WALLS AND FLOORS OF ALL PUBLIC RESTROOMS SHALL BE LINED WITH A NON - ABSORBENT MATERIAL TO A MINIMUM HEIGHT OF 4 FT. ABOVE THE FLOOR. (F. B .0 . CHAPTER 12/1204.2) Will V -6" 1' -6„ V -3" MIN_ MIN_ MIN. 5' -6" L—A �. r I r 1 2 \ A ____ )_� A -4 I ACCESSIBLE TOILET GROUND FLOOR PLAN SCALE: 3/4"= V -0" 12465 S.W. 137 AVE. SUITE 103 MIAMI, FLORIDA 33186 T. (305) 278 -7776 F. (305) 276 -7473 WWW.BELLONMILANES.COM AA- 0003505 ARCHITECTURE LAND PLANNING INTERIORS CONSTRUCTION MANAGEMENT CONSULTANTS �.J z 0 uj M0 W W UwLL Q L N o cl) J � � Q — ' vO'/^� T J I- CD cfl r` z W 0 W W i-3UILC;i DEPT'. : T UCT ?JP tit L SECTION GRAB BARS AT WATER CLOSETS"' �.. SCALE: 112" = 1' -0" 01.15.09 D.D. MARK DATE DESCRIPTION A.I. AS —BUILT R.A.F. ACCESSORY LEGEND OTOILET TISSUE DISPENSER O36" GRAB BARS 2b 42" GRAB BARS OWALL MOUNTED LIGHT FIXTURE OFRAMED MIRROR WITH METAL SHELF OTOILET SITE PLAN REVIEW OH.C. LAVATORY OACCESSIBLE DRINKING FOUNTAIN R.A.F. REVISION AFTER PERMIT I.D.C. BUILDING DEPT. COMMENTS C.C. COORDINATION CHANGES P.S. PERMIT SET D, D. DESIGN DEVELOPMENT F.H. PUBLIC HEARING S.P.R. SITE PLAN REVIEW PROJECT No. LB107 DRAWN BY: A.P. & P.W. CHECKED BY: L.B. J a c y p V . rtY, `,q. x�s�aw a��w• X LEOPOLDO GELLON, AIA (AR- 008737) ❑ ANGEL MILANES, AiA (AR- 0015845) SHEET TITLE RESTROOMS DETAILS A -4 SHEET OF