09-1045-016ACCESSIBILITY NOTES
(FOR BUILDINGS ACCESSIBLE TO THE PUBLIC)
( F. B. C. 2001 EDITION /CHAPTER 11 )
1. BUILDING ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE WITH
NO CHANGE IN LEVEL OF MORE THAN 1/2" ALONG ROUTE AND
MAX. LEVEL CHANGE OF 1/2" AT ENTRY DOORS OR THRESHOLDS.
2. ALL DOORS IN ACCESSIBLE ROOMS SHALL PROVIDE A CLEAR
OPENING OF 32 INCHES WHEN DOOR IS OPEN 90 DEGREES (A
STANDARD 34 INCH DOOR PROVIDES AN ACCEPTABLE NOMINAL
32 INCH OPENING)
1 LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND
OTHER ENVIRONMENTAL CONTROLS ARE TO BE LOCATED WITH
OPERABLE PARTS NO HIGHER THAN 48 INCHES AND NO LOWER
THAN 15 INCHES ABOVE THE FLOOR. iF REACH IS OVER AN
OBSTRUCTION SUCH AS A CABINET HEIGHT SHALL BE 44"
FOR FORWARD APPROACH AND 46" FOR PARALLEL APPROACH.
(NOTE: OBSTRUCTIONS MAY NOT EXTEND MORE THAN 25" FROM
WALL).
4. REST ROOMS SHALL BE PROVIDED WITH GRAB BARS AROUND
TOILETS, INSTALLED ACCORDING TO THE ILLUSTRATIONS SHOWN.
TOILETS SHALL BE INSTALLED SO AS TO ALLOW A GRAB BAR TO
BE INSTALLED ON ONE SIDE OF FIXTURE AND MINIMUM CLEARANCE
BETWEEN TOILET AND ADJACENT FIXTURES OR WALLS SHALL BE
18 ". GRAB BARS SHALL BE MOUNTED @ 33" AFF. TOILET HEIGHT
SHALL BE 17" TO 19" AS SHOWN, FLOOR MTD AND 30" IN DEPTH.
VANITIES AND LAVATORIES SHALL BE A MIN OF 19" WIDE X 17"
DEEP AND BE INSTALLED W/ A CLEARANCE OF 5 -1/2" DIVIDING
LAVATORY AND ADJOINING WALL. FIXTURE RIM SHALL BE A
MAXIMUM OF 2' -10" ABOVE FINISHED FLOOR- EXPOSED PIPES
SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT
AGAINST CONTACT. FAUCETS SHALL BE LEVER OPERATED,
PUSH -TYPE OR ELECTRONIC CONTROLLED.
5. DOOR HARDWARE SHALL HAVE A SHAPE EASY TO GRASP WITHOUT
TIGHT GRASPING. ACCEPTABLE DOOR MECHANISMS ARE: LEVER
HANDLES, PUSH TYPE HARDWARE, AND U- SHAPED HANDLES.
THESE SHALL BE MOUNTED NO HIGHER THAN 48" AFF.
6. TOILET STALL DOOR SWINGS OUT AND SHALL BE SELF CLOSING
(F. B- C - CHAPTER 11 / 11-4.17,5)- DOOR CAN BE HINGED ON EITHER SIDE -
7. TOILET STALL DOOR WIDTH TO BE A MINIMUM OF 32 INCHES
( F. B. C. CHAPTER 11 / 11-4.13-5)
8. ACCESSIBILITY TO TOILET STALL DOOR SHALL BE IN
COMPLIANCE WITH ADA GUIDELINES.
9. TOILET ACCESSORIES TO BE PROVIDED.
MIRROR
17"
MIN.
19"
MAX.
/111�I
z
N
LEVER VALVE
1 6 "MAX.
MIN. 9"
PROTECTED PIPING
LAVATORY
CLEARANCES
SCALE: 1/2" = 1' -0"
2
v
i
O �
i
ILL
li O
0
SIDE WALL 1
5 SCALE: 1/2" = 1' -0"
BATT. INSULATION WHERE NOTED
ON PLANS -SEE WALL TYPES
112" DURROCK BOARD AS
REQUIRED
(3) 3/8" x 3" LONG R.H.W.S.
INTO (2) 2 x 6 SOLID
BLOCKING.
SCOTING
1 1/4" DIA. 18 GA. METAL
GRAB BAR W/ 3 3/4"
STAINLESS STEEL FLANGE.
GRAB BAR & MOUNTINGS
SHALL WITHSTAND 250* /PT
IN. BEND. SHEAR AND
TENSION W/ 1/8" MIN. RADIUS
ON ALL EDGES. BAR SHALL
NOT ROTATE IN FITTINGS.
NOTE:
WHEN USING STEEL STUDS TO SUPPORT ANY WALL
HUNG FIXTURES, STUDS SHALL BE NOT LESS THAN 20
GA. W/ A MIN. EFFECTIVE MOMENT OF INERTIA EQUAL
TO 0.864 IN. (360 M ). AS PER FBC 2004, SCT. 2517.5
WALL HUNG
GRAB BAR DETAIL
10 SCALE: 1/2" = 1' -0"
PICTOGRAM APPLICATIONS:
MEN'S TOILET (SIZE 5 "x 6 ")
NOTE:
SIGNAGE REQUIRED TO BE ACCESSIBLE ROOM
SHALL COMPLY WITH (F. B. C. CHAPTER 11 / 11 -4.30 )
i
i
SIGN LOCATIONS
ROOM DESIGNATIONS
SCALE: 1/2" = V -0"
WRITTEN SIGNAGE
GRAPHIC WHERE
APPROPIATE
BRAILLE SIGNAGE
WITH RAISED OR
INCISED LETTERS
NOTE:
GRAB BARS SHALL COMPLY WITH:
A LOAD OF NOT LESS THAN 250 LBS.
APPLIED AT ANY POINT.
( F. B. C. CHAPTER 11 / 11- 4.26.3)
( F. B. C. CHAPTER 11 / 11-4.26. FIGURE 29 )
SIDE WALL 2
SCALE: 1/2" = V -0"
2" x 6" MIN. WOOD STUD BACKING
AT 24" O.C. MAX. FOR ATTACHMENT
OF WALL CABINET AND WALL HUNG
PLUMBING FIXTURES AS PER FBC
2004, SECT. 2318.1 -15
NOTE:
STEEL STUDS SUPPORTING WALL HUNG
PLUMBING FIXTURES SHALL BE
DOUBLE OR NOT LESS THAN 20113AGE `
WITH A MINIMUM EFFECTIVE MOMENT OF
INERTIA EQUAL TO 0.864 in (360 m).
AS PER TABLE 2510.5.1.1 F.B.C.
WALL HUNG
FIXTURE DETAIL
3 CALE: 112" = 1' -0"
3
4
TYP- BEARING WALL OR
NON - BEARING PARTITION.
SEE WALL FLOOR PLANS
FOR LOCATIONS.
N
c-�
x
c�
WRAP F�IPES WITH PIPE
QED (OPEN BOTI
SECTION)
GRAB BARS
AT WATER CLOSETS
SCALE: 1/2" = V -0"
nin-1-C-
THE WALLS AND FLOORS OF ALL PUBLIC RESTROOMS SHALL BE LINED
WITH A NON - ABSORBENT MATERIAL TO A MINIMUM HEIGHT OF 4 FT.
ABOVE THE FLOOR. (F. B .0 . CHAPTER 12/1204.2)
Will
V -6" 1' -6„ V -3"
MIN_ MIN_ MIN.
5' -6"
L—A
�.
r
I
r
1
2
\ A ____ )_�
A -4
I
ACCESSIBLE TOILET
GROUND FLOOR PLAN
SCALE: 3/4"= V -0"
12465 S.W. 137 AVE. SUITE 103
MIAMI, FLORIDA 33186
T. (305) 278 -7776
F. (305) 276 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
CONSULTANTS
�.J
z
0
uj
M0
W
W
UwLL
Q
L N
o
cl) J � �
Q — ' vO'/^�
T J
I- CD
cfl
r`
z
W
0
W
W
i-3UILC;i DEPT'.
: T UCT ?JP
tit
L SECTION
GRAB BARS
AT WATER CLOSETS"' �..
SCALE: 112" = 1' -0"
01.15.09 D.D.
MARK DATE DESCRIPTION
A.I. AS —BUILT
R.A.F.
ACCESSORY LEGEND
OTOILET
TISSUE DISPENSER
O36"
GRAB BARS
2b
42" GRAB BARS
OWALL
MOUNTED LIGHT FIXTURE
OFRAMED
MIRROR WITH METAL SHELF
OTOILET
SITE PLAN REVIEW
OH.C.
LAVATORY
OACCESSIBLE
DRINKING FOUNTAIN
R.A.F.
REVISION AFTER PERMIT
I.D.C.
BUILDING DEPT. COMMENTS
C.C.
COORDINATION CHANGES
P.S.
PERMIT SET
D, D.
DESIGN DEVELOPMENT
F.H.
PUBLIC HEARING
S.P.R.
SITE PLAN REVIEW
PROJECT No. LB107
DRAWN BY: A.P. & P.W.
CHECKED BY: L.B.
J a c y p
V
. rtY, `,q. x�s�aw a��w•
X LEOPOLDO GELLON, AIA (AR- 008737)
❑ ANGEL MILANES, AiA (AR- 0015845)
SHEET TITLE
RESTROOMS DETAILS
A -4
SHEET OF