06-01R-009ELECTRICAL NOTES:
PART 1 - GENERAL:
1.- THE GENERAL AND SPECIAL CONDITION AND REQUIREMENTS OF THE CONTRACT AND
SPECIFICATION AS WELL AS PLANS AND SPECIFICATIONS OF OTHER DISCIPLINES AND
TRADES SHALL APPLY AND BE PART OF THE WORK HEREBY SPECIFIED. THESE SPECIFI-
CATION AND THE ACCOMPANYING PLANS ARE INTENDED TO PROVIDE FOR THE COMPLETE
FURNISHING AND INSTALLATION OF THE ELECTRICAL SYSTEMS.
2.- COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE
WITH THE LATEST EDITION OF NEC (IN SPECIAL SEC. 680),FBC, NFPA, NEMA, IEEE; OTHER
APPLICABLE NATIONAL STATE & LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY
AUTHORITIES HAVING JURISDICTION, AND SHALL MEET THE REQUIREMENTS OF OTHER
RECOGNIZED STANDARDS WHERE "PART 1 - GENERAL" THE REQUIREMENTS ARE MORE
STRINGENT THAN THOSE CITED ABOVE.
3.- WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST
CLASS MANNER AND SHALL BE COMPLETED AND FULLY OPERATIVE TO THE ACCEPTANCE
OF THE ARCHITECT /ENGINEER.
4.- MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS, BEARING THE UNDER-
WRITER'S LABORATORY (UL) LABEL AS APPLICABLE. MATERIALS SHALL BE ACCEPTABLE
AND ABOVE STANDARD QUALITY NORMALLY USED FOR THE PURPOSE AS CALLED FOR
ON PLANS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE DELIVERY SCHEDULES
OF MATERIALS.
5.- DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW APPROXIMATE EQUIPMENT
LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL; PLANS SHALL
NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS. PROVIDE ALL OFFSETS,
FITTINGS AND ACCESSORIES REQUIRED FOR A COMPLETE, ACCEPTABLE, WORKING INSTALLATION.
6.- SUPPLEMENTAL MATERIALS OR MANUFACTURED PRODUCTS NECESSARY TO COMPLY
WITH THE INTENT OF THE CONTRACT DRAWINGS OR SPECIFICATIONS, BUT NOT NOTED
OR SPECIFIED ON THESE SECTIONS, SHALL BE PROVIDED AS REQUIRED TO COMPLETE
THE INATALLATION AT NOT ADDITIONAL COST TO THE OWNER.
7 - EXISTING CONDITION: CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL
EXISTING CONDITIONS, WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL
NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING
CONDITIONS RESULT IN EXTRA MATERIAL OR LABOR. ANY EXISTING CONDITION
FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL IMMEDIA-
TELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER. CORRECTION OF
ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE
REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY
HAVE BEEN DAMAGED THEREBY.
8 - PERMITS: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES. TAXES, INSPECTION,
TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF A COMPLETE
ELECTRICAL SYSTEM AS OUTLINED HERE IN AND SHOWN ON PLANS. PROVIDE ALL REQUIRED
INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR
THE DURATION OF THE WORK.
9 - INTERFERENCE: PLANS ARE GENERALLY DIAGRAMMATIC AND THE CONTRACTOR SHALL
COORDINATE HIS WORK WITH THE WORK OF OTHER TRADES, SO THAT INTERFERENCES
WITH EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL. STRUCTURAL
AND WORK WITH OTHER TRADES WILL BE AVOIDED.
1 -
2 -
4 -
5 -
1 -
2 -
3 -
4 -
5 -
ELECTRICAL LEGEND
$M 120 V TOGGLE SWITCH, SINGLE POLE. ( +48" AFF UNLESS
OTHERWISE NOTED). VOLTAGE AS PER CIRCUIT DESIGNATION.
LETTER "M" INDICATE MOTORIZED RATED.
$3W 120 V THREE WAY TOGGLE SWITCH, SINGLE POLE. ( +48" AFF
UNLESS OTHERWISE NOTED). VOLTAGE AS PER CIRCUIT DESIGNATION.
DIMMER SWITCH, SINGLE POLE. ( +48" AFF UNLESS OTHERWISE NOTED.)
LOAD AS PER CIRCUIT LOAD, DO NOT OVERLOAD DIMMER OVER 80%
OF DIMMER RATED CAPACITY.
GROUNDED TYPE DUPLEX RECEPTACLE, WALL. ( +18" AFF UNLESS
OTHERWISE NOTED.) LETTER "D" DESIGNATION MEANS DEDICATED; LATTER "I"
DESIGNATION MEANS ISOLATED GROUND.
GROUNDED TYPE DUPLEX RECEPTACLE, WALL. ( +4" ABOVE COUNTER UNLESS
OTHERWISE NOTED.) LETTER "D" DESIGNATION MEANS DEDICATED; LATTER "I"
DESIGNATION MEANS ISOLATED GROUND.
GROUNDED TYPE DUPLEX RECEPTACLE, WALL HALF SWITCHED.
O JUNCTION BOX. INSTALL FAN TYPE JUNCTION BOX (FOR 50 LBS) IN ALL FANS.
TELEPHONE OUTLET, WALL. ( +18" AFF)
TV T.V. OUTLET CABLE
- - - CONDUIT CONCEALED IN OR UNDER FLOOR SLABS.
CONDUIT CONCEALED ABOVE CEILING OR IN WALL.
D PANEL
DISCONNECT SWITCH.
2 POLES, 240V ENCLOSED CIRCUIT BREAKER
ECB
GROUND CONNECTION.
ELECTRIC MOTOR CONNECTION.
WALL SCONCE (TO BE SELECTED)
0 DOWN LIGHT (TO BE SELECTED)
o UNDER CABINETS 2' FLUORESCENT LAMP.
-O - PENDANT LIGHTING 2ND FLOOR HALL
DELUXE SECURITY FLOOD LIGHTS
PART 2 - PRODUCTS: STD. SURF, MTD. FDCT.
DISCONNECT SWITCHES FOR POOL AREA SHALL BE QUICK -MADE, QUICK -BRAKE ACTION, POOL LIGHT
LOCKABLE TYPE PER "NEC 680 -12 ".
CONDUCTORS SHALL BE THW /THWN SOFT -DRAWN 98% CONDUCTIVITY COPPER INSTALLED IN
CONDUIT, COLOR CODED PER "NEC" AND TRADE STANDARDS. MINIMUM SIZE SHALL BE #12
FOR POWER WIRING AND #14 FOR CONTROL CIRCUITS. PROVIDE #10 WIRES FOR 120V POWER
CIRCUIT HOMERUNS LONGER THAN 100 FEET. ASIDE FROM THE PANELBOARD GUTTER,
CONDUCTORS ON THE LOAD SIDE OF A GFCI MUST NOT BE USED IN ANY RACEWAY OR OTHER
ENCLOSURE CONTAINING CONDUCTORS THAT ARE NOT GFCI - PROTECTED.
CONDUIT SHALL BE "RGS" OR "IMC" HOT- DIPPED GALVANIZED FOR ALL EXTERIOR LOCATIONS,
WHERE EXPOSED TO PHYSICAL DAMAGE. ALL FITTING SHALL BE STEEL. "PVC" SCHEDULE
40 SHALL BE USED WHERE CONDUIT IS RUN IN CONCRETE SLABS; "PVC" MAY BE RUN
UNDERGROUND WHERE BURIED 18" BELOW FINISHED GRADE, 24" UNDER VEHICULAR TRAFFIC
AREAS. GREENFIELD TYPE FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR MOTORS AND
VIBRATING EQUIPMENT CONNECTIONS, NOT TO EXCEED 18'; PROVIDE "PVC" JACKETED TYPE
FOR EXTERIOR AND /OR MOISTURE EXPOSED LOCATIONS. FOR UNDERWATER LIGHTING FIXTURES
AS PER 'NEC 680 -20.
CONNECT ALL SMOKE DETECTORS AHEAD OF SWITCHES THRU BATHROOMS OR KITCHEN
CIRCUIT. SMOKE DETECTORS SHALL OPERATE AT 120V AND HAVE BATTERY BACK -UP. KITCHEN OR
RATURf1(U TXr-T4T
THIS CONTRACTOR SHALL COORDINATE WITH FP &L THE CONNECTION FOR THIS SERVICE
AND REVISE INTERRUPTING CAPACITY AVAILABLE PRIOR INSTALLATION OF ALL DISCONNECTING
DEVISES, AND INCREASE THE INTERRUPTING CAPACITY IN PANELS AND DISCONNECTING DEVISES
IF REQUIRED.
PART 3 - EXECUTION:
CONDUIT RUNS, RACEWAYS AND PIPING SHALL BE CONCEALED IN WALLS, CEILINGS, SLABS
AND PARTITIONS; NO RACEWAYS SHALL BE EXPOSED WITHIN INTERIOR SPACES EXCEPT FOR
OPEN CEILING AREAS.
GROUNDING AND BONDING SHALL COMPLY WITH "NEC 250, 680 -24 & 25 ". ALL METALLIC
RACEWAYS SHALL BE GROUNDED AND BONDED PER "NEC 250 ". NON- METALLIC RACEWAYS
SHALL BE PROVIDED WITH A GROUNDING CONDUCTOR SIZED PER 'NEC 250 -95 ". PROVIDE
1 #8 SOLID BOUNDING CONDUCTOR TO CONNECT ALL METAL PARTS AT THE POOL SUCH AS
POOL REINFORCE STEEL, METAL JB'S, PUMP MOTORS, METAL CONDUITS, LIGHTING FIXTURES,
METAL SHIELD PRIMARY AND SECONDARY WINDING OF POOL TRANSFORMERS, POOL STAIRS, NOTE
ETC. TO COMPLY WITH 1996 NEC CODE SECTION 680 -22.
MOTORS, TRANSFORMERS AND MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH GREENFIELD SMOKE DETECTOR SHALL BE HARDWIRE (110 VOLT TYPE
FLEXIBLE CONNECTIONS, WATERLIGHT WHERE EXPOSED TO MOISTURE AND WEATHER CONDITIONS. TO A NON - SWITCHABLE KITCHEN OR BATHROOM LIGHTING
MOTORS TRASFORMERS AND MECHANICAL EQUIPMENT FOR THE POOL AND JACUZZI PER CIRCUIT�I'E WITH BATTERY LOAD AND SHALL NOT BE CIRCUIT
NEC 690-42'.
INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT
OUTLETS AND ANY OTHER EQUIPMENT INSTALLED IN POOL AREA SHALL BE INSTALL AT A SHALL BE INTERCONNECTED AS SHOWN IN PARALLEL.
SMOKE DETECTOR
MINNIMUN DISTANCE OF 10' -0" FROM POOL'S EDGE OR AS PER 1999 NEC CODE SECTION 680. SMOKE DETECTOR CONNECTION DETAIL
KAIC NOTE: THIS CONTRACTOR SHALL COORDINATE WITH FPL THE KAIC AVAILABBLE AND SCALE : N.T.S.
INCREASE OR DECREASE THE KAIC ACCORDENLY.
SMOKE DETECTOR NOTE:
ALL SMOKE DETECTORS SHALL BE 110V
WITH BATTETY BACK UP AND
INTERCONNECTED FROM KITCHEN OR
BATH LIGHTING CIRCUIT AHEAD OF ALL
SWITCHES.
SMOKE DETECTORS MAY BE WITHIN 20FT
OF A COOKING APPLIANCE AND NOT
CLOSER THAN 3FT FROM THE DOOR TO
BATHROOM, WASHER /DRYER, KITCHEN AND
A /C.
THE ACTIVATION OF ANY SMOKE
(DETECTOR SHALL ACTIVATE THE OTHERS.
I GENERAL NOTE:
ELECTRICAL OUTLETS ON FIRE RATED PARTITIONS
SHALL BE POSITIONED SO THEY ARE NOT
BACK -TO -BACK. OUTLETS INSTALL WITH A
MINIMUM DISTANCE OF 24" BETWEEN EACH BOX.
GROUND
LOAD CALCULATIONS
K /VOLT
AMP
GENERAL LIGHTING CONNECTED
TRIP
TOTAL HOUSE AREA
5206 SF
REMARKS
DESCRIPTION
LOAD
GENERAL LIGHTING ( 5,206 X 3)
15.61
KVA
SMALL APPLIANCE(3)
4.50
KVA
DRYER
5.00
KVA
WASHER MACHINE
1.50
KVA
COOK TOP
6.00
KVA
OVEN
6.00
KVA
DISHWASHER
1.50
KVA
WATER HEATER (1)
5.00
KVA
REFRIGERATOR
1.50
KVA
GARBAGE DISPOSAL
1.20
KVA
POOL EQUIPMENT
3.00
KVA
GENERAL LIGHTING LOAD
50.81
KVA
FIRST 10.OKW ® 100 %:
10.00
KVA
REMAINDER 40.81 KVA ® 40 %:
16.32
KVA
TOTAL
26.32
KVA
3 A/C UNITS ( ® 125 %)
30.00
KVA
POOL SYSTEM ( FUTURE)
15.00
KVA
SPRINKLER SISTEM (FUTURE)
3.00
KVA
NET COMPUTED LOAD
74.32
KVA
TOTAL AMPS. SERVICE LOAD
310
AMPS.
3 #4/0 THW CU IN 2 1 /2 "C.
3 #4/0 THW CU IN 2 1 /2 "C.
O GUTTER
8 "x8 "x48"
NEMA 3R PANEL PANEL
„B„ „A„
3 #300 MCM THW CU IN 3 1/2 "C.
METALLIC
WATER PIPE
1 - #1/0 C.U. GROUND IN 1" COND. TO 2- 5/8"X10"
CONNECTED TO C.W.P. AND BUILDING STEEL FOUNDATION.
3 #300 MCM THW CU IN 3 1 /2 "C.
TO FP &L TRANSFORMERS.
SEE ELECTRICAL NOTES #8 ON PART 1
& #5 OF PART 2 ON THIS SHEET.
ELECTRICAL RISER DIAGRAM
NO SCALE
TYPE: I.T.E. MAIN BUS: 22
SERVICE: 10, 3W PANEL A NEUTRAL: FIN
VOLTAGE: 1201240 V. 22 KAIC MINIMUM MAIN: M.L.O.
MOUNTING: FLUSH SEE NOTE #5 IN PART 3 IN THIS SHEET LOCATION: GARAGE
K /VOLT
AMP
POLE
TRIP
CONDUIT
WIRE
REMARKS
CKT.
NO.
CKT.
NO,
REMARKS
WIRE
CONDUIT
TRIP
POLE
K /VOLT
AMPS.
12.50
2
60
1"
#6
AHU #1
1
2
CU #1
#10
1"
30
2
6.25
3
4
1.50
1
20
1/2"
#12
SMALL APPLIANCE
5
6
COOK TOP
#8
i"
40
2
6.00
1.50
1
20
1/2"
#12
SMALL APPLIANCE
7
8
1.50
1
20
1/2"
#12
SMALL APPLIANCE
9
1
10
OVEN
#B
3/4"
40
2
6.00
0.50
1
20
1/2"
#12
BATH GFCI
it
1
12
0.50
1
20
1/2"
#12
BATH GFCI
13
#12
14
DISHWASHER
#12
1/2„
20
1
1.50
1.08
1
20
1/2"
#12
RECEPTACLES
15
#12
16
REFRIGERATOR
#12
1/2"
20
1
1.50
1.08
1
20
1/2"
#12
LIGHTS
17
#12
18
GARBAGE DISPOSAL
#12
1/2„
20
1
1.20
1.08
1
20
1/2"
#12
LIGHTS
19
#12
20
KITCHEN EXHAUST
#12
1/2"
20
1
1.20
1.08
1
20
1/2"
#12
LIGHTS
21
#10
22
POOL LIGHT
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
LIGHTS
23
1
24
GATE (MAIN)
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
LIGHTS
25
1
26
GATE
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
LIGHTS
27
28
GATE
#12
1/2"
20
1
1.08
1 0
0
1 2"
12
W R CHINE
29
1
30
RECEPTACLES
#12
1/2"
20
1
1.08
0.50
1
20
1/2"
#12
BATH GFCI
31
1
32
GENERAL LIGHTS AFCI *'
#12
1/2"
20
1
1.08
0.50
1
20
1/2"
#12
BATH GFCI
33
--
34
RECEPTACLES
#12
1/2"
20
1
1.08
.00
1
--
--
--
SPARE
35
--
36
SPACE
--
--
--
1
- --
---
1
--
--
--
SPACE
37
--
38
SPACE
--
--
--
1
- --
---
i
--
--
--
SPACE
39
--
40
SPACE
--
--
--
1
- --
---
1
--
--
--
ISPACE
41
42
SPACE
--
--
--
i
- --
29.06 TOTAL TOTAL 31.21
TOTAL CONNECTED LOAD: 60.24 KVA
TOTAL CONNECTED WITHOUT CU: 53.99 KVA
TOTAL CONNECTED AMPS =225 AMPS.
** PROVIDE AFCI (ARC- FAULT) BREAKER IN ALL BEDROOMS
AMPS
TYPE: I.T.E. MAIN BUS: 225 AMPS
SERVICE: 10, 3W PANEL B NEUTRAL: FIN
VOLTAGE: 120 f 240 V. 22 KAIC MINIMUM MAIN: M.L.O.
MOUNTING: FLUSH SEE NOTE #5 IN PART 3 IN THIS SHEET LOCATION: GARAGE
K /VOLT
AMP
POLE
TRIP
CONDUIT
WIRE
REMARKS
CKT.
NO.
CKT.
NO.
REMARKS
WIRE
CONDUIT
TRIP
POLE
K /VOLT
AMPS.
12.50
2
60
1"
#8
AHU #2
1
2
CU #2
#10
1"
30
2
8.25
3
4
1.08
1
20
1/2"
#12
LIGHTS
5
6
RECEPTACLES
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
LIGHTS
7
8
GENERAL LIGHTS AFCI '•
#12
1/2"
20
1
1.0,8
1.08
1
20
1/2"
#12
LIGHTS
9
10
LIGHTS
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
GENERAL LIGHTS
11
12
RECEPTACLES
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
RECEPTACLES AFCI •'
13
14
RECEPTACLES
#12
1/2"
20
1
1.08
1.08
1
20
1/2"
#12
GENERAL LIGHTS AFCI **
15
16
BATH GFCI
#12
1/2"
20
1
1.00
1.08
1
20
1/2"
#12
RECEPTACLES AFCI **
17
18
JACUZZI
#12
1/2"
20
1
1.00
1.08
1
20
1/2"
#12
LIGHTS AFCI **
19
20
WATER HEATER
#10
3/4"
30
2
5.00
1.08
1
20
1/2"
#12
RECEPTACLES AFCI **
21
22
1.08
1
20
1/2"
#12
GENERAL LIGHTS AFCI *+
23
24
DRYER
#10
3/4"
30
2
5.00
1.08
1
20
1/2"
#12
LIGHTS AFCI **
25
26
9.40
2
40
3/4"
#8
AHU #3
27
28
GENERAL LIGHTS
#12
1/2"
20
1
1.08
29
30
SPACE
--
--
--
1
- --
6.25
2
30
1"
#10
CU #3
31
32
SPACE
--
--
--
1
33
34
SPACE
-
--
--
1
- --
1.00
1
--
--
--
SPARE
35
36
SPACE
--
--
--
1
- --
---
1
--
--
--
SPACE
37
38
SPACE
--
--
--
1
- --
---
1
--
--
--
SPACE
39
40
SPACE
--
--
--
1
- --
---
i
--
--
--
SPACE
41
42
SPACE
--
--
--
1
- --
41.03 TOTAL TOTAL CONNECTED LOAD: 65.76 KVA TOTAL 24.73
TOTAL CONNECTED WITHOUT CU: 53.26 KVA
TOTAL CONNECTED AMPS =222 AMPS.
** PROVIDE AFCI (ARC- FAULT) BREAKER IN ALL BEDROOMS
op
fi �fj I,
ti
�y
11r NIIs:L F GUTIERREZ, YL, 3360 CORAL she' Y
LIC #049086 SUITE 45 MIAMI 171 >3,`3145
Pry- (300461 --11'3178
'_ ... ` : FA �:: (305 ) =1r.,.1 --62x9
4,
C OA�S'ULTIFeJ{'.P .E14G- 1N.EPR,5, .t'14`c'
2 3 7 7
Ill r
C SULTI
y �Y
w
F. 1'� •
s
IL
V L0
1- Q CD
Z
� N M
w
N o
� _
0 a
00
so
N
W
cr
CE
W
F=• o
�o
t�
J
W
N a V
o�
,'�
ELE07%*�,_
.
P,�
ilitailimp Dm + 1�Y
,
HEE
,mss r
4
a
0
S
S
Z
Z,
C SULTI
y �Y
w
F. 1'� •
s
IL
V L0
1- Q CD
Z
� N M
w
N o
� _
0 a
00
so
N
W
cr
CE
W
F=• o
�o
t�
J
W
N a V
o�
,'�
ELE07%*�,_
.
P,�
ilitailimp Dm + 1�Y
,
HEE
,mss r
4