Loading...
10-285-037PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION FIXTURE UNITS SANITARY LINE — — — — - VENT LINE —� —� SAFEWASTE LINE 3 GATE VALVE - COLD WATER LINE -- HOT WATER LINE P- PLUMBING FIXTURE DESIGNATION AAV AIR ADMITANCE VALVE FCO FLOOR CLEAN OUT I FLOOR PENETRATI ❑N 1/2" MECHANICAL SHOCK T ARRESTOR WC❑ WALL CLEAN ❑UT VTR VENT THRU ROOF 12" DIAMETER CONCRETE PERFORATED AL DRAINAGE OR CLAY PIPE WITHOUT COVER FILLED WITH 3/4" CRUSHED ROCK 0 0 0 0 0 0 0 0 0 0 ° e 0 0 ° ° ° o e e o o ° o 24•" ° ° o 0 ° o ° o o° o A DE 2" CONDENSATE DRAIN LINE FROM BUILDING SEE PLAN PROVIDE 2" GOOSENECK TO SPILL ABOVE GRADE CONDENSATE FRENCH DRAIN DETAIL SHUT -OFF VALVE 3/4" HW SHUT-OFF- VALVE PLUMBING FIXTURE SCHEDULE MARK DESCRIPTION FIXTURE UNITS HOT WATER COLD WATER REMARKS P -1 WATER CLOSET 3 - -- 1/2-1 .84 P -2 LAVATORY 1 1/2' 1/2-1 Q P -3 SHOWER 2 1/2" 1/2" W /ANTI -SCALD VALVE P -4 BATHTUB 2 1/2- 1/2" W /ANTI -SCALD VALVE P -5 KITCHEN SINK 2 1/2" 1/2" Cd P -6 DISHWASHER - -- 1/2" - -- PROVIDE 1" SAFE WASTE P -7 CLOTHWASHER 2 1/2 " �� 1/2 PROVIDE WM BOX W /(2) 1/2 HB & 2 DRAIN REF. REFRIGERATOR N/A N/A 1/2" 1/2" ICE MAKER CONNECTION m Q) 1) FIXTURES TO COMPLY W /FBC 2007 Plumbing Sections 709.1, 603.1, 604.3, & Sections 406 Through 421 2) ANTI -SCALD VALVE: ALL SHOWERS & BATH /SHOWER COMBINATIONS SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERMOSTSTIC MIXING OR COM- BINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 110' F. HORIZONTAL LINE OR CLEANOUT TEE SOIL OR WASTE WAI I CLEAN OU T DETAIL N.T.S. CHROME PLATED BRONZE WALL PLATE PLUMBING GENERAL NOTES AND SPECIFICATIONS: 1. A. SCOPE OF WORK, THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE DRAWINGS, SPECIFIED HEREIN AND/OR AS NEEDED FOR A COMPLETE SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED T ❑1 1, DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2. SANITARY DRAIN AND VENT SYSTEMS 3, PLUMBING FIXTURES AND TRIM 4. PIPING INSULATI ❑N 5.SUPPORTS AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITI ❑N OF THE '2007 FLORIDA BUILDING CODE' AND LOCAL ORDINANCES AND IN COMPLIANCE WITH THE 'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION', AND 'HRS' REGULATIONS, IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT REQUIREMENTS WILL GOVERN, 2. CONTRACTOR TO VERIFY AT SITE THE LOCATI ❑N, ELEVATION AND SIZE OF ALL EXISTING LINES FOR CONNECTI ❑N BEFORE INSTALLATI ❑N OF ANY PIPING. 3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMIN ❑US COMPOUND BEFORE COVERING 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS (ARRESTORS) , 5. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVI ❑US SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC, 6. UNDERGROUND WASTE LINES 3' AND ABOVE TO BE PVC SCH, 40 AND SLOPE @ 1/8'/ FT. WASTE LINES 2' AND UNDER, AND ABOVE GROUND PIPES SLOPE @ 1 /4' /FT. 7. PR ❑VIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTI ❑N, AND AT BOTTOM OF STACKS, CLEAN OUT L❑CATI ❑NS AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE, B. VENT LINES TO EXTEND 9' MIN. ABOVE ROOF AND FLASH WITH LEAD. COORDINATE WITH METAL ROOF SUB - CONTRACT ❑R, 9. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE 'K' ABOVE GROUND TO BE COPPER TYPE 'L'. OR APPROVED CPVC . NO JOINTS ALLOWED UNDERGROUND, 11. PIPING A. SUPPORT ALL PIPE FROM SOUND PORTI ❑NS OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE. B. PR ❑VIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES, C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PR ❑VIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES, PR ❑VIDE CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. 12. INSPECTIONS AND TESTS A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTI ❑NS TO THE AUTHORITIES HAVING JURISDICTI ❑N, AS THE WORK PROGRESSES. ALL SYSTEMS SHALL BE TESTED BY CODE AND /OR LOCAL REGULATI ❑NS, B. DRAINAGE PIPING= BEFORE INSTALLATI ❑N OF ANY DRAINS, THE ENDS OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY A BUILDING INSPECT ❑R. 13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER C❑MPLETI ❑N OF THE INSTALLATION, / 1s-- " DRYER 1/2 / (30 MBTU/H) I GIWH 1.. I • . u I � (1 99 MBTU/H) 12j i 1 GAS FOR CONT. SEE CW SITE PLAN INSTANTANEOUS GAS W ATEfR PEATER NTS GAS W ATEIR HEATER SCHEDULE MODA=L MANUFACTURER HOT WATER CAPACITY (MIN. -MAX.) GAS CONSUMPTION B TU /H. (MIN. -MAX.) PIPE M=ATTING EF R -94LSi RINNAI 0.6 - 9.4 GPM 15 - 199 MBTU 3/411 .84 cd ' 0 d o r�_4r W b cD N - Q HP LINE FROM CITY 8• PRESSURE REG. \ I GAS METER SOV_/ SLEEVE THRU WALL GAS NOTES MAXIMUM LOAD: 429 MBTU/H LONGEST RUN: 57 FT. GAS TYPE: NATURAL 1" 4" \ IN 28' 3 . / \ RANGE (100 MBTU /H) NOTES u 1. USE THE FLORIDA BUILDING CODE -FUEL GAS TABLE 402.4(2) TO DETERMINE PIPE SIZES. 2. USE METALLIC PIPE FOR EQUIPMENT CONNECTION. GAS PIPING ISOMETRIC NTS ,, ,,,.,C3/41p IN t - -3/4" 6'I GRILL (100 MBTU /H) 'Iglu \l :7 e'. G 1' o n G� 2'i r ?, ••':LEONARDO NAVEIRAS, INC. .- ,901VSULTING ENGINEERS" - C� eonardo Naveiras P.M. CA# 25830 �'• -JGlio C. Vidal P.E. PE# 52792 ,�.._. ����'�� * • • 198 Harrison St # 207 Hollywood, FL 33020 Phone: 954-270-4822 Fax. 954-241-6850 E -mail: hvacleo @aol.com '7 `1;F111 1 \ \1 REVISIONS No. TrIT.E DATE ISSUANCES DATE TITLE 0 /08/09 SITE PLAN APPROVAL P &Z CONNENTS HID PERMIT CONSTRUCTION THE USE OF THESE PLANS AND SPECIF- ICATIONS SHALL HE RESTRICTED TO THE ORIGINAL SITE FOR TIM THEY WERE PREPARED AND PUBLICATION THEREOF IS EM MY IWTED TO SUCH USE. REPRODUCTION. PUBLICATION OR RE -USE BY ANY MIDI), IN WHOLE OR IN PART, WITHOUT ZMESS WRITTEN CONSENT HT THE ARCHITECT ]S STRICTLY PROHIMM. TITLE TO THE PINS AND SPRi@IIYTRONS REMAINS WITH THE ARMMCT WITHOUT PREJUDICE. VISUAL CONTACT WITH THIS PLANS AND SPECIFICATIONS SHAIL CONSTITOTE PRDIA FASCIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS SCALE LNI N U +� U� N JV Fd 4 �D O cd ' 0 d o r�_4r W b cD N - Q cd � W CO 0 Cd 0 0 a N C x E-1 z a w Cd v CYJ N pq THE USE OF THESE PLANS AND SPECIF- ICATIONS SHALL HE RESTRICTED TO THE ORIGINAL SITE FOR TIM THEY WERE PREPARED AND PUBLICATION THEREOF IS EM MY IWTED TO SUCH USE. REPRODUCTION. PUBLICATION OR RE -USE BY ANY MIDI), IN WHOLE OR IN PART, WITHOUT ZMESS WRITTEN CONSENT HT THE ARCHITECT ]S STRICTLY PROHIMM. TITLE TO THE PINS AND SPRi@IIYTRONS REMAINS WITH THE ARMMCT WITHOUT PREJUDICE. VISUAL CONTACT WITH THIS PLANS AND SPECIFICATIONS SHAIL CONSTITOTE PRDIA FASCIE EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS WRLIAM L. CATE. ARC= AR0016785 DRAWN BY SCALE LNI AS NOTED +� U� DATE - JV 0 4 Id o L) co Ln I z U co Cd v CYJ N pq cm coo � L m Q) WRLIAM L. CATE. ARC= AR0016785 DRAWN BY SCALE LNI AS NOTED CHEC BY DATE - JV 02 -08 -10 SHEET NUMBER P-2 2 C: \gambardella J �.