10-285-032STRUCTURAL GENERAL NOTES: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL DRAWINGS, SHOP DRAWINGS AND SPECIFICATIONS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF RECORD PRIOR TO CONSTRUCTION. ANY VARIATIONS IN ACTUAL FIELD CONDITIONS AND DIMENSIONS FROM THOSE SHOWN ON THE CONTRACT DOCUMENTS (DRAWINGS) SHALL BE REPORTED TO THE ENGINEER FOR DETERMINING THE NEED OF REDESIGN PRIOR TO CONSTRUCTION. COORDINATE ALL OPENINGS, CHASES, SLEEVES, ITEMS TO BE EMBEDDED IN CONCRETE WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE BRACING AND SHORING OF STRUCTURAL MEMBERS, WALLS AND NON— STRUCTURAL ITEMS DURING CONSTRUCTION, AS REQUIRED, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN AND INSURE THE INTEGRITY OF THE STRUCTURE AT ALL STAGES OF CONSTRUCTION. ALL STRUCTURAL WOOD AND SHEATHING SHALL BE IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION, UNLESS OTHERWISED NOTED WOOD MEMBERS SHALL BE SOUTHERN PINE No.1 OR BETTER. GLULAM BEAM SHALL BE DOUGLAS FIR WITH THE FOLLOWING MIMINUM PROPERTIES: Fb = 3000 PSI Fv = 300 PSI E = 2.1 X 10"6 PSI SHOP DRAWINGS: PRIOR TO ANY FABRICATION, ALL SHOP DRAWINGS FOR REINFORCING STEEL,STRUCTURAL STEEL AND WOOD TRUSSES SHALL BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL FOR PROFESSIONAL CERTIFICATION, TO BE SIGNED & SEALED BY REGISTERED ENGINEER IN THE STATE OF FLORIDA. TYPICAL DETAILS: UNLESS OTHERWISE NOTED, DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. ARCHITECTURAL DRAWINGS: SEE ARCHITECTURAL DRAWINGS FOR LOCATION, DIMENSIONS, ELEVATIONS AND FINISH DETAILS FOR ALL WALKWAYS AND OTHER EXTERIOR SLABS ON GRADE NOT SHOWN ON STRUCTURAL DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR SLAB FINISHES AND DETAILS. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF DEPRESSED SLAB AREAS AND FLOOR DRAINS. HORIZONTAL JOINT: REINFORCING SHALL BE #9 GAGE LADDER TYPE AT 16 INCHES ON CENTER (DUR —O —WALL OR SIMILAR) STRUCTURAL STEEL STRUCTURAL STEEL FABRICATION SHALL BE BASED ON THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS ". 1— TYPE OF MEMBER ASTM SPEC. FY A— PLATES, SHAPES, A50 50KSI ANGLES & RODS B— STRUCTURAL TUBING ASTMA -500 46KSI C— ANCHOR BOLTS A307 UNLESS EMBEDDED IN OTHERWISE NOTED) D— CONNECTION BOLTS A325F (UNLESS (3/4" UNLESS SHOWN OTHERWISE NOTED) E— EXPANSION BOLTS- - HLTI KWIK 3 EXPANSION BOLTS WELDING: WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL BE PERFORMED BY CERTIFIED WELDERS. USE E70XX ELECTRODES. ALL WELDS SHALL BE 3/16" MINIMUM, UNLESS OTHERWISE NOTED. CONNECTIONS: SHOP AND FIELD CONNECTIONS SHALL BE HIGH STRENGTH BOLTS OR BY WELDING, AND BOLTED CONNECTIONS SHALL BE DETAILED FOR MAXIMUM END REACTION OF SUPPORTED END ELEMENTS, ALL WELD SHALL DEVELOP THE FULL STRENGTH OF MEMBERS TO BE WELDED. PAINT: ALL STRUCTURAL STEEL TO BE SHOP PRIMED W/ "GRAY" RUSTOLEUM AND ONE COAT OF FIELD GREY RUSTOLEUM. SUMMARY OF SPECIAL INSPECTION: DESCRIPTION OF TYPE OF INSPECTION REQUIRED LOCATION, REMARKS, ETC. CONCRETE MASONRY UNITS SHALL BE LOAD BEARING GRADE N -1 UNITS HAVING A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI, CONFORMING TO ASTM C90 FOR RESULTING F'M NOT LESS THAN 1500 PSI. USE 2 CELL HOLLOW CMU UNITS FOR ALIGNMENT OF WEBS, AS PER ACI 530, ACI 530.1 MAXIMUM LIFT: 4' -0" MORTAR AND GROUT COMFORMING TO ASTM —C476 WITH A 8" TO 1 1 " MIN. SLUMP. RAAnT A n SHALL CONFORM TO ASTM C -270, TYPE M WITH A COMPRESSIVE STRENGTH OF 2500 PSI ON THE NET AREA AT 28 DAYS. GROUT: SHALL BE CONCRETE CONSISTING OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO GRADING SIZE NUMBER 8 OF ASTM C33, TYPE: PORTLAND CEMENT CONFORMING TO ASTM C150. AND SHALL HAVE A COMPRESSIVE STRENGTH (F'C) OF 3000 PSI AT 28 DAYS. REINFORCING STEEL 1— REINFORCING STEEL: SHALL CONFORM TO ASTM A615 -75, GRADE 60, FY = 60,000 P.S.I. 2— POSITION VERTICAL REINFORCING STEEL IN EXACT CENTER OF FILLED CELLS OR AS SHOWN. PLACE GROUT IN LIFTS NOT TO EXCEED 4' -0" IN HEIGHT. PROVIDE VERTICAL BARS AT ALL CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE TWO #6 FULL HEIGHT EACH SIDE OF OPENINGS AND AT DISCONTINUOUS END OF ALL MASONRY WALLS AND GROUT SOLID FULL HEIGHT UNLESS OTHER WISE NOTED . PROVIDE CLEANUPS AT BOTTOM OF EACH POUR 3— DETAILING: REINFORCING STEEL SHALL BE DETAILED ( INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315 -05 AND 318 -05. LAP ALL CONTINUOUS REINFORCEMENTS 48 BAR DIAMETERS. PROVIDE BARS AT ALL WALL INTERSECTIONS NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. WELDING OF REINFORCING STEEL SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES, AND IN ACCORDANCE WITH AWSD12 -75, REINFORCING STEEL WELDING CODE. 4— EXTEND HORIZONTAL BARS AT LEAST LAP DISTANCE AND VERTICAL BARS THE FULL STORY, OR BOTH, AS FAR AS POSSIBLE AND HOOK. 5— PROTECTION OF REINFORCING STEEL: CONCRE E COVER INCHES) A— FOOTING AND OTHER UNFORMED SURFACES, EARTH FACE 3" B— FORMED SURFACES IN DIRECT CONTACT WITH EARTH 2" C— BEAMS, COLUMNS, AND SURFACES EXPOSED TO WEATHER (TO TIES AND STIRRUPS) 1-1/2" D— SLABS AND WALLS (INTERIOR FACE) UNLESS OTHERWISE NOTED 1" 6— ALL REINFORCING STEEL SHALL BE SECURELY HELD IN PLACE FOR CONCRETE PLACEMENT. ADDITIONAL BARS OR STIRRUPS SHALL BE PROVIDED FOR SUPPORT OF ALL BARS AS REQUIRED. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE OF FLORIDA OF THE FOLLOWING ITEMS TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO CONSTRUCTION: A) REINFORCING STEEL B) STRUCTURAL STEEL C) PREFABRICATED WOOD TRUSSES. THESE DRAWINGS AND SPECIFICATIONS COMPLY, TO THE BEST OF MY KNOWLEDGE WITH THE APPLICABLE MINIMUM FLORIDA BUILDING CODE 2007 REQUIREMENTS. 2. 3. 4, 5. 7. PREFAB- WOOD TRUSSES: 1. DESIGNED AND FABRICATED IN ACCORDANCE WITH 'NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADE LUMBER AND ITS FASTENERS' BY NFPA AND THE TRUSS PLATE INSTITUTE (TPI) (LATEST REVISION), TRUSSES SHALL BE DESIGNED, SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER WHO SHALL BE ASSIGNED AS A DELEGATED ENGINEER FOR THE CONTRACTOR.THE DELEGATED ENGINEER SHALL DESIGN AND INDICATE ON THE SHOP DRAWINGS ALL TRUSS COMPONENTS, TEMPORARY BRACING, BRIDGING, HARDWARE. METAL HANGERS, ANCHORS AND METAL SHAPES AS REQUIRED BY DESIGN OR AS INDICATED ON THE PLANS. ALL METAL PARTS TO BE GALVANIZED. TRUSS DESIGNER ENGINEER SHALL INDICATE THE NET WIND UPLIFT AND GRAVITY LOAD REACTIONS FOR EACH TRUSS AND GIRDER TRUSS. STRAPS SHALL BE PROVIDED FOR EACH TRUSS BEARING, BASED ON THE UPLIFT COMPUTATIONS INDICATED ON THE TRUSS SHOP DRAWINGS AND THE FOR APPROVED PLANS. CONTRACTOR SHALL USE LONG ENOUGH STRAPS, TO ALLOW STAGGERING OF THE NAILS AND CLEARING THE STEEL SPIKE PLATES (TRUSS JOINT CONNECTION). ALL SEATS FOR THE WOOD GIRDER TRUSSES WILL BE DESIGNED BY A/E AND WILL BE COMPLETED AFTER RECEIVING THE PRE — ENGINEERED WOOD TRUSS SHOP DRAWINGS, SHOWING LOCATIONS OF GIRDERS AND END REACTIONS AT THEIR BEARING POINTS. THE STRUCTURAL PLANS INDICATE ALL THE REQUIRED LATERAL PERMANENT BRIDGING, AS RECOMMENDED BY THE 'TRUSS PLATE INSTITUTE'. TRUSS DESIGNER ENGINEER SHALL PROVIDE INFORMATION AND SHOW ON PLAN, ALL LATERAL BRACING OF ANY TRUSS INDIVIDUAL MEMBERS, AS REQUIRED BY TRUSS DESIGN. INSTALLATION OF TRUSSES LONGER THAN 35 FT. OR HIGHER THAN 6 FT. SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A LICENSED BUILDING OR GENERAL CONTRACTOR AND A LICENSED STRUCTURAL ENGINEER OR ARCHITECT. TEMPORARY BRACING SHALL BE REQUIRED DURING THE ERECTION OF ROOF TRUSSES TO KEEP THE TRUSSES IN A TRUE AND PLUMB POSITION AND TO PREVENT TOPPLING OF THE TRUSSES DURING ERECTION, UNITIL THE ROOF SHEATHING IS APPLIED. CITBUILDING DEPT. STRUCTVRAti/"�7lo" WPR13VE0EY:— V ABRAHAM ARVELO. P, CT ARVELO AND ASSOCIATES, IN 3 # 3es�s STRUCTURAL ENGINEE�S u 4848 SW 74th CT., MIAMI, FL S ' (305) 667 -7628 CERTIFICATE# EB -DOOT 21 • • • E%L ISSUANCES DATE TITLE 10/08/09 SITE PLAN APPROVAL PAZ COMMENTS BID T ?E[D[[T CONSTRUCTION 1) SPECIAL PLACING INSPECTION BY TESTING LABORATORY REQUIRED DESIGN CRITERIA U� FOR ALL FOUNDATION AND CONCRETE . GOVERNING BUILDING CODE: WIND VELOCITY: 146 MPH 2) SPECIAL INSPECTION BY OWNER'S REPRESENTATIVE OR TESTING LAB FLORIDA BUILDING CODE 2007 PER ASCE 7 -05 STANDARDS. U1 REQUIRED FOR ALL BUILDINGS AND SITE PAVING CONCRETE SLAB ON DESIGN LOADS: EXPOSURE "C" BUILDING CATEGORY 2 to � � GRADE. A) LIVE LOADS: IMPORTANCE FACTOR =1.0 INTERNAL PRESSURES COEFFICIENTS: 3) ALL STRUCTURAL WELDING OR CONNECTION SHALL BE INSPECTED BY ROOF = 30 PSF INTERNAL PRESSURES COEFFICIENTS: ct Tn L7 � QUALIFIED TESTING LAB UPON COMPLETION REPORT OF INSPECTION a� AND COMPLIANCE TO BE FILED WITH BUILDING DEPARTMENT BY THE B) S.I. DEAD LOADS = 20 PSF GCPi= +0.18 L) U F o TESTING LAB. GCPi = -0.18 � z REFER TO S -2 FOR NET UPLIFTS Kd =1.0 4) ALL BOLTED CONNECTIONS SHALL BE INSPECTED BY TESTING LAB OR ;.., co QUALIFIED INSPECTOR AND FINAL INSPECTION AND COMPLIANCE SOIL STATEMENT: V REPORT TO BE SUBMITTED TO THE OWNER. c 5) ALL ROOF SYSTEM SHALL BE INSPECTED BY QUALIFIED INSPECTOR THE ENGINEER HAS VISITED & OBSERVED THE SITE AND FOUND THE CD AND FINAL INSPECTION AND COMPLIANCE REPORT TO BE SUBMITTED FOUNDATION CONDITIONS' ARE SAND AND LOOSE ROCK WHICH ARE SIMILAR TO THE TO THE OWNER OR MANUFACTURER. DESIGN BASIS. FURTHERMORE, UPON BREAKING OF GROUND, A 6) GEOTECHNICAL ENGINEER TO VERIFY ALL SOILS AND FOUNDATIONS LETTER SHALL BE SUBMITTED TO THE BUILDING OFFICIAL VERIFYING CONDITIONS AS PER GEOTECHNICAL REPORT AND EARTHWORK NOTES OF AND ATTESTING THAT THE SITE CONDITIONS ARE SIMILAR TO THOSE a� THIS SPECIFICATIONS. WHICH THE DESIGN WAS BASED ON ASSUMED BEARING CAP. OF 2000 P.S.F. 7) ALL CONCRETE SLABS, BEAMS, COLUMNS, FOOTINGS AND WALLS. CONCRETE THE CONTRACTOR SHALL COMPLY WITH ALL THE MANUFACTURER'S SUMMARY OF CONTRACTORS SUBMITTALS TO EOR: AND MATERIAL SPECIFICATIONS. ALL CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI 301 -05 SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR 1) CONCRETE MIX DESIGN BY TESTING LABORATORY REQUIRED BUILDINGS. STRUCTURAL CONCRETE SHALL BE NORMAL WEIGHT FOR ALL FOUNDATION AND CONCRETE STRUCTURE . CONCRETE CONFORMING TO ACI 318 -05 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 2) SIGNED AND SEALED RAILINGS SHOP DRAWINGS DAYS.(U.A.N.), CONCRETE SLUMP 3" + 1 " FOR FOOTINGS AND AND CALCULATIONS BY A FLORIDA REGISTERED ENGINEER. SLAB ON FILL, AND 4" + 1 " FOR ALL OTHER CONCRETE. MAKE PRIOR TO FABRICATION. SLUMP TESTS WHEN CYLINDERS ARE MADE AND AT OTHER TIMES 3) SIGNED AND SEALED PREFAB WOOD TRUSSES SHOP DRAWINGS AS NECESSARY TO VERIFY SLUMP. AND CALCULATIONS BY A FLORIDA REGISTERED ENGINEER. PRIOR TO FABRICATION. SLAB REINFORCING: ALL SLABS ON GRADE SHALL BE REINFORCED AS CALLED FOR ON DRAWINGS OR SPECIFICATIONS. MASONRY NOTES: CONCRETE MASONRY UNITS SHALL BE LOAD BEARING GRADE N -1 UNITS HAVING A MINIMUM COMPRESSIVE STRENGTH OF 1900 PSI, CONFORMING TO ASTM C90 FOR RESULTING F'M NOT LESS THAN 1500 PSI. USE 2 CELL HOLLOW CMU UNITS FOR ALIGNMENT OF WEBS, AS PER ACI 530, ACI 530.1 MAXIMUM LIFT: 4' -0" MORTAR AND GROUT COMFORMING TO ASTM —C476 WITH A 8" TO 1 1 " MIN. SLUMP. RAAnT A n SHALL CONFORM TO ASTM C -270, TYPE M WITH A COMPRESSIVE STRENGTH OF 2500 PSI ON THE NET AREA AT 28 DAYS. GROUT: SHALL BE CONCRETE CONSISTING OF NATURAL SAND FINE AGGREGATE AND NORMAL WEIGHT COARSE AGGREGATES CONFORMING TO GRADING SIZE NUMBER 8 OF ASTM C33, TYPE: PORTLAND CEMENT CONFORMING TO ASTM C150. AND SHALL HAVE A COMPRESSIVE STRENGTH (F'C) OF 3000 PSI AT 28 DAYS. REINFORCING STEEL 1— REINFORCING STEEL: SHALL CONFORM TO ASTM A615 -75, GRADE 60, FY = 60,000 P.S.I. 2— POSITION VERTICAL REINFORCING STEEL IN EXACT CENTER OF FILLED CELLS OR AS SHOWN. PLACE GROUT IN LIFTS NOT TO EXCEED 4' -0" IN HEIGHT. PROVIDE VERTICAL BARS AT ALL CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE TWO #6 FULL HEIGHT EACH SIDE OF OPENINGS AND AT DISCONTINUOUS END OF ALL MASONRY WALLS AND GROUT SOLID FULL HEIGHT UNLESS OTHER WISE NOTED . PROVIDE CLEANUPS AT BOTTOM OF EACH POUR 3— DETAILING: REINFORCING STEEL SHALL BE DETAILED ( INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315 -05 AND 318 -05. LAP ALL CONTINUOUS REINFORCEMENTS 48 BAR DIAMETERS. PROVIDE BARS AT ALL WALL INTERSECTIONS NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. WELDING OF REINFORCING STEEL SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES, AND IN ACCORDANCE WITH AWSD12 -75, REINFORCING STEEL WELDING CODE. 4— EXTEND HORIZONTAL BARS AT LEAST LAP DISTANCE AND VERTICAL BARS THE FULL STORY, OR BOTH, AS FAR AS POSSIBLE AND HOOK. 5— PROTECTION OF REINFORCING STEEL: CONCRE E COVER INCHES) A— FOOTING AND OTHER UNFORMED SURFACES, EARTH FACE 3" B— FORMED SURFACES IN DIRECT CONTACT WITH EARTH 2" C— BEAMS, COLUMNS, AND SURFACES EXPOSED TO WEATHER (TO TIES AND STIRRUPS) 1-1/2" D— SLABS AND WALLS (INTERIOR FACE) UNLESS OTHERWISE NOTED 1" 6— ALL REINFORCING STEEL SHALL BE SECURELY HELD IN PLACE FOR CONCRETE PLACEMENT. ADDITIONAL BARS OR STIRRUPS SHALL BE PROVIDED FOR SUPPORT OF ALL BARS AS REQUIRED. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SIGNED AND SEALED BY A REGISTERED ENGINEER IN THE STATE OF FLORIDA OF THE FOLLOWING ITEMS TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO CONSTRUCTION: A) REINFORCING STEEL B) STRUCTURAL STEEL C) PREFABRICATED WOOD TRUSSES. THESE DRAWINGS AND SPECIFICATIONS COMPLY, TO THE BEST OF MY KNOWLEDGE WITH THE APPLICABLE MINIMUM FLORIDA BUILDING CODE 2007 REQUIREMENTS. 2. 3. 4, 5. 7. PREFAB- WOOD TRUSSES: 1. DESIGNED AND FABRICATED IN ACCORDANCE WITH 'NATIONAL DESIGN SPECIFICATIONS FOR STRESS GRADE LUMBER AND ITS FASTENERS' BY NFPA AND THE TRUSS PLATE INSTITUTE (TPI) (LATEST REVISION), TRUSSES SHALL BE DESIGNED, SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER WHO SHALL BE ASSIGNED AS A DELEGATED ENGINEER FOR THE CONTRACTOR.THE DELEGATED ENGINEER SHALL DESIGN AND INDICATE ON THE SHOP DRAWINGS ALL TRUSS COMPONENTS, TEMPORARY BRACING, BRIDGING, HARDWARE. METAL HANGERS, ANCHORS AND METAL SHAPES AS REQUIRED BY DESIGN OR AS INDICATED ON THE PLANS. ALL METAL PARTS TO BE GALVANIZED. TRUSS DESIGNER ENGINEER SHALL INDICATE THE NET WIND UPLIFT AND GRAVITY LOAD REACTIONS FOR EACH TRUSS AND GIRDER TRUSS. STRAPS SHALL BE PROVIDED FOR EACH TRUSS BEARING, BASED ON THE UPLIFT COMPUTATIONS INDICATED ON THE TRUSS SHOP DRAWINGS AND THE FOR APPROVED PLANS. CONTRACTOR SHALL USE LONG ENOUGH STRAPS, TO ALLOW STAGGERING OF THE NAILS AND CLEARING THE STEEL SPIKE PLATES (TRUSS JOINT CONNECTION). ALL SEATS FOR THE WOOD GIRDER TRUSSES WILL BE DESIGNED BY A/E AND WILL BE COMPLETED AFTER RECEIVING THE PRE — ENGINEERED WOOD TRUSS SHOP DRAWINGS, SHOWING LOCATIONS OF GIRDERS AND END REACTIONS AT THEIR BEARING POINTS. THE STRUCTURAL PLANS INDICATE ALL THE REQUIRED LATERAL PERMANENT BRIDGING, AS RECOMMENDED BY THE 'TRUSS PLATE INSTITUTE'. TRUSS DESIGNER ENGINEER SHALL PROVIDE INFORMATION AND SHOW ON PLAN, ALL LATERAL BRACING OF ANY TRUSS INDIVIDUAL MEMBERS, AS REQUIRED BY TRUSS DESIGN. INSTALLATION OF TRUSSES LONGER THAN 35 FT. OR HIGHER THAN 6 FT. SHALL BE PERFORMED UNDER THE DIRECT SUPERVISION OF A LICENSED BUILDING OR GENERAL CONTRACTOR AND A LICENSED STRUCTURAL ENGINEER OR ARCHITECT. TEMPORARY BRACING SHALL BE REQUIRED DURING THE ERECTION OF ROOF TRUSSES TO KEEP THE TRUSSES IN A TRUE AND PLUMB POSITION AND TO PREVENT TOPPLING OF THE TRUSSES DURING ERECTION, UNITIL THE ROOF SHEATHING IS APPLIED. CITBUILDING DEPT. STRUCTVRAti/"�7lo" WPR13VE0EY:— V ABRAHAM ARVELO. P, CT ARVELO AND ASSOCIATES, IN 3 # 3es�s STRUCTURAL ENGINEE�S u 4848 SW 74th CT., MIAMI, FL S ' (305) 667 -7628 CERTIFICATE# EB -DOOT 21 • • • E%L ISSUANCES DATE TITLE 10/08/09 SITE PLAN APPROVAL PAZ COMMENTS BID T ?E[D[[T CONSTRUCTION THE USE OF THESE PLANS AND SPEC7 ICATIONS SHAH. BE RESTRICPBD TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS E aIMSSLY LIT = TO SUCH USE. REPRODUCTION, PUBLICATION OR RE -USE BY ANY NETIM. IN WHOLE OR IN PART', ■ THOUT Kamm WRTTm C0?MNT BY THE ARCHITECT IS STRICTLY PROIOBLTED. TTTTE TO THE PLANS AND SPECOICATIONS RENADIS WRS THE ARCHITECT WITHOUT PRE7UDICE. VISUAL CONTACT WITH IBM PLANS AND SPECIFICATIONS MALL CONSTTTUT•E PRW FASCIB EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS. Q) WLC s� U� to WLC .ul 0 Q) p!b SHEET NUMBER S-12 � 0 U1 cd �o• H to � � O Z Lid CO 0 Co ct Tn L7 � C� a� Ems-+ L) U F o E P4 � z b�C\2 THE USE OF THESE PLANS AND SPEC7 ICATIONS SHAH. BE RESTRICPBD TO THE ORIGINAL SITE FOR WHICH THEY WERE PREPARED AND PUBLICATION THEREOF IS E aIMSSLY LIT = TO SUCH USE. REPRODUCTION, PUBLICATION OR RE -USE BY ANY NETIM. IN WHOLE OR IN PART', ■ THOUT Kamm WRTTm C0?MNT BY THE ARCHITECT IS STRICTLY PROIOBLTED. TTTTE TO THE PLANS AND SPECOICATIONS RENADIS WRS THE ARCHITECT WITHOUT PRE7UDICE. VISUAL CONTACT WITH IBM PLANS AND SPECIFICATIONS MALL CONSTTTUT•E PRW FASCIB EVIDENCE OF THE ACCEPTANCE OF THESE RESTRICTIONS. L. CATE ARCHITEC AR001085 DRAWN BY SCALE WLC AS NOTED U� DATE WLC Nil SHEET NUMBER S-12 co .,..� Lid C� z o co U u I � z b�C\2 ;.., co U cd CIO V co c CD U I4 a a� L. CATE ARCHITEC AR001085 DRAWN BY SCALE WLC AS NOTED CHECKED BY DATE WLC 12.01.09 SHEET NUMBER S-12