Loading...
10-359R-003AIP CON0I7"I0NING '50-IEDULE UNIT MANUFACTURER AND MODEL NO, NOM, 7-ON-5 NOM. GFM ESP /N. WG. HEATING GAP. OTUtl a 41 "F DD tiSPF TOTAL FLA/l1P I7GA1 COOLING GAP, 5/T O7­Ul1 o 95° $ 61° W O/A GFM D/MEN510N5 WxLxl1 CINd WEIGtfi L05. ELECT. SERVICE VOL7-5 1P11 /i1z SEER AtI.U. ! •Rt1EEM/ Rt1PL- t1M4824 - -_____ 1600 .40 _______ 9.5 221//2 - - -__ _________________ _ ___ __ __ -_- 21 X 22X35 98 208-230/1/60 16.0 COMP. I Rl1EEI7/ RPRL- 048JEZ 40 ------ __ -____ 44,500 `� 5 28/45 35,100 / 49,00 ~ ~- 32 X 45 X 33 308 208 - 230/1/60 16.0 I IF14N SGtljffUULf Maxifwn tlan4cr MANUFACTURER 5pacirq 48: Widc or giolcr 4 ft ELEGr.SERVIGE DIMEN5/ON WEl6tfi 5MOKia DAM M-15) FAN # AND MODEL NO. l� PM WATTS GFM 8"5F. VOLTS /Ptl /nz WxLxH (/N.) x 1'EMA!'K5 TOILET dcpth of lcys SMOKE wNrFOL x W/ GRILLE, 4" - DUCT EX. FAN GROAN/ 618 1500 /00 5500118" 115///60 8X8X6 DAMPEI' 1'001= GAP AIP GOND17- 10N1NG 5Y57-,ff 1'I - GENEPAL- NOTES: 1. DUGTWORK St lALL PE StIEEr METAL INSULATED W11112" rtlrGK, 5 P5F DENSITY FVERGLA55 Wlrtl VAPOR PARRIES ROUND DUGT TOPE INSULATED TtlERMOFIN' AL ALLOY. DUCTWORK 511ALL BE FAPRrGArED AND INSTALLED IN AGW PDANGF W17-H MANUFAG7-URE,P'5 5PEGIFIGA7-10N5 AND ACCORDING 7-0 "A5t1RAE" AND "SMAGNA" STANDARDS. DUGT DIMEN510N5 ARE IN INCHES AND CORRESPOND TO IN51DE DIMEN510N5 WI0771 Xt1EI6t r DUG7- 5Y5TEM5t1ALL COMPLY W17-11 "NFPA" STANDNRD NO. 90AAND /OR 90P. OUGTWORK AND GOMPONENr5 SttALL PE GLA551 MATERIALS IN AGGORDANGE Wtrtl UL. 181 TESTS. 2, GOORDINATE LOCATIONS, 51ZE5 AND OPENINGS Wlrtl O-WE,P TRADES ON TtIE JOP. A/G COMMAGTOR StIALL PROVIDE 771E COMPLETE DUGr SYSTEM A/G GONTRAGTOiP StlALL USE rtlE PEST PRACrCES OF Tt1E TRADE IN Tl1E FAfWCATION AND INSTALLATION OF THE 5Y5TEM, -5 DIFFUSERS StlALL BE 5ELOGTED, LOGArED, AND PALANGED IN ORDER Ti1A7- 7-HEY DELVER TtIE REOUIRED GFM TO TtiE ENTIRE ROOM EVENLY AND DRAFT FREE TO MNNTN/N Tt1E FOLLOWING DE51GN GONG ASWN 5: IN51DE . OUTSIDE MLATVE HUMIDITY GOOLIN6 - 76 DP 91 DP - 79 WP 507. TO 607. MEArING - 70 DP 47^ - DP 4. ALL FAN UNIrS, MOTORS, GOMPRE550R5, ETG. StlALL PE 1501-ArED, A5 REQUIRED TO OPERATE QUIETLY 50 TMAr N00PJEGr10N1WLE 50UND WILL PE tIEARD IN rt1E HAPIrAPLE SPADES DUE TO NR VELOGIrY, MOTOR MUM, VIBRATION, OR MEGH1WCA - MOVEMENT �. A/G SYSTEM 5t1ALL HAVE GLEANABLE NR FILTERS LOGATED A5 REQUIRED FOR EASY AGGE551011-n, 6. A/G SYSTEM 5t1AL - PE GONTROLLED PY A PROGRAMADLE 7t1ERM057A7. MOUNT 7-tlFPM057-A7- V -0" APOVE FINIStIED FLOOD UON. 7. ALL GRILLS AND DIFFU5ER5 TO BE ALUMINUM OR STEEL G0NSrRUGT10N. DIF- FUSERS TO HAVE OP05ED PLADE DAMPERS, PROVIDE 6115KEr5 ON ALL GRILLES AND DIFFUSERS. TlrUS OR Miff WIVE OK APPROVED EOUAL WAIT// ENAMEL FINI5t1 8, UNDEMJr DOORS l" AFF., A5 INDICATED. 9. ALL iPEFRIGERANT PIPING 5t1ALL BE GOPPER - TYPE L - AGR TYPE, DEtIYDRATED AND SEALED. ALL FIMN55 5t1ALL PE WROUGtrr COPPER. ALL J01Nr5 5t1ALL PE MADE Wtrtl t1/GM TEMPERATURE BRAZING NLLOY OF NOT LE55 THAN 51 5ILVER. PIPING INSTALLATION NOr LE55 TtIAN 314" TMEK "ARMAFLEX LIOUID AND SUCTION UNES SMAL!- BE SIZED ACCORDING TO EOUIPMEW MANUFA, -7V PER'S REGOMMENDA7-l0NS FOR EQUIVNLENr LENGTM OF PIPING RUN FOR CONNEGTED TONNAGE ALL PIPING ACGE550RIE5 SMALL DE GON57RUG7-ED A5 SUGGESTED BY EOUIPMENr MANUFACTUREP ALL PIPING SMALL PE EVACUATED PER GOOD PIPING PRACTICE PEFORE 5TART -UP. 51-A55 DUCT (R -6) R W/LOCK/NG OUADRANT ROOF GAP. FLEXIBLE OUGr I \" FIBERGLASS WELENE JACKET AND STEEL WIRE (G DIFFUSER TY IG/t� P1FI':�U5ff CONNEcrION PE7 -All- NO 5GAL -F STANDARD 3" WIDE HANGERS Ilan ld extennlon to be the --xim of the Anlanee-, belween the hanging wire and the duct slzc /D (Snvacna) Duct -->izc Inchc-> Maxifwn tlan4cr NO 5pacirq 48: Widc or giolcr 4 ft L-c" tha 48" widc 6ft and lcr3 than 48" 5MOKia DAM M-15) deep X Width belween 28" Eft ff 46" and grealer FIIPE RATED ROOFIFI.009 GMUNG A55EMPI -Y Ikon l6" dccp x rza;o� on 29" wic 8ft dcpth of lcys SMOKE wNrFOL GtlANNEL SECTION If Told 17inifwfr 17inlfwn rVennion i5 Channel Channel not grealer than: Gavgc Profile 6" Z4 3" X 1.5" l8" 22 3" X 2" 30" l8 3" X 2" CONDENSING UNIT MOUNTED I' USE OF 2" WIDE Z2 gaugc 2'x /.5" hangcr� may be 9ub�filulcd PROVIDE 2 -2 GALV. 5TRAP5 90 deg. FROM for 3" ho�a� for ducts with widths not over 48" PIPE /N5UMI -ION EA OTt1ER TO SECURE i10051NG OF GU ROVIDE 4 -1/4" rAPCON SGREWS AT EA. and dcpth-, nol over 24" provided /hat not fore END OF STRAP. Al-5D PROV /DD 4 TURNPUGKLES than one joint occurs brlween harger-> and Ihe GAULK W /3M GP-25 OR EQUAL r0 L005EN 7-/7EM FOR 5ERVIGE fiaxlfwn hanger -,�pacinq 4f1. Exception Whcn GONGRDrE PAD duel perimter 80" or /era and does nol require felrfol -caned Iwo jo/d--, are perr•rilled belween hangers REFRIGERANT LINES TO AIR t1ANDLER U.G. IN PVC SLEEVE GONDE 5ING UNIT INS7W -L- tTION OE7 -All- NO SGAI -E ANCHOR W /POWER DRA/EN STUDS OR 3/8 "X1.5 "LG, LAG BOLTS W/ 5t1IELD5 TO WIri15r1iND WIND-'5 OVER 146 MP" OPYEP VENT DETAIL 17VAC piff516N PiffOUIPE: YE-15 NO DU(,- rSMOKE DEMG -Top GVWIrH GOUO!5)VN X F19CVA 1PER(5) 097 x 5MOKia DAM M-15) 4 X FIRElPATEENGL05URE 5 x FIIPE RATED ROOFIFI.009 GMUNG A55EMPI -Y DPAYN DY: Aji ]-,, Jr, x FIRE 5rOPPING JOa No.; X SMOKE wNrFOL x FAITLY POO/I 175 GFM 8"X8 ", 4-W 150 GFM I— -W �, Il 8 "XB,, 4 LJ 5K 9 ROOF. FNN 57OOf 1 �NU o U PROVIDe 10/12/10 GVWIrH GOUO!5)VN Re515rMlr5GKeeN 097 F !'Al rr 2" GOND. 091W. v'JOO� # Z TE TERMNAl2 "LAWNY FROMWALL.6 "A60VD — — — — — — — — — — — FIN 6RNDE RFF. UNF5 3/8" L10.7/8" SijGt � tf5 GFM 8 110 10 "X8 ",3-w WIN6 X00 20" X 20" X 20" IP/M46ULNZ Pox 0 —M 175 GFM 10 ,78'; 3-W 20"X29 X20"- rpIM16(jL vox ININC BOOB 4.0VRYfRVENT tJPTlfR(J GL. #2 40 GFM 6 "X6'; PW p As ' 0 4o GFM 6 "XG ", I-W 4.00,�Dtr covu t�fi��l1 4110 ROO 1GVWIM CORM50N # 2 11 LINEN All" 4 cu 150GFM Apa/fPoor 10 ,7811, l-W- 0^ Powv IIAN C-2,EIPS ANO SUPPOPTS 60 GFM 10 ,78 ", I-W C�I�OOI'1 # 8 AVOlf DOW �- �'� V� , 1, /au v v 1v IN .01 r imloSrrtr PE7VK'NNKrti1 U IZ" FULLY LOWERED 20" X 20" X 20" DOORS 1 / I�L 1 MAW5UW PDX a•xrrRn� AXVr 150 GFM 8110- 101'X8 11,1 4Y SUPPLY DUCT 114ro � Upasoi r PERFORATED GAP FOR VENT, 12" HIGH 3/4" CONDENSATE DRAIN w /3" TRAP UNION AND C.0 TO GREEN AREA GALV. STEEL A/l U. SUPPORT (SELF- STANDING) NO C011PU57-1P1-E MATERIALS WIMIN AtIV. ROOM R/A 7-t1RU —` LOUVER DOOR REFRIGERANT LINE-5 TO OUTSIDE GOND. UNDER SLAB 200 GFM 10"X8 ", 3-W 40GFtl 6"X6", I-W 4A n WIG. 41#0 rrxzo• OAr11 # 1 /CovrV" 40GFM 6X6", I-W 40 M 6"X6 ",1-W 4"OGNDUPror PR0VIDeR00FC.V Wlrl1 COM -60N Re5r5rANrsueeeNC:j U 40 GFM 6 "X6 ", I-W (:D OArr1 # 5 50 GFM ^4z 6 "X6'; I-W �NT�Y I� -7I DRAIN 8" x 16,VEW FLOCK GE /LING 1-1 /2 "X1-1 /2 11X1/8" SUPPORT ANGLE GONNEG -WN TO SUPPLY A/R PLENUM WrrH TWO MEGtIANIGAL FA5TENER5 Ar FRONT OF UNIT A5 PER 51- IAGNA 2.14 PAGE DETAIL AND FOG, M. 603.4.22 FLOAT 5WlTGt1 2 "A/G G.D. UNDERSLAB AIP tYANOI -EP UNIT 157-AL- 1 -A7_I0N DEI -AIL NO SCAL -E PARTITION PROVIDE 4" GLEARANGE ALL AROUND NlU rMArArom 8" X 16 "VFW FLOCK �> L E OA o \ a retePnoNe O 1 O � 1 �v0 O a 0 a 0 O V1 FEV /5/ON5 1 10/12/10 2 5 4 5 DPAYN DY: Aji ]-,, Jr, DArn 04122110 JOa No.; 1010 r °iC, l of f