11-1226-001General Notes:
1. Ali plant material shall be Florida No. 1 or better as given in the current Grades and Standards
for Nursery Plants, :2`d Edition, February 1998, Florida Department of Agriculture and
Consumer Services, Division of Plant Industry.
2. All plant materials shall be subject to inspection and approval by the Landscape Architect at
place of growth and upon delivery for conformity to specification.
3. All plants shall be true to species and variety and shall conform to measurements specified.
All substitutions shall be submitted to the City and Landscape Architect for final approval.
4. All plants shall be exceptionally heavy, symmetrical, tight knit and so trained in appearance as
to be superior to form, branching and symmetry,
5. Contractor shall notify S.U.N.S.H.I.N.E. (1-800-432-4770) for locations of existing utility lines
48 hours prior to beginning work. Contractor shall verify location of all utility lines and
easements prior to commencing any work. Excavation in the vicinity of underground utilities
shall be undertaken with care and by hand, if necessary. The Contractor bears full
responsibility for this work and disruption or damage to utilities shall be repaired immediately
at no expense to Owner.
6. Grade B+, shredded sterilized Melaleuca or Eucalyptus mulch shall be used in all mass
planting beds and for individual tree pits. All trees shall have a mulch ring with a depth of 3"
and a diameter of X- 4' around their base. All mulch shall be kept 4' from base of all plant
material. Mulch beds shall be a minimum of 12' wider than plants measured from outside
edge of foliage.
7., Sod shall be St. Augustine 'Floratam' solid and free of weeds, insects, fungus and disease,
laid with alternating and abutting joints.
8. All trees and shrubs shall be backfilled with a suitable planting soil consisting of 50 percent
sand and 50 percent approved compost All plant materials shall be planted with a minimum
of 6 to 18 inches of this planting soil around the root ball. Refer to planting details. Planting
soil to be backfilled into plant pits by washing in. Planting beds shall be free from road, peen,
egg or colored rock, building materials, debris, weeds, noxious pests and disease.
9. All trees shall be warranted by the Contractor and will be healthy and in flourishing conditim of
active growth one year from date of final acceptance.
10. All shrubs, gmundcovers, vines and sod shall be fully warranted for 90 days under same
condition as above.
11. All synthetic burlap, synthetic string or cords or wire baskets shall be removed before any
trees are planted. All synthetic tape shall be removed from trunks, branches, etc before
inspection. The top 1/3 of any natural burlap shall be removed or tucked into the planting hole
before trees are backfilled. Planting soil to be backfilled into pits by washing in.
12. All trees, palms and other plants shall be planted with the top of their rootballs no deeper than
the final grade surrounding the planting area.
13. In areas where paved surfaces abut sod or mulch, the final level of both surfaces should be
even.
14. Ali planting shall be installed with fertilizer at time of planting. Fertilizer shall be a complete
I
ete
fertilizer with a N-P-K ratio of 10-3-15.
16. All planting shall be installed in a sound, workmanlike manner and according to good plantirg
procedures. Installation shall include watering, weeding, fertilizing, mulching, selective
pruning and removal of refuse and debris on a regular basis so as to present a neat and wen
kept appearance at all times.
16. All landscape and sod areas shall have an automatic irrigation system installed. Coverage
should be 100% with 50% minimum overlap using rust free water to all landscape and sod
areas. Spray upon public sidewalks, streets and adjacent properties should be minimized.
Sodded areas and shrub/ groundcover beds should be on separate irrigation zones for a more
efficient system. Irrigation system shall be installed with a rainswitch device.
17. All landscape and irrigation shall be installed in compliance with all local codes.
18. The plan shall take precedence over the plant list should there be any discrepancy between
the two. -
•
overhead utill1h Unes
sod
irrigate to edge of road.
L COWAL�MR GRZ)UN SwFalea • Loo-lem
ARE
pLANTED N SEPC7, EXCAVATE W4TIRE
ROOTS AT EDGE OF ROMALL �
SET F'4LM$ Kim a TF4M TO ap-ADU
2. BALL AK:i SUM_� 6WW04 - = 4
MMIRE_
KSFORTA'1`10�4
Tte rRo\p6 VMW3 TRA
4, pErT1• OF f*LA4TNa M-6PALL NOT
To FIWTECT &RL%M T"
OF Tt-M BALL.
po NOT TK" rt3
FOP, 13 4 5 PAL .I$ vir AND REMOVE
GRAM
EtUjaAf, FROM Top" R90T5ALL
Note:
(4) 7'x4'xl6' P.T.
5ASN- FORM _114L��ER
SAEAL PALM rRotM
ENTIRE M_4tMWS 5-M.
LW 3'CON'TNOL* F:JM
Tr;A T
C'o NOT PUNMRS
C112
4 LAYERS Or eURL,44* WITH 2 GAL Y.
$TM a4tV-S tLW�IFW ARO�tD I�ATTENS
TABLEM
'PLANTR,*
BACKFILL MATURE.- WATER
TAMF To REMOVE AfR FOCKETS
(4) 2"x4' RT. W=
COMPACTED BACK;qLL MIXTURE
>
431011r iwAZ G-PA6e
BRACES
SHRUB PLAMINC DETAIL
NTS
DtFFTW LAYER Cr I'MON
Mt`�ORARY WATER
s
2x4X24d ' F'X, WOOD 'S_rAKE`*�
V 4'PM Caxml�ms -M
5ELOW GRAPE
FU,6 A GRADE
ROM�JJ.
"45i =TIS
t LL MIXTURE --WATER
AIR FOTS-
iu
eACKFILLMDMRS
0C:trACTW $t5 -GRADE
PALM PLANUNG DE7AIL
•
overhead utill1h Unes
sod
irrigate to edge of road.
Irrigation Legend
Q1" Irrigation meter.
A 1" PVB back flow preventor.
T/C Rainbird ESP controller.
R/S Rain sensor.
0 Rainbird electric control valve.
0 Rainbird 4" pop up mist heads with nozzles as shown.
PVC class 160 pipe. Schedule 40 PVC pipe for supply
PVC schedule 40 sleeves
t'kalt� 10 P/14
Install irrigation system per appendix F in Florida Building Code.
V
LOCAINON MAP
P2
L COWAL�MR GRZ)UN SwFalea • Loo-lem
ARE
pLANTED N SEPC7, EXCAVATE W4TIRE
ROOTS AT EDGE OF ROMALL �
ow 4 FLL W/ m-4NTNG SAC34FILL
2. BALL AK:i SUM_� 6WW04 - = 4
MMIRE_
fr=moya %RLAP FROM TOP 113 OF
4, pErT1• OF f*LA4TNa M-6PALL NOT
BB LEGO T"fl-ln TM6 THE PEFTR
OF Tt-M BALL.
ROOTSALL to mvsw UIN FINISH
GRAM
TEMPORARY WAT.t-=-
31 LAYER OF MJLC44
5ASN- FORM _114L��ER
ENTIRE M_4tMWS 5-M.
LW 3'CON'TNOL* F:JM
C112
TABLEM
'PLANTR,*
BACKFILL MATURE.- WATER
TAMF To REMOVE AfR FOCKETS
COMPACTED BACK;qLL MIXTURE
comi-AcTim W5-*XADfE
SHRUB PLAMINC DETAIL
NTS
Irrigation Legend
Q1" Irrigation meter.
A 1" PVB back flow preventor.
T/C Rainbird ESP controller.
R/S Rain sensor.
0 Rainbird electric control valve.
0 Rainbird 4" pop up mist heads with nozzles as shown.
PVC class 160 pipe. Schedule 40 PVC pipe for supply
PVC schedule 40 sleeves
t'kalt� 10 P/14
Install irrigation system per appendix F in Florida Building Code.
V
LOCAINON MAP
P2
I- REVISIONS I
SEAL
(A
-5, QV"
L-,4 F
A*
I- REVISIONS I
SEAL
(A
-5, QV"
L-,4 F
SHEET TITLE
Landscape Plan
X
C112
SHEET TITLE
Landscape Plan
X