13-491-014s c u MAX ABOVE TOP OF GRADE F=0t ]NnAT10N /C.R0t ]N1) FI 00R PI AN 5CAL5: 1/4' a 1'—O' NOTE: 1— CONTRACTOR SHALL COORDINATE ALL DIMENSIONS ON THESE STRUCTURAL DRAWINGS WITH THE EXISTING STRUCTURE AND THE ARCHITECTURAL DRAWINGS PRIOR TO PROCEEDING WITH THE WORK. 2— CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. FOUNDATION NOTES: 1. TERMITE TREATMENT OF SOILS UNDER SLAB ON GRADE SHALL BE PERFORMED BEFORE POURING SLAB. GENERAL CONTRACTOR SUBMIT SUBMIT CERTIFICATE OF COMPLIANCE WITH THE F.B.C., "RESIDENTIAL ", CHAPTER 3 BUILDING PLANNING, SECTION R320 " PROTECTION AGAINST TERMITES" OR "BUILDING CHAPTER J8 SOILS & FOUNDATION, SECTION 1816 "TERMITE PROTECTION . 2. CONTRACTOR TO COORDINATE GROUT FILLED CELL LOCATIONS LOCATIONS FOR GIRDERS AND CHANGE OF BEAM HEIGHTS. 3. ALL ANCHORS SHALL BE EMBEDDED INTO POURED CONCRETE OR GROUT FILLED CELL. 4. GC TO VERIFY ALL DOORS AND WINDOW OPENINGS DIMENSIONS PRIOR TO THE SLAB POURING W/ MANUF. AND METRO DADE PRODUCT CONTROL REQUIREMENTS. VOTES FOR ENHANCEMENTS TO EXISTING STRUCTURE: 1. IMPACT RESISTANCE DEVICES HAVING A VALID NOA SHALL BE INSTALLED AT OPENINGS TO PROVIDE PROTECTION AGAINST STORMS. SWIMMING POOL DESIGN AND ENGINEERING ARE NOT WITHIN THE SCOPE OF THESE ENGINEERING DRAWINGS. SOIL STATEMENT: A MINIMUM OF ALLOWABLE SOIL BEARING CAPACITY OF 2500 PSF WAS USED FOR THIS FOUNDATION DESIGN. SEE STRUCTURAL NOTE No. 11. /S -5. ALL FOOTINGS SHALL BE EMBEDDED AT LEAST 8" INTO THE UNDISTURBED LIMEROCK. THE ELEVATION / DEPTH OF THE BOTTOM OF THE FOOTING VARIES DEPENDING ON THE LOCATION OF THE UNDISTURBED LIMEROCK LAYER BUT IN NO CASE THE TOP OF THE FOOTING WILL BE LESS THAN 1' -4" BELOW GRADE. THE PRESENCE OF LIMEROCK IN THE SITE SHALL BE VERIFIED BEFORE PROCEEDING WITH THE CONSTRUCTION OF THE FOOTINGS /PROJECT. IT IS RECOMENDED TO PERFORM A SOIL INVES11GA11ON BY A SOIL ENGINEER REGISTERED THE STATE OF FLORIDA TO VERIFY THE SITE EXISTING SOIL CONDITIONS BEFORE PROCEDING WITH CONSTRUCTION/ EXCAVATION. IGNACIO J. CALVO STRUCTURAL ENGINEER FLORIDA LICENSE NO. 56755 1800 S.W. 27th. Ave. #401 Miami, Florida 33145 Ph: (305) 648 -9008 Fax: (305) 648 -9128 E —MAIL: ijcpe@bellsouth.net Lai 7601 SW 60 AVE MIAMI, FL 33133 KEYPLAN N.T.S. REVISIONS ARCHITECTURE PRELIMINARY REVIEW NORTH GIORGIO BALLI ' °lPffi ARCHITECTURE INTERIORS CONSTRUCTION C SC ' 1t,1G t JOB NUMBER: 2012 - GRAF CHECKED BY: M. ENRIQUEZ °' `' pp rSSl1E DATE: la OCT. 25, 2012 - SCALE: AS NOTED SHEET TITLE FIRST FLOOR SHEET NUMBER S -1 COPYRIGHT GIORGIO BALLI, PA. 8301 SW 53 AVE MIAMI, FL 33143 - 305.669.5160