Loading...
11-1243-020EXIST ACOUST. CEILING 4 INSULATION TO REMAIN �I REPAIR AGOUST. CLG TILES AND 5PLINE5 A5 REQUIRED TO MATCH EXISTING.. NEW 1/2" DR1'UJALL GOOI;�IDOR 51DE, DRYWALL 5GREW5 "� 8" O.G. NEUJ 3 -518" 22 GA, METAL STUDS e 1G " C-C. NEW 1/2" LEAD DINED DRYWALL TO CEILING ON X =RAY ROOM SIDE. USE 1 -=1/2'' DRYWALL. SCREWS W/ LEAD D15K5 @ 5" O.G. INTO METAL FRAMING, FLOOR 4 SASE TO MATCH EXIST AGOUST. GEILING OL a'-011 AFF CONT. 2X8 WE) 5UPPORT AL CONTINUOUS X -RAY EQUIPMENT 5UPPORT BLOGKING ATTACHED TO METALL 5TUD5 U51NG 3- 110 UJOOD SCREWS EA END. IN5TALLED ON EAST AND SOUTH WALLS, AT EQUIPMENT INSTALLATION PROVIDE LEAD D15<5 FOR FASTENERS PENETRATING THROUGH LEAD LINER, GONT, 2x8 WD SUPPORT AL 10" AFF t' 2 I SECTION DETAIL WALL SYMBOL LEGEND EXISTING a" CMU PERIMETER WALL W/ EXTERIOR STUCCO FINISH 4 INTERIOR DRYWALL OVER FURRING STRIPS. DENOTES EXIS"T"ING 1 HR FIRE RATED PARTITION: No. 25 GAUGE CHANNEL 51 -IAPE 3-5 /a" STUDS 1 (o" O.C. WITH ONE FULL " TYPE "X11 5/8" GTF,SUM WALLBOARD EACH SIDE SPANNING FROM SLAM ON GRADE TO 2ND FLOOR DECK. EXISTING INTERIOR DRYWALL PARTITION WITH 1/2" GYPSUM WALLBOARD EACH SIDE TO REMAIN. 7 NEW INTERIOR DRYWALL PARTITION: No. 25 GAUGE CHANNEL 5HAPE 3 =5/0" STUDS �@ 16" O.C. WITH 1/2" GYPSUM WALL50ARD EACH 51DE ATTACHED WITH I" LONG No. & DRYWALL SCREWS TO EACH 51DE, 5CREW5 ARE a" O.G. ALONG THE PFRIMETER AND 12" O.C. ALONG THE INTERMEDIATE STUD. SEE DET G (1) /D =1 INTERIOR DRYWALL PARTITION W/ ADDITIONAL NEW LEAD LINED WALL BOARD FLOOR TO CEILING FOR X -RAY ROOM. SEE DET /o(2) /D -I. DDOOR NUMBER. SEE DOOR SCHEDULE NOTES 1. INSTALL WEATHERSTRIPPING 4 1112" MAX. W.P. THRESHOLD @ ALL EXISTING EXTERIOR SWING DOOR LOCATIONS. a) 04' -10" 25' -2° 00 SUITE- B SUITE- A m N m 00 . CV EXIST. 5' CONCRETE EX15T. 5' CONCRETE I ( I WALKWAY W/ CESiT IAMIC TILE +4152 p WALKWAY W/ CERMAMIC TILE ILL un FINISH. REPLACE: EXIST. TILE � 51!08 pe f � W FINISH. REPLACE EXIST. TILE � „ O W/ SLIP RESIST. FINISH TILE. \ / W/ SLIP RESIST. FINISH TILE. — m a (,,,) \ I/2' MAX. THRESHOLD \ / U 7 ui ui W EX15T. EXAM EXIST. EXAM ROOM ROOM EX15T. WAITING = LLJ m LOUNGE CV EX15T. OFFICE V) m /' �' EX15T. OFFICE _ `n m OE Z y C)0 N �:J Q Q r- / DOCTOR'S OFFICE NEW OFFICE Q NEW D CLOSET O4 L L 4' -9" NEW PRIVATE4 ' �, O REST ROOM IT 074 / NEW OFFICE 1/2" MAX THRESHOLD �v m \ 0 NEW OFFICE NEW STOREFRONT` D POOR AND WINpOtU 2 SEE 4/D -1 FOR \ EXIST. 5' CONCRETE WIND PRESSURES \ WALKWAY W/ CERMAMIC TILE FINISH. REPLACE EXIST. TILE W/ SLIP RESIST. FINISH TILE. D EX15T. CORRIDOR \ O Q \ rl EX15T. REST \ DROOM O , 0 EX15T. EXAM 8001'1 D � 0 EXIST. REST / ROOM , o EX15T. CORRIDOR \ EX15T. MEDS \ STORAG� — EX15T. 1 RECEPTION I 5TATION5 11 II II E. II 5 II II 1L - -- \ 0 \� EX15T. MO FILE 5TORAGE 51NK CLO.1 8" =1 10° N 11 I lU u L_ NEW X -RAY M n) oi�l \ O ELECT. ELECT. PANEL PANEL \\ 0 D a \ \ EXIST. FILES NEW EXAM STORAGE ROOM 4' NEW EXAM ROOM EX15T. OFFICE L— D EXIST D 5T9RAGE LY // — EMPLOYEE EX15T. ELECTRICAL \ I/2' Max. THRESHOLD LOUNGE EQUIPMENT ROOM 0 0 KEW OOR AND WINE) W l J \ D I\ I\ SEE 5/1:)-1 FOR \\ WIND PRESSURES \ \ DOOR SCHEDULE LOCATION A E w 4 DOOR SIZE MATERIAL FINISH FRAME DETAIL HARD WARE REMARKS WIDTH HGHT THICK. THR. JAMB HEAD OFFICE ENTRY STOREFRONT 1 A 61-0" -1' -0" 1 -3/4" ALUM- CAL ES PAINT ALUM 1 /D -1 1 /D -1 VD -1 PAS /DB IMPACT GLASS DOOR U/SELF CLOSER ## EXTERIOR STOREFRONT la B 3' =0" 7' -0" 1 -3/4" ALUM- GL ES PAINT ALUM I /D -I 1 /D -1 I /D -1 PA5/D5 IMPACT GLASS DOOR U /SELF CLOSER '# OFFICE EXTERIOR 2 B 3' -0" T' -0" 1 -3/4" ALUM - GL ES PAINT ALUM 1 /D -I 1 /D =1 1 /D -1 PAS IMPACT GLASS DOOR U /SELF CLOSER ## Ei FLOYEE OFFICES/ LOUNGE 3 C 3' -0" ro' -8" 1 -3/4" I.UD HG P, LAM LUOOD - - PRI RE5TROOM 4 C 3' -0 8" 1 -3/4" WD, HC B IRCH WOOD MAR = PRI SELF CLOSER'* X -RAY ROOM 5 D 3' -0" 'o' -P>" 1 -3/4" SC -LEAD P. LAM HOLLOW MTL - - - PAS /D5 LEAD LINED, LEAD GLASS, SELF CLOSER ## BI -FOLD - 2' -0 8" 1 -3/0" I.UD. SC BIRCH - - - - BI -FOLD T - 3' -0" o' -8" 1 -3 /a" LUD, SC BIRCH - - - = FULL LOUVERED DOOR. 180 DEG FOLD OPEN, UNDCUT DR. RESTROOM 8 C 4' -0" 0' -8" 1 -3/4" WD. HC BIRCH WOOD MAR EXISTING TO REMAIN E - 3' -0" 8' -0" 1 -3/4" HARDWARE LEGEND PA5 1`455AGE LATCH FRI PRIVACY LOCK DB STANDARD DEAD BOLT DBE) DEAD BOLT DOUBLE CYLINDER BL BUZZ- IN LATCH KL KEY LOCK CKL CARD KEY LOCK x0 - 2007 FBC COMPLIANT ADJUSTABLE DOOR HINGE CLOSER NOTE: ANY UN -RATED DOOR FIN1514ES CAN BE INTERGHANGED BETLUEEN BIRCH AND PLASTIC LAMINATE AT OLUNER'S OPTION. FLOOR PLAN SCALE: 1/4 -1-0 CONTINUOUS X -RAY SUITE- A EQUIPMENT SUPPORT BLOCKING INSTALLED ON EX15T. ADJACENT EAST AND SOUTH WALLS. Bu51NE55 OCCUPANCY SEE DETAIL 2 THIS SHEET. DOCTORS OFFICE N.I.C. X -RAY IMAGE READER AND CONTROL CONSOLE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE OWNER AND UNIT MANUFACTURER AS REQUESTED 137 MIAMI -DADE COUNTY DERM: THE UNIT TO BE USED IS FUJIFILM MODEL NUMBER FCR XC -2, THE X -RAY IMAGE WILL BE RECORDED ON THE ABOVE CAPTIONED DIGITAL RADIOGRAPHY 7STE M UNTILIZING PHOSPHOR IMAGING PLATES AS AN X -RAY DETECTION DEVICE. IMAGES WILL BE PRESERVED IN DIGITAL FORMAT ONLY. NO LASER PRINTING OR WET PROCESSED FILM OF ANY KIND WILL 13E USED. 0 EXIST, STORAGE , / O - \ \ EXIST. 5' CONCRETE WALKWAY W/ CERMAMIC TILE FINISH. REPLACE EXIST. TILE W/ NON -SLIP FINISH TILE. � 0�1I1. ;D v ,. kP svil0l" wvRollell GENERAL NOTES 1. ALL W01RK SHALL 51- PERFORMED IN ACCORDANCE WITH ALL CODES, RULES, 8. ALL CONVENTIONAL DRYWALL CONSTRUCTION, FURRING, 4 REGULATIONS AND RESTRICTIONS HAVING JURISDICTION ON THIS PROJECT. SHEATHING SHALL 5E AS DETAILED IN THESE CONSTRUCTION AS PER LATEST EDITION OF FLORIDA BUILDING CODE. DOCUMENTS. DRYWALL JOINTS SMALL BE TAPE D /SPACKLED 2. WORK SEAL L INCLUDE ALL ITEMS (BUILDING AND SITE) INDICATED ON THESE LEVEL. EXTERIOR CORNERS SHALL RECEIVE METAL DRAWINGS UNLESS OTHERWISE NOTED, CORNER REINFORCING BEAD AND BE SPACKLED IN CONVENTIONAL MANNER, FULL HEIGHT GYPSUM 1 CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE BOARD SHEETS SHALL BE USED THROUGHOUT FOR ARCHITECT SMALL BE NOTIFIED OF ANY DEVIATION FROM THE PLANS PRIOR THE FULL HEIGHT CONSTRUCTION. TO CONSTRUCTION. 4. DRAWINGS SHALL NOT BE SCALED-1 WRITTEN DIMENSIONS SHALL TAKE c3. NO STRUCTURAL MEMBER SHALL BE NOTCHED, CUT, PRECEDENCE OVER SCALED DIMENSIONS. ALTERI=D OR MOVED IN ANY WAY WITHOUT PREVIOUS AUTHORIZATION FROM THE ARCHITECT, 5, OWNER/ CLIENT SHALL MAINTAIN TEMPORARY ELECTRICAL, WATER AND SANITARY FACILITIES FOR THE DURATION OF CONSTRUCTION. 10. ALL WORKMANSHIP SHALL BE NEAT, CLEAN, TRUE AND CORRECT. ro CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS FROM THE JOB 11. OMISSIONS FROM THE DRAWINGS OR SPECS, OR THE M15DE5CRIPTION OF SITE ON A REGULAR BASIS AND LEAVE THE BUILDING BROOM CLEAN. DETAILS OF WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT �. THE CONTRACTOR SHALL (RESTORE ALL EXISTINCz FINISHES TO THEIR THE INTENT OF THE DRAWINGS 8 SPECS., OR WHICH ARE CUSTOMARILY ORIGINAL CONDONSHALL PRIOR E THE COMPLETION FINI OF THE WORK. PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR MISDESCRIBI =D DE-TAILS OF WORK, BUT THEY SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. Z A O = GD M Q I w d- m > O D ,- M d- am Z � M Q J LU Q _ LL j 2: � Lu < a H w N Q 00 LL .1 L L O Q 0 = �N z� D Q�o� � U_� `n O ❑ Imo, V) W <1 N 4 i z w 0 C-) ry w <1 O U) Z 0 (0 bi s V) wz OFF _ =Z V ZZ � UFO ZOO O oz °ma zoo w0c oW�W Nawm &�w oX, waa- N� a�W°� °w� ��� >= a o 0 a OW 00 UJ D �W�W� w¢4 Caj�jj ?�� -{� fa�¢ ZaQQNq Z W F- V�Ow o� zoo o Z�z'Wo zM a o��i -wW V �+2 im0 Z�ZO oz w >- z �o a 1. am .-z" zLLf-vi ¢ M O ~ K Z' z o -Zz 0z �° cZja=�� Oax �`w wm,Z° W. Lbw NwWWU ❑F--> w °'°m zQOm zmO aao�� �xv °trTi c A = N N W I T V) U i Q Q r- a o U) 0