Loading...
13-842R-003NEW ROOF PLAN SC: 3/8" _ l' —o" DRAWN BY: DATE: REV. No. REVISION DESCRIPTION DATE: v J -4--G 5 S 31 � �� 7� SINGLE FAMILY HOME THE FERNANDO RONDINONI RESIDENCE 7530 S. W 63rd AVE. SOUTH — MIAMI — FLORIDA 33143 NORTH M N'll IRA 12 4 F_ 0 2" X 12" WOOD JOIST NEW 8" BOND BEAM 1 #5 REBAR NEW MASONRY WALL EXISTING EXT. WALL NEW 4" GROUND ---' EXISTING FOOTING i HST3 (6)16 NAILS SCALE 1/2 Pp=l$_0ff #5 REBAR .. —1-: PLYWOOD ROOF SHEATHING A. PLYWOOD ROOF SHEATHING SHALL BE 19/32" EXTERIOR GRADE. SHEATHING, WITH 32/16 B. LAY PANELS CONTINUOUS OVER TWO OR MORE SPANS AND WITH FACE GRAIN APA SPAN RATING PERPENDICULAR TO PRIMARY FRAMING MEMBERS, AND JOINS SHALL OCCUR AT CENTER OF PRIMARY FRAMING MEMBER WITH BOTH PANELS FASTENED TO IT. END JOINS SHALL BE STAGGERED. C. ALL ROOF SHEATHING SHALL BE ATTACHED TO A MINIMUM 2" THICK NOMINAL MEMBER WITH ITS DEPTH EQUAL TO OR ONE SIZE GREATER THAN THE INTERSECTING TOP CHARD THIS SHALL BE ACHIEVED W/ CONTINUOUS STRUCTURAL FASCIA WITH NAIL 3" O.0 D. FASTEN PLYWOOD ROOF SHEATHING PANELS TO ALL SUPPORTING MEMBERS USING 8D RING -SHANK NAILS. NAIL SPACING SHALL BE 3" O.0 AT EXTERIOR MEMBERS WITHIN 3" FROM HOUSE PERIMETER AND 6" O.C. NAIL SPACING SHALL BE 3" OC AT EXTERIOR MEMBERS WITHIN 3" O.0 AT EXTERIOR MEMBERS WITHIN 3" FROM HOUSE PERIMETER do 6" O.C. E. EXTERIOR PORCH CEILING 7/8" STUCCO ON HIGH RIB LATH W/2 1/4" EMBED NAILING. F. PLYWOOD WALL SHEATHING SHALL BE 19/32" EXTERIOR GRADE , NAILING W/ 10D 4" O.0 ® EXTERIOR MEMBER WITHIN 3" FROM HOUSE PERIMETER)AND 6" O.0 ELSE WHERE. GYPSUM BOARD PARTITIONS • NON -RATED PARTITIONS SHALL HAVE 1/2" TH GYP. BD. ON EACH SIDE OF 3 5/8" TH. METAL STUDS AT 16" ON CENTER AND 2X4 WOOD STUDS AT 24" ON CENTER. • FIRE RATED NON- BEARING PARTITION SHALL HAVE 5 /8"TH TYPE "X" GYP. BD. ON EACH SIDE OF 3 5/8" PIAN) METAL STUDS AT 16" ON CENTER WITH R -11 FIBERGLASS INSULATION BETWEEN ELSE WHERE. • BEARING PARTITION SHALL HAVE 5/8" TH. TYPE "X" GYP BD. EACH SIDE OF 2X4 WOOD STUDS AT 16" ON CENTER. STORAGE AREA SHALL HAVE 2 LAYERS OF 5/8-TH. TYPE "X" GYP BD. SECURED TO THE WALLS OF THE STORAGE AREA. • CEILING OF STORAGE AREA SHALL HAVE 2 LAYERS OF 5/8" TYPE "X" GYP.BD GENERAL ROOF NOTES 1. HOWEVER, THE SUPPORTING, SUPERSTRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THAT THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS MFG LAYOUT. THIS FRAMING SCHEME (DIRECTION OF TRUSSES MAJOR G.T BEARING POINTS. ETC.) CAN BE MODIFIED ONLY AFTER OBTAINING PERMISSION FROM THE PRIME PROFESSIONAL OF RECORD WHO MUST REVIEW PROPOSED CHANGES AND MAKE STRUCTURAL REVISION ACCORDINGLY. FINAL SIGNED AND SEALED TRUSS DRAWINGS MUST BE SUBMITTED TO THIS OFFICE FOR REVIEW PRIOR TO PERMIT SUBMITTAL AS PER GENERAL NOTES. 2. REFER TO DESIGNERS FLOOR /FOUNDATION PLAN DRAWING FOR ALL ROOM VAULTS, TIE BEAM HEIGHTS, SIZE AND REINFORCING. 3. CONTRACTOR IS RESPONSIBLE FOR ALL STRUCTURAL COORDINATION AND SHALL NOTIFY DESIGNER OF ANY DISCREPANCIES PRIOR TO POURING OF FLOOR SLAB IN WRITING. 4. ALL CONNECTOR STRAPS SHALL BE GALVANIZED SHEET STEEL ASTM A446 -75 GRADE A (FY =33,000 P.S.I) 5. ALL STEEL SEAT DETAILS SUPPORTING GIRDER TRUSSES SHALL BE COORDINATE WITH THE TRUSS MANUFACTURER FOR SIZE AND BOLT SPACING REQUIREMENTS (SEE PLAN) 6. ALL FLAT ROOF AREAS SHOULD HAVE A MINIMUM SLOPE OF 1/4" PER FOOT. 7. GABLE END TRUSSES: NAIL 8D RING -SHANK 6" O.C. 8. GABLE END TRUSSES: USE RING SHANKS OR 1 OD NAILS FIRST 5 FEET.BLOCKING m ` 48" O.C. MAX IN FIRST 2 FRAMING SPACES EACH END. 9. GIRDER TRUSSES SIZED BY MANUFACTURER. -�-} 1b. ARE TO BE SECURED TO CONCRETE BEARING SURFACES WITH A SIMPSON HHETA -20 OR WOOD BEARING SURFACES WITH A SIMPSON MID. 11. ON ANY TRUSSES 40' OR GREATER, CONTRACTOR SHALL NOTIFY DESIGNER OR ENGINEER ONE WEEK IN ADVANCE TO ARRANGE FOR FIELD SUPERVISION. 12. ROOF MUST WITH STAND 170 MPH WIND LOADS CONTRACTOR SHALL PROVIDE MANUFACTURES SPECS ON ROOFING. 13. PROVIDE 22 "X54" ACCESS PANELS W/ FOLD DOWN LADDER. 14. ROOF SPECS AND PRODUCT APPROVAL TO MATCH EXISTING ROOF MATERIAL (UNLESS ENTIRE ROOF TO BE REPLACED) 15. ALL STUDDED POST MUST BE CRIPPLED AT ROOF GIRDER BEARINGS AND WOOD BMS.GLUE AND NAIL PLIES AT 12" O.0 TYP. WALLS SHEATHING MUST BE NAILED TO EA. PLY AT BOTH SIDES. DRAWING SCALE • 3/8" =1' -0„ SHEET TILE • NEW ROOF PLAN SHEET NUMBER A -6