Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-222-006
I11111111117A WP 185cd H107 EOL CIRCUIT #2 PS 102 115 Wp `-11 ti P H WP M 11Ocd H104 OPEN H WALKWAY 114 D 113 1F 01 WP d H103 OPEN WALKWAY % KEG' PLAN N SCALE: N.T.S. FIRE AL_A�:14I FLAN — FiR&T FLOOR \ N SCALE: 1/S' =1' —0' \ \ STAIR # 1 or 2 Hour Fire Rated 2 Hour Fire Rated Through �e•• ir, Through Penetration Firestop for U b U�yse ir, Penetration Firestop for Multiple Metal Pipe through Sinale Metal Pipe through Gypsum walls using a Concrete floors or walls TREMsto WBM. etd� p using FYRE- SHIELD. gletd` WL1147 F- rating = 1 and 2 Hr. CAJ -1304 F- rating = 2 Hr. T- rating = 0 and 1/2 Hr. T- rating = 0 Hr. 1 L^ �� 2 I _ t 1 l>j _ _ -- 2 (D Floor or Wall assembly = 4 "thick concrete, Max. area of opening is 288 sq. in. Z Q - Copper Pipe: 4" dia. (or smaller) regular (or heavier) copper. M -Steel Pipe: 8" dia. (or smaller) Sch.40 (or heavier) steel. - Conduit: 4" dia. (or smaller) EMT or 6" dia. (or smaller) steel conduit. U ' - Copper Tubing: 4" dia.(or smaller) Type L(or heavier) copper. 10 1 or 2 - hour fire rated gypsum wallboard /stud assembl -Iron Pipe: 8" dia.(or smaller) cast or ductile iron. ® A) Steel Pipe - 6" diam.(or smaller) Sch. 40 (or heavier steel -Max. number of pipes with opening is three (3). B) Conduit - 4" diam.(or smaller) EMT or rigid steel A) Forming Material - (Not shown) Nom. thick ® TREMstopWBM - fill Max. 3/4" annulus at a thickness is urethane backer rod friction fitted e fitted of 1'+ " (2 Hr. F- rating) or 3/4" (1 Hr. F- rating). " into opening. J B) Nom. :f FYRE- SHIELD thickness installed within opening. LL NOTE: For wall apply FYRE- SHIELD to both surfaces of wall. 2 Hour Fire Rated Through 1 or 2 Hour Fire Rated Through G`ossi�iea Penetration Firestop for Singleu`ogsifi Plastic Pipe through @o Penetration Firestop for Plastic Pipe through U Walls Concrete Floors or Walls Wt L Gypsum using sing BlazeMaster Caulk & Wal �steR` FYRE- AN SLEEVE CAJ 2221 F- Rating = 2 Hr. WL2151 F- rating = 2 Hr. T- Rating = 1 -1/2 Hr. T- rating = 1 Hr. 4 ............... .. ............... a Q• - ° e. a - °.Z_- - -- --° -- 1Q Pre —Rated Concrete Floors or Block Walls = Yin. 4-1/2" thickness Q Plastic Pipe — A) Nom. 2" diam. (or smaller) Sch. 40 PVC pipe. B) Nom. 2" diam. (or smaller) CPVC pipe The annular space range shall be min min 1/4" to max 3/8" © Pre —rated gypsum wallboard /stud assembly. NOTE. For use in closed (process or supply) piping systems. 0 Forming Material — Foam backer rod firmly packed into the opening as a permanent form. O Plastic Pipe - 3" dia. or 2" dia. Sch.40 PVC for use t�}4 BlozeMaster Caulk do walk — min 112" thickness of sealant applied within opening, flush in closed or vented piping systems. � FYRE -CAN SLEEVE intumescent device' : top surface of floor or both surfaces of wall assembly Nom. Pipe Diam. of Annular Diam. in. Device Size Opening (in.) Space in. 2 TS2 3-1/2 1/4 to 7/8 3 TS3 4-3/4 1/2 to 3/4 ® TREMstop WBM - Min. 1/4" thick sealant applied at sleeve /pipe and sleeve /wall interfaces. �Mffmo The products used in the above assembly have The above described assembly and products have been tested and are been tested in accordance with the following: based on both past and anticipated 3735 Green Rd. • ASTM E814 (UL1479" Standard Test Method performance criteria. Tremco shall Beachwood, OH, 44122 for Through Penetration Firestopping. ortcborei liable for any hint torn direct sequential, resulting from use • ASTM E119 (UL 263) Standard for Fire Tests of this material or design. Tremco shall only be responsible for replacing Drawing not to scale of Building Construction and Materials. material found to be defective. M100 A [ F1WP 00 y H100 110WPd STOR SD D100 KNOX BOX 'BY OTHERS Dcd WP DETAiL"S SCALE: N.T.S. - r � fix a w zh L^ �� 1 Z U'> M U ' w i= � `- c'? U_ 0 W U � p ` J — LL L6 LU Lu z ° M < LO 00 C%j Q __j LLJ REVISIONS t + -a `,• cal V Zr' Z L7" �. V1 A* • .• �-�% CO) o rcrh�F sit ` LLI O Uw�q W a_s ci Z 3 LLj 3zw 4 * U' E, 0 %�4 Z 6z� M � N � IY w Q W to IZ [" XJ �i„ W 0 Mj Im PROJECT NO.: DRAWING NO.: SCALE: 118" =i' -0" DATE: 01/18/2010 DRAWN BY: C.E.C. ISSUED: FOR PERMIT SHEET NO.: FA -1 OF 04 a L, L»