13-1396-070(TYPICAL # 2,3 do 4) 120 /208V PANEL "A" 150A M.L.O. 3PH,4W OFFICE #1 FLUSH MTD BRANCH CIRCUITS LOCATION WIRE A: ^vf7 CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A TEMP LTG #12 -1/2 "C 900 1P--20 1 2 2P 5500 2 #6 -3/4 "C AMU #2.1 SPARE U-j 600 900 3 4 3 4 60 5500 TEMP. LTG, 1 (10 KW) LL 600 \ J Q 900 G � + 5 6 2P (2200) 2 #10 -3/4 "C C. U. #2.1 600 � �y V J 7 300 1P -20 600 7 8 1 35 (2200) N (3T) Z Z 9 10 900 600 9 10 ELEV. CAR CORR, REC. (2nol.FL) SPACE 600 11 900 W 11 12 1st. FL. RESTROOM 1st, FL. CORR. < a SPACE - 13 13 14 Q 600 2nd. FL. RESTROOM TELEPHONE - - -- 600 L 15 16 16 1 600 __ _ - - - - -- — 17 18 17 15 2P 2750 2 #10 -1/2 "C AHU C PARKING LTG. 19 20 19 20 1 30 2750 �_ -- PARKING LTG. - 21 22 21 22 2P (1500) 2 #10 -1/2 "C C. U, C OUTSIDE LTG. 23 24 23 24 30 (1500) 1 (2T) SPACE 25 26 25 26 - - #12- 1/2. "C ELEV, ROOM 27 2a 27 28 SPACE 29 30 29 30 I SPACE 31 32 31 32 33 34 33 34 35 36 35 36 37 38 37 3111 39 40 39 40 41 42 41 42 I SUBTOTAL 5,400 TOTAL 4 16,400 (46A) 11,000 SUBTOTAL LOAD TABULATION FN 114 II - 4ro,4 � I NL 11511 4 &,4 TOTAL V.A BREAKER TRIP NL IIL/ II .40,4 f'NL 11 l l 11 = 9-1.4 fRE T,4 I 1 300,4 (="6T) TC.)T,4L = 581,4 (a) (a) (a) NP'LAA SP 120/208V PANEL "H" 200A MCB 3PH,4W (22,000 AIC) SURFACE MTD — _ BRANCH CIRCUITS - LOCATION WIRE AND CONDUIT TOTAL V.A BREAKER TRIP CKT N0. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A 2nd. FLOOR CORR, #12 -1/2 "C 700 1P -20 1 2 3P 7000 ELEVATOR STAIRS LTG, U-j 600 1 P -20 3 4 100 7000 3 #3 -1 "C (20 HP) TEMP. LTG, N LL 600 \ J Q 5 G � + 7000 TEMP. LTG. f — w W 600 � �y V J 7 8 1P -20 600 #12 -1/2 "C ELEV. PIT CORR, REC. (1st.FL) N 600 Z Z 9 10 0 600 Q J ELEV. CAR CORR, REC. (2nol.FL) 0 600 11 12 W 600 1st. FL. RESTROOM 1st, FL. CORR. < a 600 - 13 14 Q 600 2nd. FL. RESTROOM TELEPHONE 600 L 15 16 1 600 OUSIDE REC. FIRE ALARM 600 17 15 2P 2750 2 #10 -1/2 "C AHU C PARKING LTG. 600 X 19 20 1 30 2750 (5 KW) PARKING LTG. 600 21 22 2P (1500) 2 #10 -1/2 "C C. U, C OUTSIDE LTG. 600 23 24 30 (1500) 1 (2T) SPACE 25 26 1P -20 600 #12- 1/2. "C ELEV, ROOM 27 28 SPACE 29 30 I SPACE 31 32 33 34 35 36 37 3111 39 40 41 42 SUBTOTAL ---------- 7,300 1 TOTAL = 36,1100 (102A) 29,500 SUBTOTAL (a) ON -TIMER rzLEGTRIGAL NOTiES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2, COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY, 3, ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. AND ANSI/EIA/TIA -510 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENEMY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINEE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS, 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR, IT WILL BE H15 RESPONSIBILITY TO SECURE AND PAY FOR ANY PCRMIT5, CERTICATES OF INSPECTION, AS REQUIRED. 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT ME MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER, AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OIUVE R. 5. CLEAN UP SUCH TRASH AND DE15RI5 GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLE55 SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS, Tl. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL I-IEET WITH THE REQUIREMENTS OF UNDERWRITi R5' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLE$$ OTI- IERW16E INDICATED. LIKE ITEMS SHALL BE THE PRO - DUCT OF A SINGLE MANUFACTURER. 10. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 2DO -122. ii. LOCATION OR OULETS IN ELECTRICAL DRAWING$ IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12, PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. 13, A/C EQUIPMENT WIRING, BREAKER AND FU5E SIZES ARE BASED ON A/C EQUIPMENT 6PECIFIED ON ORIGINAL CONTRACT DRAWINGS, CON- TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE A50VE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY W/NEC 110 -26) 10 FT. LONG li�^_wr- ) NTS �LDG. STEEL FOUNDATION 2nd. FLOOR ELECTRICAL LEGE-ND FLUORESCENT STRIP FLUORESCENT LIGHTING FIXTURE - SURFACE MTD. I-Q WALL MOUNTED LIGHTING FIXTURE UNDER CABINET FLUORESCENT LIGHTING FIXTURE ® EXIT LIGHTING FIXTURE 2'x2' FLUORESCENT LAY -IN 2'x4' FLUORESCENT LAY -IN 0 CEILING MOUNTED LIGHTING FIXTURE O LIGHTING FIXTURE TYRE LIGHTS ON EMERGENCY CIRCUIT EMERGENCY FIXTURE - BATTERY TYPE 'rn MOTOR RATED SWITCH 20A,120/277 VAC SINGLE POLE TOGGLE SWITCH,SPECIFICATION GRADE 4' -0" ° A.F.F. LETTER DENOTES LIGHTS SWITCHED. $3 THREE WAY TOGGLE SWITCH SD DIMMER SWITCH =@C RECEPTACLE, 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE, MTD. 18" A.F.F. (C - INDICATES COMPUTER USE) cn 20A, 125V, 3 WIRE GROUND TYPE SPECIFICATION GRADE QUADRUPLEX RECEPT. MTD. 14" A.F.F. 20A 125V, 3 WIRE GROUND TYPE SPECIFICATION GRADE DUPLEX RECEPTACLE 6" ABOVE COUNTER (U.O.N.) GFI GROUND FAULT INTERRUPTER SPECIAL RECEPTACLE OF NEMA TYPE AS INDICATED ON PLANS. PROVIDE MATCHING PLUG OF FLOOR MTD. RECEPTACLE 1 P /20A -12OV. Q JUNCTION BOX �C CLOCK OUTLET TELEPHONE OUTLET, 19" A.F.F. TELEPHONE OUTLET, MTD 54" A.F.F. ® TELEPHONE OUTLET, FLOOR MTD. D� DATA OUTLET SP SPEAKER OUTLET `J THERMOSTAT N TELEVISION OUTLET Eo PULL BOX, SIZED PER NEC ELECTRICAL PANEL, SURFACE MOUNTED .f"""a -0 ELECTRICAL PANEL, FLUSH MOUNTED 3Gol-�-� SAFETY DISCONNECT SWITCH, `O= SWITCH SIZE, 3 =No. OF POLES, 4du' 40 =FUSE SIZE, O =NON FUSED MAGNETIC MOTOR STARTER WITH THLRMAL OVERLOADS. NEMA 1 ENCLOSURE F(411 COMBINATION MOTOR STARTER /DISCONNECT SWITCH [�]T TRANSFORMER - SIZE /RATINGS AS SHOWN MECHANICALLY -HELD LIGHTING CONTACTOR, SIZE AS SHOWN © NEMA 1 ENCLOSURE ELECTRICAL MOTOR - 3HP SHOWN EXHAUST FAN —F— FIRE ALARM CONDUIT LOOP + CONDUIT RUN -DOWN CONDUDIT RUN -UP CONDUIT RUN - CONCEALED - - - - -- CONDUIT RUN - EXPOSED '� rU FLEXIBLE CONDUIT HOMERUN TO PANEL - TICKS INDICATES NUMBER OF WIRES. ALL WIRE SIZES NOT INDICATED TO BE # 12 AWG, LONG TICK INDICATES NEUTRAL, SHORT TICKS INDICATES HOT > ,il • a• w •r • w • y •W YY G • y V • W • G • V y G a • • w W V W Y G V W • V G y Gu G W • V V • V V V G• Y V V V i Gvu r ••yy •a•ii •ir GGGYW • Y WWW• • � i ` • • • r • G y • Y• u G YWi• W VGGGV r 4V• W • JOB #: 013 -080 GUERRERO /GONZALEZ ENGINEERS, INC. MichG ael C. Guerrero, P.E. Mechanical Eng. Uc. #15235 Rafael L. Gonzalez, P.E. Electrical Eng. Lic. #11057 7tn TAMIAMI CANAL RD. Miami, Florida 33144 Tel. (305) 262 -31344, Fox (305) 262 -11211 E-mail: PROJECTS ■GUERREROGONZALEZENGINEERS.COM CA# 0007612 Z U N ■ (0 0 T- (y) a 0 L LU (� 0 U-j � LJ J Q X J i N LL \ J Q ::E � + w f — w W � �y V J 00 I0j ��/� 'J J N Z Z N 0 Q J U vJ W 0 E—! W 0 Z V < a 0 Z Q nIn LL W © L C) U CD `3 1 1 = CL/ 0 Ln no >n C) 0 w O D c_ O o n cL CL PANELBOARD RISER DIAGRAM �l SCALE i�.� °- 1 ' -011 DATE 0GIOG/ 13 ,JOB 1 3 1 1 - SHEET i w E -4 OF 4 SHEETS 9/3/2013 9:23:45 AM RAUL R. SOTOLONGO • AR -7712 JENNIFER MALLON SALMAN • AR -17131 rr c r' c , G I