Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13-1396-067
I V III _ I i j NOTE) FIRE ALARM SYSTEM IS SCHEMATIC ONLY, FIRE ALARM CONTRACTOR TO PR ❑VIDE WORKING PLANS FOR APPROVAL, NOTE; SEE FLOOR PLANS FOR EXACT LOCATION/NUMBER OF DEVICES, 2ND, FLOOR I F I(HS) I F I(HS) I F I(HS 2) 11 1 FLOOR F HS F HS F HS F HS F HS I I--- -- WIRE LEGEND A (INITIATING) -- 2/C #19 (CU) -- 3/4' B (ALARM) -- 2/C #14 (CU) -- 3/4' ALL W1R1NG C ❑PPER APPROVED FOR FIRE ALARM USE PR ❑VIDE EMERGENCY FORCE NOTIFICATION IN ACCORDANCE WITH FFPC 101133.3,4.3.2 - IA,211 Ir C INTE 4'x 4' FOR TYPICAL N,T,S. . --I I-- LE S D S hIS HS HS SL 2A 2A 2A S D S SL �2A 2A H S FACP ELEV, ROOM 2=�C1) 1#6 (CU) H -17 FIRE ALARM RISER ALL WIRING ABOVE CEILING SPACE IF USED FOR RETURN AIR SHALL BE RATED FOR USE IN RETURN AIR PLENUMS, G SPACE -ITY * 52 -C -36 /ER L PLANK PLATE :T FOR TELEPHONE P OUTLET DETAIL FIRE ALARM SYSTEM FACP FIRE ALARM CONTROL PANEL MODEL FS -250 MANUAL PULL STATION — HMS -5 sa SMOKE DETECTOR - MODEL HFP --11 Do DUCT DETECTOR - HP- 11 -AD -HR HEAT DETECTOR - MODEL HFT -11 ,s HORN /STROBE - U -MHIU -MCS is SPEAKER /STROBE -MODEL S -LP -MCS SL STROBE LIGHT - MODEL U -MCS T INTELLIGENT MONITOR MODULE ABOVE NUMBERS BASED ON "SEIMENS" FIRE ALARM NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA -72A, 72B AND 72C; NEC ART, 760 AND ALL LOCAL APPLICABLE CODES, 2. SYSTEM SHALL BE NON -CODED LOCATION OF DEVICES AS SHOWN. CONTROL. PANEL SHALL HAVE INTEGRAL BATTERY AND CHARGER T❑ BE USED IN CASE OF POWER FAILURE, SYSTEM SHALL BE ELECTRICALLY SUPERVISED WITH TROUBLE Al -ARM, 3. CONTRACTOR TO FURNISH SHOP DRAWINGS TO ARCHITECT /ENGINEER FOR APPROVAL BEFORE INSTALLATION, 4, ALL COMPONENTS SHALL BE U,L, LISTED FOR NFPA -72, 5. SYSTEM SHALL BE POWER LIMITED, 6. VISUAL ALARM PER ANSI A117, 1, 26 AND FLORIDA BUILDING CODE CHAPTER 515,3 AND ADA, 7, FIRE ALARM SYSTEM SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF FLORIDA STATUTES 61015- 33,006 ITEMS A THRU F. FIRE ALARM; SYSTEM OPE- RATION1 A, UPON ACTIVATION OF ANY ALARM INITIATING DEVICE (MANUAL STATION, FLOW SWITCH, HEAT DETECTOR, OR SMOKE DETECTOR ) THE FOLLOWING SHALL OCCUR: 1. ALL HORNS SHALL SOUND A NON -CODED ALARM, 2, VISUAL STROBES SHALL FLASH, 3, A ZONE INDICATION SHALL. LIGHT AT THE CONTROL UNIT, 4, ACTIVATE SMOKE EVACUATION SYSTEM 5, AUTOMATIC SIGNAL SHALL BE SENT TO LOCAL FIRE DEPARTMENT, B. EACH AIR HANDLING UNIT SHALL BE SHUT -DOWN BY IT "S DEDICATED DUCT DETECTOR VIA FAN SHUTDOWN RELAY, 1, FAN SHUT DOWN RELAYS SHALL BE ENERGIZED AND SHALL INTERRUPT CONTROL POWER TO AIR HANDLING UNITS, 4'W x VH x 3/4" - 12 "APP, P, PAINTED TELEPHONE 50� 6 AW 1,511-2411 2 - 2" CONDUIT TO P COORDINATE LOCATION WITH 55T. NT6 MIN. TO aCH SPACE GROUND FLOOR CONTRACTOR TO 5TUS UP TELEPHONE CONDUIT ON 1_BOTTOM LEFT CORNER OF TELEPHONE PLYWOOD ITEM5 TO BE- FgO\, lD FOFZ TELEPHONE SEi;PVIGE 1, 110 VAC DUPLEX RECEPTACLE 2. EXTENSION OF AN APPROVED COLD WATER PIPE OF-06 , AUJG TO COLD WATER PIPE. 3. 4'W x S'H x 3/4" FAINTED TELEPHONE PLYWOOD. 4. ALL CONDUITS TO SE EQUIPPED WITH PULL STRING5. 9 WA /CEI C NEW WALL OR CEILING MOUNTED INFRARED OCCUPANCY DETECTOR RATED AT 24 VOLTS, WIRE IN-SERIES WITH LIGHT SWITCHES CONTROLLING LIGHT FIXTURES CONNECTED TO NORMAL POWER ONLY IN RESPECTIVE AREAS AND AS PER MANUFACTURER'S WIRING DIAGRAM, LIGHTOLIER CONTROL 'OSC' SERIES PROVIDE POWER PACK RATED AT 13 AMPS, QUANTITY AS REQUIRED, LIGHTOLIER CONTROLS 'OSPS' SERIES PROGRAM AUTOMATIC TIME SETTING TO TURN LIGHTING OFF WITHIN 30 MINUTES OF AN OCCUPANT LEAVING THE AREA, COORDINATE EXACT LOCATION IN THE FIELD (TYPICAL). ❑S LIGHT S4JITr.H / ❑CCUPANCY__SENSER COMBINATION LIGHT SWITCH WITH INFRARED OCCUPANCY SENSOR, W WIRE TO LIGHT FIXTURE AS PER MANUFACTURER'S WIRING DIAGRAM SHOWN AND AS REQUIRED. PROGRAM AUTOMATIC TIME SETTING TO TURN LIGHTING OFF WITHIN 30 MINUTES OF AN OCCUPANT LEAVING THE AREA. LIGHTOLIER CONTROLS ITS2U OR EQUAL (TYPICAL). NOTES' 1— PROVIDE INDIVIDUAL LIGHT SWITCH /OCCUPANCY SENSOR AT ALL ENCLOSED OFFICES /EXAM ROOMS /LAB LOUNGE ETC NOTES: 1. BASED ON LIGHTOLIER CONTROL 'OSC' SERIES OCCUPANCY SENSORS, REFER TO SPECIFICATI ❑NS FOR EXACT REQUIREMENTS, 2, REFER TO LIGHTING PLAN DRAWINGS FOR DEVICE TYPE, GENERAL LOCATION, LIGHT SWITCH CONFIGURATIONS AND CIRCUITING REQUIREMENTS. 3. DETAILS INDICATE THE GENERAL ARRANGEMENT AND INTENT OF CONTROL CIRCUIT, TYPICAL CONTROL SHEME SHOWN, LOAD AND CIRCUIT TYPES MAY VARY. 4. POWER RACK RATED UP TO 20 AMP LOAD, PROVIDE ADD A —RELAY COMPANION(S) IF ROOM /AREA LIGHTING L ❑AD EXCEEDS 20 AMPS, 5, MOUNT POWER PACK AND ADD —A —RELAY UNITS IN SEPARATE .J —BOX ABOVE CEILING OR IN BALLAST CAVITY OF LIGHT FIXTURE NEAR ROOM SWITCH(ES), 6. PROVIDE 18 AWG OR LARGER LOW VOLTAGE WIRING BETWEEN POWER PACK SERIES AND OCCUPANCY SENSOR. 7, INSTALL SYSTEM & WIRING IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. LOCATE SENSOR SO IT HAS THE BEST VIEW OF THE ENTIRE COVERAGE AREA AND IS POSITIONED TOWARD THE AREA OF GREATES TRAFFIC, TYPICAL CEILING MOUNTIED OCCUPANCY SENSOR CONTROL _CIRCUIT DE7AIL,9 NOT TO SCALE OFFIOE BUILDING 1400 S.W. 59TH I- L,50UTH MIAMI,FLORIDA LIGHTING FIXTURE 5GHEDULE TYPE MANUFACTURER CATALOG NUM /ER MOUNTING VOLTS LAMPS REMARKS A LITHOLIER COS232- 120 -SO SURFACE 120V (2) F32T5 WRAPAROUND AE LITHOLIER CDS232- 120 -SO -EM SURFACE (2) F32T5 WRAPAROUND �t,L l4- RA Z D LITHOLIER U V'YU VV«Y• U V M M Y « 2 F32T5 STAIRS BE C LITHOLIER LITHOLIER LSW4232- 120 -SO -EM 11012F642U SURFACE RECESSED 120J 120V (2) F32T8 1 -32WT STAIRS W EM TRANSFER HI -HAT --- CE LITHOLIER 11012F642U RECESSED 120V 1 -32WT - -- HI -HAT W /FM TRANSFER - D LITHOUER - El1i1_TTW ; - SURFACE 120V 7WTS TWO HEAD EMERGENCY LIGHT E LITHOLIER NXF D3RWH UNIVERSAL 120V LED EXIT SIGN WITH BATTERY F LITHOLIER 54111WHU WALL 120V 2 -17W TS VANITY FE LITHOLIER 54SIWHU -EM WALL 120V 2 -17W TS W /EM TRANSFER G EXCELINE RLW200INGC WALL 120V 1 -15OW A21 ELEVATOR PIT H LITHOLIER (NOT USED) RECESSED 120V J WEATHERPROOF J LITHOLIER Q 0� WALL 120V <U WEATHERPROOF LLJ Uj , a (!� 0) 1, Z � � N LO y • y v • y u - • « y U U y Y • • • y • U G U• V U U M • Y U V y• V 4« • • • • u M U V 4 « . • y • r (REVISIONS BY 1-- B.D.0 02/01/14 GG U V'YU VV«Y• U V M M Y « U V V U • M « • r V •• V Y U yV Y •• • •V • " Y•uTf. - r i 11 ■ `-.' M 0 - J n C� ' Q ° w L0 © 0 Z J�. Uj C/) " J X Z Q 0� LL <U 0 ° LLJ Uj , a (!� 0) 1, Z � � N LO a YJ co W w, 0 }- W O Z Cl7 < 0 0 Z © W C0 _j W DO NOT DISTALL FIRE ALARM PER THIS DRAWING! BEFORE INS TA%LATiON Fire Alarm contractor's working plans shall be submitted for permit approval to Miami - Dade County Fire Depart, t. for s g Pe � only: Date 7' JOB #: 013 --02S0 I NO W u \' J �D__ __j Q0c-)aa LE V �aa-�a Q V 1 (D ° a Q_, �a � LL._ n I; .t, BLDG PLAN ROOF PLAN r SCALE Y4 "- DATE 06/06/ 1 3 JOB 131 1 SHEET E -3 tl OF SHEETS GUERRERO /GONZALEZ ENGINEERS, INC. Michael C. Guerrero, P.E. Mechanical Eng. L:c. #15235 Rafael L. Gonzalez, P.E. Electrical Eny. Lic. #11057 750 TAMIAMI CANAL RD, Miami, Florida 33144 Tel. (305) 262 -3944, Fax (305) 262 —:211 E—mail: PROJECTS •GUERREROGONZALEZENGINEERS.COM CAS% 9/3/2013 9:23:45 AM RAUL R. SOTOLONGO - AR -7712 JENNIFER M ALL ON SALMAN • AR -171$1