Loading...
14-124-001, It REVISIONS C C oc SYMBOL DESCRIPTION W °° P1.3.6 15/75cd m U `� in tn -- BATHROO Q 10 M EDWARDS VIGILANT V —PS ED ADDRESSABLE PULL STATION EDWARDS VIGILANT in C J cn as CONTROL RELAY MODULE EDWARDS VIGILANT "o C U cJ cJ ° I C W QmlQ4 U� C) L HORN /STROBE WALL MOUNT EDWARDS VIGILANT MG1 F —HDVM Iti 3 44 � 0 th WG4WF —HVMC w�� ` uj C a- 75cd FIRE ALARM NOTES 1— FIRE ALARM SYSTEM SHALL BE U.L. LISTED AND NFPA 72 APPROVED AND COMPATIBLE. 2— RISER INTERCONNECTIONS ARE DIAGRAMMATIC ONLY. 3— TOTAL ACTIVE AREA: 8,112 SO. FT. 4— FIRE ALARM SYSTEM TO BE "POWER LIMITED". 5— THE INSTALLATION SHALL COMPLY WITH NFPA 70 CHAPTER 760. 6— ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION, LOCAL CODES AND NFPA. 7— ALL CONDUCTORS SHALL BE SOLID OR STRANDED COPPER. 8— MAXIMUM CONDUIT FILLS TO BE 403'.. MINIMUM RACEWAY SIZE 9— SYSTEM SHALL BE GROUNDED ACCORDING TO MANUFACTURER SPECIFICATION AND NEC ARTICLE 250. 10 —ALL WALL PENETRATION SHALL BE MADE WITH APPROVED (NEC) ELECTRICAL TUBING AND SEALED WITH A U.L. LISTED FIRE STOPPER. (SEE FIRE STOP DETAIL). 11 —THE 120V AC POWER FEED FOR THE FIRE PANEL MUST BE FROM A DEDICATED CIRCUIT AND THE BREAKER MUST BE IDENTIFIED FIRE ALARM CIRCUIT AND HAVE A LOCK ON IT. 12— VISUAL ALARM PER ANSI A117.1 APPROVED. WALL MOUNTS 80" A.F.F. TO BOTTOM OF STROBE LENS. 13 —ALL NEW WIRING INSTALLED IN DUCTS, PLENUMS AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP, AS PER NEC (NATIONAL ELECTRIC CODE) ARTICLE 760 -61. 14—ALL N.A.C. WIRING SHALL BE CLASS "B" (STYLE "Y"). SIGNALING LINE CIRCUIT WIRING SHALL BE CLASS "B" (STYLE "4 "). 15— HORN /STROBES SHALL BE LOCATED AS PER NFPA 72, CHAPTER 7. 16— STROBE LIGHT CIRCUITS SHALL BE SYNCHRONIZED AT 1HZ PER NFPA 72. 17 —NEW FIRE ALARM DEVICES TO BE COMPATIBLE WITH THE NEW CONTROL PANEL AND RATED FOR FIRE USE. 18 —NEW SYSTEM IS CLASSIFIED AS CERTIFICATED FOR CENTRAL STATION SERVICE PER NFPA 72 8.3. 19 —THE SYSTEM SHALL HAVE BATTERY BACK UP FOR 24 HRS IN STANDBY MODE AND 5 MINUTES IN ALARM. 20— HEIGHT OF FACP NOT TO EXCEED SIX FEET TO TOP OF ENCLOSURES. 21 —ROOM CONTAINING FACP IS MECHANICALLY-VENTILATED. 22— UNLESS OTHERWISE NOTED ALL CEILING HEIGHTS DO NOT EXCEED 10' -0" AND ALL CEILINGS ARE FLAT. SCOPE OF WORK: 1. FURNISH AND INSTALL NEW FIRE ALARM SYSTEM AS FOLLOWS: 1 FIRE ALARM CONTROL PANEL 3 ADDRESSABLE SMOKE DETECTOR 7 ADDRESSABLE PULL STATION 3 CONTROL RELAY MODULE 2 HORN /STROBE WP WALL MOUNT 8 HORN /STROBE WALL MOUNT 1 STROBE LIGHT CEILING MOUNT 11 STROBE LIGHT WALL MOUNT THE WORK TO BE DONE COMPLIES WITH THE FLORIDA FIRE PREVENTION CODE 2010 EDITION, NFPA 72 2007 EDITION AND NFPA 70 2008 EDITION THIS IS A NEW 2 STORY NON— SPRINKLED BUILDING FIRE ALARM LEGEND SYMBOL DESCRIPTION MANUFACTURER P1.3.6 15/75cd m ' i I 35c' -- BATHROO 5TORAG I t %75c EDWARDS VIGILANT V —PS ED ADDRESSABLE PULL STATION EDWARDS VIGILANT GSA —M270 CR CONTROL RELAY MODULE EDWARDS VIGILANT GSA —CR STROBE LIGHT WALL MOUNT EDWARDS VIGILANT I C STROBE LIGHT CEILING MOUNT EDWARDS VIGILANT MGCF —VM M< HORN /STROBE WALL MOUNT EDWARDS VIGILANT MG1 F —HDVM LOLL PI WCp EDWARDS VIGILANT WG4WF —HVMC ` Pl.l. 15 /75cd 75cd co OFFICE 5 OFFICE 4 OFFICE 3 OFFICE 2 co — _ 1 TR_A5H AREA tO� `/ LL LL j 'E ® FIRE ALARM PLAN (2ND FLOOR) .. U O c L cu ' SCALE: 1/8" = V -0" w U) " ®. FIRE ALARM PLAN (IST FLOOR) ­3 02 C:) i_ :03 THIS IS A FM PLACARDED SCALE: 1/8~ = l'-o" 0 w O d" O FIRE ALARM SYSTEM 0- U co FIRE ALARM NOTES 1— FIRE ALARM SYSTEM SHALL BE U.L. LISTED AND NFPA 72 APPROVED AND COMPATIBLE. 2— RISER INTERCONNECTIONS ARE DIAGRAMMATIC ONLY. 3— TOTAL ACTIVE AREA: 8,112 SO. FT. 4— FIRE ALARM SYSTEM TO BE "POWER LIMITED". 5— THE INSTALLATION SHALL COMPLY WITH NFPA 70 CHAPTER 760. 6— ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH MANUFACTURER RECOMMENDATION, LOCAL CODES AND NFPA. 7— ALL CONDUCTORS SHALL BE SOLID OR STRANDED COPPER. 8— MAXIMUM CONDUIT FILLS TO BE 403'.. MINIMUM RACEWAY SIZE 9— SYSTEM SHALL BE GROUNDED ACCORDING TO MANUFACTURER SPECIFICATION AND NEC ARTICLE 250. 10 —ALL WALL PENETRATION SHALL BE MADE WITH APPROVED (NEC) ELECTRICAL TUBING AND SEALED WITH A U.L. LISTED FIRE STOPPER. (SEE FIRE STOP DETAIL). 11 —THE 120V AC POWER FEED FOR THE FIRE PANEL MUST BE FROM A DEDICATED CIRCUIT AND THE BREAKER MUST BE IDENTIFIED FIRE ALARM CIRCUIT AND HAVE A LOCK ON IT. 12— VISUAL ALARM PER ANSI A117.1 APPROVED. WALL MOUNTS 80" A.F.F. TO BOTTOM OF STROBE LENS. 13 —ALL NEW WIRING INSTALLED IN DUCTS, PLENUMS AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP, AS PER NEC (NATIONAL ELECTRIC CODE) ARTICLE 760 -61. 14—ALL N.A.C. WIRING SHALL BE CLASS "B" (STYLE "Y"). SIGNALING LINE CIRCUIT WIRING SHALL BE CLASS "B" (STYLE "4 "). 15— HORN /STROBES SHALL BE LOCATED AS PER NFPA 72, CHAPTER 7. 16— STROBE LIGHT CIRCUITS SHALL BE SYNCHRONIZED AT 1HZ PER NFPA 72. 17 —NEW FIRE ALARM DEVICES TO BE COMPATIBLE WITH THE NEW CONTROL PANEL AND RATED FOR FIRE USE. 18 —NEW SYSTEM IS CLASSIFIED AS CERTIFICATED FOR CENTRAL STATION SERVICE PER NFPA 72 8.3. 19 —THE SYSTEM SHALL HAVE BATTERY BACK UP FOR 24 HRS IN STANDBY MODE AND 5 MINUTES IN ALARM. 20— HEIGHT OF FACP NOT TO EXCEED SIX FEET TO TOP OF ENCLOSURES. 21 —ROOM CONTAINING FACP IS MECHANICALLY-VENTILATED. 22— UNLESS OTHERWISE NOTED ALL CEILING HEIGHTS DO NOT EXCEED 10' -0" AND ALL CEILINGS ARE FLAT. SCOPE OF WORK: 1. FURNISH AND INSTALL NEW FIRE ALARM SYSTEM AS FOLLOWS: 1 FIRE ALARM CONTROL PANEL 3 ADDRESSABLE SMOKE DETECTOR 7 ADDRESSABLE PULL STATION 3 CONTROL RELAY MODULE 2 HORN /STROBE WP WALL MOUNT 8 HORN /STROBE WALL MOUNT 1 STROBE LIGHT CEILING MOUNT 11 STROBE LIGHT WALL MOUNT THE WORK TO BE DONE COMPLIES WITH THE FLORIDA FIRE PREVENTION CODE 2010 EDITION, NFPA 72 2007 EDITION AND NFPA 70 2008 EDITION THIS IS A NEW 2 STORY NON— SPRINKLED BUILDING FIRE ALARM LEGEND SYMBOL DESCRIPTION MANUFACTURER MODEL FAC FIRE ALARM CONTROL PANEL EDWARDS VIGILANT VS2 —G O ADDRESSABLE SMOKE DETECTOR EDWARDS VIGILANT V —PS ED ADDRESSABLE PULL STATION EDWARDS VIGILANT GSA —M270 CR CONTROL RELAY MODULE EDWARDS VIGILANT GSA —CR STROBE LIGHT WALL MOUNT EDWARDS VIGILANT MG1 F —V1575 C STROBE LIGHT CEILING MOUNT EDWARDS VIGILANT MGCF —VM M< HORN /STROBE WALL MOUNT EDWARDS VIGILANT MG1 F —HDVM HORN /STROBE WEATHER PROOF EDWARDS VIGILANT WG4WF —HVMC FIRE ALARM SYSTEM TO IRE INSTALLED IN ACCORDANCE WrM NFPA 72; 70,101 - APPROVED NIIMM -DADE COUNTY FIRE DEPA3 BLDG. PERMIT FIRE ALARM- FIRE SUPPRESSION WATER MAIN EI T. DATE: B1F FIRE ALAPM SHALL BE A CENTRAL STATION SERVICE. A CERTIFICATE OR PLACARD SHALL BE POSTED AT FINAL INSPECTION, AS PER NFPA 72 FlRE -LINK CORPORATION CERTIFICATE OF AUTHORIZATION 30361 ENRIOUE PEREZ P.E. ELECTRICAL ENGINEER, FL REQ Na71404 10277 N.W. 128 TERRACE HIALEAH GARDENS, FLORIDA 33018 TEL- (788)449 -4354 Emai: enrique.perez.20100gmai.com • o I �•, ice. Col t 3 DRAWN IN SCALE 1/8" 1' -0" PROJ. NO. DATE- 12/10/13 FA -01 1 OF 3