Loading...
13-73-003A _ I' MINERIAL WOOL WRAPPED WITH WIRE MESH ALL SIDES. 6. 1 6 . , DbICT SIZE A5 PER -R.�AN 022 GA, G/I INTERIOR LINER NON- COMBUSTAiBLE MAT'L—­1 INSULATED CUR5 14/5RAGKET5 - 014 GA GA D' 4 HOLE, 2'X2'X2' WELDED TO TOP OF HOOD D -01 I' MINERIAL WOOL WRAPPED WITH WIRE MESH ALL SIDES. I' 2" t IN ,]$ it wQ DUCT SIZE U A3,ER PLAN 0 N 022 GA. G/1 INTERIOR I (X � L_ I _LINER d 5/8' TYPE 'X' ALL SIDES. i-- _COMBUSTIBBLE MAT'L-----N­I COMBUSTIBLE MATERIAL-- ----°—� INSULATED CUR5 FIRE Ck45E (6�44F ' IC -02 1=C -01 %/F'- APPROPRIATE SIZE "16 GA G /I, F/PERIMETER FIRESTOP GASKET, BOLT TO DUCT C/L IN 0 HOLE 1' T /HEAD NUT 4 WASHER 10X10XE X3'G /1 ANGLE WELDED TO TOP OF VENT'R, I EXH. DUCT! Z I" X 1D' THD. I EX,, ,,nED !BOTH ! BOLTN)ASHER < NUT p� ia� .i ENDS ! 6, + EA. CORNER, 24" OIC I' FOUR! MIN. 2'x2'x i CORNE%S ALY 4NGLE A/BOLT -1 P/PAN ' A/I SPACE L G/I AN"uLE G/I ANGL t 5/1 EGS ( , I ip' X Ip' X E' i' X 2D' LAG BOLT /WASHER ' DISTRIB'N BOX (THREE REQ. EACH BRACKET) 12' O/C MAXINUM, THE ABOVE WALL BRACKETS. THE ABO ROOF DUCT SUPPORT WILL PROVIDE SERIES OF CONN'S WILL PROVIDE A CONNECTION WILL PROVIDE A CONNECTION THE SAME AS D -01. TO GBU WALL THAT WILL WITH- TO ROOF DECK THAT WILL STAND WIND LOADS OF 146 MPH WITHSTAND WIND LOADS OF 146 WITH SAFETY FACTOR OF AT mph WITH SAFETY FACTOR OF LEAST FOUR (4). At LEAST FOUR (4) —0� D -10 D -11 D -12 W/P MAT'L ROOF SLAB + III REDHEAD-/"' CONC. WEDGE ANCHOR 3/8 `X3' 3/8' H/R EXTENDS STRAIGHT UP TO R/H ANCHOR D -1_1 HOOD W,V LL ( inside) LOCKNUT WASHER HEX NUT (TORQUE TO in) r 80 Ibs) THERMO SEN50R D -18 i act %D 4UT HOOD / 1= ro -51zE AS REQ' FIRE MASTER WRAP 31­11-15A INSTALLED � AS PER CODE. / 61-AIB - ABOVE \ I 1D -09) iF _ A/FLbW i \ I I • L !�..... - ! J D -20 IF ii EXHAUST FANS HINGED TO CURB 4 'X' CABLES AS PER CODE, git; TYP, E/FAN CURS LENGTH AS REQUIRED 3/8' HOLE 1' -0' O /C, TRIM CAP D -05 D -13 BAR JOISTS 15TRUCT SUPPORT'S HOOD 4 ACCESS'S ALL AS PER CODE. UNISTRUCT D -21 FAN IN RELAY `135 IF 1 0v NORMALLY THERMO 10 OPEN SENSOR U LOCATED y W' f U u • V • Y 006 100'HIGH MANUAL SWI CH INSIDE HC 20 AMP. FIRE RATED ENCLOSURE _ 2,:0' •••• •u• • uy•y• Uir ' ••• • Y • u r r y • ' • • u Y o y•rs�r ••• 00 y • Y V •vW• u U • 2' EXHAUST VELOCITY 1500 4 2200 FPM. U- U- LJ O NN / RADIUSED LIW CONC. DECKING w w '� ti DUCT 08 EXHAUST DUCTS CONTAINED IN FIRE RATED ENCLOSURES, SHALL HAVE 6 MINIMUM CLEARANCE cu � PITCHED 1/4 X 6" SELF TAPPING BUILT -UP ROOF BETWEEN DUCTWORK 4 NON - COMBUSTIBLE MATERIALS. cD 1/4' PER FT, i \ / I WWITH SCREW, TOGGLE BOLT OR SUPPLY DUCTWORK �+ a THD ROD w CORNERS 4 12' o U U C O O/C MAXINUM FOR ALL FAN 4 09 SUPPLY DUCTWORK CONSTRUCTED, INSTALLED IN ACCORDANCE WITH SMACNA STD. 1' G/I T D. D GT CURBS 4 AND PLATFORMS. SUPPLY DUCTWORK (5ro) SHALL BE "24 GA. G/I. (PITTSBURG CON5TR'N) VELOCITY 1200/1500 FPM. J � NI E. ILI ABOVE WILL PROVIDE A ROUND SUPPLY DUCTWORK l5/D), THERMOFIN, ALUMINUM 4 FLEX. SUPPLY AIR VEL. 1200/1500 I=PM- U- LU CONNECTION OF FAN CURB rn \TO ROOF THAT WILL WITH- GENERAL 0) SECTION PLAN STAND WIND LOADS OF 146 STEEL DECKING 10 EXACT LOCATION AND SIZE OF DUCTWORK FIELD JOINTS ACCESS PANELS OFFSETS ROOF CURBS 11�_ MPH wl LE SAFETY FACTORY INSULATION HANGER RODS AND BRACKETS TO BE COORDINATED 4 VERIFIED WITH ACTUAL FIELD CONDITIONS. OF AT LEAST FOUR l4). D -15 •- 1 • V • u • Y Uu • i • Yr• {. • 4 • u • , WALL PANELING 020 GA- Wessel 0 r Y U V U &us GENERAL NOTES: • 4 U i y W' f U u • V • Y 006 (EXHAUST 4 SUPPLY), VERIFY FINISHED CEILING HEIGHT. IF REQUIRED PROVIDE SOFFIT 11-� Li HEIGHT OF FAN 3' -4' MINIMUM FROM ROOF SURFACE (UNLESS OTHERWISE NOTED) 4 10-0' MINIMUM FIRE RATED ENCLOSURE _ r� o HORIZ'LY FROM FRESH AIR INTAKE OF ANY SUPPLY FAN. FIRE MODE REQUIRES EXHAUST FAN TO BE VENTILATOR: `iur• iyru0 OF Al R • • 01 STANDARD - VENTILATOR(5) SHALL BE OF ALL 015 GA, 5/5 (TYPE 304) 5/5 STAINLE55 5TEEti_ u Y y • Y r•`SAV` 0 AS U.L. YZHW SUBJECT 162. NOZZLES -PL'M, APP'E 4 DU'K -4-- P -+-- A -t- D �... Y•VY • yc r.. r OVENTILATION SYSTEM 0 EXTRACTORS (FILTERS). 02 ECONOMY - VENTILATOR(5) SHALL BE OF "IS GA. 5/5 (TYPE 400) AND /OR ALUMINIZED STEEL. CD Cu VAPOR PROOF FLUORESCENT RIGID STEEL FRAME MINIMUM 1 -1/4' (32mm) WORK PROVIDED BY OTHERS, OWNER, GENERAL CONTRACTOR (G /C): 20 G/C PROVIDES ALL NECESSARY FIRE5TOPPING, ELECTRICAL CONNECTIONS INTERCONNECTIONS ROOF- UNIVERSAL HOOD TECH, INC. U.L. "89492, GREASE DRAIN 03 ECONOMY - VENTILATOR(S) SHALL BE OF ALL "IS GA. (G /1) GALVANIZED IRON. PROJECTING ROD ISOLATION BUSHING 23 G/C PROVIDES PAINTING OF EXPOSED, EXTERIOR DUCTWORK 4 CURBS IF REQUIRED BY LOCAL CODES, � HINGED BASE 3/8'0 H/ROD EXTENDED TO THE HOOD Z w 04 ALL SEAMS AND JOINTS SHALL BE LIQUID TIGHT, CONTINUOUS WELDED. COMPLYING WITH NFPA -96, 010 TEK. SCREW NSF. 4 BARING U.L. LABEL. REMOVABLE "18 GAUGE GREASE GUTTER 4 8/5 CONTAINER MOUNTED EVERY 12' MIN. UNDER FILTER FRAME. FIRE DAMPER(5) SHALL BE PROVIDE FOR ALL MAKE -UP AIR DUCT COLLAR(S). FLAT ROOF CURB -FAN VENTILATOR(5) AND WOOD(S) SHALL SUPPORTED BY OVERHEAD STRUCTURE W /THREADEDD RODS (3/81) Z EXTENDED DOWN TO HANGER BRACKET5t WHERE OFFSETS OCCUR, TRAPIZE HANGERS OF UNI5TRUCT, G/I ANGLE AND I THREADED ROD WILL BE USED. SUPPLY AIR DUCT COLLARS (5 /C) PROVIDED W/FIRE CURB SECURED TO ROOF DAMPER NAILOR -HART UL 89492, WITH SUITABLE ACCESS THRU HOOD OR ACCESS PANEL. DECK WITH: 1/4'X6' SELF TAPPING SCREW.TOGGLE 05 VENTILATORS) TO OVERHANG (CAPTURE AREA) COOKING APPLIANCES 6" MINIMUM ALL AROUND. IF BOLL OR THD ROD � , DEEP FAT FRYERS ARE TO BE INSTALLED SHOW MINIMUM 16 SEPARATION TO SURFACE FLAMES OF AD- CORNERS 4 12'O /C MAX. JACENT COOKING EQUIPMENT OR SHOW 5/6 DIVIDER PANEL BETWEEN UNITS- Cn FOR ALL FAN CUR55 4 c� \ ' ' I 5 rE C T I ON I E OF FAN PLATFORMS ABOVE WILL E F - 1 PROVIDE CONNECTION OF 06 GREASE FILTERS (EXTRACTORS) ARE BAFFLE TYPE, 5/5 OR ALUMINUM OR GA AND OF PROPER SIZE, Y W QUANTITY, INSTALLED AT NOT LE55 THAN 45 deg. ANKLE AND U.L. FILE "R65g3 0 (D FAN CURB TO ROOF THAT WILL WITH STAND WIND EXHAUST DUCTWORK (E /D) rn LOADS OF 146 MPH WITH UCTED, INSTALLED IN ACCORDANCE WITH NFPA -96. LIQUID TIGHT, CONTIN- 01 "16 GA. G /I, CONSTRUCTED, co co .r % SAFETY FAGtORYOF At LEAST FOUR (4) UOUSLY WELDED, RADIUS ELBOWS, PITCHED 1/4' PER FOOT TOWARD HOOD WITH -OUT FORMING DIPS OR TRAPS WHICH MIGHT COLLECT RESIDUES. ACCE55 PANEL (A/P) APPROPRIATE SIZE t0 PERMIT PROPER CLEANING, AT 12' INTERVALS, W/FULL PERIMETER FIRE3TOP GASKET, SECURED WITH STUD BOLTS 4 WING NUTS. PROVIDE GREASE TROUGH W /DRAIN PIPE AND PLUG WHERE APPLICABLE. • - • • U-) 2' EXHAUST VELOCITY 1500 4 2200 FPM. U- U- LJ O NN / RADIUSED LIW CONC. DECKING w w '� ti DUCT 08 EXHAUST DUCTS CONTAINED IN FIRE RATED ENCLOSURES, SHALL HAVE 6 MINIMUM CLEARANCE cu � PITCHED 1/4 X 6" SELF TAPPING BUILT -UP ROOF BETWEEN DUCTWORK 4 NON - COMBUSTIBLE MATERIALS. cD 1/4' PER FT, i \ / I WWITH SCREW, TOGGLE BOLT OR SUPPLY DUCTWORK �+ a THD ROD w CORNERS 4 12' o U U C O O/C MAXINUM FOR ALL FAN 4 09 SUPPLY DUCTWORK CONSTRUCTED, INSTALLED IN ACCORDANCE WITH SMACNA STD. 1' G/I T D. D GT CURBS 4 AND PLATFORMS. SUPPLY DUCTWORK (5ro) SHALL BE "24 GA. G/I. (PITTSBURG CON5TR'N) VELOCITY 1200/1500 FPM. J � NI E. ILI ABOVE WILL PROVIDE A ROUND SUPPLY DUCTWORK l5/D), THERMOFIN, ALUMINUM 4 FLEX. SUPPLY AIR VEL. 1200/1500 I=PM- U- LU CONNECTION OF FAN CURB rn \TO ROOF THAT WILL WITH- GENERAL 0) SECTION PLAN STAND WIND LOADS OF 146 STEEL DECKING 10 EXACT LOCATION AND SIZE OF DUCTWORK FIELD JOINTS ACCESS PANELS OFFSETS ROOF CURBS 11�_ MPH wl LE SAFETY FACTORY INSULATION HANGER RODS AND BRACKETS TO BE COORDINATED 4 VERIFIED WITH ACTUAL FIELD CONDITIONS. OF AT LEAST FOUR l4). D -15 •- 1 HAZARD AREA ARE ALL INTERLOCKED TO ONE (1) ELECTIGAL SWITCH W/PILOT LIGHT. � 11 THESE NOTES ARE STANDARD FOR ALL PROJECTS UNLESS OTHERWISE NOTED. THESE SHOP DRAWINGS PREPARED FROM STANDARDS SETFORTH BY NRP.A, 11, 11A, 96 t U.L. LA50RTORY 4 N.S.F. IF WALL PANELING 020 GA- Wessel 0 o n THERE ARE ANY QUESTIONS CONCERNING THE ABOVE CALL LOCAL AUTHORITY HAVING JURISDICTION. (EXHAUST 4 SUPPLY), VERIFY FINISHED CEILING HEIGHT. IF REQUIRED PROVIDE SOFFIT 11-� Li — 0& D 01 — 08 D -15 •- 1 HAZARD AREA ARE ALL INTERLOCKED TO ONE (1) ELECTIGAL SWITCH W/PILOT LIGHT. Lu EXHAUST FAN: WALL PANELING 020 GA- C/L H /RODS, G/1 ANGLES 12 FAN HINGED TOO NONCOMBUSTIBLE ROOF CURB (18' HIGH, 416 GA G/1) PER NFPA -9b. DISCHARGE (EXHAUST 4 SUPPLY), VERIFY FINISHED CEILING HEIGHT. IF REQUIRED PROVIDE SOFFIT � � L HEIGHT OF FAN 3' -4' MINIMUM FROM ROOF SURFACE (UNLESS OTHERWISE NOTED) 4 10-0' MINIMUM FIRE RATED ENCLOSURE _ r� o HORIZ'LY FROM FRESH AIR INTAKE OF ANY SUPPLY FAN. FIRE MODE REQUIRES EXHAUST FAN TO BE COMPONENTS INCLUDING PIPING (B /1, C/P OR 5/5), SLEEVES, NOZZLES, MECHANICAL DETECTORS, OF CIO 'ON' WHENEVER FIRE EXTINQUISHING 5Y5TEM 15 ACTIVATED. ALL EXHAUST FANS SHALL BE LISTED CABLE, PULLEYS, LIQUID TIGHT FITTINGS, SYSTEM SUPPLY TANK 4 TESTING. L�L AS U.L. YZHW SUBJECT 162. NOZZLES -PL'M, APP'E 4 DU'K -4-- P -+-- A -t- D �... � 'ROOF.SLAB LIGHT FIXTURES. 0 EXTRACTORS (FILTERS). :. SUPPLY FAN: W/P MAT'L 13 FAN SHALL BE MOUNTED ON ROOF CURB (016 GA. G/U 10' -0' MINUMIM FROM EXHAUST FAN OR CD Cu VAPOR PROOF FLUORESCENT 51 L 15UPP 4 P /PAN PLUMBING VENT(S). SUPPLY FAN SHALL BE ELECTRICALLY INTERLOCKED WITH EXHAUST FAN AND Q BEAM W/P ROOF MAT'L ROOF 5LAB VENTILATOR FIRE SUPPRESSION SYSTEM. SUPPLY FAN TO BE 'OFF' IN CASE OF FIRE. • L�U.. Oa- B /CLAMPS l CLAMP FIRE PROTECTION SYSTEM (F.F.S.): � r` 4 UN15TRUC-T NUT 4 WOO ROOF -- --- - 14 THIS SCHEMATIC 15 NOT FOR CONSTRUCTION. REFER TO FIRE PROTECTION COMP'S CF.P.GJ SHOP (a SUPPORT'S DRAWING. VARIOUS MANUFACTURES OFFER DIFFERENT TYPES OF SYSTEMS, NOZZLES AND COVERAGE Q H/ROD'S 4 WASHER NUT 4 HEAD GONG m EXTEND UP II WASHER DG� ANCN9.R THE EXACT QUANTITY, LOCATION AND COVERAGE IS DETERMINED BY THE SHOP DRAWINGS. HOOD AS 3 /g. 3/8 "X3" uj PER CODE H/ROD X . I 15 THIS -SCHEMATIC; PREPARED SOLELY AS AN AID TO ARCHITIIGT'S, ENGINEER'S 4 GENERAL CONTRAG- (1u Q IT 4 PROVIDE. I I8 GA. Ga H /5TRAP TORS. SHOP DRAWINGS TO BE PROVIDED BY F.P.G. W /SEPARATE PERMIT. -�-+ ACCESS' Of5T3 N H. AS PER CO E (D BAR J013T5 3/8'0 H/ROD EXTEND 16 FIXED PIPED EXTINGUISHING SYSTEM IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTA- UP 4 THRU P/PAN S/A DUCT NENEOUS AUTOMATIC OPERATION UPON ACTIVATION. SYSTEM SHALL PROTECT VENTILATOR/HOOD, RECT. OR 0 DUCTWORK AND COOKING SURFACES ALL IN ACCORDANCE NFPA. AND LOCAL CODES. -4✓ Z 0 11 FIRE PROTECTION SYSTEM, GAS VALVE THRU MIICROSWITCH SUPPLY 4 EXHAUST FAN(S) IN SINGLE (D a 1.4 D -15 •- 1 HAZARD AREA ARE ALL INTERLOCKED TO ONE (1) ELECTIGAL SWITCH W/PILOT LIGHT. Z (D WALL PANELING 020 GA- C/L H /RODS, G/1 ANGLES H (EXHAUST 4 SUPPLY), VERIFY FINISHED CEILING HEIGHT. IF REQUIRED PROVIDE SOFFIT OR UNISTRUGT. JIB W /RIGID CONDUIT 18 F.P.G. 15 REPON5I5LE FOR SUPPLYING PERMITS, SHOP DWGS AND INSTALLATION OF ALL SYSTEM FIRE RATED ENCLOSURE _ r� (W /ACCESS PANELS) PERIMETER OF HOOD/VENT'R t0 FINISHED CLG. X COMPONENTS INCLUDING PIPING (B /1, C/P OR 5/5), SLEEVES, NOZZLES, MECHANICAL DETECTORS, OF v) ISOLATION BUSHING CABLE, PULLEYS, LIQUID TIGHT FITTINGS, SYSTEM SUPPLY TANK 4 TESTING. U FD _/61-J NOZZLES -PL'M, APP'E 4 DU'K -4-- P -+-- A -t- D 21 G/C TO CONSTRUCT FIRE RATED ENCL05URE(5) WITH ACCESS PANELS. SEE DETAIL IF APPLICABLE. 3 LIGHT FIXTURES. NUT 4 EXTRACTORS (FILTERS). IS PROVIDE MECHANICAL GAS VALVE W/MANUAL RESET. VERIFY TYPE OF GAS AND GAS LINE SIZE. CD p VAPOR PROOF FLUORESCENT RIGID STEEL FRAME MINIMUM 1 -1/4' (32mm) WORK PROVIDED BY OTHERS, OWNER, GENERAL CONTRACTOR (G /C): 20 G/C PROVIDES ALL NECESSARY FIRE5TOPPING, ELECTRICAL CONNECTIONS INTERCONNECTIONS ROOF- Co X , / 14.ANGLE " OLE THICK NEOPRENE ELEMENT WITH ING MATERIALS, CUTTM/PATCHING OF ROOF, ROOF CURB FLASHING REQUIRED FOR ALL FANS N WALL PANELING 020 GA- C/L H /RODS, G/1 ANGLES 4 I' MINERAL WOOL. (EXHAUST 4 SUPPLY), VERIFY FINISHED CEILING HEIGHT. IF REQUIRED PROVIDE SOFFIT OR UNISTRUGT. JIB W /RIGID CONDUIT J J� O FIRE RATED ENCLOSURE _ PROJECTING ROD (W /ACCESS PANELS) PERIMETER OF HOOD/VENT'R t0 FINISHED CLG. X PULL STATION (FPS) REMOTE OF 3' STEEL ISOLATION BUSHING o DISCONNECT SWITCH FD _/61-J NOZZLES -PL'M, APP'E 4 DU'K -4-- P -+-- A -t- D 21 G/C TO CONSTRUCT FIRE RATED ENCL05URE(5) WITH ACCESS PANELS. SEE DETAIL IF APPLICABLE. N LIGHT FIXTURES. NUT 4 EXTRACTORS (FILTERS). NEOPRENE SPRING 22 G/C PROVIDES FIRE RATED MATER'S AS REQUIRED FOR WALLS WHERE vENTILATOR(5) ARE INSTALLED. p VAPOR PROOF FLUORESCENT WASHE CUP WITH LIGHT FIXTURES. , U.L. "89492, PROJECTING ROD ISOLATION BUSHING 23 G/C PROVIDES PAINTING OF EXPOSED, EXTERIOR DUCTWORK 4 CURBS IF REQUIRED BY LOCAL CODES, U 3/8'0 H/ROD EXTENDED TO THE HOOD 24 G/C TO COORDINATE INSTALLATION OF REMOTE PULL STATION (60" AFF) CONDUIT RECESSED IN WALL w ROD CAN SWING OR 5URFACE MOUNTED. O 307 IBEFORE CONTACTING FLUMIBING CONTRACTOR (OR GAS COMPANY): 2 RESILENT BUSHING 25 REPONS15LE FOR LOCATION 4 INSTALLATION, GAS VALVE W/MANUAL RESET. VERIFY TYPE OF GAS_ 0* ISOLATOR SPRING VERIFY GAS LINE SIZE. [D-22 D-23 CEILING MOUNTED ELECTRICAL CONTRACTOR: (FANHANGER) 26 RESPONSIBLE FOR SUPPLYING, INSTALLATION OF MAG. STARTERS, DISCONNECTS (FANS), CONTROL SWITCH(S), MAG. CONTRACTORS, RELAYS, SHUNT TRIP BREAKERS, ELECTR CONDUIT, WIRING, ETC- NO. I DATE REVISION 21 ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY CONNECTIONS, INTERCONNECTIONS AND START- JO': UP FOR THE FOLLOWING: EXHAUST VENTILATOR(S), FIRE PROTECTION SYSTEM (MICROSWITCHES), MOTOR CONTROLS, LIGHT FIXTURES, LIGHT SWITCHES, EXHAUST AND SUPPLY FANS ETC. KA130K SHACK 28 FLEXIBLE CONNECTION (GREENFIELD) REQUIRED FROM J/BOX TO F.F.S. FOR SERVICING SYSTEM. 12/93 CERTIFIED TEST 4 5ALANGE 29 INDEPENDENT TEST 4 BALANCE REPORT FOR KITCHEN AREA REQUIRED BEFORE THE FINAL JOB ADDRESS INSPECTIONNEGATIVE PRESSURE IN THE KITCHEN AREA NOT TO EXCEED 0,02 IN WATER COLUMN. 1400 S.W. 51 AVENUE 04 :HAU T WORIGING PROCEDURE; FAN - ��', ` SOUTH MIAMI, FLORIDA L ALL EQUIPMENT OFF. rF.wi 2, IN CASE THAT MANUAL SWITCH 15 NOT ACTIVATED. GO TO POINT 3. � 3. COOKING EQUIPMENT ON. 4. SENSOR LOCATED AT APP 100' WILL IBS t ACTIVATED BY TEMP A15OVE OR EQUAL 135 7F 5. THERMO COUPLE CONTACTS WILL CLOSE THE 120 VOLT CIRCUIT VOLTAGE WILL BE APPLIED TO RELAY 6, 120 VOLTS CONTACTS OF THE RELAY WILL BE CLOSE 1. MANUAL SWITCH WILL BE BYPASSED AND EXHAUST FAN AND AIR SUPPLY FAN WILL TURN ON. L1 1 T IE f;RMAL. 5EN&OR CONNECTION 5C�E1„IAT I CS (T "rf ) LEANDRO ESPINOS E. License PE 6 459 East 56 Street Hialeah, FL 33013 706- 553 -5511 1 VENTILATION 6YrF. , FLAN, ELEVATION 4 SECTION JOt NUMWER 2013 -01 RROJECT DATE PAGE NUMMER 01 -14 -13 CAD FILE 2013 -01 -02 2 DRAWN NY; B. DIAZ SCALE OF N/A 2 SYMBOLS EXHAUST DUCT (E/D) - - ---°- • --- - SUPPLY DUCT (SID) -- -- .... .... - WALL PANELING 020 GA- C/L H /RODS, G/1 ANGLES 4 I' MINERAL WOOL. - - - - OR UNISTRUGT. JIB W /RIGID CONDUIT J J� O FIRE RATED ENCLOSURE _ FOR PREWIRED LIGHT (FIRE CHASE) PULL STATION (FPS) REMOTE OF INSULATED CURB MANUAL, EXPOSED CONDUIT. (SEE DETAIL) DISCONNECT SWITCH FD _/61-J NOZZLES -PL'M, APP'E 4 DU'K -4-- P -+-- A -t- D VAPOR PROOF INCAD. `(Q�� REMOVABLE 16120 GREASE G� LIGHT FIXTURES. , EXTRACTORS (FILTERS). EXHAUST DUCT COLLAR SUPPLY DUCT COLLAR C� VAPOR PROOF FLUORESCENT F/DAMPER NAILOR HART LIGHT FIXTURES. 0 U.L. "89492, VENTILATION 6YrF. , FLAN, ELEVATION 4 SECTION JOt NUMWER 2013 -01 RROJECT DATE PAGE NUMMER 01 -14 -13 CAD FILE 2013 -01 -02 2 DRAWN NY; B. DIAZ SCALE OF N/A 2