HVAC GENERAL NOTES
1. ALL WORK REFLECTED ON THESE DOCUMENTS ARE IN STRICT ACCORDANCE WITH
2004 EDITION OF FLORIDA BUILDING CODE- RESIDENTIAL. INCLUDING 2006 SUPPLEMENTS
AND ALL APPLICABLE NFPA, ASHRAE STANDARDS & LOCAL ORDINANCES.
2. CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL
CONSTRUCTION CONDITIONS.
3. CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, PERMITS, FEES,
INSPECTIONS, TESTS AND INSURANCE ETC.
4, ALL SUPPLY AND RETURN AIR DUCTWORK INDICATED ON THESE DOCUMENTS SHALL BE
FIBERGLASS DUCT BOARD OR FLEXIBLE INSULATED DUCT WITH CORROSION RESISTANT
REINFORCING WIRE HELIX WITH R -6 INSULATING VALUE WHERE INSTALLED IN ATTIC SPACE.
ALL OTHERS MAY BE FIBERGLASS DUCT BOARD WITH R -5 INSULATING VALUE.
EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL UNLESS OTHERWISE
INDICATED AND BE CONSTRUCTED AND INSTALLED IN STRICT ACCORDANCE WITH
SMACNA STANDARDS.
5. ALL AR DISTRIBUTION DEVICES SHALL BE AS SCHEDULED.
6. CONTRACTOR SHALL VERIFY SPACE CONDITIONS AND DIMENSIONS AND
COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO FABRICATION
AND INSTALLATION OF DUCTWORK AND ORDERING EQUIPMENT. THIS
SHALL INCLUDE BUT NOT BE LIMITED TO:
A) COORDINATE THE LOCATION OF THE GRILLES, LOUVERS, WALL AND
ROOF OPENINGS SIZES AND LOCATIONS WITH THE ARCHITECTURAL
TIC STRUCTURAL FEATURES AND ELEMENTS.
B) COORDINATE THE LOCATION OF THE A/C EQUIPMENT AND FANS TO
AVOID INTERFERENCE WITH OTHER TRADES AND THE ARCHITECTURAL AND
STRUCTURAL ELEMENTS OF THE BUILDING.
7. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS.
8. CONTRACTOR SHALL MAKE NECESSARY REPAIRS IN DUCTWORK FOR AN AIR
TIGHT SYSTEM.
9. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATION OF FIRE RATED
BARRIERS PER LOCAL CODES. CEILING FIRE DAMPERS SHALT. BE RADIATION
TYPE, U.L LABEL
10. ALL EXHAUST FAN OUTLETS SHALL MEET ALL SEPARATION REQUIREMENTS
AS SET FORTH IN FLORIDA BUILDING CODE.
11. WHERE DUCTS PASS THROUGH BUILDING STRUCTURE THE OPENING SHALL
BE 1" LARGER IN ALL DIRECTIONS.
12. REFRIGERANT PIPING SHALL BE TYPE 'L' COPPER, INSULATE SUCTION LINE
WITH 3/4" THICK FOAMED PLASTIC INSULATION, 25/50 FLAME SPREAD AND
SMOKE DEVELOPED RATING (MAXIMUM) (R -4),
13. ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR PERIOD OF
ONE YEAR FROM DATE OF ACCEPTANCE. COMPRESSORS SHALL CARRY
5 YEAR FACTORY WARRANTY.
14. ALL OTHER ELEMENTS / COMPONENTS AND PARTS NOT SPECIFICALLY
NOTED HEREIN AND IS REQUIRED AS STANDARD PRACTICE FOR A
COMPLETE WORKING SYSTEM SHALL BE PROVIDED AND INSTALLED AT NO
ADDITIONAL COST TO OWNER.
15. ALL ROOF MOUNTED EQUIPMENT AND ACCESSORIES, ALONG WITH EQUIPMENT
LOCATED AT GRADE, SHALL BE SECURED TO WITHSTAND THE FLORIDA BUILDING
CODE 1619.2 WIND LOAD REQUIREMENTS.
16. ALL WORK SHALL BE PERFORMED IN FIRST CLASS WORKMANLIKE MANNER.
17. INSTALL ALL EQUIPMENT AS PER MANUFACTURER'S RECOMMENDATIONS.
18. BALANCE EACH AIR SYSTEM TO DELIVER QUANTITIES INDICATED. SUBMIT
AIR BALANCE TEST RESULTS, PRIOR TO FINAL ACCEPTANCE BY OWNER,
19. BUILDING ENVELOP INSULATION:
ca) ROOF R -30
b) WALLS R -4.1
c) PARTITION - NONE
20. INSTALLATION AND TERMINATION OF ALL CONTROL WIRING IS THE RESPONSIBILITY
OF MECHANICAL CONTRACTOR. COORDINATE ALL REQUIRED J-BOXES AND
CONDUITS WITH THE ELECTRICAL CONTRACTOR.
21. CONDENSATE DRAIN PIPING:
SEE PLUMBING PLANS.
PVC SHALL NOT BE INSTALLED IN RETURN AIR PLENUM.
ELECTRICAL GENERAL NOTES
A. GENERAL PROVISION.
1, GENERAL: PROVOE--.ALL. LABOR, MATERAAI- AND EQUIPMENT FOR A COMPLETE AND PROPERLY
OPERATING ELECTRICAL SYSTEM.
2. CODES AND STANDARDS: CONFORM TO THE REQUIREMENT OF ALL GOVERNING CODES AND
STANDARDS, INCLUDING NATIONAL ELECTRICAL CODE (2002 EDITION).
3. VISIT THE SITE OF PROPOSED PROJECT TO BECOME FAMILIAR WITH THE WORK CONDITIONS
AND NATURE OF WORK, PRIOR TO SUBMITTING BIDS. NOTIFY ENGINEER OF DISCREPANCIES
OR OMISSIONS FOR INTERPRETATION OR DECISION AND SUCH DECISION SHALL BE FINAL.
B. BASIC MATERIALS AND METHODS:
CONDUIT - INTERIOR WORK: CONCEALED ELECTRICAL METALLIC TUBING; EXTERIOR BELOW
GRADE: SCHEDULE 40 PVC; EXTERIOR EXPOSED: SCHEDULE 40 RGS,
OUTLET BOXES -- 4" x 4" STEEL WITH PLASTER RINGS SIZED IN ACCORDANCE WITH N.E.C.
FOR CONCEALED INTERIOR WIRING, CAST FERROUS OUTLET BOXES WITH INTEGRAL HUBS FOR
EXPOSED AND EXTERIOR DEVICES.
WIRE - COPPER, THHN/THWN DUAL RATED.
WIRING DEVICES - SPECIFICATION GRADE DEVICES AND PLATES WITH IVORY FINISH, EXCEPT
MATCH PANELED WALL WITH DEVICES AND PLATES OF SIMILAR COLOR.
>. RECEPTACLES: 20 AMPS, 120V, 2 POLE, 3 WIRE, GROUNDING TYPE OR ISOLATED GROUND
TYPE AS SHOWN ON DRAWINGS.
b. SWITCHES: 20 AMPS, 120/277V.
C. LIGHTING FIXTURES:
1. FURNISH LIGHTING FIXTURES AS REQUIRED BY OWNER AND AS INDICATED ON DRAWINGS.
FURNISH ALL NECESSARY MOUNTING HARDWARE AND LAMPS.
2. ALL RECESSED INCANDESCENT FIXTURES SHALL SATISFY THE REQUIREMENTS OF N.E.C.
410-- 65(2).
D. PANELS:
1, ALL PANELS SHALL BE U.L. RATED AND OF THE SAME MANUFACTURER. PROVIDE SIZE AND
TYPE AS INDICATED ON DRAWINGS. PANELS SHALL HAVE FULL SIZE NEUTRAL BUS AND 1/2
SIZE GROUND BUS.
E. GROUNDING:
1. PROVIDE CONTINUOUS GROUNDING SYSTEM IN ACCORDANCE WITH N.E.C. SECTION 250, AND
AS INDICATED. PROVIDE GROUND CONDUCTOR IN ALL RACEWAYS.
F. IF, THROUGH ERRORS OR OMISSIONS, THE INTENT OF ARCHITECT /ENGINEER WITH REGARD TO ANY DETAIL.
IS NOT CLEAR, OR IS CAPABLE OF MORE THAN ONE INTERPRETATION, SUCH MATTERS WILL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT /ENGINEER IN WRITING BEFORE THE SUBMISSION OF BIDS, AND
THE ARCHITECT /ENGINEER SHALL MAKE CORRECTION OR EXPLANATION IN WRITING. OTHERWISE, NO
EXTRA CHARGE WILL BE ALLOWED FOR THE WORK OR MATERIAL WHICH THE ARCHITECT /ENGINEER WILL
REQUIRE, PROVIDED THAT IT COMES WITHIN A REASONABLE INTERPRETATION OF THE DRAWINGS AND
SPECIFICATIONS.
G. THE PLANS AND SPECIFICATIONS ARE INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE
PERFORMED. ALL ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE
COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR. THIS
CONTRACTOR SHALL THOROUGHLY ACQUAINT HIMSELF WITH THE MECHANICAL, ARCHITECTURAL,
STRUCTURAL AND ELECTRICAL PLANS BEFORE SUBMITTING HIS FINAL BID. NO ADDITIONAL
COMPENSATION WILL BE ALLOWED DUE TO THE CONTRACTOR'S FAILURE TO FAMILIARIZE HIMSELF WITH
THE PLANS.
H. INFORMATION SHOWN ON THE DRAWINGS AS TO THE LOCATION OF EXISTING UTILITIES HAS BEEN
PREPARED FROM THE MOST RELIABLE DATA AVAILABLE TO THE ENGINEER. THIS INFORMATION IS NOT
GUARANTEED, HOWEVER, AND IT SHALL BE THIS CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
LOCATION, CHARACTER AND DEPTH OF EXISITNG UTILITIES.
. . 1 0 .11 30"
41 o e :go
CIRCUIT
1
3
5
6
9
10
11
12
13
14
15
16
17
18
19
21
22
23
24
25
26
27
28
29
30
1201240V 1 PHASE 3 WIRE
150 AMP
PANEL -7----XISTING ELECTRICAL
LOCATION BREAKER POLE WIRE CONDUI-1
CU 30 2 10 3/4
AHU 40 2 8 3/4
CU 30 2 10 314
AHU 40 2 8 3/4�
EXISTING 15 1 12 1/2 I
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 1.2 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
EXISTING 15 1 12 1/2
LIGHTING 15 1 12 1/2
RANGE 40 2 8 3/4
MICROWAVE 20 1 12 1/2
RANGE 40 2 8 3/4
RECEPTACLES 15 1 12 1/2
RECEPTACLES 15 1 12 1/2
...
U V v V V U V v V
Architect:
i
i
Z
> 'r-
'r-
< CO
QD LL
W
Q
O�
co
CD
d ae
k PMYw
IN MY PROFESSIONAL JUDGEMENT AND TO -rHE BEST OF
MY KNOWLEDGE AND BELIEF, THESE PLANS AND THE
SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING
CODE AND ALL APPLICABLE CODES.
COPYRIGHT(D 2007 James Griffin, Architect
ALL RIGHTS RESERVED. THESE DRAWINGS AND THE
SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF JG . WHETHER THE
PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED
OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER
ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT
EXCEPT BY AGREEMENT IN WRITING AND WITH THE
APPROPRIATE COMPENSATION TO JG. REPRODUCTIONS
OF SPECIFICATIONS WITHOUT I.HE WRITTEN CONSENT
OFJG IS PROHIBITED.
EXISTING
FLOOR
PLAN AND
DETAILS
I
W
v
i X-
Z
L.I_
LLJ Q
I� L.
LL' Q
croo
t- 0,�
ul o
m f" u„
rj
V)
L(1
'q-
%.I..I
00 mcn --
PV to CO -
--1 < m Ln 2
d ae
k PMYw
IN MY PROFESSIONAL JUDGEMENT AND TO -rHE BEST OF
MY KNOWLEDGE AND BELIEF, THESE PLANS AND THE
SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING
CODE AND ALL APPLICABLE CODES.
COPYRIGHT(D 2007 James Griffin, Architect
ALL RIGHTS RESERVED. THESE DRAWINGS AND THE
SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND
SHALL REMAIN THE PROPERTY OF JG . WHETHER THE
PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED
OR NOT. THEY ARE NOT TO BE USED IN ANY MANNER
ON OTHER PROJECTS OR EXTENSIONS TO THIS PROJECT
EXCEPT BY AGREEMENT IN WRITING AND WITH THE
APPROPRIATE COMPENSATION TO JG. REPRODUCTIONS
OF SPECIFICATIONS WITHOUT I.HE WRITTEN CONSENT
OFJG IS PROHIBITED.
EXISTING
FLOOR
PLAN AND
DETAILS