Loading...
09-667R-0061, G I PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION - - - - - - - EXISTING VENT LINE - - - - - - EXISTING SANITARY LINE - EXISTING WATER LINE - - EXISTING HOT WATER LINE -- --- - -- VENT LINE ISSUE INSTRUCTIONS AS HOW TO PROCEED. SANITARY LINE - WATER LINE -- HOT WATER LINE CO- CONDENSATE DRAIN LINE PT PRESSURE AND TEMPERATURE RELIEF DRAIN LINE -po--- GATE VALVE LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH CHECK VALVE --I �- COUPLING OR UNION ---1i1 PRESSURE AND TEMPERATURE RELIEF VALVE ----c HOSE BIBB PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED. WHERE HEAD PIPE DOWN --0 PIPE UP --II CO CLEANOUT HI WCO WALL CLEANOUT ( - - FLOOR CLEANOUT. ?'71K - -.-...... CLEANOUT TO GRADE -� WATER CLOSET DRAIN ---�I P -TRAP WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE DISHWASHER DRAIN SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR WASHER BOX ® WATER METER VTR VENT THRU ROOF FU FIXTURE UNIT CW COLD WATER HW HOT WATER CD A/C CONDENSATE DRAIN PT PRESSURE AND TEMPERATURE RELIEF DRAIN FCO FLOOR CLEANOUT CTG CLEANOUT TO GRADE EXIST. EXISTING MIN. MINIMUM TYP. TYPICAL Q� I NEW CONNECTION PLUMBING GENERAL. NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND 8. PROVIDE MEANS "FURNISH AND INSTALL". BUILDING CODES GOVERNING THE INSTALLATION OF THE MECHANICAL SYSTEM. IF "A" WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH 9. AS USED HEREIN, ALL STATEMENTS RELATED TO EXISTING FIELD CONDITIONS FIELD CONDITIONS, LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE SHALL MEAN AN EXPRESSION OF THE CONSULTAN'S PROFESSIONAL OPINION TO THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT /ENGINEER BEFORE BEST OF ITS INFORMATION, KNOWLEDGE AND BELIEF, AND DOES NOT CONSTITUTE A SUBMITTING A BID OR PROCEEDING WITH WORK. THE ARCHITECT /ENGINEER WILL THEN WARRANTY OR GARANTEE BY THE CONSULTANT. THE CONTRACTOR SHALL VISUALLY ISSUE INSTRUCTIONS AS HOW TO PROCEED. INSPECT AND VERIFY ALL EXISTING FIELD CONTITIONS AS PART OF HIS /HER DUTIES DRAIN AND NOTIFY THE DESIGN PROFESSIONAL, IN WRITING, OF ANY DISCREPANCIES. 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY FU SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC 10, CONTRACTOR SHALL VISIT THE SITE AND REVIEW ALL PERTINENT UTILITY DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS DRAWINGS TO FAMILIARIZE HIMSELF WITH THE LOCATION OF ALL EXISTING AND /OR SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN PROPOSED UTILITY STUB OUTS, PIPING, EQUIPMENT, ETC,, AND MAKE DUE LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH ALLOWANCES FOR ANY CONDITION AFFECTING HIS WORK. WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS AT ALL POINTS. COORDINATE LOCATION OF PIPEWORK WITH OTHER 11. ALL UNDERGROUND SANITARY t, STORM DRAINAGE PIPING AND FITTINGS SHALL BE TRADES, PARTICULARLY WHERE PIPES RUN THROUGH STRUCTURAL ELEMENTS, PVC -DWV (ASTM 0- 2665/D- 2949). PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED. WHERE HEAD WC ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE 12. ALL ABOVE GROUND SANITARY t STORM DRAINAGE BRANCH k VENT PIPES AND NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, FITTINGS SHALL BE PVC -DWV (ASTM D- 2665/D- 2949), EXCEPT WHEN INSTALLED IN WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO RETURN PLENUM, WHERE CAST IRON OR EQUIVALENT NON - COMBUSTIBLE PIPING MUST PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF BE USED. THE WORK. DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. ANY CHANGES TO THESE OR ANY CONSTRUCTION L 13. ALL UNDERGROUND WATER PIPING SHALL BE COPPER TYPE "L" (ASTM B -75). ALL 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR ABOVE GROUND PIPING SHALL BE COPPER TYPE "M" (ASTM B -35). WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE 1- 1/2 " @1 /4 " /FT SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR 14. ALL HOT WATER PRESSURE AND TEMPERATURE RELIEF PIPING SHALL BE COPPER CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TYPE "L" (ASTM 15-35). TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCE OR OMISSIONS OCCUR BT BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT /ENGINEER IN AMPLE TIME TO 15. ALL AIR CONDITIONING CONDENSATE DRAINAGE PIPING SHALL BE SCH. 40 PVC PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. (ASTM D- 2665), EXCEPT WHEN INSTALLED IN RETURN AIR PLENUM WHERE COPPER 2 " @1 /4 " /FT TYPE "DWV" OR EQUIVALENT MUST BE USED. 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE INTEGRAL MANNER, THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT 16. ALL PLUMBING FIXTURES SHALL BE PROVIDED WITH ALL NECESSARY ACCESSORIES OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE SUCH AS STOP VALVES, "P" TRAPS, SUPPORTS, P L T VALVES, ETC., AS REQUIRED. APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN ALL EXPOSED PIPING AT FIXTURES AND EQUIPMENT SHALL BE CHROME PLATED DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. BRASS PIPE OR TUBE, PROVIDE SHUT OFF VALVES AND UNIONS TO ALL FIXTURES, ETC., REQUIRING WATER SUPPLY. PROVIDE DIELECTRIC COUPLINGS AS REQUIRED. FOR 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM ALL COPPER PIPING CONTRACTOR MUST USE 95/5 SOLDER. PROVIDE WATER HAMMER OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES ARRESTORS TO EACH FIXTURE AS REQUIRED. OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE 2" AND REPLACE, AT HIS EXPENSE, ALL MECHANICAL WORK WHICH MAY HAVE TO BE 17. PROVIDE CLEANOUTS (WITH CHROME PLATED WALL OR FLOOR ACCESS FRAMES REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. AND COVERS AS REQUIRED) AT THE BASE OF ALL WASTE AND /OR VENT STACKS. N/A PROVIDE PITCH PANS L LEADS FLASHING FOR ALL SANITARY SYSTEM VENTS. 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS, W /ANTI -SCALD VALVES ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO 18 ALL HORIZONTAL WASTE PIPING SHALL BE SLOPPED AT 1/8 PER FOOT, UNLESS THIS WORK. HE SHALL ALSO PAID ALL THE INSPECTION FEES AS MAY BE REQUIRED OTHERWISE NOTED. BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE 2 " @1 /4 " /FT AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, RULES OR ORDINANCES. 19. FOR INSTALLATION OF ANY ROOF MOUNTED OR WALL MOUNTED EQUIPMENT REFER WALL MOUNTED TO STRUCTURAL ENGINEERING DRAWINGS. 7. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. SK 10. AT COMPLETION OF JOB THE MECHANICAL CONTRACTOR SHALL GIVE THE OWNER 20, CONTRACTOR TO FIELD VERIFY ALL FIXTURES AND EQUIPMENT MARKED ON PLANS AN AS -BUILT SET OF REPRODUCIBLE DRAWINGS SHOWING THE EXACT LOCATION OF AS EXISTING. ALL INSTALLATIONS. 2 PLUMBING FIXTURE CONNECTION SCHEDULE * SHOWN FOR REFERENCE ONLY, REFER TO ARCHITECT /OWNER FOR LIST OF EXACT FIXTURE TYPE AND MANUFACTURER. ** AS PER FLORIDA PLUMBING CODE TABLE 604.4 CONN.SIZE "A" A (1 -11 F.U.) WATER 8.44_ 4 B (12 -32 F.U.) 3/4" C" MAXIMUM 1" No. DESCRIPTION DRAIN SLOPE FU MANUFACTURER FIXTURE WATER FLOW REMARKS COLD HOT Y �44•r These record drawings have been prepared based * TYPE * RATE ** • WC WATER CLOSET 3" 1/2" N/A 3" &4" @1 /8 " /FT 3 AMERICAN STANDARD FLOOR MOUNTED 128 GPF DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. ANY CHANGES TO THESE OR ANY CONSTRUCTION L LAVATORY 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT 1 AMERICAN STANDARD WALL MOUNTED 1.0 GPM INTO THE ORIGINAL SET OF PLANS TO CREATE A FINAL "RECORD DRAWING" SET IS NOT BT BATH TUB 2" 1/2" 1/2" 2 " @1 /4 " /FT 2 AMERICAN INTEGRAL 1.5 GPM W /ANTI -SCALD VALVES STANDARD • r• r • SH SHOWER 2" 1/2" 1/2" 2 " @1 /4 " /FT 2 N/A N/A 1.5 GPM W /ANTI -SCALD VALVES UR URINAL 2" N/A N/A 2 " @1 /4 " /FT 2 AMERICAN STANDARD WALL MOUNTED 0,5 GPF ' SK SINK 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4" /FT 2 AMERICAN COUNTERTOP 1.0 GPM STANDARD 0 0 INDIRECT WASTE DW DISHWASHER 1" N/A 1/2" N/A N/A N/A N/A 6.5 GALL /CYCLE CONNECT TO SINK REF REFRIGERATOR N/A 112" N/A N/A N/A N/A N/A N/A ICE MAKER CONNECTION LS LAUNDRY SINK 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT 2 AMERICAN STANDARD COUNTERTOP 1.0 GPM WATER FACTOR PROVIDE WM BOX W/ W CLOTHES 3" 1/2" 1/2" 2 " @1 /4 " /FT 2 N/A N/A 8 OR LOWER (2) 1/2" HB & 3" DRAIN E EWH ELECTRIC N/A 3/4" 3/4" N/A N/A N/A N/A N/A 50 GALLON, 6.0KW/240/1/60 WATER HEATER PLUMBING NOTES 1. RUN 1 -1/2" PIPE @ 1/4" FT FIXTURE ARM. 2. RUN 2" PIPE @ 1/4" FT. 3. RUN 3" L 4" PIPES @ 1/8" FT. 4. PROVIDE CLEANOUT AT BASE OF EACH SOIL AND WASTE STACK. 5, SHOWERS lk TUBS VALVES TO BE ANTI -SCALD TYPE. G. INSTALL 1/2" CW AT RIGHT SIDE OF FIXTURES. INSTALL 1/2" HW AT LEFT SIDE OF FIXTURES PROVIDE WATER HAMMER ARRESTOR. T. DOMESTIC HOT WATER AND RECIRCULATING PIPING SHALL BE INSULATED WITH INSULATING MATERIAL HAVING A CONDUCTIVITY BETWEEN 0.24 AND 0.28 [BTU- IN /(H•FT3-19F)) INSULATION THICKNESS SHALL BE AS FOLLOWS: FOR PIPES 3/4" AND SMALLER - 1/2" THICK FOR 1" PIPE - 3/4" THICK FOR PIPES 1 -1/4" AND LARGE - 1" THICK WATER HAMMEIR ARRESTER SCHEDULE MARK * P.D.LSIZE CONN.SIZE "A" A (1 -11 F.U.) 1/2" 8.44_ 4 B (12 -32 F.U.) 3/4" C" C (33 -60 F.U.) 1" * PLUMBING AND DRAINAGE INSTITUTE STANDARD WH -201 SITE INVESTIGATION BEFORE BIDDING, CONTRACTOR SHALL PERFORM A THOROUGH INVESTIGATION OF ACTUAL CONDITIONS AT THE JOB SITE; AND INCLUDE ALL WORK REQUIRED TO INTRODUCE SYSTEM COMPONENTS INTO EXISTING STRUCTURES, AND TO CONNECT OR MODIFY EXISTING SYSTEMS AS INDICATED ON DRAWINGS OR NECESSITATED BY THE INSTALLATION. PERFORM ALL SUCH WORK WITHOUT ADDITIONS TO THE CONTRACT COST, WHERE INDICATED ON DRAWINGS REMOVE OR RELOCATE EXISTING SYSTEM COMPONENTS AND PROPERLY PATCH AND FINISH RESULTING OPENINGS IN THE BUILDING STRUCTURE WITH THE SAME MATERIAL AS THOSE ADJACENT TO THE OPENINGS. 4�, �J__lJJ �rn Irn'I I I N 0055 ? ?? 1 /a'l = 1 1 -011 AT` ? rra• Y Y •4c t 4 rG v u4 8.44_ 4 '4r4 • 8 4.1 D RECORD DRAWINGS WINGS RECOR RA INSTALLATION, AND /OR DISTRIBUTION THAT DEVIATE FROM THE ORIGINAL SIGNED, SEALED 6 6 E AND APPROVED PLANS, PROPOSED CHANGES, ADDITIONS, AND /OR MODIFICATIONS WHICH • r 4 f W Y �44•r These record drawings have been prepared based • 4 4 Q N • V • others. The engineer has not verified the accuracy 9 y ALL IDEAS DESIGN ARRANGEMENTS AND PLANS INDICATED DR REPRESENTED BY THIS DRAWINGS ARE .WNEO OYAND THE PROPERTY OF THE DESIGN PROFESSIONAL AND WERE CREATED EVOLVED RESPONSIBLE AND WILL NOT INTEGRATE FIELD CHANGES INTO THE ORIGINAL PLANS THAT and /or completeness of this information and shall DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. ANY CHANGES TO THESE OR ANY CONSTRUCTION HAVE NOT BEEN CONSULTED AND APPROVED BEFORF THEIR FIELD IMPLEMENTATION. THE not be responsible for any errors or omissions that • •r • •fr •I 4 SHALL AUTOMATICALLY RENDER THE DESIGN PROFESSIONAL AND THE ENGINEERING CONSULTING GROUP, P.A. HARMLESS TO ANY LIABILITY CLAIMS, SUITOR LITIGATION BY ANY INTERESTED PARTIES INTO THE ORIGINAL SET OF PLANS TO CREATE A FINAL "RECORD DRAWING" SET IS NOT information provided by others. OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE COPIED OR REPRODUCED BY ANY MEANS, OR USED IN CONNECTION WITH ANY WORK OTHER THAN FOR THE SPECIFIC PROJECT FOR INCLUDED IN THE ORIGINAL CONTRACT AND SHALL BE CONSIDERED ADDITIONAL SERVICES. WHICH THEY HAVE BEEN PREPARED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. • r• r • • 4 I � • • • f • f '• W •' r ' • • • • r • i • � 4 ' ici C2 i 6•itlf i1• i'�r•i 0 0 U 4j e r • r • u Off* • ••rfi Y frf Cy .)1.6Ci I 4 0 r5 71 5 � 2 I � I EXISTING WATER METER ASSEMBLY W/S UTOFF VALVE, TO BE REPLACED WITH 1" METER IF SMALLER (C NTRACTOR TO VERIFY ON SITE) 5 0055 22 5 59.69' EXISTING CITY WATER SERVICE PIPE I l f 0 1 1 /a'l = 1 1 -011 AT` NORTH FIELD CHANGES: THE CONTRACTOR SHALL CONSULT THE ENGINEER BEFORE THE IMPLEMENTATION OF FIELD CHANGES, MODIFICATIONS, AND /OR ADDITIONS TO EQUIPMENT, D RECORD DRAWINGS WINGS RECOR RA INSTALLATION, AND /OR DISTRIBUTION THAT DEVIATE FROM THE ORIGINAL SIGNED, SEALED PLANS ARE PROTECTED UNDER THE COPYRIGHT LAWS OF FLORIDA: AND APPROVED PLANS, PROPOSED CHANGES, ADDITIONS, AND /OR MODIFICATIONS WHICH ALL RIGHTS RESERVED ARE INTENDED TO BE INCLUDED BY THE CONTRACTOR IN ITS "AS- BUILT" DRAWINGS SHALL These record drawings have been prepared based BE REVIEWED BY THE ENGINEER AND APPROVED IN WRITING BEFORE THE CHANGES, on the information compiled and provided b p p J CONTRACTOR SHALL VERIFY AND ■ERESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ONTHE Jf {. THE DESIGN PROFESSIONAL MUST { E NOTIFIED IN WRITING OF ANY VARIATION FROM THEPLANS. MODIFICATIONS, AND /OR ADDITIONS ARE IMPLEMENTED. THE ENGINEER SHALL NOT BE others. The engineer has not verified the accuracy 9 y ALL IDEAS DESIGN ARRANGEMENTS AND PLANS INDICATED DR REPRESENTED BY THIS DRAWINGS ARE .WNEO OYAND THE PROPERTY OF THE DESIGN PROFESSIONAL AND WERE CREATED EVOLVED RESPONSIBLE AND WILL NOT INTEGRATE FIELD CHANGES INTO THE ORIGINAL PLANS THAT and /or completeness of this information and shall DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED PROJECT. ANY CHANGES TO THESE OR ANY CONSTRUCTION HAVE NOT BEEN CONSULTED AND APPROVED BEFORF THEIR FIELD IMPLEMENTATION. THE not be responsible for any errors or omissions that PLANS WITHOUT THE WRITTEN APPROVAL OF THE DESIGN PROFESSIONAL EXECUTED FROM THESE PLANS WITHOUT EXPRESSED APPROVAL OF THE DESIGN PROFESSIONAL INTEGRATION BY THE ENGINEER OF FIELD CHANGES, MODIFICATIONS, AND /OR ADDITIONS may be incorporated herein as a result of erroneous SHALL AUTOMATICALLY RENDER THE DESIGN PROFESSIONAL AND THE ENGINEERING CONSULTING GROUP, P.A. HARMLESS TO ANY LIABILITY CLAIMS, SUITOR LITIGATION BY ANY INTERESTED PARTIES INTO THE ORIGINAL SET OF PLANS TO CREATE A FINAL "RECORD DRAWING" SET IS NOT information provided by others. OF THE PROJECT. NO PART THEREOF OF THESE PLANS SHALL BE COPIED OR REPRODUCED BY ANY MEANS, OR USED IN CONNECTION WITH ANY WORK OTHER THAN FOR THE SPECIFIC PROJECT FOR INCLUDED IN THE ORIGINAL CONTRACT AND SHALL BE CONSIDERED ADDITIONAL SERVICES. WHICH THEY HAVE BEEN PREPARED WITHOUT WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. I l f 0 1